ASTM E2476-22
(Guide)Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture
Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture
SIGNIFICANCE AND USE
4.1 This guide is intended to provide guidance regarding the use of risk management in the development, day-to-day running, and continuous improvement of pharmaceutical processes incorporating Process Analytical Technology (PAT). A consistent approach to the use of risk methodologies should be adopted to ensure rapid transfer of process understanding within the development and manufacturing teams, and to the regulators where that is appropriate.
4.2 This guidance only covers those aspects of risk assessment related to “risk to product quality.” Other aspects (such as “risk to patient”) should be covered in the conventional manner.
SCOPE
1.1 This document provides guidance on the assessment of risks to product quality within and related to PAT processes in the pharmaceutical industry. It addresses those risks to product quality arising from, associated with, identified by, or modified by the implementation of PAT in pharmaceutical development and manufacturing for primary, secondary, and biotech sectors of the industry. It does not replace those assessments of risk currently undertaken by pharmaceutical companies, but is, rather, an additional component focused specifically upon the evaluation and design of PAT processes. See Guide E2500 and ICH Q8.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Note that safety in this context refers to operational and operator safety, not to patient safety.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
- Status
- Published
- Publication Date
- 31-Oct-2022
- Technical Committee
- E55 - Manufacture of Pharmaceutical and Biopharmaceutical Products
- Drafting Committee
- E55.11 - Process Design
Relations
- Effective Date
- 15-Jun-2019
- Effective Date
- 15-Oct-2012
- Effective Date
- 15-Apr-2011
- Effective Date
- 01-Jun-2007
- Effective Date
- 15-Jul-2006
- Effective Date
- 15-Jan-2006
- Effective Date
- 15-Oct-2005
- Effective Date
- 15-Aug-2005
- Effective Date
- 01-Mar-2005
- Effective Date
- 01-Dec-2004
- Effective Date
- 01-Jul-2004
Overview
ASTM E2476-22 is a standard guide developed by ASTM for risk assessment and risk control as they impact the design, development, and operation of Process Analytical Technology (PAT) processes in pharmaceutical manufacturing. This guide provides structured guidance for evaluating and controlling risks specifically related to product quality in PAT-enabled pharmaceutical processes, applicable across primary, secondary, and biotechnology sectors. The standard supports the implementation of risk management strategies throughout the lifecycle of pharmaceutical development and manufacturing, facilitating improved process understanding, regulatory compliance, and product consistency.
Key Topics
Risk Assessment in PAT Processes
The guide highlights the importance of systematic and evidence-based risk assessment tailored to PAT processes. It focuses on identifying, prioritizing, and mitigating risks that could affect drug product quality, ensuring that all identified hazards are addressed through appropriate design and control measures.Risk Control Measures
E2476-22 encourages a multi-layered and dynamic approach to risk control:- Design modifications to reduce risk at source
- Implementation of control features within systems
- Detectability improvements through operating procedures, enhanced training, and monitoring
Continuous Improvement
Risk management is positioned as an ongoing, iterative process that evolves with new information, changes in production, and advances in process understanding. Regular review ensures continuous improvement and adaptability to emerging risks.Emphasis on Product Quality
The standard is exclusively focused on risks to product quality, not those directly related to patient safety, operational, or environmental risks. It complements existing risk assessments implemented by pharmaceutical companies rather than replacing them.Preparation and Team Composition
Successful risk assessment relies on well-prepared and knowledgeable teams, including subject matter experts from process design, quality, equipment, and manufacturing, ensuring a comprehensive evaluation from all perspectives.
Applications
ASTM E2476-22 is practical for a variety of stakeholders in the pharmaceutical industry:
Process Design and Development
Useful during early-stage process design to proactively identify and mitigate quality risks associated with PAT processes.Operational Risk Management
Guides ongoing risk assessment during routine manufacturing operations, supporting dynamic process improvements and troubleshooting.Regulatory Submissions
Provides a transparent and standardized approach to risk management that can be communicated to regulatory agencies, aiding in faster and smoother approvals.Quality Assurance and Control
Assists in identifying critical quality attributes (CQAs), critical control parameters (CCPs), and the factors causing variability, leading to more robust control strategies.Training and Knowledge Transfer
Standardized terminology and methodologies ensure consistent understanding and effective training for staff involved in PAT-based pharmaceutical manufacturing.
Related Standards
ASTM E2476-22 draws on and complements other international standards and guidelines relevant to pharmaceutical process risk assessment and PAT implementation:
- ASTM E2500: Guide for Specification, Design, and Verification of Pharmaceutical and Biopharmaceutical Manufacturing Systems and Equipment
- ICH Q8: Pharmaceutical Development
- ICH Q9: Quality Risk Management
- ICH Q10: Pharmaceutical Quality System
- FDA Guidance for Industry – PAT: A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance
- IEC 60812: Analysis Techniques for System Reliability-Failure Mode and Effects Analysis (FMEA)
- IEC 61025: Fault Tree Analysis (FTA)
- IEC 61882: Hazard and Operability Studies (HAZOP)
Summary
ASTM E2476-22 provides structured, practical guidance for risk assessment and risk control in PAT processes within pharmaceutical manufacturing. By focusing on process understanding and product quality, the standard helps ensure product consistency, continuous improvement, and regulatory compliance throughout the pharmaceutical product lifecycle. Pharmaceutical organizations implementing PAT can rely on this guide to establish robust risk management frameworks and enhance process reliability and quality.
Buy Documents
ASTM E2476-22 - Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture
REDLINE ASTM E2476-22 - Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
ASTM E2476-22 is a guide published by ASTM International. Its full title is "Standard Guide for Risk Assessment and Risk Control as it Impacts the Design, Development, and Operation of PAT Processes for Pharmaceutical Manufacture". This standard covers: SIGNIFICANCE AND USE 4.1 This guide is intended to provide guidance regarding the use of risk management in the development, day-to-day running, and continuous improvement of pharmaceutical processes incorporating Process Analytical Technology (PAT). A consistent approach to the use of risk methodologies should be adopted to ensure rapid transfer of process understanding within the development and manufacturing teams, and to the regulators where that is appropriate. 4.2 This guidance only covers those aspects of risk assessment related to “risk to product quality.” Other aspects (such as “risk to patient”) should be covered in the conventional manner. SCOPE 1.1 This document provides guidance on the assessment of risks to product quality within and related to PAT processes in the pharmaceutical industry. It addresses those risks to product quality arising from, associated with, identified by, or modified by the implementation of PAT in pharmaceutical development and manufacturing for primary, secondary, and biotech sectors of the industry. It does not replace those assessments of risk currently undertaken by pharmaceutical companies, but is, rather, an additional component focused specifically upon the evaluation and design of PAT processes. See Guide E2500 and ICH Q8. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Note that safety in this context refers to operational and operator safety, not to patient safety. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
SIGNIFICANCE AND USE 4.1 This guide is intended to provide guidance regarding the use of risk management in the development, day-to-day running, and continuous improvement of pharmaceutical processes incorporating Process Analytical Technology (PAT). A consistent approach to the use of risk methodologies should be adopted to ensure rapid transfer of process understanding within the development and manufacturing teams, and to the regulators where that is appropriate. 4.2 This guidance only covers those aspects of risk assessment related to “risk to product quality.” Other aspects (such as “risk to patient”) should be covered in the conventional manner. SCOPE 1.1 This document provides guidance on the assessment of risks to product quality within and related to PAT processes in the pharmaceutical industry. It addresses those risks to product quality arising from, associated with, identified by, or modified by the implementation of PAT in pharmaceutical development and manufacturing for primary, secondary, and biotech sectors of the industry. It does not replace those assessments of risk currently undertaken by pharmaceutical companies, but is, rather, an additional component focused specifically upon the evaluation and design of PAT processes. See Guide E2500 and ICH Q8. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Note that safety in this context refers to operational and operator safety, not to patient safety. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E2476-22 is classified under the following ICS (International Classification for Standards) categories: 11.120.10 - Medicaments. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM E2476-22 has the following relationships with other standards: It is inter standard links to ASTM E2629-19, ASTM E2500-07(2012), ASTM E2629-11, ASTM E2500-07, ASTM E2363-06a, ASTM E2363-06, ASTM E2363-05b, ASTM E2363-05a, ASTM E2363-05, ASTM E2363-04a, ASTM E2363-04. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM E2476-22 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2476 − 22
Standard Guide for
Risk Assessment and Risk Control as it Impacts the Design,
Development, and Operation of PAT Processes for
Pharmaceutical Manufacture
This standard is issued under the fixed designation E2476; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
This document provides guidance on the implementation of risk assessment and risk control for
Process Analytical Technology (PAT) processes within the pharmaceutical industry. Wherever
possible, other appropriate standards on risk assessment/management have been referenced and
acknowledged. Where practical, further details of methods and additional references have been
provided for information within the appendixes.
The application of risk assessment and risk control is pivotal to the creation of PAT systems, which
are described as “science-based” and “risk-based.” Such application starts at an early stage in the
development of the process and continues throughout development and production. In the production
phase, it is a crucial component of applying continuous improvement to the process.
RELATIONSHIP TO ICH Q9
The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for
Human Use (ICH) Q9 Guideline for Quality Risk Management is intended for general application
within the pharmaceutical industry. ICH Q9 describes the requirements for pharmaceutical quality risk
management and considers the risk as “risk to the patient.”
This document provides specific guidance on the risk assessment and risk control phases identified
in ICH Q9 in a limited set of conditions. It is applicable where the manufacturing method is compliant
with Process Analytical Technology (PAT) principles, and where the primary considerations are
product quality and reduction of process and product variability. The only component of risk to patient
considered here is risk to product quality. Other components fall outside the scope of the document.
In addition, other areas identified in ICH Q9, such as general risk management and risk
communication, are not considered here.
This document provides guidance which applies to the design, development, and operation of PAT
systems. It should be considered as a specific extension, supporting the ICH Q9 guidance for these
processes.
1. Scope currently undertaken by pharmaceutical companies, but is,
rather, an additional component focused specifically upon the
1.1 This document provides guidance on the assessment of
evaluation and design of PAT processes. See Guide E2500 and
risks to product quality within and related to PAT processes in
ICH Q8.
the pharmaceutical industry. It addresses those risks to product
quality arising from, associated with, identified by, or modified
1.2 This standard does not purport to address all of the
by the implementation of PAT in pharmaceutical development
safety concerns, if any, associated with its use. It is the
and manufacturing for primary, secondary, and biotech sectors
responsibility of the user of this standard to establish appro-
of the industry. It does not replace those assessments of risk
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
Note that safety in this context refers to operational and
This guide is under the jurisdiction of ASTM Committee E55 on Manufacture
of Pharmaceutical and Biopharmaceutical Products and is the direct responsibility of operator safety, not to patient safety.
Subcommittee E55.11 on Process Design.
1.3 This international standard was developed in accor-
Current edition approved Nov. 1, 2022. Published December 2022. Originally
dance with internationally recognized principles on standard-
approved in 2009. Last previous edition approved in 2016 as E2476 – 16. DOI:
10.1520/E2476-22. ization established in the Decision on Principles for the
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E2476 − 22
Development of International Standards, Guides and Recom- 4.2 This guidance only covers those aspects of risk assess-
mendations issued by the World Trade Organization Technical ment related to “risk to product quality.” Other aspects (such as
Barriers to Trade (TBT) Committee. “risk to patient”) should be covered in the conventional
manner.
2. Referenced Documents
5. Principles of Risk Assessment and Risk Control
2.1 ASTM Standards:
E2363 Terminology Relating to Manufacturing of Pharma-
5.1 Background—Risk management has been widely used
ceutical and Biopharmaceutical Products in the Pharma-
in manufacturing and service industries for many years. In
ceutical and Biopharmaceutical Industry
some industries, risk management has become formalized into
E2500 Guide for Specification, Design, and Verification of
a highly structured approach which has become the subject of
Pharmaceutical and Biopharmaceutical Manufacturing
standardization. This standardization has a number of benefits
Systems and Equipment
including:
E2629 Guide for Verification of Process Analytical Technol-
5.1.1 Widespread acceptance based on consensus among all
ogy (PAT) Enabled Control Systems
interested parties, which makes regulatory approval easier,
2.2 Other Standards and Guidance Documents:
5.1.2 Easy comparison of equivalent processes between
FDA Guidance for Industry PAT—A Framework for Inno-
sites, companies, and continents,
vative Pharmaceutical Development, Manufacturing, and
5.1.3 Ready transferability of skilled labor, and
Quality Assurance
5.1.4 Standardized training.
ICH Q8 (R2) Pharmaceutical Development
5.2 High-Level Characteristics of Risk Assessment—A risk
ICH Q9 Quality Risk Management
4 assessment for a PAT process has, in addition to the principles
ICH Q10 Pharmaceutical Quality System
outlined in ICH Q9, a number of key characteristics:
IEC 60812 Analysis Techniques for System Reliability—
5.2.1 It is systematic and structured.
Procedure for Failure Mode and Effects Analysis
5.2.2 It is primarily evidence-based. Evidence may include
(FMEA)
direct experience, historical knowledge, professional
IEC 61025 Fault Tree Analysis (FTA)
judgment, etc.
IEC 61882 Hazard and Operability Studies (HAZOP
5.2.3 It specifically focuses upon uncertainty or variability,
Studies)—Application Guide
or both, in product quality and the causes of such uncertainty/
ISO 22000 Food Safety Management Systems—
variability.
Requirements for any Organization in the Food Chain
5.2.4 It is an integral component of the decision-making
WHO Technical Report 908 WHO Expert Committee on
process.
Specifications for Pharmaceutical Preparations
5.2.5 It guides risk control and mitigation; that is, it recog-
3. Terminology
nizes that the primary consideration is product quality and
identifies those areas where risks must be reduced and provides
3.1 The terminology specific to this guide will be incorpo-
a mechanism for assessing when the risk has been sufficiently
rated into Terminology E2363.
reduced.
5.2.6 It is multi-layered. It can be applied at many levels,
4. Significance and Use
that is, lower-level, more detailed assessments feeding into
4.1 This guide is intended to provide guidance regarding the
higher-level, broader scope assessments. (For example, a
use of risk management in the development, day-to-day
higher-level risk assessment for the finished product will have
running, and continuous improvement of pharmaceutical pro-
lower-level risk assessments for each of the process stages
cesses incorporating Process Analytical Technology (PAT). A
which feed into it.) Breaking risk assessment into layers makes
consistent approach to the use of risk methodologies should be
complex evaluations simpler to perform, simpler to understand,
adopted to ensure rapid transfer of process understanding
and simplifies the generation of a detailed response. It also
within the development and manufacturing teams, and to the
assists in the process of identifying specific targets for reducing
regulators where that is appropriate.
the risk.
5.2.6.1 In general, an initial high-level risk assessment will
identify most of the high-risk areas. Subsequent lower-level
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM risk assessments, and resulting mitigation actions, will focus
Standards volume information, refer to the standard’s Document Summary page on
initially upon these identified areas of high risk, moving to
the ASTM website.
those areas of intermediate and lower risk at a later stage in the
Available from Food and Drug Administration (FDA), 5600 Fishers Ln.,
process. This later amelioration of the risk may be part of a
Rockville, MD 20857, http://www.fda.gov.
Available from International Council for Harmonisation of Technical Require-
continuous improvement process.
ments for Pharmaceuticals for Human Use (ICH), ICH Secretariat, P.O. Box 195,
5.2.7 It is dynamic and iterative. It will remain active for the
1211 Geneva 20, Switzerland, http://www.ich.org.
5 lifecycle of a product, responding to changing commercial,
Available from International Electrotechnical Commission (IEC), 3 rue de
Varembé, Case postale 131, CH-1211, Geneva 20, Switzerland, http://www.iec.ch. manufacturing, and scientific conditions and the availability of
Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
additional information or process understanding, or both.
4th Floor, New York, NY 10036, http://www.ansi.org.
Available from World Health Organization (WHO), https://www.who.int. 5.3 High-Level Characteristics of Risk Control:
E2476 − 22
5.3.1 Once risks have been clearly identified and prioritized, may result in a high risk remaining unaddressed at a particular
and the need for risk mitigation agreed, the process of risk stage, which then needs to be addressed by subsequent risk
control takes effect. Risk control has a number of key charac- control actions.
teristics: (4) Changing a process to reduce one risk may introduce
5.3.1.1 Risks which are identified during the assessment another risk. This risk, in turn, must be assessed and priori-
should receive a proportionate response. The response should tized.
be related to the probability of the event occurring, the severity
of the results, and the detectability of the event. 6. Preparation for Risk Assessment and Risk Control
5.3.1.2 Risk control actions for a new process occur in a
6.1 Adequate preparation is a key component of an effective
specific order:
risk assessment and risk control strategy.
(1) Perform design changes to reduce the risk. (That is,
6.2 Objectives of the Risk Assessment—To achieve timely,
enacting modifications to the basic process that deliver higher
effective results from a risk assessment and risk control
quality or more consistent product. This is a key reason for
process, the scope and objectives of the work shall be clearly
adopting PAT.)
defined at the earliest possible stage.
(2) Add control features to reduce the process risk. (That is,
putting extra features on the process the primary function of
6.3 Selection of the Risk Assessment/Control Group:
which is to reduce some facet of the risk, which is a key
6.3.1 The group assessing these risks shall include experi-
component of PAT.)
enced practitioners with all of the relevant key skills to identify
(3) Apply methods improving detectability (such as, stan-
and evaluate the key factors in the process under consideration.
dard operating procedures, guidelines, company practices, staff
The group should therefore include, or have direct access to,
training, staff selection, additional measurement systems, etc.)
subject matter experts with expertise or extensive experience in
to reduce risk.
appropriate areas such as:
5.3.1.3 For an existing process, the sequence may be differ-
6.3.1.1 Drug(s), intermediates, and excipients in the form
ent.
appropriate to the industry sector,
5.3.1.4 These actions should ideally be applied in the order
6.3.1.2 Design and function of the drug product,
listed. When a risk is identified, the design team should first
6.3.1.3 Scientific or technical issues, or both, of process
seek to remove the risk by changing the fundamental process
design,
design. If this is not possible, they should then seek to modify
6.3.1.4 Design and function of the process equipment,
equipment design or process conditions to reduce the risk.
6.3.1.5 Measurement systems,
Only if neither of these are practical should they use the third
6.3.1.6 Development of process and control models,
approach of imposing specific working practices. Some modi-
6.3.1.7 Design and function of process controls,
fication in this order may be necessary when an existing
6.3.1.8 Existing production,
process is being considered and the costs associated with
6.3.1.9 Current operating practices (including agreed work
fundamental design change are prohibitive.
rules and practices),
5.3.1.5 Once this process is complete, the remaining risks
6.3.1.10 Known problems with the product, either in manu-
are known as residual risks. Residual risks are:
facturing or subsequent use,
(1) Risks which remain higher than the acceptable risk
6.3.1.11 Company quality records and procedures,
level, but which cannot practicably be further reduced by
6.3.1.12 Company laboratory capabilities and practices,
redesign, risk control, or standard procedures/training/etc.
6.3.1.13 Recruitment and training policies in so far as they
When such risks occur, it will then be necessary to either
impact the process,
implement post-process risk mitigation measures such as
6.3.1.14 Company maintenance records and procedures,
off-line testing or decide to accept the residual risks (risk
and
acceptance). See ICH Q9.
6.3.1.15 Company validation practices and procedures or
5.3.1.6 Residual risks must be fully documented and should
continuous quality verification.
be subject to a formal acceptance procedure at least once
6.3.2 Individuals may fulfill one or more of these roles. It is
before final process approval.
not necessary for everyone to be present throughout the
5.3.1.7 It is recognized that, in the application of risk
assessment, but a core group that is involved throughout should
control:
be clearly identified.
(1) Changes must be viable in technical, regulatory, and
6.3.3 At least one member of the group should be fully
commercial contexts. Where changes do not meet these
trained to perform risk assessments.
criteria, it must be explicitly so stated in the risk report.
6.4 Collection and Preparation of Information—As far as is
(2) Reducing the risk on a process may still mean that the
process carries high risk after a particular stage. Subsequent possible, all relevant information necessary for the risk assess-
risk mitigation will be necessary. ment should be collected or prepared before the start of the
(3) Changing a process to reduce one risk may aggravate process. This helps to ensure that the assessment process does
another risk. The objective is to minimize the overall risk. This not become fragmented.
E2476 − 22
6.5 Consistency of Approach: 7.2.1 Risk assessment, as applied to PAT, is a systematic
6.5.1 The estimation of risk will usually be quasi- approach to identifying the variability of a process and any
quantitative, and, therefore, on an arbitrary scale. However it is associated hazard or failure mode, and it focuses and supports
important that measures are put in place to ensure that: the development process understanding. (Note that process
6.5.1.1 The estimation of risk is consistent from one project understanding includes product understanding.) It comprises a
to another, number of principle steps as shown in outline form below.
6.5.1.2 The estimation of risk is consistent from one assess-
7.2.2 It should be noted that, to maintain simplicity, the
ment team to another, and
process in Fig. 1 is shown as a single flow. In practice, risk
6.5.1.3 The estimation of risk is sufficiently transparent that
assessment will be ongoing throughout the full lifecycle of the
it can be readily understood by a third party assessor (such as
drug product. Documents such as the Risk Assessment report
a representative of a regulatory agency).
will therefore undergo continual revision, both during devel-
opment and as part of change control during the production
7. Application of Risk Assessment and Risk Control to phase.
PAT
7.2.3 There are three primary components of risk assess-
ment:
7.1 Objectives:
7.1.1 The advent of PAT has created a requirement for a 7.2.3.1 An understanding of the uncertainties of the process
(which includes materials, processing, equipment, personnel,
view of risk assessment which has a number of specific
objectives. environment, detection systems, feedback control, systems and
instrument accuracy, and repeatability),
7.1.1.1 The focus is upon risk to product quality (that is, the
quality of the end-product of the process).
7.2.3.2 An identification of the hazards and failure
7.1.1.2 The intent is to identify risks to product quality mechanisms, and
within the process and adopt measures to mitigate those risks
7.2.3.3 An estimation of the risks associated with each
until an acceptable quality is ensured. This means that all
hazard and failure.
identified risks must be minimized to an acceptable degree, and
7.2.4 Determination of Uncertainty in the Process and
residual risks must be explicitly identified and acknowledged.
Possible Failure Mechanisms:
7.1.1.3 The risk management occurs as an integral part of
7.2.4.1 Determination of the uncertainty in the manufactur-
the design, development, and operational phases of the process,
ing process requires a detailed and thorough understanding of
and it drives technical or methodological change where risk is
the components used within the manufacturing process, and of
assessed as unacceptable.
each of the various stages of that process. Since one of the
7.1.2 The objectives of the risk assessment process for PAT
objectives of PAT is to foster an increasingly accurate and
are to provide information to drive the following processes:
detailed understanding of the mechanical, physical, chemical,
7.1.2.1 Identification of the Critical Quality Attributes
and biological aspects of the manufacturing process, it is likely
(hereafter referred to as CQAs) both for the final drug product
that the sophistication of the risk assessment performed upon a
and the intermediate process products and the limits within
process will directly reflect the level of process understanding.
which they may acceptably vary (the CQAs are the primary
(1) Pharmaceutical manufacturing processes are, typically,
measurements of product quality),
complex, multi-stage operations which involve many different
7.1.2.2 Identification of those factors which can be adjusted
materials and items of equipment. To effectively analyze the
to control the variation in these CQAs, and hence those factors
risks associated with such a manufacturing operation, it is
which are important to the specification and design of the
necessary to break it down into simple stages (although care
process (see Guide E2500),
must also be taken to ensure that inter-dependencies and
7.1.2.3 Identification of those factors which may result in
interactions are also considered). These stages may be based
the final drug product or the intermediate process product not
upon individual processes, equipment, or components, or a
being imbued with desired CQAs during the process, including
combination thereof. Risk assessment should therefore start
the sources of variability in the CQAs, and,
with as many of the relevant items from the following list as is
7.1.2.4 Definition of a control strategy (see ICH Q10) to
possible:
ensure that the intermediate process products and the final drug
(a) A detailed map of the process flow (as a chemical/
product CQAs are held within the pre-defined limits during the
physical/biological process).
manufacture and lifecycle of the drug product.
(b) An evaluation of the thermodynamics, physical/
7.1.3 It is important that the risk assessment process is
chemical/biological behavior, mass balance, etc. of any critical
clearly focused upon the intermediate process product and final
process stage.
drug product CQAs to ensure that the effort required to
(c) An evaluation of the physical/chemical/biological
undertake the risk assessment does not become excessive.
risks of any potentially harmful product (main, by-, or waste-)
Nevertheless, there are two distinct categories in this list: the
of the process.
determination of the CQAs, and the determination of how to
(d) Known physical, chemical, and biological variability
measure and control the CQAs. These two topics are dealt with
of all raw and process materials used (including variability in
independently in Sections 8 and 9.
physical, chemical, or biological stability).
7.2 Basic Concepts of Risk Assessment When Applied to (e) A detailed list of equipment used (including equip-
PAT: ment for measuring, processing, moving, containment, etc.).
E2476 − 22
FIG. 1 Basic Application of Risk Assessment to PAT
(f) Manufacturer’s specifications and recommendations (1) A detailed map of material flow including storage
for use for all the above. conditions and hold times.
(g) Maintenance requirements.
(2) A detailed list of critical and non-critical equipment.
(h) A process flow (as an equipment map).
(3) Equipment power-up.
(i) A list of required utilities.
(4) Initialization.
(j) Information on prior failures of the process being
(5) Testing.
considered, or, where this is not
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2476 − 16 E2476 − 22
Standard Guide for
Risk Assessment and Risk Control as it Impacts the Design,
Development, and Operation of PAT Processes for
Pharmaceutical Manufacture
This standard is issued under the fixed designation E2476; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
This document provides guidance on the implementation of risk assessment and risk control for
Process Analytical Technology (PAT) processes within the pharmaceutical industry. Wherever
possible, other appropriate standards on risk assessment/management have been referenced and
acknowledged. Where practical, further details of methods and additional references have been
provided for information within the appendixes.
The application of risk assessment and risk control is pivotal to the creation of PAT systems, which
are described as “science-based” and “risk-based.” Such application starts at an early stage in the
development of the process and continues throughout development and production. In the production
phase, it is a crucial component of applying continuous improvement to the process.
RELATIONSHIP TO ICH Q9
The ICH International Council for Harmonisation of Technical Requirements for Pharmaceuticals
for Human Use (ICH) Q9 Guideline for Quality Risk Management is intended for general application
within the pharmaceutical industry. ICH Q9 describes the requirements for pharmaceutical quality risk
management and considers the risk as “risk to the patient.”
This document provides specific guidance on the risk assessment and risk control phases identified
in ICH Q9 in a limited set of conditions. It is applicable where the manufacturing method is compliant
with Process Analytical Technology (PAT) principles, and where the primary considerations are
product quality and reduction of process and product variability. The only component of risk to patient
considered here is risk to product quality. Other components fall outside the scope of the document.
In addition, other areas identified in ICH Q9, such as general risk management and risk
communication, are not considered here.
This document provides guidance which applies to the design, development, and operation of PAT
systems. It should be considered as a specific extension, supporting the ICH Q9 guidance for these
processes.
1. Scope
1.1 This document provides guidance on the assessment of risks to product quality within and related to PAT processes in the
pharmaceutical industry. It addresses those risks to product quality arising from, associated with, identified by, or modified by the
implementation of PAT in pharmaceutical development and manufacturing for primary, secondary, and biotech sectors of the
This guide is under the jurisdiction of ASTM Committee E55 on Manufacture of Pharmaceutical and Biopharmaceutical Products and is the direct responsibility of
Subcommittee E55.01 on Process Understanding and PAT System Management, Implementation and Practice.
Current edition approved Nov. 1, 2016Nov. 1, 2022. Published November 2016December 2022. Originally approved in 2009. Last previous edition approved in 20092016
as E2476 – 09.E2476 – 16. DOI: 10.1520/E2476-16.10.1520/E2476-22.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E2476 − 22
industry. It does not replace those assessments of risk currently undertaken by pharmaceutical companies, but is, rather, an
additional component focused specifically upon the evaluation and design of PAT processes. See Practice E2474, Guide E2500,
and ICH Q8.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use. Note that safety in this context refers to operational and operator safety, not
to patient safety.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2.1 ASTM Standards:
E2474E2363 Practice for Pharmaceutical Process Design Utilizing Process Analytical TechnologyTerminology Relating to
Process Analytical Technology in the Pharmaceutical Industry (Withdrawn 2020)
E2500 Guide for Specification, Design, and Verification of Pharmaceutical and Biopharmaceutical Manufacturing Systems and
Equipment
E2363E2629 Terminology Relating to Guide for Verification of Process Analytical Technology in the Pharmaceutical
Industry(PAT) Enabled Control Systems
2.2 Other Standards:Standards and Guidance Documents:
FDA Guidance for Industry PAT—A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality
Assurance
ICH Q8 (R2) Pharmaceutical Development
ICH Q9 Quality Risk Management
ICH Q10 Pharmaceutical Quality System
IEC 60812 Analysis Techniques for System Reliability—Procedure for Failure Mode and Effects Analysis (FMEA)
IEC 61025 Fault Tree Analysis (FTA)
IEC 61882 Hazard and Operability Studies (HAZOP Studies)—Application Guide
ISO 22000 Food Safety Management Systems—Requirements for any Organization in the Food Chain
WHO Technical Report 908 WHO Expert Committee on Specifications for Pharmaceutical Preparations
3. Terminology
3.1 The terminology specific to this guide will be incorporated into Terminology E2363.
4. Significance and Use
4.1 This guide is intended to provide guidance regarding the use of risk management in the development, day-to-day running, and
continuous improvement of pharmaceutical processes incorporating Process Analytical Technology (PAT). Since PAT is defined as
being “risk-based” (see FDA Guidance for Industry), it is important that a A consistent approach to the use of risk methodologies
is adopted, should be adopted to ensure rapid transfer of process understanding within the development and manufacturing teams,
and to the regulators where that is appropriate.
4.2 This guidance only covers those aspects of risk assessment related to “risk to product quality.” Other aspects (such as “risk
to patient”) should be covered in the conventional manner.
5. Principles of Risk Assessment and Risk Control
5.1 Background—Risk management has been widely used in manufacturing and service industries for many years. In some
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Available from Food and Drug Administration (FDA), 5600 Fishers Ln., Rockville, MD 20857, http://www.fda.gov.
Available from International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), ICH Secretariat, P.O. Box 195, 1211
Geneva 20, Switzerland, http://www.ich.org.
Available from International Electrotechnical Commission (IEC), 3 rue de Varembé, Case postale 131, CH-1211, Geneva 20, Switzerland, http://www.iec.ch.
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
Available from World Health Organization (WHO), https://www.who.int.
E2476 − 22
industries, risk management has become formalized into a highly structured approach which has become the subject of
standardization. This standardization has a number of benefits including:
5.1.1 Widespread acceptance based on consensus among all interested parties, which makes regulatory approval easier,
5.1.2 Easy comparison of equivalent processes between sites, companies, and continents,
5.1.3 Ready transferability of skilled labor, and
5.1.4 Standardized training.
5.2 High-Level Characteristics of Risk Assessment—A risk assessment for a PAT process has, in addition to the principles outlined
in ICH Q9, a number of key characteristics:
5.2.1 It is systematic and structured.
5.2.2 It is primarily evidence-based. Evidence may include direct experience, historical knowledge, professional judgment, etc.
5.2.3 It specifically focuses upon uncertainty or variability, or both, in product quality and the causes of such uncertainty/
variability.
5.2.4 It is an integral component of the decision-making process.
5.2.5 It guides risk control and mitigation; that is, it recognizes that the primary consideration is product quality and identifies
those areas where risks must be reduced and provides a mechanism for assessing when the risk has been sufficiently reduced.
5.2.6 It is multi-layered. It can be applied at many levels, that is, lower-level, more detailed assessments feeding into higher-level,
broader scope assessments. (For example, a higher-level risk assessment for the finished product will have lower-level risk
assessments for each of the process stages which feed into it.) Breaking risk assessment into layers makes complex evaluations
simpler to perform, simpler to understand, and simplifies the generation of a detailed response. It also assists in the process of
identifying specific targets for reducing the risk.
5.2.6.1 In general, an initial high-level risk assessment will identify most of the high-risk areas. Subsequent lower-level risk
assessments, and resulting mitigation actions, will focus initially upon these identified areas of high risk, moving to those areas
of intermediate and lower risk at a later stage in the process. This later amelioration of the risk may be part of a continuous
improvement process.
5.2.7 It is dynamic and iterative. It will remain active for the lifecycle of a product, responding to changing commercial,
manufacturing, and scientific conditions and the availability of additional information or process understanding, or both.
5.3 High-Level Characteristics of Risk Control:
5.3.1 Once risks have been clearly identified and prioritized, and the need for risk mitigation agreed, the process of risk control
takes effect. Risk control has a number of key characteristics:
5.3.1.1 Risks which are identified during the assessment should receive a proportionate response. The response should be related
to the probability of the event occurring, the severity of the results, and the detectability of the event.
5.3.1.2 Risk control actions for a new process occur in a specific order:
(1) Perform design changes to reduce the risk. (That is, enacting modifications to the basic process that deliver higher quality
or more consistent product. This is a key reason for adopting PAT.)
(2) Add control features to reduce the process risk. (That is, putting extra features on the process the primary function of which
is to reduce some facet of the risk, which is a key component of PAT.)
(3) Apply methods improving detectability (such as, standard operating procedures, guidelines, company practices, staff
training, staff selection, additional measurement systems, etc.) to reduce risk.
5.3.1.3 For an existing process, the sequence may be different.
E2476 − 22
5.3.1.4 These actions should ideally be applied in the order listed. When a risk is identified, the design team should first seek to
remove the risk by changing the fundamental process design. If this is not possible, they should then seek to modify equipment
design or process conditions to reduce the risk. Only if neither of these are practical should they use the third approach of imposing
specific working practices. Some modification in this order may be necessary when an existing process is being considered and
the costs associated with fundamental design change are prohibitive.
5.3.1.5 Once this process is complete, the remaining risks are known as residual risks. Residual risks are:
(1) Risks which remain higher than the acceptable risk level, but which cannot practicably be further reduced by redesign, risk
control, or standard procedures/training/etc. When such risks occur, it will then be necessary to either implement a post-process
risk mitigation measures such as off-line testing.testing or decide to accept the residual risks (risk acceptance). See ICH Q9.
5.3.1.6 Residual risks must be fully documented and should be subject to a formal acceptance procedure at least once before final
process approval.
5.3.1.7 It is recognized that, in the application of risk control:
(1) Changes must be viable in technical, regulatory, and commercial contexts. Where changes do not meet these criteria, it must
be explicitly so stated in the risk report.
(2) Reducing the risk on a process may still mean that the process carries high risk after a particular stage. Subsequent risk
mitigation will be necessary.
(3) Changing a process to reduce one risk may aggravate another risk. The objective is to minimize the overall risk. This may
result in a high risk remaining unaddressed at a particular stage, which then needs to be addressed by subsequent risk control
actions.
(4) Changing a process to reduce one risk may introduce another risk. This risk, in turn, must be assessed and prioritized.
6. Preparation for Risk Assessment and Risk Control
6.1 Adequate preparation is a key component of an effective risk assessment and risk control strategy.
6.2 Objectives of the Risk Assessment—To achieve timely, effective results from a risk assessment and risk control process, the
scope and objectives of the work shall be clearly defined at the earliest possible stage.
6.3 Selection of the Risk Assessment/Control Group:
6.3.1 The group assessing these risks shall include experienced practitioners with all of the relevant key skills to identify and
evaluate the key factors in the process under consideration. The group should therefore include, or have direct access to, subject
matter experts with expertise or extensive experience in appropriate areas such as:
6.3.1.1 Drug(s), intermediates, and excipients in the form appropriate to the industry sector,
6.3.1.2 Design and function of the drug product,
6.3.1.3 Scientific or technical issues, or both, of process design,
6.3.1.4 Design and function of the process equipment,
6.3.1.5 Measurement systems,
6.3.1.6 Development of process and control models,
6.3.1.7 Design and function of process controls,
6.3.1.8 Existing production,
6.3.1.9 Current operating practices (including agreed work rules and practices),
6.3.1.10 Known problems with the product, either in manufacturing or subsequent use,
E2476 − 22
6.3.1.11 Company quality records and procedures,
6.3.1.12 Company laboratory capabilities and practices,
6.3.1.13 Recruitment and training policies in so far as they impact the process,
6.3.1.14 Company maintenance records and procedures, and
6.3.1.15 Company validation practices and procedures or continuous quality verification.
6.3.2 Individuals may fulfill one or more of these roles. It is not necessary for everyone to be present throughout the assessment,
but a core group that is involved throughout should be clearly identified.
6.3.3 At least one member of the group should be fully trained to perform risk assessments.
6.4 Collection and Preparation of Information—As far as is possible, all relevant information necessary for the risk assessment
should be collected or prepared before the start of the process. This helps to ensure that the assessment process does not become
fragmented.
E2476 − 22
6.5 Consistency of Approach:
6.5.1 The estimation of risk will usually be quasi-quantitative, and, therefore, on an arbitrary scale. However it is important that
measures are put in place to ensure that:
6.5.1.1 The estimation of risk is consistent from one project to another,
6.5.1.2 The estimation of risk is consistent from one assessment team to another, and
6.5.1.3 The estimation of risk is sufficiently transparent that it can be readily understood by a third party assessor (such as a
representative of a regulatory agency).
7. Application of Risk Assessment and Risk Control to PAT
7.1 Objectives:
7.1.1 The advent of PAT has created a requirement for a view of risk assessment which has a number of specific objectives.
7.1.1.1 The focus is upon risk to product quality (that is, the quality of the end-product of the process).
7.1.1.2 The intent is to identify risks to product quality within the process and adopt measures to mitigate those risks until an
acceptable quality is ensured. This means that all identified risks must be minimized to an acceptable degree, and residual risks
must be explicitly identified and acknowledged.
7.1.1.3 The risk management occurs as an integral part of the design, development, and operational phases of the process, and it
drives technical or methodological change where risk is assessed as unacceptable.
7.1.2 The objectives of the risk assessment process for PAT are to provide information to drive the following processes:
7.1.2.1 Identification of the Critical Quality Attributes (hereafter referred to as CQAs) both for the final drug product and the
intermediate process products and the limits within which they may acceptably vary (the CQAs are the primary measurements of
product quality),
7.1.2.2 Identification of those factors which can be adjusted to control the variation in these CQAs, and hence those factors which
are important to the specification and design of the process (see Practice E2474 and Guide E2500),
7.1.2.3 Identification of those factors which may result in the final drug product or the intermediate process product not being
imbued with desired CQAs during the process, including the sources of variability in the CQAs, and,
7.1.2.4 Definition of a control strategy (see ICH Q10) to ensure that the intermediate process products and the final drug product
CQAs are held within the pre-defined limits during the manufacture and lifecycle of the drug product.
7.1.3 It is important that the risk assessment process is clearly focused upon the intermediate process product and final drug
product CQAs to ensure that the effort required to undertake the risk assessment does not become excessive. Nevertheless, there
are two distinct categories in this list: the determination of the CQAs, and the determination of how to measure and control the
CQAs. These two topics are dealt with independently in Sections 8 and 9.
E2476 − 22
7.2 Basic Concepts of Risk Assessment When Applied to PAT:
7.2.1 Risk assessment, as applied to PAT, is a systematic approach to identifying the variability of a process and any associated
hazard or failure mode, and it focuses and supports the development process understanding. (Note that process understanding
includes product understanding.) It comprises a number of principle steps as shown in outline form below.
7.2.2 It should be noted that, to maintain simplicity, the process in Fig. 1 is shown as a single flow. In practice, risk assessment
will be ongoing throughout the full lifecycle of the drug product. Documents such as the Risk Assessment report will therefore
undergo continual revision, both during development and as part of change control during the production phase.
7.2.3 There are three primary components of risk assessment:
7.2.3.1 An understanding of the uncertainties of the process (which includes materials, processing, equipment, personnel,
environment, detection systems, feedback control, systems and instrument accuracy, and repeatability),
7.2.3.2 An identification of the hazards and failure mechanisms, and
7.2.3.3 An estimation of the risks associated with each hazard and failure.
7.2.4 Determination of Uncertainty in the Process and Possible Failure Mechanisms:
7.2.4.1 Determination of the uncertainty in the manufacturing process requires a detailed and thorough understanding of the
components used within the manufacturing process, and of each of the various stages of that process. Since one of the objectives
of PAT is to foster an increasingly accurate and detailed understanding of the mechanical, physical, chemical, and biological
aspects of the manufacturing process, it is likely that the sophistication of the risk assessment performed upon a process will
directly reflect the level of process understanding.
Pharmaceutical manufacturing processes are, typically, complex, multi-stage operations which involve many different materials
and items of equipment. To effectively analyze the risks associated with such a manufacturing operation, it is necessary to break
it down into simple stages (although care must also be taken to ensure that inter-dependencies and interactions are also considered).
FIG. 1 Basic Application of Risk Assessment to PAT
E2476 − 22
These stages may be based upon individual processes, equipment, or components, or a combination thereof. Risk assessment
should therefore start with as many of the relevant items from the following list as is possible:
(1) A detailed map of the process flow (as a chemical/physical/biological process).Pharmaceutical manufacturing processes are,
typically, complex, multi-stage operations which involve many different materials and items of equipment. To effectively analyze
the risks associated with such a manufacturing operation, it is necessary to break it down into simple stages (although care must
also be taken to ensure that inter-dependencies and interactions are also considered). These stages may be based upon individual
processes, equipment, or components, or a combination thereof. Risk assessment should therefore start with as many of the relevant
items from the following list as is possible:
(2) An evaluation of the thermodynamics, physical/chemical/biological behavior, mass balance, etc. of any critical process
stage.
(a) A detailed map of the process flow (as a chemical/physical/biological process).
(b) An evaluation of the thermodynamics, physical/chemical/biological behavior, mass balance, etc. of any critical process
stage.
(c) An evaluation of the physical/chemical/biological risks of any potentially harmful product (main, by-, or waste-) of the
process.
(d) Known physical, chemical, and biological variability of all raw and process materials used (including variability in
physical, chemical, or biological stability).
(e) A detailed list of equipment used (including equipment for measuring, processing, moving, containment, etc.).
(f) Manufacturer’s specifications and recommendations for use for all the above.
(g) Maintenance requirements.
(h) A process flow (as an equipment map).
(i) A list of required utilities.
(j) Information on prior failures of the process being considered, or, where this is not available, prior failures of closely related
processes.
(k) Information on any accident or malfunction on the actual or an equivalent piece of equipment.
(l) Current process measurements and methodologies (including Standard Operating Procedures).
(m) IT infrastructure.
(n) Data handling.
(o) Purchasing policies and procedures in so far as they affect system uncertainty.
(p) QA policies and procedures in so far as they affect system uncertainty.
(q) Information regarding suppliers in so far as it affects system uncertainty.
(r) Information regarding the use of equipment, including training, agreed work practices, operating constraints, etc.
(s) Requirements for staff professional skills or training, or both.
(3) An evaluation of the physical/chemical/biological risks of any potentially harmful product (main, by-, or waste-) of the
process.
(4) Known physical, chemical, and biological variability of all
...