M/347 - Measuring instruments
Programming mandate to CEN, CENELEX and ETSI relating to measuring instruments
General Information
This part of IEC 62058 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated electromechanical meters for active energy (classes 0,5, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer. The process described herein is primarily intended for acceptance inspection between the manufacturer and the purchaser.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
The general acceptance inspection methods specified in this part of IEC 62058 apply to newly manufactured electricity meters produced and supplied in lots of 50 and above.
- Standard91 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62058 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer. The process described herein is primarily intended for acceptance inspection between the manufacturer and the purchaser.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured electromechanical watt-hour meters intended for residential, commercial and light industrial use, of class indexes A and B, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and type test methods. It applies to electromechanical watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between: -meters of class indexes A and B; -direct connected and transformer operated meters;;meters for use in networks equipped with or without earth fault neutralizers. It does not apply to: -watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); -portable meters. Methods for acceptance testing are covered by the IEC 62058 series of standards. The dependability aspect is covered by the documents of the IEC 62059 series.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured watt-hour meters, measuring active electrical energy, intended for residential, commercial and light industrial use, for use on 50 Hz electrical networks. It specifies general requirements and type tests methods. It applies to electromechanical or static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between:-electromechanical and static meters; -meters of class indexes A, B and C;-direct connected and transformer operated meters;-protective class I and protective class II meters;-meters intended to be used indoors and outdoors. It does not apply to:-watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems);-portable meters;-reference meters. For rack-mounted meters, the mechanical properties are not covered in this standard. The test levels are regarded as minimum values to guarantee the proper functioning of the meter under normal working conditions. For special applications, other test levels might be necessary and should be agreed on between the user and the manufacturer.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured static watt-hour meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and type test methods. It applies to static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62058-31:2008 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62058-11:2008 specifies the general acceptance inspection methods which apply to newly manufactured electricity meters produced and supplied in lots of 50 and above.
- Standard91 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62058-21:2008 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated electromechanical meters for active energy (classes 0,5, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured electromechanical watt-hour meters intended for residential, commercial and light industrial use, of class indexes A and B, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and type test methods. It applies to electromechanical watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between: – meters of class indexes A and B; – direct connected and transformer operated meters; – meters for use in networks equipped with or without earth fault neutralizers. It does not apply to: – watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); – portable meters. Methods for acceptance testing are covered by the IEC 62058 series of standards 1). The dependability aspect is covered by the documents of the IEC 62059 series.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured static watt-hour meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and type test methods. It applies to static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between: – meters of class indexes A, B and C; – direct connected and transformer operated meters; – meters for use in networks equipped with or without earth fault neutralizers. It does not apply to: – watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); – portable meters; – reference meters. Methods for acceptance testing are covered by the IEC 62058 series of standards. The dependability aspect is covered by the documents of the IEC 62059 series.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to newly manufactured watt-hour meters, measuring active electrical energy, intended for residential, commercial and light industrial use, for use on 50 Hz electrical networks. It specifies general requirements and type tests methods. It applies to electromechanical or static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between: – electromechanical and static meters; – meters of class indexes A, B and C; – direct connected and transformer operated meters; – protective class I and protective class II meters; – meters intended to be used indoors and outdoors. It does not apply to: – watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); – portable meters; – reference meters. For rack-mounted meters, the mechanical properties are not covered in this standard. The test levels are regarded as minimum values to guarantee the proper functioning of the meter under normal working conditions. For special applications, other test levels might be necessary and should be agreed on between the user and the manufacturer.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day