29.080.99 - Other standards related to insulation
ICS 29.080.99 Details
Other standards related to insulation
Weitere Isolierungen
Autres normes relatives a l'isolation
Drugi standardi v zvezi z izolacijo
General Information
IEC 63177:2024 specifies the test method for the compatibility of construction materials with electrical insulating liquids for use in electrical equipment, such as liquid-immersed transformers and tap-changers, liquid-impregnated capacitors, and liquid-cooled rotating machines used in electrical vehicles and oil pumps. This document is applicable to mineral insulating liquids, natural esters, silicone insulating liquids, synthetic organic esters, modified esters, capacitor fluids based on synthetic aromatic hydrocarbons and e-transmission fluids used in electrical vehicles and oil pumps. The compatibility tests are not sufficient for a full qualification of construction materials for a given application without additional tests requested by the appropriate IEC Technical Committee or equipment manufacturers.
- Standard38 pagesEnglish and French languagesale 15% off
IEC 62561-3:2023 is available as IEC 62561-3:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62561-3:2023 specifies the requirements and tests for isolating spark gaps (ISGs) for lightning protection systems. ISGs can be used to indirectly bond a lightning protection system to other nearby metalwork where a direct bond is not permissible for functional reasons. This third edition cancels and replaces the second edition, published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) alignment with the latest edition of ISO 22479 relating to humid sulphurous atmosphere treatment;
b) addition of a new normative Annex D for the applicability of previous tests.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60372:2020 is applicable to locking devices used with ball and socket couplings of string insulator units and used with the corresponding metal fittings standardized in IEC 60120, when they are supplied separately.The object of this document is
- to define the shapes and some standard dimensions for locking devices,
- to define the test methods for locking devices,
- to state the acceptance conditions for supply,
- to give other dimensions for guidance of manufacturing only.
This fourth edition cancels and replaces the third edition published in 1984. This edition includes the following significant technical changes with respect to the previous edition:
a. Two new designated size of couplings, 36 and 40, were introduced;
b. the relevant content of the 28B W-clip was deleted;
c. Annex A is informative, Annex B is normative, Annex C is informative.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-3:2017(E) specifies the requirements and tests for isolating spark gaps (ISG) for lightning protection systems.
ISGs can be used to indirectly bond a lightning protection system to other nearby metalwork where a direct bond is not permissible for functional reasons.
This second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition.
- a new classification has been added related to ISGs location installation;
- an updated flow chart of tests has been developed.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
IEC TS 60079-46:2017 specifies requirements for the design, construction, assembly, testing, inspection, marking, documenting and assessment of equipment assemblies for use in explosive atmospheres under the responsibility of the manufacturer of the equipment assembly. The requirements of this document apply to individual items according to the IEC 60079 series or ISO 80079 series that comprise the assembly and that have individual certificates. These individual items are then integrated as part of the equipment assembly. Also included are requirements to address aspects for the assembly which may be beyond the certificates of the individual items forming the assembly. The scope of this document includes assessment of the additional requirements for assemblies for hazardous areas and does not include requirements for non-hazardous areas. It is assumed that compliance with other electrical or mechanical requirements that are applicable for non-hazardous areas will be verified by either the same or different party in addition to the requirements of this document. This document does not apply to:
- equipment which is covered, in its entirety, by one or more IEC 60079 and ISO 80079 equipment types of protection;
- pressurized rooms, “p”, in accordance with IEC 60079-13, artificial ventilation for the protection of analyzer(s) houses in accordance with IEC TR 60079-16, and other standards addressing specific Ex assemblies;
- installation at the end-user site under the scope of IEC 60079-14;
- classification of the hazardous area;
- equipment assemblies for mines susceptible to firedamp (Group I applications);
- inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
- rooms used for medical purposes;
- electrical installations in areas where the hazard is due to flammable mist.
The specification is only intended to provide validation for the initial supply of an assembly.
Keywords: equipment assemblies for use in explosive atmospheres
- Technical specification16 pagesEnglish languagesale 15% off
- Technical specification33 pagesEnglish and French languagesale 15% off
IEC 63177:2024 specifies the test method for the compatibility of construction materials with electrical insulating liquids for use in electrical equipment, such as liquid-immersed transformers and tap-changers, liquid-impregnated capacitors, and liquid-cooled rotating machines used in electrical vehicles and oil pumps. This document is applicable to mineral insulating liquids, natural esters, silicone insulating liquids, synthetic organic esters, modified esters, capacitor fluids based on synthetic aromatic hydrocarbons and e-transmission fluids used in electrical vehicles and oil pumps. The compatibility tests are not sufficient for a full qualification of construction materials for a given application without additional tests requested by the appropriate IEC Technical Committee or equipment manufacturers.
- Draft17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63177:2024 specifies the test method for the compatibility of construction materials with electrical insulating liquids for use in electrical equipment, such as liquid-immersed transformers and tap-changers, liquid-impregnated capacitors, and liquid-cooled rotating machines used in electrical vehicles and oil pumps. This document is applicable to mineral insulating liquids, natural esters, silicone insulating liquids, synthetic organic esters, modified esters, capacitor fluids based on synthetic aromatic hydrocarbons and e-transmission fluids used in electrical vehicles and oil pumps. The compatibility tests are not sufficient for a full qualification of construction materials for a given application without additional tests requested by the appropriate IEC Technical Committee or equipment manufacturers.
- Draft17 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard10 pagesEnglish and French languagesale 15% off
Gives guidance for the interpretation of dissolved gas analysis (DGA) which has been developed for bushings, in service, where the main insulation (generally paper) is impregnated with mineral insulating oil according to IEC 60296. Is applicable to oil-filled and impregnated paper bushings in service. The contents of the corrigendum of January 2003 have been included in this copy.
- Technical specification31 pagesEnglish and French languagesale 15% off
- Technical specification31 pagesEnglish and French languagesale 15% off
This European Standard applies to: Fixed installations (downstream the secondary of the substation transformer) and rolling stock equipment linked to the contact line of one of the systems defined in EN 50163; Rolling stock equipment linked to a train line. This standard gives simulation and/or test requirements for protection against transient overvoltages of such equipment. Long-term overvoltages are not treated in this document.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day





