ISS EIT.ERE - All-or-nothing electrical relays
Standardization in the field of all-or-nothing electrical relays used in the various fields of Electrical Engineering, normally produced in very large numbers as components of electromechanical or electronic equipment.
Električni releji
Standardizacija na področju uporabe električnih relejev v različnih področjih elektrotehnike in ki jih izdelujejo v velikem številu kot sestavne dele elektromehanske in elektronske opreme.
General Information
IEC 63522-10:2025 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for heating.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-1:2025 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of specimens to perform under expected conditions of transportation, storage, and all aspects of operational use.
The object of this test is to define a standard test method for the visual inspection and check of dimensions.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-33:2025 This part of IEC 63522 is used for testing all kind of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document provides test methods to ensure that the connection between an earthing terminal and parts required to be connected thereto is of low resistance.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-34:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document provides tests to ensure that a relay is suitable for use when subjected to contamination by fluids found in aerospace applications and similar. This test applies to RT III to RT V relays only.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-31:2025 This part of IEC 63522 is used for testing all kind of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to investigate the effect of remanence in the magnetic circuit of relays with DC coil.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-54:2025 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for critical DC load current test.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-21:2025 This part is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for evaluation of resistance against high temperature for long periods.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-30:2025 defines a standard test method to determine contact sticking of relays as part of the normal service life, i.e., devices under test (DUTs) fail to open within a specified time, due to, for example, effects of remanence, chemical effects, or high temperature. It does not cover contact sticking during or after electrical endurance testing or due to other validation tests for relays.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-45:2025 used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combination of these) and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-29:2025 This part is used for testing the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
It specifies how to ensure that the capacitances formed by parts of a relay do not exceed specified limits.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-2:2025 This part is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method to ensure that particular mechanical properties (such as contact force, armature travel, contact gaps) and weight, are within specified limits.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-5:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for insulation resistance.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-18:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this test is to determine the thermal resistance of the relay coil.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-38:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for mechanical interlock.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-20:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for mechanical endurance.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-56:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of specimens to perform under expected conditions of transportation, storage and all aspects of operational use.
The object of this test is to define a standard test method for evaluation of appropriate materials to withstand mechanical pressure at elevated temperatures without undue deformation.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-24:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a test to check that a multipole relay is capable of transferring one source to another.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-28:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for thermoelectric electromotive force (e.m.f.).
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-22:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for evaluation of the limiting continuous current under specified conditions.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-9:2025 This document used for testing all kinds of relays and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use. It defines standard test methods to determine the ability of the relay to withstand certain climatic test conditions, a sequence of such climatic test conditions or climatic storage conditions.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-49:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for long term stability of sealing.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-40:2025 This document is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for short circuit testing.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-27:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for electrical contact noise.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-16:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for resistance to soldering heat and solderability for standard soldering processes.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-44:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this test is to define a standard test method for salt mist.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-37:2025 This part of lEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this document is to define a standard test method to measure terminal temperature rise at rated load, included solder terminals, flat quick-connect terminations, screw and screwless type terminals, alternative termination types and sockets.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-7:2025 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combination of these) and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to evaluate the switching function of the device under test (DUT) at specified energization values throughout the defined temperature range.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-32:2025 This document is used for testing under appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method to investigate the effect of acoustic noise in conjunction with the operating, releasing and cycling noise of a relay and the immunity of a relay to acoustic noise.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-25:2025 Used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to check the magnetic interference between relays under operating conditions and their influence on other relays in the neighbourhood.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-36:2025 is used for testing all kinds of relays and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use.
This document defines a standard test method to measure fire hazards of all materials susceptible to fire hazards.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60255-27:2023 specifies the product safety requirements for measuring relays and protection equipment having a rated AC voltage up to 1 000 V, or a rated DC voltage up to 1 500 V. This document specifies essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user and property. This document specifies only product safety requirements; functional performance of the equipment is not covered. This document covers all the ways in which the equipment can be mounted and used in cabinets, racks and panels. This document also applies to auxiliary devices such as shunts, series resistors, transformers, auxiliary control panels, display devices, etc., that are used in conjunction with measuring relays and protection equipment and are tested together.
- Standard103 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-35:2025 is used for testing all kind of relays within the scope of technical committee 94 and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for resistance to cleaning solvents.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 General
This part of the IEC 60255 series specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. It is applicable to measuring relays and protection equipment and combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems.
Tests specified in this document are not required for equipment not incorporating electronic circuits, for example electromechanical relays.
The requirements specified in this document are applicable to measuring relays and protection equipment in a condition representative of how new equipment is provided by the manufacturer. All tests specified are type tests only.
1.2 Emission
This document specifies limits and test methods, for measuring relays and protection equipment in relation to electromagnetic emissions which might cause interference in other equipment.
These emission limits represent electromagnetic compatibility requirements and have been selected to ensure that the disturbances generated by measuring relays and protection equipment, operated normally in substations and power plants, do not exceed a specified level which could prevent other equipment from operating as intended.
Test requirements are specified for the enclosure, auxiliary power supply ports, input/output ports, signal/control ports and wired network ports.
1.3 Immunity
This document specifies the immunity test requirements for measuring relays and protection equipment in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.
These test requirements represent the electromagnetic compatibility immunity requirements and have been selected so as to ensure an adequate level of immunity for measuring relays and protection equipment, operated normally in substations and power plants.
NOTE 1 Product safety considerations are not covered in this document.
NOTE 2 In special cases, situations will arise where the levels of disturbance could exceed the levels specified in this document, for example where a hand-held transmitter or a mobile telephone is used close to measuring relays and protection equipment. In these instances, special precautions and procedures could have to be employed.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-6:2025 is used for testing all kinds of relays and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use.
This document defines a standard test method to measure contact-circuit resistance or voltage drop.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-39:2025 is used for testing all kind of relays and shall evaluate their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines standard test methods for:
1. measuring the insertion and withdrawal forces of the mating relay and socket;
2. measuring the insertion and withdrawal forces on relays with flat quickconnect terminations;
3. verifying the correct connection of flat terminals with eye lug connectors.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-11:2025 is used for testing electrical relay enclosures along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines standard test methods for appropriate enclosure sealing testing.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-14:2025 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a test for determining the extent to which electrical relays support mould growth and how any mould growth can affect the performance and other relevant properties/functions of a relay.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-12:2025 Used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combination of these) and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use.
This document defines a standard test method to provoke internal moisture inside relays by different methods. The device under test (DUT) is tested at its specified energization values throughout the defined temperature range.
The test methods in this document are applicable to RT III, RT IV and RT V products only, i.e., wash-tight, sealed, and hermetically sealed DUTs.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-13:2024 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combinations of these) and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to simulate impacts of sulfuric atmospheres to relays. The test conditions simulate an artificial situation and allow a performance comparison for usability of the devices under test (DUT) with regard to known and existing switching solutions.
The test is a static test without actual operation of the DUT to simulate a worst-case scenario for corrosion, since corrosion increases over time. The corrosion layer can potentially create contact sticking, increase resistance or other undesired effects in the relay. Those aspects can be affected by DUT actuations during the test, which can destroy the corrosion layers or hide relevant long-term effects.
In addition to polluted atmospheres, the suitability of the DUT for use and/or storage in corrosive atmospheres can be assessed in a salt-laden atmosphere as described in IEC 63522-44.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-48:2024 is used for for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combinations of these) and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for contact failure rate test of electromechanical elementary relays applied to low-load applications (e.g., CC 0, CC 1) and failure rates and failure rate levels at low loads under specified conditions.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-15:2024 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combination of these) and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method that applies defined loads to relay terminals (direct axial pulls, bending or twisting) as they can be present in assembled configurations or during handling. In addition, it covers torque stress for nuts and threaded terminals as they are likely to be experienced during normal assembly operations.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-17:2024 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combination of these) and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to simulate the mechanical stress on relays as it can occur in service, during handling or during transportation. This document comprises test procedures to simulate shock impacts, steady acceleration environments (such as moving vehicles, aircraft and projectiles) as well as vibration conditions.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63522-8:2024, when required by the detail specification, is used for testing all kinds of relays. This test can also be used for similar devices when specified in a detail specification.
This document defines a standard test method to ensure that the relay times are within the specified limits.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard applies to particular all-or-nothing electrical relays denominated solid-state relays intended for performing electrical operations by single step function changes to the state of electric circuits between the OFF-state and the ON-state and vice versa.
This document deals with solid-state relays which are intended for incorporation in other products or equipment. As such, solid-state relays are considered to be components and this document defines the basic safety-related and functional requirements for solid-state relays as stand-alone components.
Such solid-state relays are incorporated in products or equipment which themselves have to comply with the relevant product and/or application standard(s) to meet their intended application. The following are examples of such applications:
- general industrial equipment;
- electrical facilities;
- electrical machines;
- electrical appliances;
- office communications;
- building automation and environmental control;
- automation and process control;
- electrical installation engineering;
- medical engineering;
- telecommunications;
- vehicle engineering;
- transportation engineering;
- lighting control.
Where the component is intended to be incorporated into the equipment by the final user without EMC knowledge, an assessment for EMC compliance is available. There are no EMC requirements for solid state relays intended for incorporation into the equipment by the equipment manufacturer, because the performance strongly depends on the application into the equipment.
Solid-state switching devices with monolithic structures fall within the scope of IEC sub195 committee 47E and are not covered in this document.
Semiconductor controllers and contactors fall within the scope of the IEC 60947 series of standards - Low-voltage switchgear and controlgear - developed by IEC subcommittee 121A and are not covered in this document.
Compliance with the requirements of this document is verified by the type tests and routine tests indicated.
The object of this document is to state:
- the characteristics of solid-state relays;
- the requirements which solid-state relays shall comply with reference to
a) their operation and behaviour;
b) their 205 dielectric properties;
- the tests verifying that the requirements have been met, and the test methods to be adopted;
- the information to be given with the solid-state relay or in the manufacturer’s documentation.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
This part of the IEC 61812 series applies to time relays and coupling relays for industrial applications (e.g. control, automation, signal and industrial equipment) and for automatic electrical controls for use in, on, or in association with equipment for residential and similar use.
The term "relay" as used in this document comprises all types of relays with specified time functions and coupling relays, other than measuring relays.
This document defines type test and routine test to confirm the service condition.
- Standard68 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62246-4:2023 gives additional requirements for the evaluation of functional characteristics on reed switching components operated by magnetic actuator and gives guidance for their implementation in selected applications.
This document specifies test and measurement procedures for the application of reed switch (contact) based magnetic sensors.
In case the application of a reed contact magnetic sensor determines additional requirements exceeding those specified in this document, the sensor is evaluated with this application in accordance with the relevant IEC or ISO standard(s) (e.g. IEC 62061 or ISO 13849 series, IEC 60335-1 and relevant parts of the IEC 60335-2 series, IEC 60730-1, IEC 61373, ISO 16750-3).
This document does not apply to:
– sensing or monitoring of the position of elements of interlocking devices for movable guards (see ISO 14119);
– sensing or monitoring of the position of elements of pressure sensitive protective equipment (PSPE, see ISO 13856 series);
– electrical equipment for measurement, control, and laboratory use (see IEC 61010-1);
– aircraft – proximity switches (see ISO 6859-1).
Information contained in this document is relevant to the application of a magnetic sensor on new installations as well as modifications to existing installations.
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60255-1:2022 specifies common rules and requirements applicable to measuring relays and protection equipment, including any combination of equipment to form a distributed protection scheme for power system protection such as control, monitoring and process interface equipment, to obtain uniformity of requirements and tests. This document covers the main technologies in use today; other emerging technologies present specific EMC and safety issues but the philosophy in this document will be applied.
This second edition cancels and replaces the first edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition:
a. scope of document clarified;
b. merging units and communications as an integral part of the protection added;
c. binary output clarification expanded;
d. environmental operating conditions added (Annex B);
e. test reference conditions added;
f. multiple changes to improve understanding across most clauses;
g. derating by manufacturer added;
h. safety and EMC tests removed from document and referenced only;
i. relay setting and type test guidelines modified (Annex A)
j. battery monitor port and low power instrument transformers added.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60255-187-1:2021 specifies the minimum requirements for functional and performance evaluation of (longitudinal) differential protection designed for the detection of faults in ac motors, generators and transformers. This document also defines how to document and publish performance test results. This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document.
This document, together with IEC 60255-187-2 and IEC 60255-187-3, cancels and replaces IEC 60255-13. This document includes the following significant technical changes with respect to IEC 60255-13:
a) IEC 60255-13 has been significantly revised to follow the common structure of the functional standards for protection relays (IEC 60255-1xx series). IEC 60255-187-1 has been developed to address the restrained and unrestrained differential protection of motors, generators and transformers. The revisions include detailed description of the functions including the performance specification, testing and documentation requirements.
- Standard208 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard208 pagesEnglish languagesale 10% offe-Library read for1 day