ISO/TC 276/SC 1/WG 2 - Cell characterization
This document provides standard terminology related to cell counting for biotechnology. This document describes counting of cells in suspension (generally cell concentration) and cells adhered to a substrate (generally area density of cells). This document provides key considerations for general counting methods (including total and differential counting, and direct and indirect counting) as well as for fit for purpose method selection, sources of variability in the measurement process, and data analysis and reporting. This document is applicable to the counting of all cell types – mammalian and non-mammalian (e.g. bacteria, yeast) cells. NOTE Several sector or application-specific international and national standards for cell counting currently exist. When applicable, the user can consult existing standards when operating within their scope (e.g. specific measurement techniques or applications).
- Standard23 pagesEnglish languagesale 15% off
This document specifies general principles, detection strategies and analytical methods for cell line identification of mammalian cells in the field of biotechnology. This document also specifies general requirements and key considerations for method selection, quality control parameters, data analysis and reporting in cell line identification. This document is applicable to routine cell line cross-contamination testing in the fields of basic research, translational medicine studies and cell therapeutic product manufacturing. This document is also applicable to cell line identity confirmation to prevent cell misidentification in academic and industrial laboratories, cell banks and manufacturing sites. This document is primarily applicable to mammalian cells.
- Standard24 pagesEnglish languagesale 15% off
This document specifies the general requirements for cell viability analytical methods and for reporting cell viability. This document gives general guidelines for selecting and establishing fit for purpose cell viability analytical methods. This document specifies requirements for establishing standard operating procedures for cell viability analytical methods. This document also gives guidelines for managing sources of variability for cell viability measurements during pre-analytical, analytical, and post-analytical phases. This document is applicable to cells in suspension, cells adhered to a substrate, and cells in complex matrices. This document is primarily applicable to cell viability measurements of nucleated mammalian cells. NOTE 1 Several sector/application-specific international and national standards for cell viability currently exist. NOTE 2 When applicable, the user can consult existing standards when operating within their scope.
- Standard53 pagesEnglish languagesale 15% off
This document provides an inventory of methods for the detection of microbiological contamination in mammalian cell culture. This document includes considerations for the selection of methods to test the presence of common contaminants such as bacteria, fungi, viruses and mycoplasma. This document is not applicable to prions and protists. This document is intended for use by biomedical researchers, biobank operators and others performing mammalian cell culture.
- Technical report19 pagesEnglish languagesale 15% off
This document provides general requirements for cell morphometry to quantify cell morphological features including cell shape, size and texture. This document addresses aspects of cell image capture using optical microscopy and image processing for morphometry. This document does not address the statistics associated with a morphological analysis of a cellular sample. This document also gives terms and definitions corresponding to cell morphological descriptors, and lists examples and their formulae, that represent quantitative cellular morphological features for evaluation of cell morphology in cell analysis. This document primarily applies to morphological analysis of cultured mammalian cells. This document is not intended for imaging used in clinical diagnostics.
- Standard44 pagesEnglish languagesale 15% off
This document specifies minimum requirements to support accurate measurement of optical signals in photometric methods used for qualitative or quantitative characterization of biological samples. This document is applicable to optical signals that are generated, for example, by bioluminescence, chemiluminescence and fluorescence, and optical signals that are detected as changes of light due to absorption. This document addresses the verification of optical signal measurement instruments used in photometric methods for measurement of biological samples including considerations for the use of optical references. This document does not provide sector- or application-specific performance criteria for the workflow of measuring biological samples. When applicable, users can also consult existing sector- or application- specific standards, or both.
- Standard35 pagesEnglish languagesale 15% off
This document provides guidance, a framework and a risk-based approach for the selection and validation of methods for rapid microbial detection in cellular therapeutic product manufacturing. This document provides a flexible risk-based framework for the detection of microbial contamination in cellular therapeutic products and cellular intermediates. This document provides general requirements and risks associated with cellular therapeutic product manufacturing, with flexibility to address differences in specific manufacturing processes of each unique cellular therapeutic product. This document primarily addresses sterility testing in cellular therapeutic product manufacturing. This document is applicable to other cell-derived therapeutic product manufacturing. This document focuses on rapid microbial test methods (RMTMs) used for both in-process and final product testing. Viral testing in cellular therapeutic product manufacturing is not included in this document.
- Standard44 pagesEnglish languagesale 15% off
This document provides general requirements for the testing of cellular therapeutic products intended for human use. This document also provides considerations for the characterization of cellular therapeutic products, including approaches to select and design analytical methods that are fit for purpose. Such considerations can be used to establish critical quality attributes for a cellular therapeutic product. This document is applicable to cellular starting materials (including those for tissue engineered products) and intermediates of cellular therapeutic products. This document is not applicable to tissues used in transplantation.
- Standard35 pagesEnglish languagesale 15% off
- Standard37 pagesFrench languagesale 15% off
This document provides a method for evaluating aspects of the quality of a cell counting measurement process for a specific cell preparation through a set of quality indicators derived from a dilution series experimental design and statistical analysis. The quality indicators are based on repeatability of the measurement and the degree to which the results conform to an ideal proportional response to dilution. This method is applicable to total, differential, direct and indirect cell counting measurement processes, provided that the measurement process meets the criteria of the experimental design (e.g. cells are suspended in a solution). This method is most suitable during cell counting method development, optimization, validation, evaluation and/or verification of cell counting measurement processes. This method is especially applicable in cases where an appropriate reference material to assess accuracy is not readily available. This method does not directly provide the accuracy of the cell count. This method is primarily applicable to eukaryotic cells. NOTE Several sector/application specific international and national standards for cell counting exist. Where applicable, consulting existing standards when operating within their scope can be helpful.
- Standard53 pagesEnglish languagesale 15% off
- Standard53 pagesEnglish languagesale 15% off
ISO 20391-1:2018 defines terms related to cell counting for biotechnology. It describes counting of cells in suspension (generally cell concentration) and cells adhered to a substrate (generally area density of cells). It provides key considerations for general counting methods (including total and differential counting, and direct and indirect counting) as well as for method selection, measurement process, and data analysis and reporting. ISO 20391-1:2018 is applicable to the counting of all cell types ? mammalian and non-mammalian (e.g. bacteria, yeast) cells. ISO 20391-1:2018 is not intended for counting of cells while in a tissue section or a biomaterial matrix. Several sector/application-specific international and national standards for cell counting currently exist. When applicable, the user can consult existing standards when operating within their scope (specific measurement techniques and/or applications).
- Standard16 pagesEnglish languagesale 15% off
Frequently Asked Questions
ISO/TC 276/SC 1/WG 2 is a Subcommittee within the International Organization for Standardization (ISO). It is named "Cell characterization". This committee has published 10 standards.
ISO/TC 276/SC 1/WG 2 develops ISO standards in the area of Information technology. Currently, there are 10 published standards from this subcommittee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Subcommittee (SC) in ISO operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.