ISO/TC 61/SC 10/WG 10 - Plastic insulation
Isolants en plastique
General Information
This document specifies requirements for factory-made products of sheep wool, which are used for the thermal insulation of buildings. This document applies to material containing more than 50 % (by mass) natural sheep wool, with the balance being polymeric material. The products are delivered as a mat or board with or without facings. This document describes product characteristics and testing methods, marking, labelling and packaging. Products covered in this document are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. The sheep wool mat and board thermal insulation is not to be used when the continuous service temperature of the substrate is outside the range of −60 °C to +80 °C. The use of mothproof agent residues is outside the scope of this document. This document does not address all the health and safety aspects associated with its use. It is the responsibility of the user of this document to establish appropriate health and safety practices.
- Standard17 pagesEnglish languagesale 15% off
ISO 21844:2018 specifies material requirements and identifies the test methods to be used to determine these requirements for cellulose foam for thermal insulation for buildings and other applications. There are four categories of material characterized by the density of the material.
- Standard6 pagesEnglish languagesale 15% off
ISO 4898:2018 specifies requirements and methods of testing for three categories of rigid cellular plastics thermal-insulation products for buildings. It covers rigid cellular plastics in the form of flat or profiled boards, with or without natural skins. They can also be faced or laminated with foil, plastic or metal films or sheets, mineral coatings, paper, cardboard or other materials. ISO 4898:2018 is not applicable to materials used for the thermal insulation of pipes and vessels, for impact sound absorption or for acoustical insulation. ISO 4898:2018 covers the following cellular materials used in the thermal insulation of buildings: - PF based on phenolic polymer; - EPS based on expanded polystyrene; - XPS based on extruded polystyrene; - PUR based on polyurethane. The limiting quality values in this document are for use only in the specification of materials between purchaser and supplier, and are not intended to be used for design purposes. Additional requirements for special applications can be added to those specified in this document by agreement between purchaser and supplier.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard13 pagesEnglish languagesale 15% off
ISO 8873-3:2007 specifies the test procedures that are to be used when testing spray-applied polyurethane foam materials to verify that they meet the requirements given in ISO 8873-1:2006.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard17 pagesEnglish languagesale 15% off
ISO 8873-2:2007 outlines requirements for the application of rigid cellular plastic spray polyurethane foam for thermal insulation. The primary application of the material is for use as thermal insulation. Spray polyurethane foam can also be used as the air barrier material which forms part of an air barrier assembly in buildings. Under specific application conditions, the material can be used in vapour barrier applications in a building assembly (details of the conditions can be obtained from the manufacturer). The application requirements are for the installation of spray polyurethane foam whether applied on a building site or in a prefabrication (manufacturing) facility. ISO 8873-2:2007 can be used for non-building applications when agreed to by the supplier and the purchaser. The requirements include obligations for the manufacturer, the contractor and the installer. The requirements include the selection of chemical components, application requirements, quality control and documentation of the application, limitations for the application and requirements for safety and for disposal of associated waste material and packaging.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard37 pagesEnglish languagesale 15% off
ISO 8873-1:2006 specifies minimum requirements and test methods for spray-applied polyurethane rigid cellular plastic, used as a thermal insulation for both building, whether applied on a building site or in a prefabrication (manufacturing) facility, and non-building applications. The material is also known as in-situ thermal insulation. The spray-applied polyurethane rigid cellular plastic thermal insulation is not to be used when the continuous service temperature of the substrate is outside the range of -60 °C to +80 °C. The test methods used to determine the material properties provide a means of comparing different cellular plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control. They are not intended to predict end-use product performance.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard9 pagesEnglish languagesale 15% off
ISO 9774:2004 gives guidelines to the standards writer in selecting thermal-insulation material properties for standards used in building applications. These guidelines are not intended to prove the suitability of any particular product for any given application. The standard applies only to prefabricated thermal-insulation products, i.e. manufactured mats and boards including any facings or coverings which may be present, although the basic characteristics may also be applied to other insulation products, e.g. in situ in systems or components, where appropriate. The standard covers only thermal-insulation products for use in buildings within normal climatic conditions. It does not cover insulation products for building services, e.g. plumbing and heating, nor insulation products for industrial use. Acoustic properties are not included in the properties given in the standard, although these may be additionally required for some fields of application.
- Standard12 pagesEnglish languagesale 15% off
ISO 4898:2010 specifies requirements and methods of testing for four categories of rigid cellular plastics thermal-insulation products for buildings. It covers rigid cellular plastics in the form of flat or profiled boards, with or without natural skins. They may also be faced or laminated with foil, plastic or metal films or sheets, mineral coatings, paper, cardboard or other materials. It is not applicable to materials used for the thermal insulation of pipes and vessels, for impact sound absorption or for acoustical insulation. It covers the following cellular materials used in the thermal insulation of buildings: PF based on phenolic polymer; EPS based on expanded polystyrene; XPS based on extruded polystyrene; PUR based on polyurethane.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard14 pagesEnglish languagesale 15% off
- Standard12 pagesRussian languagesale 15% off
ISO 4898:2008 specifies requirements and methods of testing for four categories of rigid cellular plastics thermal-insulation products for buildings. It covers rigid cellular plastics in the form of flat or profiled boards, with or without natural skins. They may also be faced or laminated with foil, plastic or metal films or sheets, mineral coatings, paper, cardboard or other materials. It is not applicable to materials used for the thermal insulation of pipes and vessels, for impact sound absorption or for acoustical insulation. It covers the following cellular materials used in the thermal insulation of buildings: — PF based on phenolic polymer; — EPS based on expanded polystyrene; — XPS based on extruded polystyrene; — PUR based on polyurethane.
- Standard14 pagesEnglish languagesale 15% off
- Draft19 pagesEnglish languagesale 15% off
ISO 4898:2006 specifies requirements and methods of testing for four categories of rigid cellular plastics thermal-insulation products for buildings. It covers rigid cellular plastics in the form of flat or profiled boards, with or without natural skins. They may also be faced or laminated with foil, plastic or metal films or sheets, mineral coatings, paper, cardboard or other materials. It is not applicable to materials used for the thermal insulation of pipes and vessels, for impact sound absorption or for acoustical insulation. It covers the following cellular materials used in the thermal insulation of buildings: PF based on phenolic polymer; EPS based on expanded polystyrene; XPS based on extruded polystyrene; PUR based on polyurethane.
- Standard14 pagesEnglish languagesale 15% off
ISO 4898:2004 specifies requirements and methods of testing for three categories of rigid cellular plastics thermal-insulation products for buildings. It covers rigid cellular plastics in the form of flat or profiled boards, with or without natural skins. They may also be faced or laminated with foil, plastic or metal films or sheets, mineral coatings, paper, cardboard or other materials. This International Standard is not applicable to materials used for the thermal insulation of pipes and vessels, for impact sound absorption or for acoustical insulation. This International Standard covers the following cellular materials used in the thermal insulation of buildings: RC/PS based on polystyrene; RC/PUR based on polyurethanes made with isocyanates; RC/PF based on phenolic polymer.
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
- Technical report4 pagesEnglish languagesale 15% off
- Technical report4 pagesFrench languagesale 15% off
- Technical report4 pagesFrench languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageFrench languagesale 15% off
Specifies the rquirements and test methods for spray- applied rigid polyurethane cellular plastics used as thermal insulation in two loadbearing categories. The foam may be either produce on site or in a manufactoring facility. The test samples shall be representative of the in place finshed material and of sufficient quantity and size to allow the tests specified to be carried out. The property requirements of RC/PUR- SA for thermal insulation of buildings are listed in a table.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard6 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard7 pagesFrench languagesale 15% off