SIST EN ISO 1452-2:2010
(Main)Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)
ISO 1452-2:2009 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.
In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC‑U pipes without a socket and pipes with a socket (integral or not), intended to be used for the following:
- water mains and services buried in the ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above ground drainage and sewerage under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to pipes for the conveyance of water and waste water up to and including 45 °C and to a range of pipe sizes and pressure classes. It gives requirements concerning colours.
Kunststoff-Rohrleitungssysteme für die Wasserversorgung und für erdverlegte und nicht erdverlegte Entwässerungs- und Abwasserdruckleitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 2: Rohre (ISO 1452-2:2009)
Dieser Teil von ISO 1452 legt die Eigenschaften von vollwandigen Rohren aus weichmacherfreiem Poly-(vinylchlorid) (PVC U) für Rohrleitungssysteme fest, die für die Wasserversorgung und für erdverlegte und nicht erdverlegte Entwässerungs und Abwasserdruckleitungen eingesetzt werden.
Er legt außerdem die Prüfparameter für die Prüfverfahren fest, auf die in diesem Teil von ISO 1452 verwiesen wird.
Zusammen mit ISO 1452 1 und ISO 1452 5 gilt dieser Teil für extrudierte PVC U Rohre ohne Muffe und mit Muffe (angeformt oder nicht), die für folgende Anwendungsgebiete vorgesehen sind:
a) erdverlegte Versorgungs und Hausanschlussleitungen;
b) oberirdischer Transport von Wasser sowohl innerhalb als auch außerhalb von Gebäuden;
c) erdverlegte und nicht erdverlegte Entwässerungs und Abwasserdruckleitungen.
Dieser Teil von ISO 1452 ist anwendbar auf Rohrleitungssysteme, die für die Wasserver¬sorgung unter Druck bis einschließlich 25 °C (Kaltwasser) für den menschlichen Gebrauch (Trinkwasser) und für allgemeine Zwecke (Betriebswasser) sowie für Abwasser unter Druck vorgesehen sind.
Dieser Teil von ISO 1452 enthält Festlegungen für Rohre zum Transport von Wasser und Abwasser bis einschließlich 45 °C. Für Temperaturen zwischen 25 °C und 45 °C gilt Bild A.1.
ANMERKUNG 1 Hersteller und Anwender können die Anwendung bei Temperaturen oberhalb 45 °C von Fall zu Fall vereinbaren.
Dieser Teil von ISO 1452 enthält Festlegungen für Rohrgrößen und Druckklassen und legt Anforderungen an die Einfärbung fest.
ANMERKUNG 2 Der Anwender oder Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der geltenden nationalen Festlegungen und Verlegeverfahren oder Codes für die entsprechende Auswahl dieser Kriterien verantwortlich.
Systèmes de canalisations en plastique pour l'adduction d'eau, pour le drainage enterré et en surface, et pour le réseau d'égout sous pression - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 2: Tubes (avec ou sans emboîtures incorporées) (ISO 1452-2:2009)
L'ISO 1452-2:2009 spécifie les caractéristiques des tubes à paroi compacte en poly(chlorure de vinyle) non plastifié (PVC‑U) pour les systèmes de canalisations destinés à l'alimentation en eau et pour les collecteurs d'assainissement enterrés et aériens avec pression. Elle spécifie également les paramètres d'essai pour les méthodes d'essai auxquelles il y est fait référence.
Conjointement à l'ISO 1452-1 et à l'ISO 1452-5, elle s'applique aux tubes extrudés en PVC‑U sans emboîture et aux tubes avec emboîture (intégrée ou non), destinés aux usages suivants:
— conduites principales et branchements enterrés;
— transport de l'eau en aérien, à l'extérieur et à l'intérieur des bâtiments;
— collecteurs d'assainissement enterrés et aériens avec pression.
L'ISO 1452-2:2009 s'applique aux systèmes de canalisations destinés à l'alimentation en eau sous pression jusqu'à 25 °C (eau froide) compris, destinée à la consommation humaine et pour les besoins généraux aussi bien que les eaux usées sous pression. Elle s'applique également aux tubes pour le transport de l'eau jusqu'à 45 °C inclus et concerne une série de dimensions de tubes et de classes de pression. Elle donne des exigences pour les couleurs.
Cevni sistemi iz polimernih materialov za oskrbo z vodo in za podzemno in nadzemno odvodnjavanje in kanalizacijo pod tlakom - Nemehčan polivinilklorid (PVC-U) - 2. del: Cevi (ISO 1452-2:2009)
Ta del ISO 1452 določa značilnosti cevi za trdne stene, narejenih iz nemehčanega polivinilklorida (PVC-U), ki so namenjene cevnim sistemom za oskrbo z vodo ter podzemno in nadzemno odvodnjavanje in kanalizacijo pod tlakom. Določa tudi preskusne parametre za preskusne metode, navedene v tem delu ISO 1452. V povezavi z ISO 1452-1 in ISO 1452-5 velja za cevi iz ekstrudiranega polivinilklorida brez spojev in cevi s spojem (vgrajenim ali ne), ki se uporabljajo za naslednje namene: a) za podzemne glavne vodovode in dovode; b) nadzemni prenos vode zunaj in znotraj stavb; c) podzemno in nadzemno odvodnjavanje in kanalizacijo pod tlakom. Velja za cevne sisteme, ki se uporabljajo za oskrbo z vodo pod tlakom do vključno 25°C (s hladno vodo), namenjeno za prehrano ljudi in za splošne namene, ter za odpadne vode pod tlakom. Ta del ISO 1452 določa cevi za prenos vode in odpadne vode do vključno 45°C. Za temperature med 25°C in 45°C velja Slika A.1. Ta del ISO 1452 določa razpon velikosti cevi in tlačne razrede ter podaja zahteve v zvezi z barvami.
General Information
Relations
Overview
EN ISO 1452-2:2009 / ISO 1452-2:2009 specifies requirements for solid‑wall pipes manufactured from unplasticized poly(vinyl chloride) (PVC‑U) used in piping systems for water supply and for buried and above‑ground drainage and sewerage under pressure. Prepared by CEN in collaboration with ISO, this part (Part 2: Pipes) covers extruded PVC‑U pipes with or without sockets (integral or separate) and sets test parameters for the referenced test methods.
Key topics and requirements
- Scope and application: Pipes for water mains, service lines buried in the ground, above‑ground conveyance (inside and outside buildings), and buried or above‑ground drainage and sewerage under pressure. Applicable for cold water up to and including 25 °C (potable and general use) and for conveyance up to 45 °C (with guidance for higher temperatures handled case‑by‑case).
- Material and material properties: Requirements for PVC‑U pipe material, including density and MRS (minimum required strength) parameters.
- Geometrical characteristics: Nominal and mean outside diameters, wall thicknesses and tolerances, pipe lengths, and socket geometries.
- Mechanical and physical tests: Impact strength, resistance to internal pressure (reference to ISO 1167‑1), and other physical performance checks. Test parameter values and methods are specified.
- Joints and end preparations: Requirements for pipe ends suitable for ring‑seal or solvent‑cement joints and for pipes with sockets (integral or not).
- Classification and selection: Guidance on pressure classes and pipe series selection for different temperature ranges and service conditions.
- Marking, colours and traceability: Minimum marking requirements, colour guidance and identification for intended use.
- Annexes: Normative annexes include allowable operating pressures and imperial (inch) sizes.
Practical applications and users
EN ISO 1452‑2 is used by:
- Manufacturers of PVC‑U pipes to design, test and mark products to comply with European/ISO requirements.
- Specifiers and engineers selecting pipe sizes, pressure classes and joint types for potable water, irrigation, plumbing and sewerage under pressure.
- Water utilities, contractors and installers executing buried mains, service connections, and above‑ground installations.
- Test laboratories and conformity bodies performing mechanical and pressure tests and verifying compliance.
- Procurement and regulators referencing a harmonized standard for safety, fitness for purpose and interoperability.
Keywords: EN ISO 1452-2:2009, ISO 1452-2:2009, PVC-U pipes, plastics piping systems, water supply, drainage and sewerage under pressure, PVC‑U piping standard.
Related standards
- ISO 1452‑1 (General)
- ISO 1452‑3 (Fittings)
- ISO 1452‑4 (Valves)
- ISO 1452‑5 (Fitness for purpose / joints)
- ISO/TR 4191 (Installation guidance) and ENV/ISO guidance for conformity assessment (part 7)
Frequently Asked Questions
SIST EN ISO 1452-2:2010 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009)". This standard covers: ISO 1452-2:2009 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to. In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC‑U pipes without a socket and pipes with a socket (integral or not), intended to be used for the following: - water mains and services buried in the ground; - conveyance of water above ground for both outside and inside buildings; - buried and above ground drainage and sewerage under pressure. It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to pipes for the conveyance of water and waste water up to and including 45 °C and to a range of pipe sizes and pressure classes. It gives requirements concerning colours.
ISO 1452-2:2009 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to. In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC‑U pipes without a socket and pipes with a socket (integral or not), intended to be used for the following: - water mains and services buried in the ground; - conveyance of water above ground for both outside and inside buildings; - buried and above ground drainage and sewerage under pressure. It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to pipes for the conveyance of water and waste water up to and including 45 °C and to a range of pipe sizes and pressure classes. It gives requirements concerning colours.
SIST EN ISO 1452-2:2010 is classified under the following ICS (International Classification for Standards) categories: 23.040.05 - Pipeline and its parts for external sewage systems; 91.140.60 - Water supply systems; 93.030 - External sewage systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 1452-2:2010 has the following relationships with other standards: It is inter standard links to SIST ISO 4422-2:1997, SIST ISO 2045:1995, SIST EN 1456-1:2002, SIST EN 1452-2:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST EN ISO 1452-2:2010 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2010
1DGRPHãþD
SIST EN 1452-2:2000
SIST EN 1456-1:2002
&HYQLVLVWHPLL]SROLPHUQLKPDWHULDORY]DRVNUER]YRGRLQ]DSRG]HPQRLQ
QDG]HPQRRGYRGQMDYDQMHLQNDQDOL]DFLMRSRGWODNRP1HPHKþDQSROLYLQLONORULG
39&8GHO&HYL,62
Plastics piping systems for water supply and for buried and above-ground drainage and
sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes
(ISO 1452-2:2009)
Kunststoff-Rohrleitungssysteme für die Wasserversorgung und für erdverlegte und nicht
erdverlegte Entwässerungs- und Abwasserdruckleitungen - Weichmacherfreies
Polyvinylchlorid (PVC-U) - Teil 2: Rohre (ISO 1452-2:2009)
Systèmes de canalisations en plastique pour l'adduction d'eau, pour le drainage enterré
et en surface, et pour le réseau d'égout sous pression - Poly(chlorure de vinyle) non
plastifié (PVC-U) - Partie 2: Tubes (avec ou sans emboîtures incorporées) (ISO 1452-
2:2009)
Ta slovenski standard je istoveten z: EN ISO 1452-2:2009
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
91.140.60 Sistemi za oskrbo z vodo Water supply systems
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 1452-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2009
ICS 91.140.60; 93.025; 23.040.20; 23.040.45 Supersedes EN 1452-2:1999, EN 1456-1:2001
English Version
Plastics piping systems for water supply and for buried and
above-ground drainage and sewerage under pressure -
Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO
1452-2:2009)
Systèmes de canalisations en plastique pour l'alimentation Kunststoff-Rohrleitungssysteme für die Wasserversorgung
en eau, pour branchements et collecteurs d'assainissement und für erdverlegte und nicht erdverlegte Entwässerungs-
enterrés et aériens avec pression - Poly(chlorure de vinyle) und Abwasserdruckleitungen - Weichmacherfreies
non plastifié (PVC-U) - Partie 2: Tubes (ISO 1452-2:2009) Polyvinylchlorid (PVC-U) - Teil 2: Rohre (ISO 1452-2:2009)
This European Standard was approved by CEN on 4 November 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 1452-2:2009: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
This document (EN ISO 1452-2:2009) has been prepared by Technical Committee CEN/TC 155 “Plastics
piping systems and ducting systems", the secretariat of which is held by NEN, in collaboration with Technical
Committee ISO/TC 138 "Plastics pipes, fittings and valves for the transport of fluids".
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by June 2010, and conflicting national standards shall be withdrawn at
the latest by June 2010.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 1452-2:1999, EN 1456-1:2001.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
INTERNATIONAL ISO
STANDARD 1452-2
First edition
2009-12-01
Plastics piping systems for water supply
and for buried and above-ground
drainage and sewerage under pressure —
Unplasticized poly(vinyl chloride)
(PVC-U) —
Part 2:
Pipes
Systèmes de canalisations en plastique pour l'alimentation en eau, pour
branchements et collecteurs d'assainissement enterrés et aériens avec
pression — Poly(chlorure de vinyle) non plastifié (PVC-U) —
Partie 2: Tubes
Reference number
ISO 1452-2:2009(E)
©
ISO 2009
ISO 1452-2:2009(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2009
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2009 – All rights reserved
ISO 1452-2:2009(E)
Contents Page
Foreword .iv
Introduction.v
1 Scope.1
2 Normative references.1
3 Terms, definitions, symbols and abbreviated terms .2
4 Material .3
4.1 Pipe material .3
4.2 Density.3
4.3 MRS-value .3
5 General characteristics.3
5.1 Appearance .3
5.2 Colour .3
5.3 Opacity of pipes intended for the above-ground conveyance of water .3
6 Geometrical characteristics .3
6.1 Measurement of dimensions.3
6.2 Nominal outside diameters.3
6.3 Mean outside diameters and their tolerances .4
6.4 Wall thickness and their tolerances .5
6.5 Length of pipe.6
6.6 Pipes with sockets .7
6.7 Pipe ends for ring seal or solvent cement joints .11
7 Classification and selection of pipes .11
7.1 Classification .11
7.2 Selection of nominal pressure and pipe series S for water up to and including 25 °C .11
7.3 Determination of the allowable operating pressure for water up to 45 °C .11
8 Mechanical characteristics.11
8.1 Impact strength.11
8.2 Resistance to internal pressure.12
9 Physical characteristics.13
10 Sealing rings .14
11 Adhesives.14
12 Performance requirements.14
13 Marking.14
13.1 General .14
13.2 Minimum required marking .14
13.3 Additional marking .15
Annex A (normative) Allowable operating pressures .16
Annex B (normative) Imperial (inch)-sized pipes .18
Bibliography.23
ISO 1452-2:2009(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 1452-2 was prepared by the European Committee for Standardization (CEN) Technical Committee
CEN/TC 155, Plastics piping systems and ducting systems, in collaboration with ISO Technical Committee
ISO/TC 138, Plastics pipes, fittings and valves for the transport of fluids, Subcommittee SC 2, Plastics pipes
and fittings for water supplies, in accordance with the Agreement on technical cooperation between ISO and
CEN (Vienna Agreement).
This first edition cancels and replaces ISO 4422-2:1996 and ISO 2045, which have been technically revised.
ISO 1452 consists of the following parts, under the general title Plastics piping systems for water supply and
for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride)
(PVC-U):
⎯ Part 1: General
⎯ Part 2: Pipes
⎯ Part 3: Fittings
⎯ Part 4: Valves
⎯ Part 5: Fitness for purpose of the system
Guidance for the assessment of conformity is to form the subject of a part 7.
iv © ISO 2009 – All rights reserved
ISO 1452-2:2009(E)
Introduction
The System Standard, of which this is Part 2, specifies the requirements for a piping system and its
components made from unplasticized poly(vinyl chloride) (PVC-U). The piping system is intended to be used
for water supply and for buried and above-ground drainage and sewerage under pressure.
In respect of potential adverse effects on the quality of water intended for human consumption, caused by the
products covered by this part of ISO 1452, the following are relevant.
a) This part of ISO 1452 provides no information as to whether or not the products can be used without
restriction.
b) Existing national regulations concerning the use and/or the characteristics of these products remain in
force.
Requirements and test methods for material and components, other than pipes, are specified in ISO 1452-1,
ISO 1452-3 and ISO 1452-4. Characteristics for fitness for purpose (mainly for joints) are established in
ISO 1452-5.
This part of ISO 1452 specifies the characteristics of pipes.
[1]
Guidance for installation is given in ISO/TR 4191 .
[2]
Guidance for assessment of conformity is provided in ENV 1452-7 .
INTERNATIONAL STANDARD ISO 1452-2:2009(E)
Plastics piping systems for water supply and for buried and
above-ground drainage and sewerage under pressure —
Unplasticized poly(vinyl chloride) (PVC-U) —
Part 2:
Pipes
1 Scope
This part of ISO 1452 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl
chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and
sewerage under pressure.
It also specifies the test parameters for the test methods referred to in this part of ISO 1452.
In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC-U pipes without a socket and
pipes with a socket (integral or not), intended to be used for the following:
a) water mains and services buried in the ground;
b) conveyance of water above ground for both outside and inside buildings;
c) buried and above-ground drainage and sewerage under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C
(cold water) intended for human consumption and for general purposes as well as for waste water under
pressure.
This part of ISO 1452 specifies pipes for the conveyance of water and waste water up to and including 45 °C.
For temperatures between 25 °C and 45 °C, Figure A.1 applies.
NOTE 1 The producer and the end-user can come to agreement on the possibilities of use for temperatures above
45 °C on a case-by-case basis.
This part of ISO 1452 specifies a range of pipe sizes and pressure classes, and gives requirements
concerning colours.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects,
taking into account their particular requirements and any relevant national regulations and installation practices or codes.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of
the resistance to internal pressure — Part 1: General method
ISO 1452-2:2009(E)
ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of
the resistance to internal pressure — Part 2: Preparation of pipe test pieces
ISO 1183-1:2004, Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion
method, liquid pyknometer method and titration method
ISO 1452-1:2009, Plastics piping systems for water supply and for buried and above-ground drainage and
sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC U) — Part 1: General
ISO 1452-5, Plastics piping systems for water supply and for buried and above-ground drainage and
sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC U) — Part 5: Fitness for purpose of the
system
ISO 2505, Thermoplastics pipes — Longitudinal reversion — Test method and parameters
ISO 2507-1:1995, Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test
method
ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
ISO 6259-1, Thermoplastics pipes — Determination of tensile properties — Part 1: General test method
ISO 6259-2, Thermoplastics pipes — Determination of tensile properties — Part 2: Pipes made of
unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) and high-impact poly(vinyl
chloride) (PVC-HI)
ISO 7387-1, Adhesives with solvents for assembly of PVC-U pipe elements — Characterization — Part 1:
Basic test methods
ISO 7686, Plastics pipes and fittings — Determination of opacity
ISO 9311-1, Adhesives for thermoplastic piping systems — Part 1: Determination of film properties
ISO 9852, Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified
temperature (DCMT) — Test method
ISO 18373-1, Rigid PVC pipes — Differential scanning calorimetry (DSC) method — Part 1: Measurement of
the processing temperature
EN 681-1:1996, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage
applications — Part 1: Vulcanized rubber
EN 744:1995, Plastics piping and ducting systems — Thermoplastics pipes — Test method for resistance to
external blows by the round-the-clock method
3 Terms, definitions, symbols and abbreviated terms
For the purposes of this document, the terms, definitions, symbols and abbreviated terms given in ISO 1452-1
and the following apply:
L length of socket
m depth of engagement
2 © ISO 2009 – All rights reserved
ISO 1452-2:2009(E)
4 Material
4.1 Pipe material
The material to be used shall conform to ISO 1452-1 and to the requirements given in 4.2 and 4.3.
4.2 Density
The density, ρ, at 23 °C of the pipe, when measured in accordance with ISO 1183-1, shall be within the
following limits:
3 3
1 350 kg/m u ρ u 1 460 kg/m
4.3 MRS-value
The pipe material shall have a minimum required strength, MRS, as defined in ISO 1452-1:2009, 4.4.1, of at
least 25 MPa.
The manufacturer of the compound or formulation shall confirm the MRS by testing as described in
ISO 1452-1:2009, 4.4.1 or 4.4.2, respectively.
5 General characteristics
5.1 Appearance
When viewed without magnification the internal and external surfaces of pipes shall be smooth, clean and free
from scoring, cavities and other surface defects to an extent that would prevent conformity to this part of
ISO 1452. The material shall not contain any impurities visible without magnification. The ends of the pipe
shall be cut cleanly and square to the axis of the pipe.
5.2 Colour
The colour of the pipes shall be either grey, blue or cream for water supply, and grey or brown for drainage
and sewerage under pressure. The colour of the pipes shall be uniform throughout the wall.
NOTE Attention is drawn to the fact that the colouring of pipes for the supply of water for human consumption can be
part of national regulation.
5.3 Opacity of pipes intended for the above-ground conveyance of water
The wall of the pipe shall be opaque and shall not transmit more than 0,2 % of visible light when measured in
accordance with ISO 7686.
6 Geometrical characteristics
6.1 Measurement of dimensions
Dimensions shall be measured in accordance with ISO 3126.
6.2 Nominal outside diameters
The nominal outside diameter, d , of a pipe shall conform to Table 1.
n
ISO 1452-2:2009(E)
6.3 Mean outside diameters and their tolerances
The mean outside diameter, d , of a pipe shall conform to the applicable nominal outside diameter, d , within
em n
the tolerance given in Table 1.
The tolerance for out-of-roundness shall conform to Table 1.
Table 1 — Nominal outside diameters and tolerances
Dimensions in millimetres
b
Nominal outside Tolerance for mean Tolerance for out-of-roundness
a
diameter outside diameter, d
em
c d
d x S 20 to S 16 S 12,5 to S 5
n
12 0,2 — 0,5
16 0,2 — 0,5
20 0,2 — 0,5
25 0,2 — 0,5
32 0,2 — 0,5
40 0,2 1,4 0,5
50 0,2 1,4 0,6
63 0,3 1,5 0,8
75 0,3 1,6 0,9
90 0,3 1,8 1,1
110 0,4 2,2 1,4
125 0,4 2,5 1,5
140 0,5 2,8 1,7
160 0,5 3,2 2,0
180 0,6 3,6 2,2
200 0,6 4,0 2,4
225 0,7 4,5 2,7
250 0,8 5,0 3,0
280 0,9 6,8 3,4
315 1,0 7,6 3,8
355 1,1 8,6 4,3
400 1,2 9,6 4,8
450 1,4 10,8 5,4
500 1,5 12,0 6,0
560 1,7 13,5 6,8
630 1,9 15,2 7,6
710 2,0 17,1 8,6
800 2,0 19,2 9,6
900 2,0 21,6 —
1 000 2,0 24,0 —
a [3]
The tolerance conforms to grade D of ISO 11922-1 for d u 50 and to grade C for d > 50. The tolerance
n n
+ x
is expressed in the form mm, where x is the value of the tolerance.
b
The tolerance is expressed as the difference between the largest and the smallest outside diameter in a
cross-section of the pipe (i.e. d − d ).
e, max e, min
c [3]
For d u 250, the tolerance conforms to grade N of ISO 11922-1 .
n
[3]
For d > 250, the tolerance conforms to grade M of ISO 11922-1 . The requirement for out-of-roundness is only
n
applicable prior to storage.
d [3]
For a d of 12 to 1 000, the tolerance conforms to 0,5 grade M of ISO 11922-1 . The requirement for out-
n
of-roundness is only applicable prior to the pipe leaving the manufacturer's premises.
4 © ISO 2009 – All rights reserved
ISO 1452-2:2009(E)
6.4 Wall thickness and their tolerances
The nominal wall thickness, e , is classified with the pipe series S. The nominal wall thickness corresponds to
n
the minimum allowable wall thickness.
The nominal wall thickness shall conform to Table 2, as appropriate to the pipe series.
The tolerance for wall thickness, e, shall conform to Table 3.
Table 2 — Nominal (minimum) wall thicknesses
Pipe series S
Nominal (minimum) wall thickness
Nominal
outside
S 20 S 16 S 12,5 S 10 S 8 S 6,3 S 5
diameter,
(SDR 41) (SDR 33) (SDR 26) (SDR 21) (SDR 17) (SDR 13,6) (SDR 11)
d
n
Nominal pressure PN based on design coefficient C = 2,5
PN 6 PN 8 PN 10 PN 12,5 PN 16 PN 20
12 — — — — — 1,5
16 — — — — — 1,5
20 — — — — 1,5 1,9
25 — — — 1,5 1,9 2,3
32 — 1,5 1,6 1,9 2,4 2,9
40 1,5 1,6 1,9 2,4 3,0 3,7
50 1,6 2,0 2,4 3,0 3,7 4,6
63 2,0 2,5 3,0 3,8 4,7 5,8
75 2,3 2,9 3,6 4,5 5,6 6,8
90 2,8 3,5 4,3 5,4 6,7 8,2
a
Nominal pressure PN based on design coefficient C = 2,0
PN 6 PN 8 PN 10 PN 12,5 PN 16 P
...
The SIST EN ISO 1452-2:2010 standard is a comprehensive guideline that outlines the characteristics and requirements for solid-wall pipes constructed from unplasticized poly(vinyl chloride) (PVC-U). This standard is particularly relevant due to its focus on piping systems designed for crucial applications such as water supply and drainage in both buried and above-ground scenarios. One of the key strengths of this standard is its clear specification of test parameters and methods, ensuring the reliability of the solid-wall pipes in various conditions. This rigor in testing is essential for maintaining safety and performance, especially in systems that carry water for human consumption and other general purposes. Furthermore, the standard effectively delineates the various applications, covering not only water mains and services buried in the ground but also the conveyance of water above ground across different environments. SIST EN ISO 1452-2:2010 also addresses the thermal capacities of these pipes, specifying their suitability for use with water and wastewater at temperatures up to 45 °C. This is significant for ensuring that the pipes perform adequately under varying workload and temperature conditions, enhancing their versatility in various settings. Another notable aspect of this standard is its coverage of pipe sizes and pressure classes, which adds to the flexibility of usage across different projects. The inclusion of requirements concerning colors further emphasizes the standard's comprehensiveness, catering to aesthetic considerations that may be critical in certain installations. In conjunction with ISO 1452-1 and ISO 1452-5, SIST EN ISO 1452-2:2010 forms a complete framework for the production and application of PVC-U pipes, ensuring that users have a reliable reference for managing systems that are vital for infrastructure related to water supply and wastewater management. Overall, its meticulous attention to testing, applicability, and user requirements makes it a pivotal standard in the field of piping systems.
SIST EN ISO 1452-2:2010 표준은 비가소화 폴리염화비닐(PVC-U)로 제작된 고체 벽 파이프의 특성을 규정하여, 물 공급 및 매립 및 지상 배수 및 하수 시스템에 적용되는 시스템을 다룹니다. 이 표준은 특히 물의 소비 및 일반적인 용도로 사용되는 압력 하의 물 공급을 위한 설정을 명확히 하고 있으며, 폐수를 포함한 여러 사용 목적의 파이프에 대해 언급하고 있습니다. 이 표준의 주요 강점 중 하나는 압력 하의 물 공급에 대한 명확한 지침을 제공한다는 점입니다. 이는 특히 인간 소비를 위한 용도로 사용되는 냉수와 폐수를 수용할 수 있는 기준을 정립하고 있어, 사용자가 기대할 수 있는 안전성과 효율성을 강화합니다. 또한, 이 표준은 25 °C까지의 온도와 45 °C까지의 폐수에 대한 파이프의 요구 사항을 구체적으로 명시하고 있어 다양한 온도 및 압력 조건하에서의 적용 가능성을 보여줍니다. SIST EN ISO 1452-2:2010은 ISO 1452-1 및 ISO 1452-5와 함께 운영되어, 소켓이 있는 파이프와 없는 파이프 모두를 포괄하는 범위를 설정하고 있습니다. 이는 다양한 형태의 파이프가 물 공급 및 배수 시스템에 효과적으로 적용될 수 있도록 합니다. 또한 색상에 대한 요구 사항을 제시하여, 사용자에게 필요한 추가적인 기준을 제공합니다. 결론적으로, SIST EN ISO 1452-2:2010 표준은 물 공급 및 배수 시스템의 효과적이고 안전한 제작 및 사용을 위한 신뢰할 수 있는 지침을 제공하여, PVC-U 파이프의 적용 범위를 넓히고 관련 산업에 큰 기여를 하고 있습니다.
Die Norm SIST EN ISO 1452-2:2010 legt die Eigenschaften von Rohren aus unplasticisiertem Polyvinylchlorid (PVC-U) für Rohrleitungssysteme fest, die für die Wasserversorgung sowie für die unterirdische und oberirdische Entwässerung und Abwasserentsorgung unter Druck vorgesehen sind. Der Anwendungsbereich dieser Norm ist klar definiert und umfasst sowohl die Verlegung von Wasserleitungen im Erdreich als auch die Führung von Wasser über dem Boden, sowohl außerhalb als auch innerhalb von Gebäuden. Einer der größten Stärken dieser Norm ist der Fokus auf die spezifischen Anforderungen von PVC-U-Rohren, die in Druckanwendungen eingesetzt werden. Insbesondere deckt die Norm Rohre ab, die für die Wasserverteilung unter Druck bis 25 °C, einschließlich Trinkwasseranwendungen, sowohl für allgemeine Zwecke als auch für Abwasser unter Druck geeignet sind. Darüber hinaus wird die Anwendung für Rohre, die Wasser und Abwasser bei Temperaturen bis zu 45 °C transportieren, klar umrissen, was die Vielseitigkeit und Anwendbarkeit der Norm steigert. Ein weiterer wichtiger Aspekt ist, dass die Norm gemeinsam mit den Normen ISO 1452-1 und ISO 1452-5, die die Anforderungen und Prüfmethoden für PVC-U-Rohre spezifizieren, Anwendung findet. Dies gewährleistet eine umfassende Standardisierung für extrudierte PVC-U-Rohre, sowohl ohne Muffe als auch mit Muffe, und fördert die Konsistenz und Qualität in der Produktion und Anwendung solcher Rohre. Die Norm beinhaltet auch Anforderungen an die Farbausführung der Rohre, was zusätzliche Relevanz in der Praxis schafft, da dies die Identifikation und Handhabung der Materialien erleichtert. Dank der klaren Vorgaben hinsichtlich der Prüfparameter und der Testmethoden wird Sicherheit und Zuverlässigkeit gewährleistet, was nicht nur für Hersteller, sondern auch für Endverbraucher von entscheidender Bedeutung ist. Zusammenfassend lässt sich sagen, dass die SIST EN ISO 1452-2:2010 eine essentielle Norm darstellt, die umfassende Anforderungen für PVC-U-Rohre definiert und somit einen wichtigen Beitrag zur Qualität und Sicherheit in den Bereichen Wasserver- und -entsorgung sowie Abwasserentsorgung leistet.
SIST EN ISO 1452-2:2010は、水供給および圧力下での埋設および地上排水システムに用いるための非可塑化ポリ塩化ビニル(PVC-U)製のパイプに関する標準である。この標準は、PVC-Uから製造された固体壁パイプの特性を規定しており、特に水道本管やサービスライン、建物内外での流水、圧力排水および下水の輸送に向けた用途に焦点を当てている。 この標準は、ISO 1452-1およびISO 1452-5と連携して、ソケットなしおよびソケット付き(統合型または非統合型)の押出PVC-Uパイプに適用される。特に、供給される水が人間の消費に適したものであり、一般的な目的にも使用できるよう水圧が最大25℃まで対応している点が特徴である。また、最大45℃までの水および廃水の輸送にも適していることから、多様なニーズに応えることができる。 SIST EN ISO 1452-2:2010の強みは、明確な試験パラメータを規定している点である。これにより、パイプの品質管理が容易になり、実際の運用環境においても信頼性の高い性能を発揮することが保証される。さらに、パイプの色についての要件も示されており、設計や施工に関する柔軟性を提供している。 この標準は、圧力下での水供給と排水システムにおけるPVC-Uパイプの重要性を反映しており、適用範囲の広さからさまざまな産業において非常に関連性が高い。水供給や排水管理の分野において、標準に則った施工を行うことで、設備の寿命を延ばし、安全で効率的なシステムの実現が促進される。
La norme SIST EN ISO 1452-2:2010 définit les caractéristiques des tuyaux à paroi pleine en polychlorure de vinyle non plastifié (PVC-U) pour des systèmes de tuyauterie destinés à l'approvisionnement en eau ainsi qu'à l'évacuation et à l'assainissement sous pression, tant enterrés que hors-sol. Cette norme est d'une grande pertinence dans le secteur de la plomberie et de l'assainissement, en particulier pour les infrastructures hydrauliques. Les forces de la norme résident dans son approche exhaustive des tuyaux en PVC-U, qui inclut des spécifications claires pour les tuyaux sans socket ainsi que ceux avec un socket, qu'il soit intégré ou non. En intégrant des exigences sur la couleur des tuyaux, elle assure une grande conformité avec les exigences esthétiques et fonctionnelles du marché. En outre, la norme établit des paramètres de test précis, garantissant que les méthodes utilisées pour évaluer les tuyaux respectent des critères rigoureux de performance et de durabilité. La norme est également pertinente car elle couvre une large gamme d'applications, y compris la distribution d'eau pour la consommation humaine et les usages généraux, ainsi que l'évacuation des eaux usées sous pression. Les tuyaux sont conçus pour des températures allant jusqu'à 25 °C pour l'eau froide et jusqu'à 45 °C pour les applications d'eaux usées, ce qui en fait une solution flexible et efficace pour divers environnements. La norme définit également plusieurs classes de pression et tailles de tuyaux, ce qui permet une adaptation à différents projets et besoins d'installation. Par conséquent, la norme SIST EN ISO 1452-2:2010 joue un rôle crucial dans la normalisation des systèmes de tuyauterie en PVC-U, garantissant non seulement la qualité et la sécurité des installations, mais aussi la durabilité des réseaux d'approvisionnement et d'évacuation dans divers contextes d’utilisation.