Radio-frequency connectors. Part 15: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 4,13 mm (0,163 in) with threaded coupling - Characteristic impedance 50 Ω (Type SMA) (IEC 61169-15:2021)

This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with inner diameter
of outer conductor 4,13 mm (0,163 in) with threaded coupling with a characteristic impedance
of 50 Ω (type SMA).
This document specifies mating face dimensions for high performance connectors – grade 1,
dimensional details of standard test connectors – grade 0, gauging information and tests
selected from IEC 61169-1, applicable to all detail specifications relating to series SMA RF
connectors.
This document indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The SMA types RF coaxial connectors are used with all kinds of RF cables and microstrips in
microwave transmission systems. The operating frequency is up to 18 GHz. These connectors
can be intermated with 3,5 mm (IEEE 287-2007) and 2,92 mm (IEC 61169-35) connectors.
NOTE Metric dimensions are original dimensions. All undimensioned pictorial configurations are for reference
purpose only.

Hochfrequenz-Steckverbinder – Teil 15: Koaxiale HF-Steckverbinder mit 4,13 mm (0,163 in) Innendurchmesser des Außenleiters und Schraubverriegelung – Wellenwiderstand 50 Ohm (Typ SMA) (IEC 61169-15:2021)

Connecteurs pour fréquences radioélectriques. Quinzième partie: Connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de 4,13 mm (0,163 in) à verrouillage à vis - Impédance caractéristique 50 ? (type SMA) (IEC 61169-15:2021)

IEC 61169-15:2021 fournit des informations et des règles en vue de l'établissement de spécifications particulières (DS - detail specification) relatives aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de 4,13 mm (0,163 in) à couplage fileté avec une impédance caractéristique de 50 Ω (type SMA).
Le présent document spécifie les dimensions des faces d’accouplement pour les connecteurs à haute performance – grade 1, les détails dimensionnels des connecteurs d’essai normalisés – grade 0, ainsi que des informations concernant les calibres et les essais choisis dans l’IEC 61169-1, applicables à toutes les spécifications particulières relatives aux connecteurs pour fréquences radioélectriques (RF) série SMA.
Le présent document indique les caractéristiques de performance recommandées à prendre en considération pour la rédaction d’une spécification particulière et il couvre les programmes d’essais et les exigences de contrôle relatifs aux niveaux d’assurance qualité M et H.

Radiofrekvenčni konektorji - 15. del: Področna specifikacija - Radiofrekvenčni (RF) koaksialni konektorji z notranjim premerom zunanjega vodnika 4,13 mm (0,163 in) z navojno sklopko - Karakteristična impedanca 50 ohm (tip SMA) (IEC 61169-15:2021)

General Information

Status
Published
Publication Date
07-Mar-2021
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
05-Mar-2021
Due Date
10-May-2021
Completion Date
08-Mar-2021

Buy Standard

Standard
EN IEC 61169-15:2021
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 61169-15:2021
01-maj-2021
Radiofrekvenčni konektorji - 15. del: Področna specifikacija - Radiofrekvenčni (RF)
koaksialni konektorji z notranjim premerom zunanjega vodnika 4,13 mm (0,163 in)
z navojno sklopko - Karakteristična impedanca 50 ohm (tip SMA) (IEC 61169-
15:2021)
Radio-frequency connectors. Part 15: Sectional specification - RF coaxial connectors
with inner diameter of outer conductor 4,13 mm (0,163 in) with threaded coupling -
Characteristic impedance 50 Ω (Type SMA) (IEC 61169-15:2021)
Hochfrequenz-Steckverbinder – Teil 15: Koaxiale HF-Steckverbinder mit 4,13 mm (0,163
in) Innendurchmesser des Außenleiters und Schraubverriegelung – Wellenwiderstand
50 Ohm (Typ SMA) (IEC 61169-15:2021)
Connecteurs pour fréquences radioélectriques. Quinzième partie: Connecteurs coaxiaux
pour fréquences radioélectriques avec diamètre intérieur du conducteur extérieur de
4,13 mm (0,163 in) à verrouillage à vis - Impédance caractéristique 50 ? (type SMA)
(IEC 61169-15:2021)
Ta slovenski standard je istoveten z: EN IEC 61169-15:2021
ICS:
33.120.30 Radiofrekvenčni konektorji RF connectors
(RF)
SIST EN IEC 61169-15:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 61169-15:2021

---------------------- Page: 2 ----------------------
SIST EN IEC 61169-15:2021


EUROPEAN STANDARD EN IEC 61169-15

NORME EUROPÉENNE

EUROPÄISCHE NORM
February 2021
ICS 33.120.30

English Version
Radio-frequency connectors - Part 15: Sectional specification -
RF coaxial connectors with inner diameter of outer conductor
4,13 mm (0,163 in) with threaded coupling - Characteristic
impedance 50 O (type SMA)
(IEC 61169-15:2021)
Connecteurs pour fréquences radioélectriques - Partie 15: Hochfrequenz-Steckverbinder - Teil 15: Koaxiale HF-
Spécification intermédiaire - Connecteurs coaxiaux pour Steckverbinder mit 4,13 mm (0,163 in) Innendurchmesser
fréquences radioélectriques avec diamètre intérieur du des Außenleiters und Schraubverriegelung -
conducteur extérieur de 4,13 mm (0,163 in) à couplage Wellenwiderstand 50 Ohm (Typ SMA)
fileté - Impédance caractéristique 50 O (type SMA) (IEC 61169-15:2021)
(IEC 61169-15:2021)
This European Standard was approved by CENELEC on 2021-02-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 61169-15:2021 E

---------------------- Page: 3 ----------------------
SIST EN IEC 61169-15:2021
EN IEC 61169-15:2021 (E)
European foreword
The text of document 46F/528(F)/FDIS, future edition 1 of IEC 61169-15, prepared by SC 46F “RF
and microwave passive components” of IEC/TC 46 “Cables, wires, waveguides, RF connectors, RF
and microwave passive components and accessories” was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN IEC 61169-15:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021–11–23
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024–02–23
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 61169-15:2021 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61169-35 NOTE Harmonized as EN 61169-35
2

---------------------- Page: 4 ----------------------
SIST EN IEC 61169-15:2021
EN IEC 61169-15:2021 (E)
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio frequency connectors - Part 1:EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62153-4-7 2015 Metallic communication cable testEN 62153-4-7 2016
methods - Part 4–7: Electromagnetic
compatibility (EMC) - Test method for
measuring of transfer impedance ZT and
screening attenuation a or coupling
s
attenuation ac of connectors and
assemblies up to and above 3 GHz -
Triaxial tube in tube method


3

---------------------- Page: 5 ----------------------
SIST EN IEC 61169-15:2021

---------------------- Page: 6 ----------------------
SIST EN IEC 61169-15:2021



IEC 61169-15

®


Edition 1.0 2021-01




INTERNATIONAL



STANDARD




NORME


INTERNATIONALE











Radio-frequency connectors –

Part 15: Sectional specification – RF coaxial connectors with inner diameter of

outer conductor 4,13 mm (0,163 in) with threaded coupling – Characteristic

impedance 50 Ω (type SMA)



Connecteurs pour fréquences radioélectriques –


Partie 15: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences

radioélectriques avec diamètre intérieur du conducteur extérieur de 4,13 mm

(0,163 in) à couplage fileté – Impédance caractéristique 50 Ω (type SMA)











INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 33.120.30 ISBN 978-2-8322-9257-0




Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------
SIST EN IEC 61169-15:2021
– 2 – IEC 61169-15:2021 © IEC 2021
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Mating face and gauge information . 6
4.1 Dimensions – High performance connectors – Grade 1 . 6
4.1.1 Connector with pin centre contact . 6
4.1.2 Connector with socket centre contact . 7
4.2 Gauge pin for socket centre contact . 9
4.3 Dimensions – Standard test connectors – Grade 0 . 9
4.3.1 Connectors with pin centre contact . 9
4.3.2 Connector with socket centre contact . 11
5 Quality assessment procedures . 12
5.1 General . 12
5.2 Ratings and characteristics . 12
5.3 Test schedule and inspection requirements. 16
5.3.1 Acceptance tests . 16
5.3.2 Periodic tests . 16
5.3.3 Procedures for the quality conformance . 18
6 Instructions for preparation of detail specifications . 18
6.1 General . 18
6.2 Identification of the component . 18
6.3 Performance . 18
6.4 Marking, ordering information and related matters . 19
6.5 Selection of tests, test conditions and severities . 19
6.6 Blank detail specification pro-forma for SMA connectors . 19
Bibliography . 24

Figure 1 – Connector with pin centre contact (for dimensions, see Table 1) . 6
Figure 2 – Connector with socket centre contact (for dimensions, see Table 2) . 8
Figure 3 – Gauge pin for socket centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin centre contact (for dimensions, see Table 4) . 10
Figure 5 – Connector with socket in centre contact (for dimensions, see Table 5) . 11

Table 1 – Dimensions of connector with pin centre contact . 7
Table 2 – Dimensions of connector with socket centre contact . 8
Table 3 – Dimensions of gauge pin for socket centre contact . 9
Table 4 – Dimensions of connector with pin centre contact . 10
Table 5 – Dimensions of connector with socket centre contact . 11
Table 6 – Preferred climatic categories . 12
Table 7 – Ratings and characteristics . 12
Table 8 – Acceptance tests . 16
Table 9 – Periodic tests . 17

---------------------- Page: 8 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 15: Sectional specification – RF coaxial connectors with inner
diameter of outer conductor 4,13 mm (0,163 in) with threaded coupling –
Characteristic impedance 50 Ω (type SMA)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
Governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-15 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
RF connectors, RF and microwave passive components and accessories.
This first edition cancels and replaces IEC 60169-15 published in 1979 and the amendment 1
published in 1996. This edition constitutes a technical revision.

---------------------- Page: 9 ----------------------
SIST EN IEC 61169-15:2021
– 4 – IEC 61169-15:2021 © IEC 2021
The text of this International Standard is based on the following documents:
FDIS Report on voting
46F/528/FDIS 46F/541/RVD

Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 10 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 5 –
RADIO-FREQUENCY CONNECTORS –

Part 15: Sectional specification – RF coaxial connectors with inner
diameter of outer conductor 4,13 mm (0,163 in) with threaded coupling –
Characteristic impedance 50 Ω (type SMA)



1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with inner diameter
of outer conductor 4,13 mm (0,163 in) with threaded coupling with a characteristic impedance
of 50 Ω (type SMA).
This document specifies mating face dimensions for high performance connectors – grade 1,
dimensional details of standard test connectors – grade 0, gauging information and tests
selected from IEC 61169-1, applicable to all detail specifications relating to series SMA RF
connectors.
This document indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The SMA types RF coaxial connectors are used with all kinds of RF cables and microstrips in
microwave transmission systems. The operating frequency is up to 18 GHz. These connectors
can be intermated with 3,5 mm (IEEE 287-2007) and 2,92 mm (IEC 61169-35) connectors.
NOTE Metric dimensions are original dimensions. All undimensioned pictorial configurations are for reference
purpose only.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 61169-1:2013, Radio frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 62153-4-7:2015, Metallic communication cable test methods – Part 4-7: Electromagnetic
and screening
compatibility (EMC) – Test method for measuring of transfer impedance Z
T
attenuation a or coupling attenuation a of connectors and assemblies up to and above
s c
3 GHz – Triaxial tube in tube method
3 Terms and definitions
No terms and definitions are listed in this document.

---------------------- Page: 11 ----------------------
SIST EN IEC 61169-15:2021
– 6 – IEC 61169-15:2021 © IEC 2021
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
4 Mating face and gauge information
4.1 Dimensions – High performance connectors – Grade 1
4.1.1 Connector with pin centre contact
The mating face of connector with pin centre contact is shown in Figure 1 and its dimensions
are shown in Table 1.

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Coupling nut in forward position.
NOTE 3 Hex 7,85/8,00 mm (0,309/0,315 in) width across flats, 3,18 mm (0,125 in) min flat length. It can extend
throughout the full length of the coupling nut. Other structures are also acceptable.
NOTE 4 Sealing ring.
NOTE 5 Spherical or chamfered.
Figure 1 – Connector with pin centre contact (for dimensions, see Table 1)

---------------------- Page: 12 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 7 –
Table 1 – Dimensions of connector with pin centre contact
mm in
Ref. Remarks
min max min max
a
3,43 0,135
b 3,30 - 0,129 9 -
c 0,38 1,14 0,015 0,045
d - 4,59 - 0,180 8
e 6,35 - 0,255 -
a
f - 0,08 - 0,003
b
0,00 0,009 8
g 0,00 0,25
h
0,00 0,25 0,00 0,009 8
j - - - -
k - 0,30 - 0,012
m 1,27 - 0,050 -
c
-
p  - -
d
- -
q - -
s 0,902 0,940 0,035 5 0,037 0
t 56° 70° 56° 70° Angle
a
0,08 mm (0,003 in) max, radius optional.
b
000 max projection.
c
Choose tolerance to give the requirement of 50 Ω. For non-center contact connector, dimension p may
deviate from the values given when the centre conductor of the cable is used as the contact pin. In this case,
the inner diameter of the outer conductor is identical to the outer conductor of the cable.
d
Dimension q should be such that the reference planes coincide, and the connectors meet the required
environmental performance.

4.1.2 Connector with socket centre contact
The mating face of connector with socket centre contact is shown in Figure 2 and its
dimensions are shown in Table 2.

---------------------- Page: 13 ----------------------
SIST EN IEC 61169-15:2021
– 8 – IEC 61169-15:2021 © IEC 2021

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Undercut acceptable, no fillet permitted.
Figure 2 – Connector with socket centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket centre contact
mm in
Ref. Remarks
min max min max
a 5,54 - 0,218 -
b 4,32 - 0,170 - Full thread
c 0,38 1,14 0,015 0,045
d 4,60 - 0,181 0 -
e 5,28 5,49 0,208 0,216
f 0,00 0,13 0 0,005
a
g 0,00 0,25 0 0,009 8
h 0,00 0,25 0 0,009 8
j 2,67 - 0,105 -
b
p - - - -
q 1,88 1,98 0,074 0,078
r 1,245 1,295 0,049 0,051
c
s - - - -
a
000 max projection. The dielectric is not allowed to protrude from the outer conductor.
b
Choose tolerance to give the requirement of 50 Ω.
c
Design of slotting is optional. It is chosen to meet return loss (RL), mating characteristics, and connector
durability requirements, when mated with a 0,902 mm to 0,940 mm (0,035 5 in to 0,037 0 in) gauge pin.

---------------------- Page: 14 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 9 –
4.2 Gauge pin for socket centre contact
The gauge pin for socket centre contact is shown in Figure 3 and its dimensions are shown in
Table 3.

Figure 3 – Gauge pin for socket centre contact (for dimensions, see Table 3)
Table 3 – Dimensions of gauge pin for socket centre contact
Gauge C, mass of gauge:
Gauge A Gauge B +2
28 g
0
Ref.
(For sizing purpose) (For insertion purpose) (For retention purpose)
min max min max min max
a 0,950 0,955 0,940 0,943 0,899 0,902
b 0,76 1,14 1,52 - 1,52 -
c 56° 64° 64° - - 56°
Material: steel, polished.

The test procedure is as follows:
a) Sizing test
The gauge A shall be inserted into the socket-centre contact three times. This is a sizing
operation and should only be carried out when the socket-centre contact is removed from
the connector.
b) Insertion test
Following the sizing operation, and if required in the detail specification, the force
necessary to insert gauge B fully into the socket-centre contact shall be measured. When
this test is required, the maximum permitted insertion force shall then be specified and
shall not exceed 13,3 N.
c) Retention test
After the sizing test, the gauge B shall be inserted into socket-centre contact. The contact
shall retain the mass of the gauge B in a vertical downward position.
4.3 Dimensions – Standard test connectors – Grade 0
4.3.1 Connectors with pin centre contact
The interface of connector with pin centre contact is shown in Figure 4, dimensions are shown
in Table 4.

---------------------- Page: 15 ----------------------
SIST EN IEC 61169-15:2021
– 10 – IEC 61169-15:2021 © IEC 2021

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Coupling nut in forward position.
Figure 4 – Connector with pin centre contact (for dimensions, see Table 4)
Table 4 – Dimensions of connector with pin centre contact
mm in
Ref. Remarks
Min. Max. Min. Max.
a 2,59 3,35 0,102 0,132
b 3,3 - 0,146 0,170
c
0,38 1,14 0,015 0,045
d 4,521 4,592 0,178 0 0,180 8
e 6,48 6,73 0,255 0,265
a
f - 0,08 - 0,003
g 0,00 0,05 0,000 0,002
h 0,00 0,076 0,000 0,003
j 2,03 2,29 0,080 0,090
m
1,27 - 0,050 -
b
p 4,102 4,127 0,161 5 0,162 5
q 2,03 - 0,080 -
b
r 1,27 (nominal value) 0,050 (nominal value)
s 0,902 0,927 0,035 5 0,036 5
t 56° 70° 56° 70° Angle
a
0,08 mm (0,003 in) × 45°, chamfer optional.
b
Choose to give the required performance 50 Ω ± 0,5 Ω. The given nominal diameter in the table is based on
the assumption that a PTFE dielectric having a dielectric constant of 2,02 is used.

---------------------- Page: 16 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 11 –
4.3.2 Connector with socket centre contact
The mating face of standard test connector with socket centre contact is shown in Figure 5
and its dimensions are shown in Table 5.

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Undercut acceptable, no fillet permitted.
Figure 5 – Connector with socket in centre contact (for dimensions, see Table 5)
Table 5 – Dimensions of connector with socket centre contact
mm in
Ref. Remarks
Min. Max. Min. Max.
a
5,54 - 0,218 -
b 3,81 - 0,150 - Full thread
c 0,38 1,14 0,015 0,045
d
4,597 4,666 0,181 0 0,183 7
e 5,283 5,49 0,208 0,216
f - 0,25 - 0,010
g 0,00 0,05 0,000 0,002
h 0,00 0,076 0,000 0,003
j 2,54 - 0,100 -
k 0,08 - 0,003 -
p
4,13 (nominal value) 0,162 7 (nominal value)
a
q 1,88 1,98 0,074 0,078
b
r 1,27 (nominal value) 0,050 (nominal value)
s
0,965 0,99 0,038 0,039
t 84° 96° 84° 96° Angle
a
Dimension q should be such that the reference planes coincide, and the connectors meet the required
environmental performance.
b
Choose to give the required performance 50 Ω ± 0,5 Ω. The given nominal diameter in the table is based on
the assumption that a PTFE dielectric having a dielectric constant of 2,02 is used.

---------------------- Page: 17 ----------------------
SIST EN IEC 61169-15:2021
– 12 – IEC 61169-15:2021 © IEC 2021
5 Quality assessment procedures
5.1 General
Subclauses 5.2 to 5.3 provide recommended ratings, performance and test conditions to be
considered when writing a detail specification (DS). They also provide an appropriate
schedule of tests with minimum levels of conformance inspection sampling, together with the
pro forma blank detail specification (BDS) and instructions for the preparation of a detail
specification.
5.2 Ratings and characteristics
Preferred climatic categories are given in Table 6.
The values indicated below are recommended for SMA series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated. Rating and characteristics are given in Table 7.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Table 6 – Preferred climatic categories
Climate type Grade * Temperature range Steady damp heat
40/85/21 A − 40 °C to + 85 °C 21 days
55/125/21 B − 55 °C to + 125 °C 21 days
55/155/56 C − 55 °C to + 155 °C 56 days
* To be included in the IEC type designation.

Table 7 – Ratings and characteristics
Remarks including any
IEC 61169-1:2013
Ratings and characteristics Value deviations from
Subclause
standard test methods
Electrical

Nominal impedance 50 Ω
a
Frequency range  Or upper frequency limit
of cable
Grade 1 connectors DC to 18 GHz
– flexible, straight styles DC to 12,4 GHz
– semi-rigid and semi-flexible, straight
DC to 18 GHz
styles
– right-angle styles DC to 12,4 GHz
c, d
Rated voltage at sea-level   (86 to 106) kPa
– flexible cable, dielectric nominal
335 V
diameter 2,95 mm (0,116 in)
– flexible cable, dielectric nominal
250 V
diameter 1,52 mm (0,060 in)
– flexible cable, dielectric nominal
170 V
diameter 0,84 mm (0,033 in)
50-141 type semi-rigid and semi-

335 V
flexible
– 50-086 type semi-rigid and semi-
250 V
flexible

---------------------- Page: 18 ----------------------
SIST EN IEC 61169-15:2021
IEC 61169-15:2021 © IEC 2021 – 13 –
Remarks including any
IEC 61169-1:2013
Ratings and characteristics Value deviations from
Subclause
standard test methods
4,4 kPa approximately
c, d
Rated v
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.