SIST EN 61076-3-116:2009
(Main)Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever (IEC 61076-3-116:2008)
Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever (IEC 61076-3-116:2008)
IEC 61076-3-116:2008 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this International Standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-116: Rechteckige Steckverbinder - Schutzgehäuse für die Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600 MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 - Ausführung 13 zu IEC 61076-3-106 - Bajonettkupplung mit Federklemme (IEC 61076-3-116:2008)
Connecteurs pour équipement électroniques - Exigences de produit - Partie 3-116: Connecteurs rectangulaires - Boîtiers de protection utilisés avec des connecteurs blindés et non blindés à 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des environnements industriels incorporant l’interface série 60603-7 - Variante 13 liée à la CEI 61076-3-106 - Levier de verrouillage (CEI 61076-3-116:2008)
La CEI 61076-3-116:2008 couvre les boîtiers de protection pour améliorer les connecteurs à 8 voies blindés et non blindés existants utilisant l'interface décrite dans la CEI 60603-7-2, la CEI 60603-7-3, la CEI 60603-7-4, la CEI 60603-7-5 et la CEI 60603-7-7 pour les caractéristiques IP65 et IP67 conformément à la CEI 60529, utilisés dans les environnements industriels. Les boîtiers couvrent différents mécanismes de verrouillage conformes à la présente norme internationale et une variété de configurations de montage et de types de sortie qui sont détaillés dans la CEI 60603-7.
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-116. del: Zaščitna ohišja pri 8-rednih zaslonjenih in nezaslonjenih konektorjih za frekvence nad 600 MHz za industrijska okolja, ki vključuje serijski vmesnik po IEC 60603-7 - Različica 13 v povezavi z IEC 61076-3-106 - Bajonetni sklop z vzmetno objemko (IEC 61076-3-116:2008)
General Information
- Status
- Published
- Publication Date
- 17-Dec-2008
- Technical Committee
- I11 - Imaginarni 11
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 28-Nov-2008
- Due Date
- 02-Feb-2009
- Completion Date
- 18-Dec-2008
Overview
EN 61076-3-116:2008 (IEC 61076-3-116) specifies protective housings for rectangular, 8‑way shielded and unshielded connectors that incorporate the IEC 60603‑7 series interface. The standard defines product requirements to upgrade existing 8‑way connectors to IP65 / IP67 ingress protection levels (per IEC 60529) for use in industrial environments and for data frequencies up to 600 MHz. This document specifically addresses Variant 13 (locking lever) related to IEC 61076‑3‑106.
Key topics
- Scope & purpose
- Protective housings to provide environmental protection (IP65/IP67) for 8‑way connectors in industrial use.
- Compatibility with IEC 60603‑7 series interfaces (shielded and unshielded).
- Mechanical and dimensional requirements
- Housing design options for both fixed and free connector arrangements (variant 13 covers locking‑lever types).
- Mounting configurations, caps and accessory details for sealed installations.
- Sealing and ingress protection
- Requirements and references to achieve IP65 and IP67 ratings for harsh environments.
- Electrical and transmission characteristics
- Intended for connector assemblies handling signals up to 600 MHz; transmission performance and related tests are included.
- Performance & testing
- Test schedules covering climatic, mechanical and electrical performance (e.g., contact resistance, mating cycles, voltage proof, derating).
- Reference to test methods from IEC series such as IEC 60068 and IEC 60512.
- Terminology & interfaces
- Aligns with IEC 60603‑7 family for contact arrangement and interface compatibility.
Applications
- Industrial automation and control systems requiring rugged, sealed connector solutions.
- Field equipment, machine tools, sensors and actuators where existing IEC 60603‑7 8‑way connectors need IP65/IP67 protection.
- OEMs, panel builders and machinery manufacturers specifying sealed data/power connector housings with a locking lever (variant 13).
- Retrofit projects upgrading installed connectors for harsh or outdoor industrial environments.
Who should use this standard
- Connector and enclosure manufacturers designing protective housings for 8‑way interfaces.
- Product designers and system integrators specifying ruggedized connector solutions.
- Test laboratories performing compliance testing to IEC/EN connector housing requirements.
- Procurement and compliance engineers ensuring products meet industrial ingress and electrical performance standards.
Related standards
- IEC/EN 60603‑7 series (8‑way connector interfaces)
- IEC 60529 (Degrees of protection - IP code)
- IEC 61076‑3‑106 (related variant specifications)
- IEC 60068, IEC 60512 (environmental and connector test methods)
Keywords: EN 61076-3-116, IEC 61076-3-116, protective housings, 8-way connector, IP65, IP67, IEC 60603-7, locking lever, industrial connectors, 600 MHz.
Frequently Asked Questions
SIST EN 61076-3-116:2009 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever (IEC 61076-3-116:2008)". This standard covers: IEC 61076-3-116:2008 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this International Standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
IEC 61076-3-116:2008 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this International Standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
SIST EN 61076-3-116:2009 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61076-3-116:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-116: Rechteckige Steckverbinder - Schutzgehäuse für die Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600 MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 - Ausführung 13 zu IEC 61076-3-106 - Bajonettkupplung mit Federklemme (IEC 61076-3-116:2008)Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever (IEC 61076-3-116:2008)31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN 61076-3-116:2008SIST EN 61076-3-116:2009en,fr01-januar-2009SIST EN 61076-3-116:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 61076-3-116 NORME EUROPÉENNE
EUROPÄISCHE NORM November 2008
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61076-3-116:2008 E
ICS 31.220.10 English version
Connectors for electronic equipment - Product requirements -
Part 3-116: Rectangular connectors -
Detail specification for protective housings
for use with 8-way shielded and unshielded connectors
for frequencies up to 600 MHz for industrial environments
incorporating the IEC 60603-7 series interface -
Variant 13 related to IEC 61076-3-106 - Locking lever (IEC 61076-3-116:2008)
Connecteurs pour équipements électroniques -
Exigences de produit -
Partie 3-116: Connecteurs rectangulaires -
Spécification particulière pour boîtiers de protection utilisés avec des connecteurs blindés
et non blindés à 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des environnements industriels incorporant l'interface série CEI 60603-7 -
Variante 13 liée à la CEI 61076-3-106 -
Levier de verrouillage (CEI 61076-3-116:2008)
Steckverbinder für elektronische Einrichtungen -
Produktanforderungen -
Teil 3-116: Rechteckige Steckverbinder -
Bauartspezifikation für Schutzgehäuse
für die Anwendung mit 8-poligen geschirmten
und ungeschirmten Steckverbindern
für Frequenzen bis 600 MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle
der Reihe IEC 60603-7 -
Ausführung 13 zu IEC 61076-3-106 -
Verriegelungshebel (IEC 61076-3-116:2008)
This European Standard was approved by CENELEC on 2008-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 61076-3-116:2009
at national level by publication of an identical
national standard or by endorsement
(dop) 2009-07-01 – latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2011-10-01 The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning Amphenol 1). The IEC and CENELEC take no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the IEC that he/she is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. Information may be obtained from: Amphenol Socapex S.A.S.
948 Promenade de l’Arve
B.P. 29
74311 Thyez cedex, France Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those identified above. IEC and CENELEC shall not be held responsible for identifying any or all such patent rights. Annex ZA has been added by CENELEC. __________ Endorsement notice The text of the International Standard IEC 61076-3-116:2008 was approved by CENELEC as a European Standard without any modification. __________
1) Amphenol is the trade name of Amphenol Socapex S.A.S. This information is given for the information of users of this International Standard and does not constitute an endorsement by IEC of the trademark holder or any of its products. Compliance to this profile does not require use of the trade name Amphenol. Use of the trade name Amphenol requires permission from Amphenol Socapex S.A.S. SIST EN 61076-3-116:2009
- 3 - EN 61076-3-116:2008
Annex ZA
(normative)
Normative references to international publications with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE
When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 60050-581 1978 International Electrotechnical Vocabulary (IEV) -
Chapter 581: Electromechanical components for electronic equipment - -
IEC 60068-1
- 1)Environmental testing -
Part 1: General and guidance EN 60068-1 1994 2)
IEC 60068-2-14 - 1) Environmental testing -
Part 2: Tests - Test N: Change of temperatureEN 60068-2-14 1999 2)
IEC 60068-2-30 - 1) Environmental testing -
Part 2-30: Tests -
Test Db: Damp heat, cyclic (12 h + 12 h cycle)EN 60068-2-30 2005 2)
IEC 60512-1 - 1) Connectors for electronic equipment - Tests and measurements -
Part 1: General EN 60512-1 2001 2)
IEC 60512-1-100 - 1) Connectors for electronic equipment - Tests and measurements -
Part 1-100: General - Applicable publications EN 60512-1-100 2006 2)
IEC 60529 - 1) Degrees of protection provided by
enclosures (IP Code) EN 60529 + corr. May
1991 2)1993
IEC 60603-7 - 1) Connectors for electronic equipment -
Part 7: Detail specification for 8-way, unshielded, free and fixed connectors EN 60603-7 200X 3)
IEC 60603-7-1 - 1) Connectors for electronic equipment -
Part 7-1: Detail specification for 8-way, shielded free and fixed connectors with common mating features, with assessed quality EN 60603-7-1 2002 2)
IEC 60603-7-2 - 1) Connectors for electronic equipment -
Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHzEN 60603-7-2 200X 3)
IEC 60603-7-3 - 1) Connectors for electronic equipment -
Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz EN 60603-7-3 200X 3)
1) Undated reference.
2) Valid edition at date of issue.
3) To be ratified.
Publication Year Title EN/HD Year
IEC 60603-7-4 - 1) Connectors for electronic equipment -
Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHzEN 60603-7-4 2005 2)
IEC 60603-7-5 - 1) Connectors for electronic equipment -
Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHzEN 60603-7-5 200X 3)
IEC 60603-7-7 - 1) Connectors for electronic equipment -
Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz EN 60603-7-7 2006 2)
IEC 60664-1 - 1) Insulation coordination for equipment within low-voltage systems -
Part 1: Principles, requirements and tests EN 60664-1 2007 2)
IEC 61076-1 - 1) Connectors for electronic equipment -
Product requirements -
Part 1: Generic specification EN 61076-1 2006 2)
IEC 61156-2 - 1) Multicore and symmetrical pair/quad cables for digital communications -
Part 2: Horizontal floor wiring - Sectional specification - -
IEC 61156-3 - 1) Multicore and symmetrical pair/quad cables for digital communications -
Part 3: Work area wiring - Sectional specification - -
IEC 61156-4 - 1) Multicore and symmetrical pair/quad cables for digital communications -
Part 4: Riser cables - Sectional specification - -
IEC 61076-3-116Edition 1.0 2008-09INTERNATIONAL STANDARD NORME INTERNATIONALEConnectors for electronic equipment – Product requirements –
Part 3-116: Rectangular connectors – Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to
600 MHz for industrial environments incorporating the IEC 60603-7 series interface – Variant 13 related to IEC 61076-3-106 – Locking lever
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 3-116: Connecteurs rectangulaires – Spécification particulière pour
boîtiers de protection utilisés avec des connecteurs blindés et non blindés à
8 voies pour des fréquences inférieures ou égales à 600 MHz dans des environnements industriels incorporant l’interface série CEI 60603-7 –
Variante 13 liée à la CEI 61076-3-106 – Levier de verrouillage
INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE SICS 31.220.10 PRICE CODECODE PRIXISBN 2-8318-9970-2
– 2 – 61076-3-116 © IEC:2008 CONTENTS FOREWORD.4 1 General data.6 1.1 Scope and object.6 1.2 Normative references.6 2 Terms and definitions.7 3 Dimensional information.7 3.1 Common features.7 3.2 General.8 3.3 Contact arrangement of all connector types.8 3.4 IP65 and IP67 sealing.8 3.5 Industrial IEC 60603-7 variant 13 – Locking lever.8 3.5.1 Industrial IEC 60603-7 variant 13, fixed connectors.8 3.5.2 Industrial IEC 60603-7 variant 13, free connectors.10 3.6 Termination and mounting information.11 3.7 General.11 3.8 Mounting information for variant 13, fixed connector.11 3.9 Cap for variant 13 fixed connector.12 4 Gauges.13 4.1 Connectors, IEC 60603-7 interface.13 5 Characteristics.13 5.1 Climatic category.13 5.2 Electrical.13 5.2.1 Clearance and creepage distances.13 5.2.2 Voltage proof.14 5.2.3 Current-derating diagram.14 5.2.4 Mating cycles with power applied.14 5.2.5 Initial contact resistance.14 5.2.6 Input-to-output resistance.15 5.2.7 Resistance unbalance.15 5.2.8 Initial insulation resistance.15 5.3 Transmission characteristics.15 5.3.1 General.15 5.3.2 Mechanical operation.15 5.3.3 Effectiveness of connector coupling devices transversal.15 5.3.4 Effectiveness of connector coupling devices.15 5.3.5 Separation and engagement forces.15 6 Test schedule.16 6.1 General.16 6.2 Test Procedures and measuring methods.16 6.3 Preconditioning.16 6.4 Wiring and mounting of specimens.16 6.4.1 Wiring.16 6.4.2 Mounting.16 6.5 Arrangement for contact resistance test:.17 6.6 Arrangement for dynamic stress tests (test phase AP2).17 6.7 Basic (minimum) test schedule.17 SIST EN 61076-3-116:2009
61076-3-116 © IEC:2008 – 3 – 6.8 Full test schedule.17 6.8.1 Test preliminary group P.17 6.8.2 Test group P.18 6.8.3 Test group AP.18 6.8.4 Test group BP.20 6.8.5 Test group CP.20 6.8.6 Test group DP.21 6.8.7 Test group EP.21
Figure 1 – Variant 13, fixed connector.9 Figure 2 – Variant 13, free connector.10 Figure 3 – Variant 13 mounting.11 Figure 4 – Variant 13 cap for fixed connector.12 Figure 5 – Connector derating diagram.14
Table 1 – Dimensions of fixed connector, variant 13.10 Table 2 – Dimensions of free connector, variant 13.11 Table 3 – Mounting information.12 Table 4 – Dimensions of cap for fixed connector variant 13.12 Table 5 – Climatic categories – Selected values for environmental performance level A.13 Table 6 – Minimum distances.13 Table 7 – Test group P.18 Table 8 – Test group AP – Dynamic/climatic.18 Table 9 – Test group BP – Mechanical.20 Table 10 – Test group CP – Continuity.20
– 4 – 61076-3-116 © IEC:2008 INTERNATIONAL ELECTROTECHNICAL COMMISSION ______________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-116: Rectangular connectors –
Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for
industrial environments incorporating the IEC 60603-7 series interface –
Variant 13 related to IEC 61076-3-106 – Locking lever
FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning Amphenol1. The IEC takes no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the IEC that he/she is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. Information may be obtained from: Amphenol Socapex S.A.S. 948 Promenade de l’Arve B.P. 29 74311 Thyez cedex, France ————————— 1 Amphenol is the trade name of Amphenol Socapex S.A.S. This information is given for the information of users of this International Standard
and does not constitute an endorsement by IEC of the trademark holder or any of its products. Compliance to this profile does not require use of the trade name Amphenol. Use of the trade name Amphenol requires permission from Amphenol Socapex S.A.S. SIST EN 61076-3-116:2009
61076-3-116 © IEC:2008 – 5 – Attention is drawn to the possibility that some of the e
...