SIST EN 15651-2:2017
(Main)Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing
Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing
This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications.
It covers glazing joints from 7° horizontal. Main areas of application are:
- glass to glass;
- glass to frame;
- glass to porous substrates.
Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).
Fugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen - Teil 2: Fugendichtstoffe für Verglasungen
Diese Europäische Norm legt Definitionen für und Anforderungen an nicht tragende, elastische Fugendichtstoffe für die Abdichtung von Verglasungen im Hochbau fest.
Sie erfasst Verglasungsfugen ab einem Winkel von 7° zur Horizontalen. Die Hauptbereiche, in denen diese Fugendichtstoffe eingesetzt werden, sind:
- Glas an Glas;
- Glas an Rahmen;
- Glas an porösen Trägermaterialien.
Anwendungen für Aquarien, tragende Verbindungen/Verglasungen, innere und äußere Abdichtungen von vorgefertigten Isolierglaseinheiten, horizontale Verglasungen (mit einer Neigung von weniger als 7°) und Verglasungen aus organischem Material (z. B. Polycarbonat, PMMA usw.) fallen nicht in den Anwendungsbereich dieser Europäischen Norm.
Mastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers - Partie 2 : Mastics pour vitrage
La présente Norme européenne spécifie des définitions et des exigences relatives aux mastics élastiques non structuraux utilisés pour le vitrage dans la construction immobilière.
Elle traite des joints pour vitrages au-delà de 7° par rapport à l'horizontale. Les principaux domaines d'application sont les suivants :
— verre sur verre ;
— verre sur châssis ;
— verre sur supports poreux.
Sont exclus les aquariums, les vitrages extérieurs collés, les mastics de scellement des vitrages isolants, les vitrages horizontaux (jusqu'à 7°), le verre organique (par exemple, polycarbonate, PMMA, etc.).
Tesnilne mase za nekonstrukcijske stike v stavbah in na površinah za pešce - 2. del: Tesnilne mase za zasteklitev
Ta evropski standard določa definicije in zahteve za nekonstrukcijske elastične tesnilne mase, ki se uporabljajo za zasteklitev pri gradnji stavb.
Zajema stike zasteklitve od 7° vodoravno. Glavna področja uporabe so:
– steklo na steklo;
– steklo na ogrodje;
– steklo na porozno podlago.
Ne vključuje akvarijev, strukturnega spajanja/zasteklitve, notranjega in zunanjega tesnjenja za izdelovanje izoliranih zastekljenih enot, vodoravne zasteklitve (pod 7°), organskega stekla (npr. polikarbonat, PMMA itd.).
General Information
- Status
- Published
- Public Enquiry End Date
- 19-Nov-2016
- Publication Date
- 07-Mar-2017
- Technical Committee
- VLA - Water proofing
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 28-Feb-2017
- Due Date
- 05-May-2017
- Completion Date
- 08-Mar-2017
Relations
- Effective Date
- 01-Apr-2017
Overview
EN 15651-2:2017 is the CEN European standard that defines requirements and test methods for non-structural elastic sealants used for glazing in building construction. It applies to glazing joints inclined from 7° horizontal and covers typical applications such as glass-to-glass, glass-to-frame, and glass-to-porous substrates. The standard excludes structural bonding/glazing, aquariums, manufacturing seals for insulated glazing units, horizontal glazing below 7°, and organic glass (e.g., polycarbonate, PMMA).
Key topics and technical requirements
EN 15651-2:2017 specifies what manufacturers and laboratories must assess to classify glazing sealants. Major technical topics include:
- Product identification: brand/type, chemical family, one- or multi-component, primer information.
- Physical / chemical tests:
- Thermogravimetric analysis on uncured sealant (EN ISO 11358)
- Density determination using pycnometer (EN ISO 2811-1)
- Hardness (Shore) on cured material (EN ISO 868)
- Mechanical and durability tests:
- Elastic recovery (EN ISO 7389) and tensile properties (EN ISO 8339 / EN ISO 8340)
- Resistance to flow (EN ISO 7390) and compression (EN ISO 11432)
- Adhesion/cohesion at maintained and variable extension, after water immersion and artificial weathering (EN ISO 9047, EN ISO 10590, EN ISO 11431)
- Change in mass and volume (EN ISO 10563)
- Performance classes: defined classes such as 25LM, 25HM, 20LM, 20HM with specific requirements for elongation, secant modulus, recovery and resistance to flow.
- Special conditions: provisions for cold-climate performance (lower temperature behaviour) and requirements for reaction to fire testing/assessment (references EN 13501-1 and EN ISO 11925-2).
- Conformity & marking: links to Assessment and Verification of Constancy of Performance (AVCP) and labelling requirements (see EN 15651‑5).
Applications and users
Who uses EN 15651-2:2017 and why:
- Sealant manufacturers - to develop, test and label glazing sealant products for the EU market.
- Façade engineers, architects and specifiers - to select compliant, non-structural glazing sealants for glass joints.
- Contractors and façade installers - to verify product suitability (glass-to-glass, glass-to-frame, porous substrates).
- Test laboratories and certification bodies - to perform required test methods and support AVCP.
- Regulatory authorities and procurement teams - to ensure products meet EU Regulation requirements (Annex ZA references).
Practical benefits include clearer product specification, predictable performance in service (including cold climates), and documented conformity for safety and procurement.
Related standards
- EN 15651‑1, ‑3, ‑4, ‑5 (other parts of the EN 15651 series; Part 5 covers evaluation of conformity and marking)
- EN ISO 11600 (classification and requirements for sealants)
- EN ISO 8339, 8340, 7389, 11432, 11358, 2811-1, 868 (test methods cited in the standard)
Keywords: EN 15651-2:2017, sealants for glazing, non-structural sealant, glazing joints, CEN standard, sealant testing, AVCP, façade sealants.
Frequently Asked Questions
SIST EN 15651-2:2017 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing". This standard covers: This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications. It covers glazing joints from 7° horizontal. Main areas of application are: - glass to glass; - glass to frame; - glass to porous substrates. Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).
This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications. It covers glazing joints from 7° horizontal. Main areas of application are: - glass to glass; - glass to frame; - glass to porous substrates. Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).
SIST EN 15651-2:2017 is classified under the following ICS (International Classification for Standards) categories: 91.100.50 - Binders. Sealing materials. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 15651-2:2017 has the following relationships with other standards: It is inter standard links to SIST EN 15651-2:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 15651-2:2017 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/474. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 15651-2:2017 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Tesnilne mase za nekonstrukcijske stike v stavbah in na površinah za pešce - 2. del: Tesnilne mase za zasteklitevFugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen - Teil 2: Fugendichtstoffe für VerglasungenMastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers - Partie 2 : Mastics pour vitrageSealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing91.100.50Veziva. Tesnilni materialiBinders. Sealing materialsICS:Ta slovenski standard je istoveten z:EN 15651-2:2017SIST EN 15651-2:2017en,fr,de01-april-2017SIST EN 15651-2:2017SLOVENSKI
STANDARDSIST EN 15651-2:20131DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15651-2
February
t r s y ICS
{ sä s r rä w r Supersedes EN
s w x w sæ tã t r s tEnglish Version
Sealants for nonæstructural use in joints in buildings and pedestrian walkways æ Part
tã Sealants for glazing Mastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers æ Partie
t ã Mastics pour vitrage
Fugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen æ Teil
tã Fugendichtstoffe für Verglasungen This European Standard was approved by CEN on
t w December
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s w x w sæ tã t r s y ESIST EN 15651-2:2017
European foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 5 4 Requirements . 6 4.1 Identification requirements and test methods . 6 4.1.1 Short description of the sealant . 6 4.1.2 Thermogravimetric test. 6 4.1.3 Density . 6 4.1.4 Hardness (indentation) test (Shore Hardness) . 6 4.2 Conditioning, test procedure and substrates . 7 4.3 Performance requirements . 7 4.3.1 General . 7 4.3.2 Sealants for glazing elements in cold climates . 8 4.3.3 Resistance to flow . 9 4.3.4 Resistance to water and UV . 9 4.3.5 Resistance to compression . 9 4.4 Release of dangerous substances . 9 4.5 Reaction to fire . 10 4.5.1 General . 10 4.5.2 Mounting and fixing conditions for test samples . 10 5 Durability . 12 6 Sampling . 12 7 Assessment and verification of constancy of performance . 12 7.1 General . 12 7.2 Product type determination . 12 7.3 Factory production control . 12 8 Marking and labelling . 12 Annex A (informative)
Example on the frequency of tests for factory production control . 13 Annex ZA (informative)
Relationship of this European Standard with Regulation (EU) No.305/2011 . 14 ZA.1 Scope and relevant characteristics . 14 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) . 16 ZA.3 Assignment of AVCP tasks . 16 Bibliography . 19
Test method Classes for non-structural sealants for glazing elements 25LM 25HM 20LM 20HM Elongationa EN ISO 7389 EN ISO 8339 EN ISO 8340 EN ISO 10590 EN ISO 11431 100 % 100 % 60 % 60 % Amplitude EN ISO 9047 ±25 % ±25 % ±20 % ±20 % Compression EN ISO 11432 25 % 25 % 20 % 20 % a The value of elongation is given as a percentage of the original width: elongation % = [(final width – original width) / (original width)] x 100 %. Substrates to be used in all mechanical tests concerned shall be glass according to ISO 13640. Additional substrates to be considered mortar are M1 or M2 and/or anodised aluminium. 4.3 Performance requirements 4.3.1 General Classes for elastic sealants for glazing in building construction are referred to as type G. A summary of the characteristics and classes are given in Table 2. SIST EN 15651-2:2017
...










Questions, Comments and Discussion