SIST EN 61169-35:2011/oprA1:2026
(Amendment)Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors
- Status
- Not Published
- Public Enquiry End Date
- 26-Nov-2026
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 08-Sep-2026
- Due Date
- 26-Jan-2027
SIST EN 61169-35:2011/oprA1:2026 is Amendment 1 to the sectional specification for 2,92 series RF connectors. It updates the connector ratings and characteristics used to define, test and compare these radio-frequency connectors, including the addition of Grade 0 connectors. Engineers, quality teams and buyers use it to match connector grade, style and test method to the intended RF application.
What does SIST EN 61169-35:2011/oprA1:2026 specify?
SIST EN 61169-35:2011/oprA1:2026 specifies an amendment to the 2,92 series RF connector sectional specification. Its main purpose is to revise the performance table for these connectors and to add Grade 0 connectors for higher-frequency use.
The document is organized around a short purpose statement, a replacement for Table 6, and a technical rationale that explains why the frequency coverage is being extended. The revised table brings together electrical, mechanical, environmental and endurance ratings in one place so users can check suitability against a required application.
What are the key requirements of SIST EN 61169-35:2011/oprA1:2026?
SIST EN 61169-35:2011/oprA1:2026 updates the key rating table for 2,92 series RF connectors and ties each rating to a test method from IEC 61169-1. In practice, the document is mainly a qualification and selection reference: it tells you what performance has to be demonstrated and which connector variants need a separate check.
Electrical performance
- Table 6 sets the nominal impedance and separates the connector grades by frequency range, including the newly added Grade 0 connectors. In practice, the grade must match the operating band of the system, especially where higher-frequency measurement coverage is needed.
- The table gives reflection factor limits under subclause 9.2.1 and distinguishes straight styles from right-angle, component mounting, solder bucket and PCB mounting styles. This matters because not every mechanical style has the same RF performance, so the detail specification has to be checked for the exact variant.
- The electrical checks also cover centre contact resistance, outer conductor continuity and insulation resistance before and after conditioning. This means users have to verify that electrical contact quality stays acceptable after environmental stress.
Withstand voltage, screening and mechanical integrity
- Table 6 includes proof voltage and environmental test voltage requirements, with separate values for sea level and low-pressure conditions and different cable constructions. In practice, altitude and cable type affect the test plan and the acceptable assembly.
- Screening effectiveness is specified for straight cables only, and only when the interfaces are fully mated. That tells users that shielding performance is an assembly property, not just a connector body property.
- Mechanical checks cover gauge retention, centre contact captivation, engagement and separation, coupling torque, tensile strength of the coupling mechanism, vibration and shock. These tests matter because they show whether the connector can be assembled, mated and handled without loosening or damage.
Environmental and endurance performance
- The table includes climatic categories, sealing requirements for non-hermetic and hermetic versions, salt mist exposure, mechanical endurance and high-temperature endurance. In practice, these ratings help users decide whether the connector is suitable for the intended operating environment and service life.
- Several notes in the table say that ratings can depend on the cable used and that some limits are governed by the cable specification. This means the connector cannot be selected in isolation - the cable assembly has to be considered with it.
What terms does SIST EN 61169-35:2011/oprA1:2026 define?
- Grade 0 connectors - the connector grade added by this amendment for the extended frequency use case.
- Grade 1 connectors - the existing connector grade retained in the rating table.
- detail specification (DS) - the product-specific document to consult when the table says "See DS" for a particular style or condition.
- Climatic category - the code used to describe the temperature and humidity service profile for qualification.
- Hermetic - a sealing condition intended for gas-tight performance with a tighter leakage limit.
- Non-hermetic - a sealing condition with a looser leakage limit than hermetic sealing.
- Reflection factor - the RF measure used here to express how well the connector matches the line and limits reflected energy.
Who uses SIST EN 61169-35:2011/oprA1:2026?
SIST EN 61169-35:2011/oprA1:2026 is used by connector designers, cable assembly manufacturers, test laboratories, quality teams and procurement staff. It is especially relevant in RF and microwave work where 2,92 series connectors are used for qualification, incoming inspection, product definition and supplier comparison.
It also matters to users working on high-frequency measurement and 5G-related applications, because the amendment rationale links the added Grade 0 connector to wider frequency coverage.
What changed in SIST EN 61169-35:2011/oprA1:2026 from the previous edition?
SIST EN 61169-35:2011/oprA1:2026 is Amendment 1 to IEC 61169-35:2011. The change note states that it adds Grade 0 connectors, updates the title and introductory text, and replaces Table 6. The rationale explains that the amendment extends the connector’s frequency coverage for the 5G use case discussed in the document.
Which standards are used with SIST EN 61169-35:2011/oprA1:2026?
IEC 61169-1 is the companion standard named in the table, and it provides the standard test methods used for the electrical, mechanical and environmental checks. SIST EN 61169-35:2011/oprA1:2026 builds on IEC 61169-35:2011, which it amends.
What does the SIST EN 61169-35:2011/oprA1:2026 document contain?
SIST EN 61169-35:2011/oprA1:2026 contains the amendment notice, the purpose statement, the revised Table 6 and a short technical justification for the change. The table brings together the connector ratings and characteristics used for design review, qualification and product verification.
It also includes notes that explain how cable type, connector style and mating condition affect the stated performance. These notes are important because they tell the reader when a rating applies to the connector alone and when it depends on the complete assembly.
Relations
- Effective Date
- 23-Sep-2025
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 61169-35:2011/oprA1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors". This standard covers: Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors
Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors
SIST EN 61169-35:2011/oprA1:2026 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61169-35:2011/oprA1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 61169-35:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 61169-35:2011/oprA1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2026
Radiofrekvenčni konektorji - 35. del: Področna specifikacija za RF konektorje
serije 2.92 - Dopolnilo A1
Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF
connectors
Hochfrequenz-Steckverbinder - Teil 35: Rahmenspezifikation für HF-Steckverbinder der
Baureihe 2,92
Connecteurs pour fréquences radioélectriques - Partie 35: Spécification intermédiaire
pour les connecteurs RF série 2,92
Ta slovenski standard je istoveten z: EN 61169-35:2011/prA1:2026
ICS:
33.120.30 Radiofrekvenčni konektorji RF connectors
(RF)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
46F/747/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61169-35/AMD1 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-09-04 2026-11-27
SUPERSEDES DOCUMENTS:
46F/718/RR
IEC SC 46F : RF AND MICROWAVE PASSIVE COMPONENTS
SECRETARIAT: SECRETARY:
United States of America Mr John Morelli
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
SC 46A
ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for Vote
(CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which t hey are
aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clau ses to
be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC c lauses.
(SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Amendment 1 – Radio-frequency connectors – Part 35: Sectional specification for 2,92 series RF connectors
PROPOSED STABILITY DATE: 2029
NOTE FROM TC/SC OFFICERS:
61169-35 revised to add Grade 0 connector to increase frequency/ added title and intro
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.
IEC 61169-35:2011/AMD1 © IEC 2026
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION
2 ____________
4 IEC 61169-35
6 Edition 1.0 2011-07
8 RADIO-FREQUENCY CONNECTORS –
9 Part 35: Sectional specification for 2,92 series RF connectors
12 AMENDMENT 1
14 Purpose of this amendment:
15 Addition of grade 0 connectors
16 This table replaces Table 6 in the current edition of IEC 61169-35 Edition 1.0 2011-07 as indicated.
18 Table 6 – Rating and characteristics
Remarks, deviations
IEC 61169-1
Rating and characteristics Values
from standard test
Subclause
method
Electrical
Nominal impedance
50
Frequency range DC~ 40 GHz Or upper frequency
limit of cable
Grade 1 connectors
Grade 0 connectors
DC~ 43,5 GHz
a
Reflection factor 9.2.1
General connectors
Grade 0 connectors
- straight styles DC~18 GHz:
40 GHz to 43,5 GHz
0,0501 max.
0,1259 max.
18 GHz to 26,5 GHz
0,0631 max
26,5 GHz to 40 GHz
0,1259 max.
- right-angle styles See DS
- component mounting styles See DS
- solder bucket and PCB mounting styles See DS
b
Centre contact resistance 9.2.3
- initial
3,0 m
- after conditioning
4,0 m
b
Outer conductor continuity 9.2.3
- initial 2,0 m
- after conditioning
3,0 m
Insulation resistance 9.2.5
- initial
5 000 M
- after conditioning
200 M
SIST EN 61169-35:2011
...