SIST EN 13166:2013+A2:2016
(Main)Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification
Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification
This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,40 m2⋅K/W or a declared thermal conductivity greater than 0,050 W/(m⋅K) at 10 °C are not covered by this standard.
This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 [3]).
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Phenolharzschaum (PF) - Spezifikation
Diese Europäische Norm legt die Anforderungen an werkmäßig hergestellte Produkte aus Phenolharzschaum mit oder ohne Kaschierung oder Beschichtung fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in Form von Platten und Laminaten hergestellt.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Platten verwendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als 0,40 m2⋅K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,050 W/(m⋅K) bei 10 °C ist.
Die vorliegende Norm gilt weder für in situ Dämmprodukte noch für Produkte, die zur Dämmung von haustechnischen und betriebstechnischen Anlagen (durch EN 14314 abgedeckt [3]) vorgesehen sind.
Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse phénolique (PF) - Spécification
La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en mousse phénolique, avec ou sans parements ou enduits de finition, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux et de produits feuilletés.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,40 m2·K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,050 W/(m·K) ne relèvent pas du domaine d'application de la présente norme.
Les produits isolants thermiques mis en oeuvre in situ et les produits destinés à être utilisés pour l'isolation thermique des équipements du bâtiment et des installations industrielles ne relèvent pas du domaine d'application de la présente norme (couvert par l’EN 14314 [3]).
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz fenolne pene (PF) - Specifikacija
Ta evropski standard določa zahteve za površinsko obdelane ali lakirane ali površinsko neobdelane ali nelakirane proizvode iz fenolne pene, ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani v obliki plošč in laminatov.
Proizvodi iz tega standarda se uporabljajo tudi v montažnih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane.
Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje.
Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom.
Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,40 m2 K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,050 W/(m K) pri 10 °C, v tem evropskem standardu niso zajeti.
Ta standard ne zajema toplotnoizolacijskih proizvodov, izdelanih na kraju samem, ter proizvodov za izolacijo gradbene opreme in industrijskih napeljav (zajema jih standard EN 14314 [3]).
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz fenolne pene (PF) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Phenolharzschaum (PF) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en mousse phénolique (PF) - SpécificationThermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13166:2012+A2:2016SIST EN 13166:2013+A2:2016en,fr,de01-september-2016SIST EN 13166:2013+A2:2016SLOVENSKI
STANDARDSIST EN 13166:2013+A1:20151DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13166:2012+A2
June 2016 ICS 91.100.60 Supersedes EN 13166:2012+A1:2015
English Version
Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse phénolique (PF) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Phenolharzschaum (PF) - Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014 and Amendment 2 approved by CEN on 23 February 2016.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13166:2012+A2:2016 E SIST EN 13166:2013+A2:2016
Determination of the declared values of thermal resistance and thermal conductivity . 24 A.1 General . 24 A.2 Input data . 24 A.3 Declared values . 24 Annex B (normative)
!Product type determination" (!PTD") and factory production control (FPC). 26 Annex C (normative)
Determination of the aged values of thermal resistance and thermal conductivity . 30 C.1 General . 30 C.2 Preparation of test sample . 31 C.3 Determination of the initial value of thermal conductivity . 31 C.4 Determination of the aged value of thermal conductivity . 31 C.5 Blowing agent . 33 C.6 Declaration of thermal resistance and thermal conductivity . 34 Annex D (informative)
Additional properties . 35 D.1 General . 35 D.2 Shear strength . 35 D.3 Cell gas composition . 35 Annex E (normative)
PF multi-layered thermal insulation products . 36 E.1 General . 36 E.2 Requirements . 36 E.3 Test methods . 37 E.4 Evaluation of conformity . 37 Annex ZA (informative)
!Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation". 38 Bibliography . 49
Tables Table 1 — Tolerances for length and width . 13 SIST EN 13166:2013+A2:2016
Figures Figure ZA.1 — !Example CE marking information of products under AVCP system 1 and system 3" . 48
is the water vapour diffusion resistance factor – N is the number of test results – R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2·K/W RD is the declared thermal resistance m2„K/W Ri is one test result of thermal resistance m2„K/W Ru Is the design thermal resistance m2·K/W Rmean is the mean thermal resistance m2„K/W a is the apparent density kg/m3 Sb is the deviation from squareness on length and width mm/m Sd is the deviation from squareness on thickness mm Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2„K/W SIST EN 13166:2013+A2:2016
AD is the symbol of the declared value of apparent density CC(i1/i2/y) c is the symbol of the declared level of compressive creep CS(Y) is the symbol of the declared level of compressive strength CV is the symbol of the declared value of closed cell content DS(N) is the symbol for the declared class for dimensional stability under constant normal laboratory conditions DS(T+) is the symbol of the declared value of dimensional stability at specified temperature DS(T–) is the symbol of the declared value of dimensional stability at –20 °C DS(TH) is the symbol of the declared value of dimensional stability under specified temperature and humidity conditions Li is the symbol for tolerance in length Wi is the symbol for tolerance in width MU is the symbol of the declared value of water vapour diffusion resistance factor T is the symbol of the declared class for thickness tolerance TR is the symbol of the declared level for tensile strength perpendicular to faces WL(P) is the symbol of the declared level for long term water absorption by partial immersion WS is the symbol of the declared level for short term water absorption Z is the symbol of the declared value for the water vapour resistance
Abbreviated terms used in this standard: PF is Phenolic Foam !PTD is Product Type Determination (previously named ITT for Initial Type Test)" SIST EN 13166:2013+A2:2016
¶
s rá r 50 to 100
¶
yá w > 100
¶
wá r 4.2.7 Reaction to fire of the product as placed on the market Reaction to fire classification of the product as placed on the market shall be determined in accordance with EN 13501-1 and the mounting and fixing rules given in EN 15715. Detailed information about the test conditions and the field of application as stated in the reaction to fire classification report shall be given in the manufacturer’s literature. This classification is compulsory and shall always be included in the CE marking label. 4.2.8 Durability characteristics 4.2.8.1 General The appropriate durability characteristics have been considered and are covered in 4.2.8.2 and 4.2.8.3 and, where appropriate, in 4.3.5 for compressive creep. 4.2.8.2 Durability of reaction to fire of the product as placed on the market against ageing/degradation The reaction to fire performance of PF products as declared by 4.2.7 does not change with time. 4.2.8.3 Durability of thermal resistance and thermal conductivity against ageing/degradation Any change in thermal conductivity and thickness of phenolic foam products with time is covered and considered for declaration by 4.2.1, together with Annex C for thermal conductivity and any change in the thickness is covered by at least one of the 4.3.2 dimensional stability tests, as relevant. 4.3 For specific applications 4.3.1 General If there is no requirement for a property described in 4.3 for a product in use, then the property does not need to be determined and declared by the manufacturer. SIST EN 13166:2013+A2:2016
% d % DS(N) EN 1603 23 °C, 50 % R.H. 0,5 - DS(23,90) EN 1604 48 h at 23 °C, 90 % R.H. 0,5 1,5 DS(70,-) EN 1604 48 h at 70 °C 1,5 3,0 DS(70,90) EN 1604 48 h at 70 °C, 90 % R.H. 1,5 1,5 DS(-20,-) EN 1604 48 h at -20 °C 1,5 1,5 The test DS(N), DS(70,-) and DS(23,90) need not be performed when the test DS(70,90) is used. 4.3.3 Compressive strength Compressive strength, m, shall be determined in accordance with EN 826. No test result for compressive strength, m, shall be less than the value given in Table 5 for the declared level. SIST EN 13166:2013+A2:2016
·
w r CS(Y) 100
·
s r r CS(Y) 120
·
s t r CS(Y) 150
·
s w r CS(Y) 175
·
s y w CS(Y) 200
·
t r r CS(Y) 300
·
u r r CS(Y) 400
·
v r r 4.3.4 Tensile strength perpendicular to faces Tensile strength perpendicular to faces, mt, shall be determined in accordance with EN 1607. No test result shall be less than the value, given in Table 6, for the declared level. Table 6 — Levels for tensile strength perpendicular to faces Level Requirement kPa TR40
·
v r TR50
·
w r TR60
·
x r TR70
·
y r TR80
·
z r TR90
·
{ r TR100
·
s r r TR150
·
s w r 4.3.5 Compressive creep Compressive creep, ct, and total thickness reduction, t, shall be determined after at least one hundred and twenty two days of testing at a declared compressive stress, c, given in steps of at least 1 kPa and the results extrapolated thirty times to obtain the declared levels in accordance with EN 1606. Test samples shall be conditioned in accordance with EN 12429. Compressive creep shall be declared in levels, i2, and the total thickness reduction shall be declared in levels, i1, with steps of 1 % at the declared stress. No test result shall exceed the declared levels at the declared stress. NOTE 1 Referring to the designation code CC (i1/i2/y) c, according to Clause 6, a declared level CC (3/2/10)50, for example, indicates a value not exceeding 2 % for compressive creep and 3 % for total thickness SIST EN 13166:2013+A2:2016
¶ 1,25 WS 2
¶ 1,00 WS 3
¶ 0,75 WS 4
¶ 0,50 WS 5
¶ 0,25 4.3.7.2 Long term water absorption by partial immersion Long term water absorption by partial immersion, Wlp, shall be determined in accordance with EN 12087. No test result shall exceed the value given in Table 8 for the declared level. Table 8 — Levels for long term water absorption by partial immersion Level Requirement kg/m2 WL (P) 1
¶ 3,00 WL (P) 2
¶ 2,00 WL (P) 3
¶ 1,50 WL (P) 4
¶ 1,00 WL (P) 5
¶ 0,50 SIST EN 13166:2013+A2:2016
shall exceed the declared value and no test result of Z shall be less than the declared value. Alternatively, the values quoted in EN ISO 10456 may be used. 4.3.9 Apparent density Apparent density, a, shall be determined in accordance with EN 1602. Test sample shall be conditioned in accordance with EN 12429. The manufacturer shall declare the measured value in kilograms per cubic metre. 4.3.10 Closed cell content Closed cell content (corrected), o, shall be determined in accordance with EN ISO 4590. Surface facings or natural skins shall be removed. No test result shall be less than 90 %. 4.3.11 Release of dangerous substances !National regulations on dangerous substances may require verification and declaration on release, and sometimes content, when construction products covered by this standard are placed on those markets. In the absence of European harmonized test methods, verification and declaration on release/content should be done taking into account national provisions in the place of use. NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/." 4.3.12 Reaction to fire of the product in standardized assemblies simulating end-use applications Reaction to fire classification of products, in standardized assemblies simulating end-use applications, shall be determined in accordance with EN 13501-1 and the mounting and fixing rules given in EN 15715. This classification offers the opportunity to give a complementary and optional declaration on reaction to fire for standard test configurations of assemblies which include the thermal insulation product. The number of the selected test configuration of assembly (Table 5 of EN 15715:2009) which is used in the test shall be quoted with the Euroclass. Detailed information about the test conditions and the field of application of the classification as stated in the reaction to fire classification report shall be given in the manufacturer’s literature. 4.3.13 Continuous glowing combustion NOTE A test method is under development and the standard will be amended when this is available. SIST EN 13166:2013+A2:2016
¶ 50 mm thick 100 × 100 5 > 50 mm thick 4.3.4 Tensile strength perpendicular to faces EN 1607 50 × 50 3 – 4.3.5 Compressive creep EN 1606 50 × 50 3
¶ 50 mm thick 100 × 100 3 > 50 mm thick 4.3.6 Bending strength EN 12089 See 6.1.2 in
EN 12089:1997 3 Method B 4.3.7 Short term water absorption EN 1609 200 × 200 3 Method A Long term water absorption EN 12087 200 × 200 3 Method 1A 4.3.8 Water vapour transmission EN 12086 See 6.1 in EN 12086:1997 3 – 4.3.9 Apparent density EN 1602 200 × 200 3 – 4.3.10 Closed cell content EN ISO 4590 100 × 30 × 30 3 Method 2 4.3.11 Release of dangerous substances b – – – SIST EN 13166:2013+A2:2016
...