Aerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 003: Open sleeve - Inside pressurized area - EMI protection 5 kA - Temperature range - 65 °C to 200 °C - Product standard

This European Standard specifies the characteristics of flexible 5 kA self-wrapping shielding (EMI) protection sleeves, to be installed inside pressurized areas on electrical cables or cable bundles, made from nickel plated copper strands and PPS (polyphenylene sulfide) monofilament.
Temperature range: - 65 °C to 200 °C.

Luft- und Raumfahrt - Elektrische Leitungen, Installation - Selbstschließender abschirmender (EMI) Schutzschlauch - Teil 003: Offener Schutzschlauch - Innerhalb Druckkabine - EMI Schutz 5 kA - Temperaturbereich -65 °C bis 200 °C - Produktnorm

Série aérospatiale - Câbles électriques, installation - Gaine de protection blindée (EMI) auto-fermable - Partie 003 : Gaine ouverte - Usage interne - Protection EMI 5 kA - Température d’utilisation – 65 °C à 200 °C - Norme de produit

Aeronavtika - Električni kabli, namestitev - Samoovojna zaslonska (EMI) zaščitna obojka - 003. del: Odprta obojka - V območju pod tlakom - EMI-zaščita 5 kA - Temperaturno območje od –65 °C do 200 °C - Standard za proizvod

Ta evropski standard določa značilnosti prožnih samoovojnih zaslonskih (EMI-zaščita 5 kA) zaščitnih obojk, ki se namestijo v območjih pod tlakom na električne kable ali snope kablov in so izdelani iz niti iz ponikljanega bakra ter monofilamenta PPS (polifenilen sulfida).
Temperaturno območje: –65 °C do 200 °C.

General Information

Status
Published
Publication Date
10-Jul-2017
Technical Committee
I13 - Imaginarni 13
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
15-Jun-2017
Due Date
20-Aug-2017
Completion Date
11-Jul-2017

Relations

Effective Date
14-Jun-2017
Effective Date
04-Feb-2015

Overview

EN 4674-003:2017 is a CEN product standard in the Aerospace series that defines requirements for open, self‑wrapping EMI protective sleeves intended for installation inside pressurized areas on electrical cables and cable bundles. The sleeves provide electromagnetic interference (EMI) shielding with a rated lightning/ surge capability of 5 kA and are specified for a temperature range of −65 °C to 200 °C. Materials specified are nickel‑plated copper strands and PPS (polyphenylene sulfide) monofilament with optional internal protective tape.

Key topics and technical requirements

  • Composition: PPS monofilaments + nickel‑plated copper strands; optional internal protective tape (ASTM D4894 Type IV, Grade 2).
  • Temperature range: −65 °C to 200 °C (suitable for inside pressurized aircraft zones).
  • EMI performance: Designed for 5 kA surge protection; transfer impedance must be below the standard’s Zt_max curve between 10 kHz and 100 MHz. Longitudinal inductance limit Lt_max = 2 nH/m and DC electrical resistance limits (Ro_max) are specified per size (e.g., size 05 Ro_max ≈ 6 mΩ/m; sizes 08–45 Ro_max ≈ 5 mΩ/m).
  • Dimensions & mass: Detailed size codes and maximum wall thickness, protected diameter ranges and linear mass are tabulated (sizes 05, 08, 13, 16, 19, 25, 32, 38, 45).
  • Mechanical & environmental tests: Includes sunlight (ISO 4892‑3), high temperature, fluid resistance, flammability (EN 3844‑1), rapid temperature change (TA = 200 °C / TB = −65 °C), dynamic cut‑through, vibration, smoke density and toxicity (EN 2825/EN 2826).
  • EMC and electrical tests: Transfer impedance per IEC 62153‑4‑3; lightning strike waveform (5 kA) per EN 2591‑214; salt mist 96 h (EN 2591‑307).
  • Marking and designation: Uses EN 4674‑001 / EN 4674‑002 conventions for identification, marking and minimum sleeve lengths.

Applications and users

  • Intended for EMI shielding of cable assemblies installed inside pressurized aerospace areas (e.g., aircraft pressurized compartments and equipment bays).
  • Typical users:
    • Aerospace electrical and systems engineers
    • Cable and harness manufacturers
    • Procurement/specification writers for airframe and avionics
    • Test laboratories qualifying EMI sleeves and materials
    • Quality and certification teams verifying compliance with CEN/ASD‑STAN aerospace standards

Related standards

  • EN 4674‑001 (technical specification) and EN 4674‑002 (general/product list)
  • EN 6059 series (protection sleeve test methods)
  • EN 2591‑214 / EN 2591‑307 (lightning, salt mist)
  • IEC 62153‑4‑3 (transfer impedance testing)
  • ISO 4892‑3 (UV/sunlight exposure)
  • ASTM D4894 (tape material specification)

Keywords: EN 4674‑003:2017, self‑wrapping shielding, EMI protective sleeve, aerospace, electrical cables, 5 kA, PPS, nickel plated copper, transfer impedance, inside pressurized area.

Standard

SIST EN 4674-003:2017 - BARVE

English language
10 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 4674-003:2017 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 003: Open sleeve - Inside pressurized area - EMI protection 5 kA - Temperature range - 65 °C to 200 °C - Product standard". This standard covers: This European Standard specifies the characteristics of flexible 5 kA self-wrapping shielding (EMI) protection sleeves, to be installed inside pressurized areas on electrical cables or cable bundles, made from nickel plated copper strands and PPS (polyphenylene sulfide) monofilament. Temperature range: - 65 °C to 200 °C.

This European Standard specifies the characteristics of flexible 5 kA self-wrapping shielding (EMI) protection sleeves, to be installed inside pressurized areas on electrical cables or cable bundles, made from nickel plated copper strands and PPS (polyphenylene sulfide) monofilament. Temperature range: - 65 °C to 200 °C.

SIST EN 4674-003:2017 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables; 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 4674-003:2017 has the following relationships with other standards: It is inter standard links to SIST EN 4674-003:2015, SIST EN 4674-003:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 4674-003:2017 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen, Installation - Selbstschließender abschirmender (EMI) Schutzschlauch - Teil 003: Offener Schutzschlauch - Innerhalb Druckkabine - EMI Schutz 5 kA - Temperaturbereich -65 °C bis 200 °C - ProduktnormSérie aérospatiale - Câbles électriques, installation - Gaine de protection blindée (EMI) auto-fermable - Partie 003 : Gaine ouverte - Usage interne - Protection EMI 5 kA - Température d’utilisation – 65 °C à 200 °C - Norme de produitAerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 003: Open sleeve - Inside pressurized area - EMI protection 5 kA - Temperature range - 65 °C to 200 °C - Product standard49.060Aerospace electric equipment and systems29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 4674-003:2017SIST EN 4674-003:2017en,fr,de01-september-2017SIST EN 4674-003:2017SLOVENSKI
STANDARDSIST EN 4674-003:20151DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4674-003
June
t r s y ICS
v {ä r x r Supersedes EN
v x y væ r r uã t r s wEnglish Version
Aerospace series æ Electrical cablesá installation æ SelfæOpen sleeve æ Inside pressurized area æ EMI protection
w kA æ Temperature range æ
x w
¹C to
t r r
¹C æ Product standard Sßrie aßrospatiale æ Câbles ßlectriquesá installation æ Partie
r r u ã Gaine ouverte æ Usage interne æ Protection EMI
w kA æ Tempßrature d 5utilisation æ
x w
¹C à
t r r
¹C æ Norme de produit
Luftæ und Raumfahrt æ Elektrische Leitungená Schutzschlauch æ Teil
r r uã Offener Schutzschlauch æ Innerhalb Druckkabine æ EMI Schutz
w kA æ Temperaturbereich æ x w
¹C bis
t r r
¹C æ Produktnorm This European Standard was approved by CEN on
s r April
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
v x y væ r r uã t r s y ESIST EN 4674-003:2017
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...