Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows

This document covers hinged and pivoted steel (any kind) and aluminium based framed, glazed doorsets or openable windows. Throughout this document, the term "doorset" will be used to cover both doorsets and door assemblies. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests selected from those identified in Clause 4, the extended application can cover all or some of the following examples:
-   integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classification,
-   glazed elements including vision panels and framed glazed doorsets,
-   air transfer grilles (louvres and/or vents),
-   side, transom or over panels,
-   items of building hardware,
-   decorative and protective finishes,
-   intumescent seals and non-intumescent (smoke, draught or acoustic) seals,
-   alternative supporting construction(s).
This document does not cover horizontal doorsets.
The effect on the Classification ‘C’ for the doorsets following an extended application process is not addressed in this document.

Erweiterte Anwendung von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von Türen, Toren und zu öffnenden Fenstern einschließlich ihrer Baubeschläge - Teil 5: Feuerwiderstandsfähigkeit von verglasten Drehflügeltüren und zu öffnenden Fenstern mit Metall(rohr)rahmen

Dieses Dokument gilt für verglaste Drehflügeltüren und zu öffnende Fenster mit Rahmen aus Stahl (alle Stahlsorten) oder aus Aluminium. In diesem Dokument wird der Begriff "Tür" verwendet, um sowohl die Türelemente als auch die aus verschiedenen Elementen bestehende Türeinheit abzudecken. Es schreibt die Methodologie zur Erweiterung der Anwendung von Ergebnissen der Prüfung(en) der Feuerwiderstandsfähigkeit nach EN 1634-1 vor.
In Abhängigkeit von der Durchführung der entsprechenden Prüfung oder Prüfungen, die aus den in Abschnitt 4 aufgeführten Prüfungen auszuwählen ist bzw. sind, kann der erweiterte Anwendungsbereich alle oder einige der nachstehend als Beispiele aufgeführten Bereiche abdecken:
-   Klassifizierungen von nicht wärmegedämmten Elementen (E) sowie von solchen mit Anforderungen an die Strahlung (EW) oder wärmegedämmten Elementen (EI1 oder EI2),
-   verglaste Elemente einschließlich Sichtfenster und gerahmte verglaste Türen,
-   Lüftungsbausteine (Lüftungsgitter und/oder -öffnungen),
-   Seitenteile, Oberteile mit oder ohne Kämpfer,
-   Baubeschlagselemente,
-   dekorative und Schutzbeschichtungen,
-   dämmschichtbildende Dichtungen und nicht dämmschichtbildende Dichtungen zur Behinderung von Rauchdurchtritt (Rauchschutz, Durchzug oder Schallübertragung),
-   alternative Tragkonstruktion(en).
Dieses Dokument behandelt keine horizontalen Türen.
Die Auswirkung auf eine "C" Klassifizierung für Türen im Rahmen eines erweiterten Anwendungsprozesses wird nicht in diesem Dokument behandelt.

Application étendue des résultats d’essais en matière de résistance au feu et/ou d’étanchéité à la fumée des blocs portes, blocs fermetures et ouvrants de fenêtre, y compris leurs éléments de quincaillerie intégrés - Partie 5 : Résistance au feu des blocs portes vitrés battants et pivotants, à ossature métallique, et des fenêtres vitrées à ossature métallique

Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti za vrata, zaporne elemente in okna, ki se odpirajo, vključno z njihovim okovjem - 5. del: Požarna odpornost zastekljenih vrat v kovinskih okvirjih in oken, ki se odpirajo

General Information

Status
Not Published
Public Enquiry End Date
30-Jul-2024
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
06-Jun-2024
Due Date
24-Oct-2024

Relations

Buy Standard

Draft
prEN 15269-5:2024
English language
161 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2024
Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti
za vrata, zaporne elemente in okna, ki se odpirajo, vključno z njihovim okovjem - 5.
del: Požarna odpornost zastekljenih vrat v kovinskih okvirjih in oken, ki se
odpirajo
Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware -
Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and
openable windows
Erweiterte Anwendung von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder
Rauchdichtigkeit von Türen, Toren und zu öffnenden Fenstern einschließlich ihrer
Baubeschläge - Teil 5: Feuerwiderstandsfähigkeit von verglasten Drehflügeltüren und zu
öffnenden Fenstern mit Metall(rohr)rahmen
Application étendue des résultats d’essais en matière de résistance au feu et/ou
d’étanchéité à la fumée des blocs portes, blocs fermetures et ouvrants de fenêtre, y
compris leurs éléments de quincaillerie intégrés - Partie 5 : Résistance au feu des blocs
portes vitrés battants et pivotants, à ossature métallique, et des fenêtres vitrées à
ossature métallique
Ta slovenski standard je istoveten z: prEN 15269-5
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.50 Vrata in okna Doors and windows
91.190 Stavbna oprema Building accessories
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2024
ICS 13.220.50; 91.060.50 Will supersede EN 15269-5:2014+A1:2016
English Version
Extended application of test results for fire resistance
and/or smoke control for door, shutter and openable
window assemblies, including their elements of building
hardware - Part 5: Fire resistance of hinged and pivoted
metal framed glazed doorsets and openable windows
Application étendue des résultats d'essais en matière de Erweiterter Anwendungsbereich von Prüfergebnissen zur
résistance au feu et/ou d'étanchéité à la fumée des blocs- Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von
portes, blocs-fermetures et ouvrants de fenêtre, y compris Türen, Toren und Fenstern einschließlich ihrer
leurs éléments de quincaillerie intégrés - Partie 5: Baubeschläge - Teil 5: Feuerwiderstandsfähigkeit von
Résistance au feu des blocs- verglasten Drehflügeltüren und zu öffnenden Fenstern mit
Metall(rohr)rahmen
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 127.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATIO N

EUROPÄISCHES KOMITEE FÜR NORMUN G

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15269-5:2024 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Determination of the field of extended application . 7
4.1 General . 7
4.2 How to use extended application rules in Annex A. 8
4.3 Procedure for maximum field of extended application . 8
4.4 Analysis of resistance to fire test results . 9
5 Extended application report . 9
6 Classification report . 9
Annex A (normative) Construction parameter variations . 10
Annex B (normative) Arrangements for doorsets incorporating side and/or over panels . 152
Annex C (normative) Relationship showing the relevant Parts of EN 15269 that which
should be used depending upon the type of doorset . 156
Bibliography . 161

European foreword
This document (prEN 15269-5:2024) has been prepared by Technical Committee CEN/TC 127 “Fire
safety in buildings”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 15269-5:2014+A1:2016.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
This document is part of the EN 15269 series, Extended application of test results for fire resistance
and/or smoke control for door, shutter and openable window assemblies, including their elements of
building hardware.
A list of all parts in the EN 15269 series can be found on the CEN website: www.cencenelec.eu.
1 Scope
This document covers hinged and pivoted steel (any kind) and aluminium based framed, glazed
doorsets or openable windows. Throughout this document, the term “doorset” will be used to cover
both doorsets and door assemblies. It prescribes the methodology for extending the application of test
results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests selected from those identified in Clause 4, the
extended application can cover all or some of the following examples:
— integrity (E), integrity & radiation (EW) or integrity & insulation (EI or EI ) classification,
1 2
— glazed elements including vision panels and framed glazed doorsets,
— air transfer grilles (louvres and/or vents),
— side, transom or over panels,
— items of building hardware,
— decorative and protective finishes,
— intumescent seals and non-intumescent (smoke, draught or acoustic) seals,
— alternative supporting construction(s).
This document does not cover horizontal doorsets.
The effect on the Classification ‘C’ for the doorsets following an extended application process is not
addressed in this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 572-9, Glass in building - Basic soda lime silicate glass products - Part 9: Evaluation of
conformity/Product standard
EN 1155, Building hardware - Electrical powered hold-open devices for swing doors - Requirements and
test methods
EN 1363-1, Fire resistance tests - Part 1: General Requirements
EN 1634-1, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable
windows
EN 1634-2, Fire resistance and smoke control tests for door, shutter and openable window assemblies and
elements of building hardware - Part 2: Fire resistance characterisation test for elements of building
hardware
EN 1748-2-2, Glass in building - Special basic products - Glass ceramics - Part 2-2: Evaluation of
conformity/Product standard
EN 12365-2, Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain
walling - Part 2: Linear compression force test methods
EN 13024-2, Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of
conformity/Product standard
EN 13501-2, Fire classification of construction products and building elements - Part 2: Classification
using data from fire resistance and/or smoke control tests, excluding ventilation services
EN 15254-4, Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4:
Glazed constructions
EN 15269-1, Extended application of test results for fire resistance and/or smoke control for door, shutter
and openable window assemblies, including their elements of building hardware - Part 1: General
requirements
EN ISO 13943, Fire safety - Vocabulary (ISO 13943)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1363-1, EN ISO 13943,
EN 1634-1, EN 1634-2 and EN 15269-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at http://www.electropedia.org/
3.1
full scale test
test of a full scale doorset
Note 1 to entry: The method of reference for determining the fire resistance of the products in the scope of this
standard shall be EN 1634-1.
3.2
small scale test
test on elements of building hardware
Note 1 to entry: The method of reference for characterizing the influence on fire performance of items of
building hardware for incorporation into the products in the scope of this standard shall be EN 1634-2.
EN 1634-2 also defines the decision process that permits its use.
3.3
effective rebate depth
dimension of the door leaf thickness of overlapping adjacent edges of door leaf relative to the door
frame, transom or side panel or flush overpanel
Note 1 to entry: At the meeting edges and for rebated leaves this dimension will be the rebate where the
intumescent seal is fitted or, if no seal is fitted, the depth of the largest rebate (see Figure 1).
Key
x1 example of effective rebate depth in doorset to be tested
x2 example of resulting effective rebate depth during testing after movement of 20 mm
y1 example of over rebate to frame face clearance in doorset to be tested
y2 example of over rebate to frame face clearance in doorset after movement of 20 mm
Figure 1 — Effective rebate depth
3.4
opening outwards
means opening the door leaf away from the fireside
3.5
faces and sides of a hinged door leaf
the faces and sides of a hinged door leaf are shown in Figure 2

Key
1 opening face 4 hinge side
2 closing face 5 top side
3 lock side 6 bottom side
Figure 2 — Faces and sides of a hinged door leaf
3.6
representative
similar
door leaf design having ‘fundamentally the same’ or ‘similar’ construction as another door leaf design
for the purpose of evaluating parameter variations, providing the relevant aspects of tested
performance are considered
Note 1 to entry: See EN 15269-1 for further guidance on evaluation of ‘similar’/’fundamentally the same’.
4 Determination of the field of extended application
4.1 General
4.1.1 Before there can be any consideration for extended application, a representative doorset shall
have been tested in accordance with EN 1634-1 to achieve a test result which could generate a
classification in accordance with EN 13501-2 at least equal to the classification subsequently required
from extended application considerations.
4.1.2 A review of the doorset construction parameters can indicate that one or more characteristics
may be improved by a particular parameter variation. All evaluations shall be made on the basis of
retaining the classifications obtainable from testing to EN 1634-1, including those lower than the test
duration. However, this shall never lead to an increased classification for any specific parameter beyond
that achieved during any one resistance to fire test unles
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.