Self-supporting double skin metal faced insulating panels - Factory made products - Specifications

This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding;
b)   external walls and wall cladding;
c)   walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
This European Standard does not cover the following:
i.   sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C;
ii.   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii.   panels with perforated facing(s);
iv.   curved panels.

Selbstragende Sandwich-Elemente mit beidseitigen Metalldeckschichten - Werkmäßig hergestellte Produkte - Spezifikationen

Diese Europäische Norm legt Anforderungen an werkmäßig hergestellte selbsttragende Sandwichelemente mit beidseitigen Metalldeckschichten fest, die für elementweise Verlegung mit übergreifenden oder über-lappenden Längsfugen in den folgenden Anwendungen bestimmt sind:
a)   Dächer und Dachdeckungen;
b)   Außenwände und Wandbekleidungen;
c)   Wände (einschließlich Trennwänden) und (Unter )Decken innerhalb der Gebäudehülle.
Die von dieser Europäischen Norm abgedeckten Dämmkernwerkstoffe sind Polyurethan-Hartschaum, expandiertes Polystyrol, extrudierter Polystyrolschaum, Phenolharzschaum, Schaumglas und Mineralwolle.
ANMERKUNG   Polyurethan (PUR) schließt Polyisocyanurat (PIR) ein.
Dämmelemente (im Folgenden „Elemente“ genannt) mit Kantenausführungen, für die andere Werkstoffe als für den Hauptdämmkern verwendet werden, sind Gegenstand dieser Europäischen Norm.
Dämmelemente für Kühlhausanwendungen sind Gegenstand dieser Europäischen Norm. Elemente, die als Bauteil für ein Kühlhaus, für Gebäude und/oder als Bausatz für die Gebäudehülle in Verkehr gebracht werden, sind durch die ETA-Richtlinie 021 „Bausätze für Kühlhäuser“ abgedeckt.
Diese Europäische Norm gilt nicht für:
i)   Sandwichelemente mit einer deklarierten Wärmeleitfähigkeit des Dämmkerns  0,06 W/(m•K) bei 10 °C;
ii)   Produkte, die aus zwei oder mehr eindeutig festgelegten Schichten unterschiedlicher Dämmkern-werkstoffe bestehen (Mehrschicht-Produkte);
iii)   Elemente mit perforierter/ en Deckschicht(en);
iv)   gekrümmte Elemente.

Panneaux sandwiches autoportants, isolants, double peau à parements métalliques - Produits manufacturés - Spécifications

La présente Norme européenne spécifie les exigences applicables aux panneaux sandwiches manufacturés, autoportants, isolants, à deux parements métalliques, utilisés pour la pose en discontinu dans les cas suivants :
a)   couvertures et bardages ;
b)   parois extérieures et bardages de parois ;
c)   parois (y compris cloisons) et plafonds dans l’enveloppe du bâtiment.
Les matériaux d'âme isolante couverts par la présente Norme européenne sont : le polyuréthane rigide, le polystyrène expansé, la mousse de polystyrène extrudé, la mousse phénolique, le verre cellulaire et la laine minérale.
NOTE   Le polyuréthane (PUR) comprend le polyisocyanurate (PIR).
La présente Norme européenne inclut les panneaux dont les chants sont en matériaux autres que le matériau d'âme isolant principal.
Elle inclut également les panneaux utilisés dans des applications pour chambres froides. Les panneaux, mis sur le marché en tant que composant de chambre d'entreposage frigorifique, de bâtiment et/ou d'équipements d'enveloppe de bâtiment, font l'objet du guide 021 de l'ETA « Equipements de locaux d'entreposage frigorifique ».
La présente Norme européenne ne couvre pas ce qui suit :
i.   les panneaux sandwiches dont la conductivité thermique déclarée de l’âme isolante est supérieure à 0,06 W/m•K à 10°C ;
ii.   les produits comportant deux ou plusieurs couches clairement définies de différents matériaux d’âme isolante (multicouches) ;
iii.   les panneaux à parement(s) perforé(s) ;
iv.   les panneaux incurvés.

Samonosilne izolacijske sendvič plošče z obojestranskim kovinskim oplaščenjem - Tovarniško izdelani proizvodi - Specifikacije

Ta evropski standard določa zahteve za tovarniško izdelane samonosilne izolacijske sendvič plošče z obojestranskim kovinskim oplaščenjem, namenjene za nezvezno polaganje pri naslednjih uporabah:
a) strehe in strešne obloge;
b) zunanje stene in stenske obloge;
c) stene (vključno s predelnimi stenami) in stropi znotraj ovoja hiše.
Izolirni jedrni materiali iz tega evropskega standarda so togi poliuretan, ekspandirani polistiren, ekstrudirani polistiren, fenolna pena, penjeno steklo in mineralna volna.
OPOMBA: Poliuretan (PUR) zajema poliizocianurat (PIR).
Plošče s profili, pri katerih se uporabljajo različni materiali iz glavnega izolirnega jedra, so zajete v tem evropskem standardu. Plošče, ki se uporabljajo za hladilnice, so zajete v tem evropskem standardu. Plošče, ki so dane na trg kot sestavni del kompleta za hladilnice, stavbe in/ali ovoja hiše, so zajete v smernicah ETA 021 »Cold storage premises kits« (Kompleti za prostore hladilnic).
Ta evropski standard ne zajema naslednjega:
i. sendvič plošč z deklarirano toplotno prevodnostjo za izolirno jedro nad 0,06 W/mK pri 10 °C;
ii. izdelkov, ki jih sestavljata dve ali več jasno opredeljenih plasti različnih izolirnih jedrnih materialov (večplastni);
iii. plošč s perforiranimi oblogami;
iv. ukrivljenih plošč.

General Information

Status
Published
Publication Date
11-Dec-2013
Technical Committee
IKER - Ceramics
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
22-Nov-2013
Due Date
27-Jan-2014
Completion Date
12-Dec-2013

Relations

Effective Date
01-Jan-2014
Effective Date
01-Jan-2014
Effective Date
18-Jan-2023
Effective Date
18-Jan-2023
Effective Date
18-Jan-2023
Effective Date
17-Mar-2021
Effective Date
17-Mar-2021
Effective Date
10-Mar-2021
Effective Date
01-Dec-2018

Overview - SIST EN 14509:2014

SIST EN 14509:2014 specifies requirements for factory-made, self-supporting double skin metal faced insulating sandwich panels intended for discontinuous laying in roofs, external walls (and cladding), internal walls/partitions and ceilings within the building envelope. The standard covers panels with rigid insulating cores such as polyurethane (PUR/PIR), expanded polystyrene (EPS), extruded polystyrene (XPS), phenolic foam, cellular glass and mineral wool. It includes panels used in cold store applications (note: cold store kits are additionally covered by ETA‑Guideline 021).

The standard excludes panels whose core thermal conductivity is greater than 0.06 W/m·K at 10 °C, multi-layer cores, panels with perforated facings and curved panels.

Key technical topics and requirements

  • Component material requirements: metal facings, core materials, adhesives and bonding are specified for suitability and durability.
  • Mechanical performance: tests and limits for bending, shear, point and repeated loads, and panel resistance under design loads.
  • Thermal performance: methods for calculating thermal transmittance (U‑value) of panels and constituent materials.
  • Durability and long-term behaviour: creep, ageing, interaction of bending/support forces and service performance.
  • Fire characteristics: classification and testing requirements for reaction to fire and related safety.
  • Dimensional tolerances: permitted variations for production and installation.
  • Weather and permeability: water (driving rain) resistance, air permeability and water vapour transmission tests.
  • Acoustic properties: airborne sound insulation (Rw) and sound absorption coefficients.
  • Health and safety: specification on dangerous substances.
  • Conformity & quality control: requirements for Initial Type Testing (ITT), sampling, Factory Production Control (FPC) and use of family test data.
  • Extensive test methods: normative annexes detail tensile, compressive, shear, bending, creep, thermal, permeability and acoustic test procedures.

Practical applications and users

Who uses SIST EN 14509:2014:

  • Manufacturers of metal-faced sandwich panels for product design, testing and CE marking.
  • Architects and façade/roofing specifiers selecting panel types, U‑values and fire performance.
  • Structural and thermal engineers performing load and energy calculations.
  • Test laboratories carrying out ITT and FPC testing.
  • Building authorities, certifiers and contractors who verify compliance, installation and performance. Practical applications include insulated roofing, exterior cladding systems, internal partitions, cold store walls/ceilings and insulated building envelope components.

Related standards

  • ETA‑Guideline 021 - cold storage premises kits (for panels marketed as part of cold storage kits).
  • National adoptions of EN 14509 by CEN members (SIST is the Slovenian adoption).

Keywords: SIST EN 14509:2014, self-supporting double skin metal faced insulating panels, sandwich panels, thermal transmittance, fire characteristics, factory production control, initial type testing, PUR/PIR, EPS, XPS, mineral wool.

Standard

SIST EN 14509:2014

English language
175 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 14509:2014 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Self-supporting double skin metal faced insulating panels - Factory made products - Specifications". This standard covers: This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications: a) roofs and roof cladding; b) external walls and wall cladding; c) walls (including partitions) and ceilings within the building envelope. The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. NOTE Polyurethane (PUR) includes polyisocyanurate (PIR). Panels with edge details that utilise different materials from the main insulating core are included in this European Standard. Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”. This European Standard does not cover the following: i. sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C; ii. products consisting of two or more clearly defined layers of different insulating core materials (multi-layered); iii. panels with perforated facing(s); iv. curved panels.

This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications: a) roofs and roof cladding; b) external walls and wall cladding; c) walls (including partitions) and ceilings within the building envelope. The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. NOTE Polyurethane (PUR) includes polyisocyanurate (PIR). Panels with edge details that utilise different materials from the main insulating core are included in this European Standard. Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”. This European Standard does not cover the following: i. sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C; ii. products consisting of two or more clearly defined layers of different insulating core materials (multi-layered); iii. panels with perforated facing(s); iv. curved panels.

SIST EN 14509:2014 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 14509:2014 has the following relationships with other standards: It is inter standard links to SIST EN 14509:2007, SIST EN 14509:2007/AC:2009, oSIST prEN 14509-1:2021, oSIST prEN 14509-5:2021, oSIST prEN 14509-3:2021, oSIST prEN 14509-3:2021, oSIST prEN 14509-5:2021, oSIST prEN 14509-1:2021, oSIST prEN 14509-1:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 14509:2014 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC, 89/109/EEC, EUR-PUB; Standardization Mandates: M/121, M/122. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 14509:2014 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Selbstragende Sandwich-Elemente mit beidseitigen Metalldeckschichten - Werkmäßig hergestellte Produkte - SpezifikationenPanneaux sandwiches autoportants, isolants, double peau à parements métalliques - Produits manufacturés - SpécificationsSelf-supporting double skin metal faced insulating panels - Factory made products - Specifications91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 14509:2013SIST EN 14509:2014en,fr,de01-januar-2014SIST EN 14509:2014SLOVENSKI
STANDARDSIST EN 14509:2007/AC:2009SIST EN 14509:20071DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14509
October 2013 ICS 91.100.60 Supersedes EN 14509:2006English Version
Self-supporting double skin metal faced insulating panels - Factory made products - Specifications
Panneaux sandwiches autoportants, isolants, double peau à parements métalliques - Produits manufacturés - Spécifications
Selbstragende Sandwich-Elemente mit beidseitigen Metalldeckschichten - Werkmäßig hergestellte Produkte - Spezifikationen This European Standard was approved by CEN on 18 July 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14509:2013: ESIST EN 14509:2014

Testing procedures for material properties . 42 A.1 Cross panel tensile test . 42 A.1.1 Principle. 42 A.1.2 Apparatus . 42 A.1.3 Test specimens . 42 A.1.4 Procedure . 43 A.1.5 Calculations and results . 43 A.1.6 Cross panel tensile modulus at elevated temperature . 44 A.2 Compressive strength and modulus of the core material . 45 A.2.1 Principle. 45 A.2.2 Apparatus . 45 A.2.3 Test specimens . 45 A.2.4 Procedure . 45 A.2.5 Calculations and results . 45 A.3 Shear test on the core material . 46 A.3.1 Principle. 46 A.3.2 Apparatus . 46 A.3.3 Test specimens . 47 A.3.4 Procedure . 48 A.3.5 Calculations and results – short-term loading . 48 A.3.6 Test procedures, calculations and results – long term loading . 51 A.4 Test to determine the shear properties of a complete panel . 52 A.4.1 Principle. 52 A.4.2 Apparatus . 52 A.4.3 Test specimens . 53 A.4.4 Procedure . 54 A.4.5 Calculations and results . 54 A.5 Test to determine the bending moment capacity of a simply supported panel . 57 A.5.1 Principle. 57 A.5.2 Apparatus . 57 A.5.3 Test specimens . 60 A.5.4 Procedure . 60 A.5.5 Calculations and results . 61 A.6 Determination of the creep coefficient (3t) . 66 A.6.1 Principle. 66 A.6.2 Apparatus . 66 A.6.3 Test specimens . 66 A.6.4 Procedure . 66 A.6.5 Calculations and results . 67 A.7 Interaction between bending moment and support force . 68 A.7.1 Principle. 68 A.7.2 Apparatus . 69 A.7.3 Test specimens . 70 A.7.4 Procedure . 70 A.7.5 Calculations and results . 70 A.8 Determination of apparent core density and mass of panel . 71 A.8.1 Determination of apparent core density . 71 A.8.2 Determination of mass of a panel . 72 A.9 Test for resistance to point loads and repeated loads . 72 A.9.1 Panels subject to point loads . 72 A.9.2 Panels subject to repeated loads . 73 A.10 Calculation method for the determination of the thermal transmittance of a panel (U) . 75 SIST EN 14509:2014

Durability testing method for sandwich panels . 89 B.1 General . 89 B.2 Test DUR1 . 89 B.2.1 Principle . 89 B.2.2 Apparatus . 89 B.2.3 Test specimens . 89 B.2.4 Procedure . 90 B.2.5 Test results and acceptance criteria – DUR1 . 91 B.3 Test DUR2 . 91 B.3.1 Principle . 91 B.3.2 Apparatus . 91 B.3.3 Test specimens . 92 B.3.4 Procedure . 93 SIST EN 14509:2014

Fire performance tests – additional instructions and direct field of application . 101 C.1 Reaction to fire . 101 C.1.1 Fire test EN 13823 (SBI) – specimens and mounting and fixing . 101 C.1.2 Fire test EN ISO 11925-2 (ignitability test) . 104 C.1.3 Direct field of application of reaction to fire test results . 105 C.2 Fire resistance . 108 C.2.1 General . 108 C.2.2 Fire resistance test EN 1364-1 — Walls . 109 C.2.3 Fire resistance test EN 1365-2 — Roofs . 112 C.2.4 Field of application of fire resistance test results . 113 C.3 Fire tests CEN/TS 1187 - external fire performance for roofs . 114 C.3.1 Classification without further testing (CWFT) . 114 C.3.2 CEN/TS 1187 Method 1 test . 115 C.3.3 CEN/TS 1187 Method 2 test . 115 C.3.4 CEN/TS 1187 Method 3 test . 115 C.3.5 CEN/TS 1187 Method 4 test . 116 C.4 Determination of the amount and thickness of the adhesive layer . 116 C.4.1 General . 116 C.4.2 Measurements on a manufactured panel . 116 C.4.3 Measurements during production . 117 Annex Dwbnormativec
Dimensional tolerances . 119 D.1 General . 119 D.2 Dimensional tolerances . 119 D.2.1 Thickness of panel and joint conformity . 119 D.2.2 Deviation from flatness . 120 D.2.3 Depth of metal profile . 121 D.2.4 Depth of stiffeners on lightly profiled facings . 121 D.2.5 Length . 122 D.2.6 Cover width . 122 D.2.7 Deviation from squareness . 124 SIST EN 14509:2014

Design procedures. 128 E.1 Definitions and symbols . 128 E.1.1 Properties of a sandwich panel . 128 E.1.2 Symbols used in Annex E . 129 E.1.3 Sign convention used in Annex E . 131 E.2 General . 131 E.3 Actions . 132 E.3.1 General . 132 E.3.2 Permanent actions . 132 E.3.3 Variable actions . 132 E.3.4 Actions due to long term effects . 133 E.4 Resistance . 133 E.4.1 General . 133 E.4.2 Residual (rest) bending resistance at an intermediate support . 134 E.4.3 End support reaction capacity . 135 E.5 Combination rules . 136 E.5.1 General . 136 E.5.2 Ultimate limit state . 136 E.5.3 Combination of the effects of actions for the ultimate limit state . 137 E.5.4 Serviceability limit state . 137 E.5.5 Combination of the effects of actions for the serviceability limit states . 138 E.6 Combination coefficients and safety factors . 139 E.6.1 Combination coefficients . 139 E.6.2 Load factors . 139 E.6.3 Material factors . 140 E.7 Calculation of the effects of actions . 141 E.7.1 General . 141 E.7.2 Methods of analysis . 141 E.7.3 Static system, geometry and thickness . 146 E.7.4 Sandwich panels with plane or lightly profiled faces . 146 E.7.5 Sandwich panels with strongly profiled faces . 147 E.7.6 The influence of time on shear deformations of the core . 147 E.8 Panels with special profiles . 148 E.8.1 General . 148 E.8.2 Determination of the effective properties of the faces and the core . 148 E.8.3 Design of panels with special profiles. 148 Annex Fwbinformativec
Significant technical changes between this European Standard and the previous edition . 152 Annex ZAwbinformativec
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 156 ZA.1 Scope and relevant characteristics . 156 ZA.2 Procedures for the attestation of conformity of sandwich panels . 158 ZA.2.1 Systems of attestation of conformity . 158 ZA.2.2 Certificate and Declaration of Conformity . 161 ZA.3 CE Marking and labelling . 163 ZA.3.1 General . 163 SIST EN 14509:2014
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Die Norm SIST EN 14509:2014 beschreibt umfassend die Anforderungen für werkseitig hergestellte, selbsttragende, doppelschalige mit Metall verkleidete isolierende Sandwichpaneele. Diese Paneele sind speziell für die Verwendung in discontinuierlicher Verlegung konzipiert und finden Anwendung in Dächern und Dachverkleidungen, Außenwänden sowie Wandverkleidungen und Innendecken innerhalb der Gebäudehülle. Die regulierten Isolierkernmaterialien, darunter starrer Polyurethan, expandiertes Polystyrol, extrudiertes Polystyrolschaum, phenolisches Schaum, zellenglasiertes Material und Mineralwolle, bieten eine breite Palette an Isolierlösungen für verschiedene Bauanforderungen. Ein bemerkenswerter Vorteil dieser Norm ist die klare Definition der Materialien und deren spezifischer Anwendungen, was sowohl die Herstellung als auch die Qualitätssicherung der Produkte vereinfacht. Darüber hinaus wird die Flexibilität der Norm betont, da sie auch Paneelen mit unterschiedlichen Randdetails und solchen für den Einsatz in Kälteanlagen, die z.B. in Lebensmittelkühlräumen Verwendung finden, Rechnung trägt. Dies zeigt die Relevanz und Vielseitigkeit der Norm in der modernen Bauindustrie. Nichtsdestotrotz grenzt die Norm spezifische Produkte aus, wie Sandwichpaneele mit einer erklärten Wärmeleitfähigkeit des isolierenden Kerns über 0,06 W/m·K bei 10 °C sowie Produkte aus mehrschichtigen Isoliermaterialien. Diese Ausschlüsse fördern die Klarheit und die Fokussierung auf die entsprechenden Produktkategorien, was für Hersteller und Anwender gleichermaßen von Vorteil ist. Insgesamt bietet die SIST EN 14509:2014 eine solide Grundlage für die Herstellung und den Einsatz von Isolierpaneelen in unterschiedlichen Bauanwendungen und stellt sicher, dass diese den erforderlichen Anforderungen an Effizienz und Sicherheit entsprechen. Die Norm ist somit ein unverzichtbares Dokument für Fachleute, die in den Bereichen Bau und Isolierung tätig sind.

SIST EN 14509:2014は、自立型の二重皮膜金属製断熱パネルに関するヨーロッパの標準であり、工場製品に対する仕様を定めています。この標準は、屋根や外壁、建物の内装の壁や天井などの不連続設置に使用される断熱サンドイッチパネルの要件を網羅しています。 この標準の強みは、使用される断熱コア材料の多様性にあります。剛性ポリウレタン、膨張ポリスチレン、押出しポリスチレンフォーム、フェノールフォーム、細胞ガラス、鉱鉱ウールをカバーしており、様々なニーズに応じたパネルの選択を可能にします。また、パネルのエッジが主な断熱コア材料とは異なる材料を利用している場合も含まれているため、設計の柔軟性が高いと言えます。 さらに、冷蔵庫などの特定の用途に使用されるパネルもこの標準に従っており、冷却室用のコンポーネントとして市場に流通するパネルについても明確に規定されています。この点から、自立型の二重皮膜金属製断熱パネルの一貫した品質と性能を確保するものとなっています。 一方で、SIST EN 14509:2014は、断熱コアの熱伝導率が0.06 W/m•Kを超えるサンドイッチパネルや、異なる断熱コア材料から構成される多層パネル、 perforated facingを持つパネル、曲面パネルなど、特定の製品を対象外としています。これにより、標準の適用範囲が明確化され、必要な性能基準を満たした製品の提供に集中できるメリットがあります。 全体として、この標準は、工場製の断熱パネルに対する信頼性の高いガイドラインを提供しており、建設業界における重要な指針として大いに有用です。

SIST EN 14509:2014 표준은 공장에서 제조된 자립형 이중 스킨 금속 면에 단열 패널에 대한 요구 사항을 명시하고 있습니다. 이 표준의 적용 범위는 다양하며, 지붕 및 지붕 외장재, 외벽 및 외벽 외장재, 건물 외환 내의 벽(격벽 포함) 및 천장에 사용됩니다. 이러한 패널은 耐寒 보관 응용 프로그램에서 사용될 수 있으며, 이 표준은 냉장 보관실의 구성 요소로 판매되는 패널도 포함합니다. 이 표준의 강점 중 하나는 다양한 종류의 단열 코어 소재를 다룬다는 점입니다. 경질 폴리우레탄, 확장 폴리스티렌, 압출 폴리스티렌 폼, 페놀 폼, 셀룰러 유리 및 무기 섬유와 같은 다양한 단열 재료를 사용하는 패널에 대한 명확한 사양이 제공됩니다. 이러한 다양한 선택 가능성은 설계 유연성을 증가시키고, 다양한 건축 용도에 적합한 패널을 개발할 수 있는 기회를 제공합니다. 또한, 이 표준에서는 금속 판넬의 경계 세부정보에 대해 다른 재료를 사용할 수 있도록 허용하여, 보다 창의적인 디자인과 보다 나은 성능을 지닌 제품 개발이 가능합니다. 이러한 점은 건축 산업에서 요구되는 혁신적인 접근 방식을 지원하며, 신축 및 개조 프로젝트 모두에서 활용될 수 있는 잠재력을 높입니다. 이 표준은 또한 고온 및 저온 환경에서 사용하기 적합한 패널을 포함하고 있기 때문에, 산업 및 상업적 냉장 보관실 설계에서 중요한 기준이 됩니다. 공장에서 제조된 단열 패널을 선택할 때, SIST EN 14509:2014의 요구 사항을 충족하는 제품을 우선적으로 고려하는 것이 바람직합니다. 그럼에도 불구하고, SIST EN 14509:2014는 특정 범위의 제품에 대해서는 적용되지 않음을 명시합니다. 예를 들어, 단열 코어의 열 전도율이 0.06 W/m•K를 초과하는 샌드위치 패널, 다양한 단열 코어 재료로 구성된 멀티 레이어 제품, 구멍이 뚫린 패널 및 곡선 패널은 이 표준의 적용에서 제외됩니다. 이는 사용자가 이 표준을 통해 안전하게 사용할 수 있는 제품 범위가 명확히 구분되도록 합니다. SIST EN 14509:2014는 현대 건축 산업에서 단열 성능을 극대화하고, 다양한 응용 프로그램에 적합한 고품질의 패널을 제공하기 위한 중요한 기준으로 자리잡고 있습니다.

The SIST EN 14509:2014 standard provides comprehensive specifications for self-supporting double skin metal faced insulating panels that are factory-made. Its scope is well-defined, focusing on applications such as roofs, roof cladding, external walls, wall cladding, and ceilings within the building envelope. This versatility caters to a variety of construction needs, ensuring that the panels can be effectively utilized in multiple scenarios, thereby enhancing their market relevance. One of the primary strengths of this standard is its detailed specification on insulating core materials, which include rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass, and mineral wool. Such a diverse selection allows for the accommodation of varying thermal performance requirements and construction methodologies, promoting efficiency and sustainability in building practices. Additionally, the inclusion of panels that utilize different materials from the main insulating core demonstrates the standard's adaptability to innovate and evolving material technologies. The clear specification that cold store applications are encompassed within the standard's scope reinforces its practicality, providing essential guidelines for panels used in cold storage environments, thereby assuring compliance with the necessary regulatory frameworks. However, it is pertinent to note the exclusions listed in the standard, such as those related to panels with a higher thermal conductivity than 0.06 W/m•K, multi-layered products, perforated facing panels, and curved panels. By clearly delineating these exceptions, the standard sets precise boundaries that assist manufacturers and builders in selecting the right products for their intended applications. Overall, SIST EN 14509:2014 emerges as a pivotal standard for the production and application of self-supporting double skin metal faced insulating panels, striking a balance between comprehensive guidance and targeted limitations, which ultimately fosters product integrity and operational efficiency in the construction industry.

La norme SIST EN 14509:2014 établit des spécifications claires et précises pour les panneaux sandwich isolants à double peau en métal, destinés à des applications variées. Son champ d'application se concentre sur les produits fabriqués en usine, garantissant ainsi une uniformité de fabrication et de performance. Les exigences spécifiées englobent les toits et le bardage de toiture, les murs externes et le bardage mural, ainsi que les cloisons et les plafonds à l'intérieur de l'enveloppe du bâtiment. Un des points forts de cette norme réside dans la diversité des matériaux d'âme isolants qu'elle couvre. En effet, la norme intègre des matériaux tels que le polyuréthane rigide, le polystyrène expansé et extrudé, la laine minérale, ainsi que le verre cellulaire, offrant ainsi une grande flexibilité pour les concepteurs et les fabricants. De plus, la norme prend en compte les panneaux avec des détails de bord utilisant des matériaux différents de l'âme isolante principale, élargissant ainsi les possibilités de conception. La norme est particulièrement pertinente dans le contexte actuel de la construction durable, compte tenu de l'importance croissante de l'efficacité énergétique et de la performance thermique des bâtiments. En fournissant des critères rigoureux pour les panneaux utilisés dans les applications de stockage à froid, la norme garantit également que ces produits répondent aux exigences spécifiques des environnements contrôlés, renforçant ainsi leur fiabilité. En revanche, il est essentiel de noter que cette norme exclut certains types de panneaux, tels que ceux avec une conductivité thermique déclarée supérieure à 0,06 W/m•K à 10 °C, ainsi que les produits multicouches, les panneaux à revêtement perforé, et les panneaux courbes. Cette exclusion précise assure une clarté dans l'application de la norme et aide à établir des attentes réalistes pour les utilisateurs. En résumé, la norme SIST EN 14509:2014 est un document essentiel qui répond aux exigences actuelles en matière de construction et qui assure des performances de qualité pour les panneaux sandwich isolants. Son large éventail de matériaux et d'applications la rend d'une grande utilité pour les professionnels du bâtiment, tout en soulignant son rôle dans l'amélioration de l'efficacité énergétique des bâtiments modernes.