Abstract

This document specifies a method using ion-exchange chromatography with UV-VIS detection for the determination of hexavalent chromium (chromium(VI)) in organic and organo-mineral fertilizers.
The method specified is suitable to quantify the chromium(VI) content in organic and organo-mineral fertilizers down to 2 mg/kg dry matter.
The results obtained from this method are strictly dependent on the extraction conditions. Results obtained by using other extraction parameters (extraction solution, pH of the extraction solution, extraction time, extraction temperature, etc.) are not comparable with the results produced by the procedure described in this document.
This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where organic matter is present in at least one of the products in the blend. In case a fertilizing product blend is composed only of inorganic products, the European Standard for inorganic fertilizers or liming materials applies.
NOTE   Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

Status
Not Published
Public Enquiry End Date
01-Apr-2026
Technical Committee
KAT - Soil quality
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
17-Nov-2026
Due Date
05-Jan-2027
Completion Date
17-Nov-2026

Buy Documents

Draft

oSIST prEN 17778:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 17778:2026 is the SIST publication of the draft European Standard prEN 17778 from CEN. It specifies an ion-exchange chromatography method with UV-VIS detection for determining hexavalent chromium, chromium(VI), in organic and organo-mineral fertilizers and in fertilizing product blends that contain organic matter. It is aimed at laboratories, manufacturers, and control bodies that need a test method for product control and for checking compliance with the chromium(VI) requirement in Regulation (EU) 2019/1009.

What does kSIST FprEN 17778:2026 specify?

kSIST FprEN 17778:2026 specifies a laboratory method for measuring chromium(VI) in organic and organo-mineral fertilizers. The method is written around extraction, ion-exchange chromatography, calibration, recovery checking, calculation on a dry-matter basis, and reporting.

The scope also covers fertilizing product blends, but only when the blend contains at least two listed component types and at least one of the products contains organic matter. If a blend is made only of inorganic products, the standard for inorganic fertilizers or liming materials applies.

The document is organized into:

  • Clause 1 - scope
  • Clause 2 - normative references
  • Clause 3 - terms and definitions
  • Clause 4 - principle
  • Clauses 5 and 6 - reagents and apparatus
  • Clause 7 - procedure
  • Clause 8 - calculation and expression of results
  • Clause 9 - precision
  • Clause 10 - test report
  • Annexes A, B, C and ZA
AnnexWhat it covers
Annex AInter-laboratory study results and precision data
Annex BExample chromatographic conditions for direct detection
Annex CExample chromatographic conditions for post-column reaction
Annex ZALink between the standard and Regulation (EU) 2019/1009

What are the key requirements of kSIST FprEN 17778:2026?

The standard is built around one main analytical route: extract chromium(VI) from the sample, then measure it by ion-exchange chromatography. In practice, that means the lab must control extraction conditions closely, because the result depends on them.

Extraction and sample handling

Clause 7 requires sample preparation according to EN 1482-2:2024, while sampling itself is handled separately. This matters because the test is only as representative as the sample that reaches the lab.

For solid samples, the procedure uses about 2 g of test material and a 30-minute extraction. For liquid samples, it uses about 10 g and a 10-minute extraction. The extract is filtered, the pH is checked, and the instrumental determination should follow as soon as possible and no later than 60 minutes after extraction.

Chemistry of the extraction

Clause 4 states that the extraction is carried out in phosphate buffer at pH 7.0 to 8.0, then the filtered extract is analysed for chromium(VI). The document also warns that results from other extraction solutions, pH values, times, or temperatures are not comparable.

That point matters in purchasing, quality control, and dispute work: the method is only valid when the same extraction conditions are used. If a product is re-tested elsewhere with a different extraction setup, the numbers may not match.

Instrumental measurement

Clause 7.3 allows two chromatographic approaches:

  • direct detection of the chromate peak at 372 nm
  • post-column reaction with 1,5-diphenylcarbazide and detection at 540 nm

The standard does not lock laboratories to one instrument layout. Instead, it gives tested examples in Annex B and Annex C, so laboratories can choose the route that fits their equipment.

Calibration and recovery check

Clause 7.4 uses external standard calibration. The lab prepares calibration solutions from the chromium(VI) standard solution and covers the expected measurement range.

Clause 7.5 requires a recovery-rate check to reveal matrix effects. The recovery must be between 80 % and 120 %. In practice, this is the document’s safeguard against misleading results caused by the fertilizer matrix or by reducing substances.

Calculation and reporting

Clause 8 requires results to be calculated on a dry-matter basis. The dry-matter content comes from prEN 17773:2026, so the chromium(VI) result and the moisture correction stay aligned.

The test report in Clause 10 must include the chromium(VI) content, the standard used, a sample description, the chromatographic technique, dry matter content, recovery rate, deviations from the procedure, and the analysis dates. That makes the result traceable for audits, conformity assessment, and customer documentation.

Precision data

Clause 9 points to an inter-laboratory study and gives repeatability and reproducibility limits. That is useful when comparing results between laboratories or deciding whether two measurements are close enough to be treated as the same.

What terms does kSIST FprEN 17778:2026 define?

  • chromium(VI) content (Cr(VI)) - the amount of hexavalent chromium measured after extraction with aqueous salt solution at pH 7.0 to 8.0, reported in mg/kg on dry mass.
  • recovery rate - the check used to show whether the matrix affects the result by comparing a spiked solution with the original sample extract.
  • dry matter - the mass fraction used to express the final chromium(VI) result on a dry basis.
  • direct detection method - the chromatographic approach that measures the chromate peak directly at 372 nm.
  • post-column reaction - the approach that reacts chromium(VI) with 1,5-diphenylcarbazide after the column and measures the coloured product at 540 nm.
  • fertilizing product blend - a blend of at least two listed fertilizing product types, with organic matter present in at least one product.
  • PFC 1(A) and PFC 1(B) - the product function categories in Regulation (EU) 2019/1009 that the standard links to organic and organo-mineral fertilizers.

Who uses kSIST FprEN 17778:2026?

This standard is used by laboratories that test fertilizers for chromium(VI) content. It is also relevant to fertilizer producers, importers, and quality managers who need product-release testing, incoming-material checks, or documentation for conformity assessment.

Control authorities and certification bodies use it when checking compliance with the chromium(VI) requirement in Regulation (EU) 2019/1009. It is especially relevant for organic fertilizers, organo-mineral fertilizers, and fertilizing product blends where matrix effects can influence the result.

What changed in kSIST FprEN 17778:2026 from the previous edition?

kSIST FprEN 17778:2026 supersedes CEN/TS 17778:2022. The foreword lists these significant changes:

  • adoption of the technical specification as a European Standard, including Annex ZA
  • updated introduction with the standards used as a basis and a description of Annexes A, B and C
  • clarified scope for fertilizing product blends
  • updated normative references and bibliography
  • updated principle
  • shorter extraction time in 7.2.1
  • Clause 8 aligned with prEN 17773:2026 for dry-matter calculation and expression
  • expanded test report requirements
  • Annex A added
  • Annexes B and C updated with replacement chromatograms

Which standards are used with kSIST FprEN 17778:2026?

The standard relies on several companion documents:

  • prEN 17773:2026 - provides the dry matter content used in the final result calculation.
  • prEN 12944-1:2026 and prEN 12944-2:2026 - provide the vocabulary used for fertilizers, liming materials and inhibitors.
  • EN 1482-2:2024 - gives the sample preparation provisions used before analysis.
  • EN 1482-1 and EN 1482-3 - are pointed to for sampling provisions.
  • prEN 17768 and prEN 17770 - are named for total chromium determination by aqua regia digestion and ICP-AES when a total-chromium route is used for comparison.
  • EN ISO 17075-2:2017 - is the source for the chromium(VI) term and the post-column reaction approach that influenced this standard.

What does the kSIST FprEN 17778:2026 document contain?

The document contains the full analytical workflow, from reagents and apparatus to reporting. Clause 7 gives the step-by-step procedure for solid and liquid samples, including extraction, filtration, pH checking, chromatographic analysis, calibration, and recovery verification.

It also contains the calculation formulas for chromium(VI) content, recovery rate, and dry-matter correction in Clause 8. Table 1 gives the calibration setup, and Table 2 gives repeatability and reproducibility data.

Annex A summarizes the inter-laboratory study used to establish precision. Annex B and Annex C provide example chromatographic conditions and chromatograms for the two analysis routes, which helps laboratories set up equipment and verify performance without reproducing the normative method text.

Relations

Effective Date
01-Mar-2026

Buy Documents

Draft

oSIST prEN 17778:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

FSC International

Forest Stewardship Council certification.

ASI Germany Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 17778:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Organic and organo-mineral fertilizers - Determination of chromium(VI) content". This standard covers: This document specifies a method using ion-exchange chromatography with UV-VIS detection for the determination of hexavalent chromium (chromium(VI)) in organic and organo-mineral fertilizers. The method specified is suitable to quantify the chromium(VI) content in organic and organo-mineral fertilizers down to 2 mg/kg dry matter. The results obtained from this method are strictly dependent on the extraction conditions. Results obtained by using other extraction parameters (extraction solution, pH of the extraction solution, extraction time, extraction temperature, etc.) are not comparable with the results produced by the procedure described in this document. This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where organic matter is present in at least one of the products in the blend. In case a fertilizing product blend is composed only of inorganic products, the European Standard for inorganic fertilizers or liming materials applies. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

This document specifies a method using ion-exchange chromatography with UV-VIS detection for the determination of hexavalent chromium (chromium(VI)) in organic and organo-mineral fertilizers. The method specified is suitable to quantify the chromium(VI) content in organic and organo-mineral fertilizers down to 2 mg/kg dry matter. The results obtained from this method are strictly dependent on the extraction conditions. Results obtained by using other extraction parameters (extraction solution, pH of the extraction solution, extraction time, extraction temperature, etc.) are not comparable with the results produced by the procedure described in this document. This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where organic matter is present in at least one of the products in the blend. In case a fertilizing product blend is composed only of inorganic products, the European Standard for inorganic fertilizers or liming materials applies. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

kSIST FprEN 17778:2026 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 17778:2026 has the following relationships with other standards: It is inter standard links to SIST-TS CEN/TS 17778:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 17778:2026 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 17778:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 chromium(VI) content
  • 4 Principle
  • 5 Reagents
  • 5.1 Extraction solution
  • 5.2 Phosphoric acid solution
  • 5.4 Chromium(VI) stock solution
  • 5.5 Chromium(VI) standard solution
  • 5.6 Argon or nitrogen, oxygen-free
  • 5.7 Distilled or deionised water, with a specific conductivity not higher than 0,2 mS/m at
  • 5.8 Magnesium chloride hexahydrate (MgCl⋅6H O)
  • 6 Apparatus
  • 6.7 Vacuum device, suitable for filtration of extraction solution, mobile phase, and sample
  • 6.8 Ion-exchange chromatograph, with UV/VIS detector or high-performance liquid
  • 7 Procedure
  • 7.1 Sampling and sample preparation
  • 7.2 Preparation of analytical solution
  • 7.3 Chromatographic conditions
  • Annex C have been successfully tested and used. Annex B determines chromium(VI) by direct
  • 7.4 Calibration
  • 7.5 Determination of the recovery rate
  • 8 Calculation and expression of results
  • 8.1 Calculation of chromium(VI) content
  • 8.2 Recovery rate (according to 7.5)
  • 8.3 Expression of results
  • 9 Precision
  • 9.1 Inter-laboratory study
  • 9.2 Repeatability
  • 9.3 Reproducibility
  • 10 Test report
  • Annex A
  • Annex B
  • Annex C
  • 2 LC pump
  • Annex ZA
  • Bibliography
  • 5 June 2019 laying down rules on the making available on the market of EU fertilising

Introduction

Regulation (EU) 2019/1009 [2] lays down the rules on the making available on the market of EU fertilizing products and the specific safety and quality requirements for the defined product function categories (PFCs). Organic and organo-mineral fertilizers have been classified as PFC 1(A) and PFC 1(B).

This document provides the method for the determination of the chromium(VI) extraction and determination as mentioned in Annex I, Part II, PFC 1(A) and PFC 1(B) of Regulation (EU) 2019/1009 [2] in order to measure the compliance with the related requirement in that Regulation.

Standards for determination of chromium(VI) in soil and waste [3], fertilizers [4] and for leather [1] were studied and considered as a basis of this document.

This document contains two annexes (B and C) which describe two possible ways for determining chromium(VI) by ion chromatography. Annex B describes an example of chromatographic conditions for the direct detection method, while Annex C explains the chromatographic conditions for method with post-column reaction. Both methods can be applied to determine chromium(VI). The choice depends on the equipment available in laboratories. The inter-laboratory study reflects the final statistical characteristics of the method for the determination of chromium(VI) content in organic and organo-mineral fertilizers. The results are given in Annex A (informative).

WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any national regulatory conditions.

IMPORTANT — It is absolutely essential that tests conducted according to this document are carried out by suitably trained staff.

oSIST prEN 17778:2026 prEN 17778:2026 (E)

1 Scope

This document specifies a method for the determination of hexavalent chromium (chromium(VI)) in organic and organo-mineral fertilizers.

The method specified is suitable to quantify the chromium(VI) content in organic and organomineral fertilizers down to 2 mg/kg dry matter. The results obtained from this method are strictly dependent on the extraction conditions. Results obtained by using other extraction procedures (extraction solution, pH of the extraction solution, extraction time, extraction temperature, etc.) are not comparable with the results produced by the procedure described in this document.

This document is applicable to fertilizing products blends where a blend is a mix of at least two of the following components: fertilizers, liming materials, soil improvers, growing media, inhibitors, plant biostimulants and where organic matter is present in at least one of the products in the blend. In case a fertilizing product blend is composed only of inorganic products, the European Standard for inorganic fertilizers or liming materials applies. Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

prEN 17773:2026, Organic and organo-mineral fertilizers — Determination of the dry matter content prEN 12944-1:2026, Fertilizers, liming materials and inhibitors — Vocabulary — Part 1: General terms prEN 12944-2:2026, Fertilizers, liming materials and inhibitors — Vocabulary — Part 2: Terms relating to fertilizers EN 1482-2:2024, Fertilizers, liming materials and inhibitors — Sampling and sample preparation - Part 2: general sample preparation provisions

3 Terms and definitions

For the purposes of this document, the terms and definitions given in prEN 12944-1:2026 and prEN 12944-2:2026 and the following apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/

oSIST prEN 17778:2026 prEN 17778:2026 (E)

3.1 chromium(VI) content

Cr(VI) amount of chromium(VI) in organic and organo-mineral fertilizers determined after extraction with an aqueous salt solution at pH 7,0 to pH 8,0 Note 1 to entry: The chromium(VI) content is reported as chromium(VI) in milligrams per kilogram (mg/kg), expressed as the dry mass of the sample.

[SOURCE: EN ISO 17075-2:2017 [1], 3.1, modified: “leather” is replaced by “organic and organomineral fertilizers”]

4 Principle

To prove the compliance with the limit value for chromium(VI) in organic and organo-mineral fertilizers, there is the possibility to choose between:

  • Using a testing method determining the total chromium content, as long as the result of the test shows a content below the limit value for chromium(VI). In such a case, it can be safely assumed that the organic fertilizer or the organo-mineral fertilizer complies with the limit value for chromium(VI).
  • Using a testing method which determines only chromium(VI) content. The determination of the total chromium in organic and organo-mineral fertilizers can be performed by aqua regia digestion (prEN 17768 [5]) and ICP-AES determination (prEN 17770 [6]).

This standard specifies the procedure to directly determine the content of chromium(VI) in organic and organo-mineral fertilizers: extractable chromium(VI) is leached from the sample in phosphate buffer at pH 7,0 to pH 8,0. An aliquot of the filtered extract is analysed for chromium(VI) using ion-exchange chromatography with UV-VIS detection.

5 Reagents

All reagents used shall have at least analytical grade.

5.1 Extraction solution

Dissolve 22,8 g dipotassium hydrogen phosphate trihydrate (K HPO ·3H O) in 1 000 ml water 2 4 2 (5.7), adjusted to pH 8,0 ± pH 0,1 with phosphoric acid solution (5.2). Degas this solution with either argon or nitrogen (5.6) or ultrasonic bath.

Standard practice is to make up a fresh solution each day. However, the solution can be kept for up to one week in a refrigerator at (4 ± 3) °C but shall be warmed to room temperature and degassed prior to use.

5.2 Phosphoric acid solution

700 ml o-phosphoric acid, density ρ = 1,71 g/ml, made up to 1 000 ml with water (5.7). First add approximately 200 ml of water (5.7) to a 1 000 ml volumetric flask, then add the 700 ml of o-phosphoric acid and dilute to the mark with water (5.7).

5.3 Potassium dichromate (K Cr O ), dried for (16 ± 2) h at (105 ± 2) °C. 2 2 7

oSIST prEN 17778:2026 prEN 17778:2026 (E)

5.4 Chromium(VI) stock solution

Dissolve 2,829 g potassium dichromate (K Cr O ) (5.3) in water (5.7) in a volumetric flask and 2 2 7 make up to 1 000 ml with water (5.7). 1 ml of this solution contains 1 mg of chromium. The solution can be kept for up to 12 months in a refrigerator at (4 ± 3) °C but shall be warmed to room temperature prior to use.

It is also possible to use a commercial standard solution with a certified Cr(VI) concentration that can be connected to national standards. Observe the expiry date or recommended shelf life stated by the manufacturer.

5.5 Chromium(VI) standard solution

Pipette 1 ml of solution (5.4) into a 1 000 ml volumetric flask and make up to the mark with extraction solution (5.1). 1 ml of this solution contains 1 μg of chromium. The solution can be kept for up to one week in a refrigerator at (4 ± 3) °C but shall be warmed to room temperature prior to use.

A stock solution of hexavalent chromium at this concentration level is an alternative available commercially.

5.6 Argon or nitrogen, oxygen-free

Preference should be given to argon as an inert gas instead of nitrogen because argon has a higher specific mass than air.

5.7 Distilled or deionised water, with a specific conductivity not higher than 0,2 mS/m at

25 °C, free from the elements to be determined.

5.8 Magnesium chloride hexahydrate (MgCl⋅6H O)

2 2 Dissolve 85,4 g of magnesium chloride hexahydrate (MgCl⋅6H O) in a 100 ml volumetric flask, 2 2 dilute with water (5.7), close and mix thoroughly.

6 Apparatus

Usual laboratory equipment and, in particular, the following.

−1 6.1 Suitable mechanical orbital shaker, (100 ± 10) min .

6.2 Conical flask, of capacity 250 ml, with stopper.

6.3 Aeration tube and flow meter, suitable for a flow rate of (50 ± 10) ml/min. 6.4 pH meter, with glass electrode.

6.5 Membrane filter, 0,45 μm pore size [polytetrafluoroethylene (PTFE) or polyamide 6.6]. 6.6 Common laboratory glassware and pipettes.

6.7 Vacuum device, suitable for filtration of extraction solution, mobile phase, and sample

extracts.

6.8 Ion-exchange chromatograph, with UV/VIS detector or high-performance liquid

chromatography (HPLC) with anion-exchange column and UV/VIS detector. A photo diode array detector (DAD) is recommended.

oSIST prEN 17778:2026 prEN 17778:2026 (E) 6.9 Analytical balance, capable of weighing to 0,1 mg.

6.10 Syringe membrane filters of polyamide 6.6 of 0,45 μm pore size, for filtration of standards. 6.11 Suitable vials for ion chromatography or HPLC.

7 Procedure

7.1 Sampling and sample preparation

Sampling is not part of the method specified in this document. Recommended sampling methods are given in EN 1482-1 [7] and in EN 1482-3 [8].

It is important that the laboratory receives a sample that is representative of both the product under consideration and the given analysis. The sample should not have been damaged or changed during transport or storage.

Sample preparation shall be carried out in accordance with EN 1482-2:2024. For products that can decompose or react when heated, grinding shall be carried out in order to prevent heating.

Details about the sampling and sample preparation shall be given in the test report.

7.2 Preparation of analytical solution

7.2.1 Solid samples

The operator shall weigh approximately (2 ± 0,1) g of sample of organic or organo-mineral fertilizer to the nearest 0,001 g with an analytical balance (6.9). Following tasks shall be performed:

  • Pipette 100 ml (V ) of degassed solution (5.1) into a 250 ml conical flask (6.2). Displace

oxygen by passing oxygen-free argon (or nitrogen) (5.6) into the flask for 5 min with a volume flow of (50 ± 10) ml/min. Remove the aeration tube (6.3), add the sample and close the flask with a stopper. Record the extract volume as V and the mass of the sample as m.

  • Shake the conical flask with the sample for (30,0 ± 0,5) min on a mechanical orbital shaker at −1 (100 ± 10) min (6.1) at room temperature to extract the chromium(VI).
  • Shake the suspension in a smooth circular movement to keep the sample from adhering to the wall of the flask and avoid shaking faster than specified.
  • Immediately after completing the 30 min of extraction, filter the contents of the conical flask through a membrane filter into a glass or plastic vessel with lid. Check the pH of the solution. The pH of the solution shall be between 7,0 and 8,0. If the pH of the solution is not within this range, start the complete procedure again. Consider using a smaller sample mass, if the pH is not between 7,0 and 8,0. In this case, the quantification limit will be increased.
  • Transfer an aliquot of the filtered extract into a vial (6.11). Instrumental determination of chromium(VI) should be performed as soon as possible and no later than 60 min after the extraction phase to avoid risks of reduction.
  • If the sample is expected to contain a significant amount of chromium(III), 1 ml of magnesium chloride solution (5.8) can be added before displacing oxygen into the 250 ml volumetric flask (6.2) containing the 100 ml of the extraction solution (5.1).

oSIST prEN 17778:2026 prEN 17778:2026 (E)

7.2.2 Liquid samples

The operator shall weigh approximately (10 ± 0,1) g of sample of organic or organo-mineral fertilizer to the nearest 0,001 g with an analytical balance (6.9). The following tasks shall be performed:

  • Pipette 100 ml (V ) of degassed solution (5.1) into a 250 ml conical flask (6.2). Displace oxygen

by passing oxygen-free argon (or nitrogen) (5.6) into the flask for 5 min with a volume flow of (50 ± 10) ml/min. Remove the aeration tube (6.3), add the sample and close the flask with a stopper. Record the extract volume as V (100 ml + sample volume in ml).

...