SIST EN 837-1:1997/AC:2001
(Main)Pressure gauges - Part 1: Bourdon tube pressure gauges - Dimensions, metrology, requirements and testing
Pressure gauges - Part 1: Bourdon tube pressure gauges - Dimensions, metrology, requirements and testing
TC - Mistake
Druckmeßgeräte - Teil 1: Druckmeßgeräte mit Rohrfedern -Maße, Meßtechnik, Anforderungen und Prüfung
Manometres - Partie 1: Manometres a tubes de Bourdon - Dimensions, métrologie, prescriptions et essais
Merilniki tlaka - 1. del: Merilniki tlaka z Bourdonovo cevjo - Mere, meroslovje, zahteve in preskušanje
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Merilniki tlaka - 1. del: Merilniki tlaka z Bourdonovo cevjo - Mere, meroslovje, zahteve in preskušanjeDruckmeßgeräte - Teil 1: Druckmeßgeräte mit Rohrfedern -Maße, Meßtechnik, Anforderungen und PrüfungManometres - Partie 1: Manometres a tubes de Bourdon - Dimensions, métrologie, prescriptions et essaisPr
...
This May Also Interest You
This part of prEN 837 only applies to those pressure gauges whose pressure responsive element measuring system is a metal part which deforms under the effect of the pressure measured, as defined in prEN 837-1 and EN 837-3. This standard has been prepared to assist in the selection, installation and use of pressure gauges to ensure that they give satisfactory service for the intended application with the maximum level of safety.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day
This European standard specifies requirements for Bourdon tube (designated by B, see clause 12) indicating pressure gauges, vacuum gauges and combined vacuum and pressure gauges (compound gauges), with circular, spiral or coiled forms, from 40 to 250 nominal size with ranges up to 1600 bar for the measurement of gauge pressure. A reading of zero bar is atmospheric pressure.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies requirements for diaphragm and capsule (designated by D and C respectively, see clause 12) indicating pressure gauges, vacuum gauges and combined vacuum and pressure gauges (compound gauges), from 50 to 250 nominal size with ranges up to 25 bar for the measurement of gauge pressure. A reading of zero bar is atmospheric pressure.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard defines the fundamental and general terms to be used for pressure gauges.
- Standard10 pagesEnglish languagesale 10% offe-Library read for×1 day
1.1 This standard specifies the requirements for installation, calibration, performance and accuracy assessment, and test methods for Weigh-in-Motion (WIM) systems, that are used to determine gross weights, axle and group-of-axle loads for road vehicles when they are weighed in motion.
1.2 This standard applies to:
1.2.1 WIM systems installed on road infrastructure (including bridges), but not to the WIM systems installed on-board of vehicles;
1.2.2 High speed WIM (HS-WIM) systems, i.e. systems installed in one or more traffic lane(s) of a road, and operated automatically under normal traffic conditions, and to low speed WIM (LS-WIM) systems, i.e. systems installed in a controlled weighing area, and operated under controlled conditions;
1.2.3 WIM systems using either scales which are able to weigh standard masses statically, or other sensors which may measure the loads indirectly;
1.2.4 on-site full WIM system performance assessment and model (type) approval, but excludes laboratory (product) tests or tests on parts of systems (e.g. sensors only).
1.6 The scope of this standard covers all WIM applications, except trade.
NOTE For load enforcement of road vehicles, this standard or the OIML (International Organization for Legal Metrology) international recommendation R 134-1 and 134-2 (OIML, 2004 and 2006) applies, depending on the national requirements and legislation.
1.7 WIM systems used for trade are dealt with in the OIML recommendations R134-1 and R134-2 (OIML, 2006 and 2004). These OIML recommendations apply to WIM systems installed in controlled weighing areas, on a specified apron and where the vehicle speed is controlled. They mainly apply to WIM systems composed of scales, which are capable of weighing standard masses statically. The OIML recommendations are limited to the highest accuracy classes (0,2 to 10), with tolerances for 100 % of the measurements.
This standard applies to any WIM system, which may be installed either in a controlled weighing area, or on a road open to traffic. These systems may use road sensors and bridge WIM.
This standard covers type approval testing, initial and in service testing.
This standard specifies the required performance and ability of WIM systems in general, but does not aim to standardize products.
- Draft74 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a method for the determination of the vapour pressure, exerted in vacuo, by volatile, low viscosity petroleum products, components, ethanol blends up to 85 % (V/V), and feedstocks using a variable volume chamber. A dry vapour pressure equivalent (DVPE) is calculated from the vapour pressure.
The conditions used in the test described in this document are a vapour-to-liquid ratio of 4:1 and a test temperature of 37,8 °C.
The equipment is not wetted with water during the test, and the method described is therefore suitable for testing samples with or without oxygenates; no account is taken of dissolved water in the sample.
This procedure calculates the partial pressure of the air dissolved in the test portion during the triple expansion process. It is suitable for samples with a DVPE between 15,7 kPa and 97,6 kPa; vapour pressures outside this range can be measured but the precision has not been determined.
This document is applicable to fuels containing oxygenated compounds up to the limits stated in the relevant Council Directive 85/536/EEC [6], and for ethanol-fuel blends up to 85 % (V/V) ethanol.
NOTE For the purposes of this document, the terms “% (m/m)” and “% (V/V)” are used to represent the mass and volume fractions respectively.
WARNING — The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this document to take appropriate measures to ensure the safety and health of personnel prior to application of the standard, and to determine the applicability of any further restrictions for this purpose.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a method for the determination of the air saturated vapour pressure (ASVP) (total vapour pressure), exerted in vacuo, by volatile, low viscosity petroleum products, components, ethanol blends up to 85 % (V/V), and feedstocks containing air. A dry vapour pressure equivalent (DVPE) can be calculated from the air containing vapour pressure (ASVP) measurement.
The conditions used in the test described in this document are a vapour-to-liquid ratio of 4:1 and a test temperature of 37,8 °C.
The equipment is not wetted with water during the test, and the method described is therefore suitable for testing samples with or without oxygenates; no account is taken of dissolved water in the sample.
The method described is suitable for testing air saturated samples with a DVPE between 15,5 kPa and 106,0 kPa; vapour pressures outside this range can be measured, but the precision has not been determined.
This document is applicable to fuels containing oxygenated compounds up to the limits stated in the relevant Council Directive 85/536/EEC [10], and for ethanol-fuel blends up to 85 % (V/V) ethanol.
NOTE For the purposes of this document, the terms “% (m/m)” and “% (V/V)” are used to represent the mass and volume fractions, respectively.
WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this document to take appropriate measures to ensure the safety and health of personnel prior to application of the document, and to determine the applicability of any other restrictions for this purpose.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the measurement of pore water pressures and piezometric levels in saturated ground by means of piezometers installed for geotechnical monitoring. General rules of performance monitoring of the ground, of structures interacting with the ground, of geotechnical fills and of geotechnical works are presented in ISO 18674‑1.
If applied in conjunction with ISO 18674-5, the procedures described in this document allow the determination of effective stresses acting in the ground.
This document is applicable to:
— monitoring of water pressures acting on and in geotechnical structures (e.g. quay walls, dikes, excavation walls, foundations, dams, tunnels, slopes, embankments, etc.);
— monitoring of consolidation processes of soil and fill (e.g. beneath foundations and in embankments);
— evaluating stability and serviceability of geotechnical structures;
— checking geotechnical designs in connection with the Observational Design procedure.
NOTE This document fulfils the requirements for the performance monitoring of the ground, of structures interacting with the ground and of geotechnical works by the means of piezometers, installed as part of the geotechnical investigation and testing in accordance with References [4] and [5] This document relates to measuring devices, which are installed in the ground. For pore water pressure measurements carried out in connection with cone penetration tests, see ISO 22476-1.
- Standard65 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements for Bourdon-tube pressure gauges normally used with compressed gas systems at pressures up to 30 MPa (300 bar) in welding, cutting and allied processes. It also covers use for dissolved acetylene and for liquefied gases under pressure.
It does not cover gauges for acetylene in acetylene-manufacturing plants.
- Standard22 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62828-2:2017 establishes specific procedures for testing pressure process measurement transmitters (PMT) used in measuring and control systems for industrial processes and for machinery control systems. A pressure PMT can feature a remote seal to bring the process variable to the sensing element in the PMT. When the remote seal cannot be separated from the PMT, the complete device is tested.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...