Abstract

Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. NOTE - Testing to EN 60332-1-3 may be performed simultaneously with that to EN 60332-1-2, if required. Recommended requirements for performance are given in Annex A. EN 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. Has the status of a group safety publication in accordance with IEC Guide 104.

Status
Published
Publication Date
28-Feb-2005
Technical Committee
IEKA - Electric cables
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-2005
Due Date
01-Mar-2005
Completion Date
01-Mar-2005

Buy Documents

Standard

SIST EN 60332-1-3:2005

English language (14 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 60332-1-3:2005 is a Slovenian standard published by SIST that adopts EN 60332-1-3 for tests on electric and optical fibre cables under fire conditions. It specifies a procedure for checking whether a single insulated wire or cable, or an optical fibre cable, produces falling flaming droplets or particles when exposed to a defined vertical flame. The document is used when a repeatable, comparative fire-behaviour test is needed for cable products.

What does SIST EN 60332-1-3:2005 specify?

SIST EN 60332-1-3:2005 specifies a test procedure for assessing flaming droplets or particles from a single vertical insulated conductor or cable, or an optical fibre cable, under defined fire conditions. It is written for general use with a 1 kW pre-mixed flame, and the document notes that the method may be impractical for very small insulated conductors or cables below 0.5 mm² total cross-section and for small optical fibre cables that can fail before the test is complete.

The document is organized into:

  • Scope
  • Normative references
  • Terms and definitions
  • Test apparatus
  • Procedure
  • Evaluation of test results
  • Annex A with recommended performance requirements
  • Annex ZA with normative references to European publications
AnnexWhat it covers
Annex ARecommended performance requirements for pass/fail assessment
Annex ZANormative references and their corresponding European publications

What are the key requirements of SIST EN 60332-1-3:2005?

SIST EN 60332-1-3:2005 ties the test to a specific apparatus, specimen preparation, flame position, and result recording method so that the presence of flaming debris can be judged consistently.

Apparatus and materials

Clause 4 requires the apparatus from IEC 60332-1-1, including the ignition source in that part. It also specifies undyed cellulose filter paper with controlled density and low ash content, conditioned according to ISO 187. In practice, this means the setup is fixed enough that different laboratories can compare results without changing the basic test arrangement.

Specimen preparation

Clause 5.1 uses a test piece 600 mm long. Clause 5.2 requires conditioning at controlled temperature and humidity before testing, with an added heat exposure step for insulated conductors or cables finished with paint or lacquer. This matters because moisture and surface finishes can influence how the specimen behaves in fire.

Mounting and exposure

Clause 5.3 requires the specimen to be mounted vertically in the centre of the metal screen, with filter paper placed beneath it immediately before the test. Clause 5.4 positions the burner at a fixed angle and distance, and the flame is applied for a time that depends on the specimen’s overall diameter. For non-circular cables, circumference is used to calculate an equivalent diameter, so shaped cables are treated in a comparable way.

Result evaluation

Clause 6 records whether the filter paper ignites and, if it does, how long the burning lasts. The practical meaning is straightforward: the test does not just ask whether the cable burns, but whether burning material drops from it and starts secondary ignition below.

Performance guidance

Annex A recommends that a cable passes if the filter paper does not ignite during the test duration. If a failure occurs, two additional tests are run, and both must pass for the cable to be accepted under the recommended criterion.

What terms does SIST EN 60332-1-3:2005 define?

  • Ignition source - the source of energy that starts combustion.
  • Flaming debris - material that falls from the specimen while still flaming and ignites the filter paper beneath it.
  • Test piece - the insulated conductor or cable specimen prepared for the test.
  • Filter paper - the conditioned paper placed under the specimen to detect flaming droplets or particles.
  • Group safety publication - the IEC publication category used for this standard under IEC Guide 104.
  • Pre-mixed flame - the burner flame used by this method, supplied with controlled gas and air.

Who uses SIST EN 60332-1-3:2005?

SIST EN 60332-1-3:2005 is used by cable manufacturers, testing laboratories, and quality or technical staff who need to assess fire behaviour of electric and optical fibre cables. Buyers and specifiers can also use it when they need a documented method for comparing products or checking claimed fire performance. The main task is to run the test, observe flaming droplets or particles, and record whether they ignite the filter paper.

Which standards are used with SIST EN 60332-1-3:2005?

  • IEC 60332-1-1 - provides the apparatus and burner details used for the test.
  • IEC Guide 104 - gives the framework for group safety publications.
  • ISO 187 - supplies the conditioning atmosphere and conditioning procedure for the filter paper and samples.
  • IEC 60332-1-2 - the companion test method that may be run at the same time when needed.

What does the SIST EN 60332-1-3:2005 document contain?

The document contains the test scope, the list of normative references, two defined terms, apparatus requirements, the full test procedure, and the method for evaluating results. It also includes two figures showing specimen arrangement and flame application, plus a table that sets the flame application time by specimen diameter. Annex A gives recommended pass/fail performance guidance, and Annex ZA links the referenced international publications to corresponding European publications.

Relations

Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
22-Jul-2026
Effective Date
10-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026

Buy Documents

Standard

SIST EN 60332-1-3:2005

English language (14 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 60332-1-3:2005 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Tests on electric and optical fibre cables under fire conditions -- Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles". This standard covers: Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. NOTE - Testing to EN 60332-1-3 may be performed simultaneously with that to EN 60332-1-2, if required. Recommended requirements for performance are given in Annex A. EN 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. Has the status of a group safety publication in accordance with IEC Guide 104.

Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. NOTE - Testing to EN 60332-1-3 may be performed simultaneously with that to EN 60332-1-2, if required. Recommended requirements for performance are given in Annex A. EN 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. Has the status of a group safety publication in accordance with IEC Guide 104.

SIST EN 60332-1-3:2005 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.060.20 - Cables; 33.180.10 - Fibres and cables. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60332-1-3:2005 has the following relationships with other standards: It is inter standard links to SIST EN 20187:2000, SIST EN 60332-1-1:2005, SIST EN 12845:2015+A2:2026, SIST EN 13289:2002+A1:2013, SIST EN 12845:2015, SIST EN 13379:2002+A1:2013, SIST EN 12845:2015+A1:2020, SIST EN 13378:2002+A1:2013, SIST EN 12312-4:2014, SIST EN 1710:2006+A1:2008, SIST EN 12312-4:2024, SIST EN IEC 62368-1:2024, SIST EN IEC 62368-1:2020, SIST EN IEC 60709:2019, SIST EN 60709:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60332-1-3:2005 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2010-01-3290, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 60332-1-3:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 ignition source
  • 3.2 flaming debris
  • 4 Test apparatus
  • 4.1 General
  • 4.2 Ignition source
  • 4.3 Filter paper
  • 5 Procedure
  • 5.1 Sample
  • 5.2 Conditioning
  • 5.3 Positioning of test piece and filter paper
  • 5.4 Flame application
  • 6 Evaluation of test results
  • Annex A
  • Bibliography

1 Scope

This part of IEC 60332 specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions.

NOTE 1 Testing to IEC 60332-1-3 may be performed simultaneously with that to IEC 60332-1-2, if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors

or cables of less than 0,5 mm total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60332-1-1, Tests on electric and optical fibre cables under fire conditions – Part 1-1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus IEC Guide 104, The preparation of safety publications and the use of basic safety publications and group safety publications ISO 187, Paper, board and pulps – Standard atmosphere for conditioning and testing and procedure for monitoring the atmosphere and conditioning of samples

3 Terms and definitions

For the purposes of this document, the following terms and definitions, apply. Some definitions are taken from IEC 60695-4.

3.1 ignition source

source of energy that initiates combustion [IEC 60695-4:1993, definition 2.76]

3.2 flaming debris

matter flowing or separating from the specimen during the test procedure and falling below the initial lower edge of the specimen, continuing to flame as it falls, and igniting the filter paper beneath

4 Test apparatus

4.1 General

The apparatus specified in IEC 60332-1-1 shall be used.

4.2 Ignition source

The ignition source shall comply with 4.3 of IEC 60332-1-1.

...