SIST CR 13839:2000
(Main)Petroleum products - Determination of aromaticity - 13C nuclear magnetic resonance (NMR) spectrometric method
Petroleum products - Determination of aromaticity - 13C nuclear magnetic resonance (NMR) spectrometric method
This CEN Report describes a method of test which can be used for the determination of the aromaticity of petroleum products. The method described is applicable to all hydrocarbon mixtures that are completely soluble in chloroform, including kerosines, middle distillates, gas oils, coal liquids and other distillate mineral oil fractions, and is not restricted to a particular boiling range. The lower detection limit for aromaticity by the method is typically in the region of 0,5 %.
Naftni proizvodi - Določevanje aromatičnosti - Spektrometrijska metoda 13C z nuklearno magnetno resonanco (NMR)
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Petroleum products - Determination of aromaticity - 13C nuclear magnetic resonance (NMR) spectrometric method75.080Naftni proizvodi na splošnoPetroleum products in generalICS:Ta slo
...
This May Also Interest You
This document specifies a method for the separation of fatty acid methyl esters (FAME) from middle distillates by liquid chromatography (LC) and for the determination of the pattern of the fatty acid methyl esters by gas chromatography (GC) according to EN 14103.
This document is applicable for the determination of the pattern of the fatty acid methyl esters for the calculation of the average molecular mass of FAME according to EN 14078 [1].
Independently from the origin of the middle distillate, this method is applicable to FAME of vegetable or animal origin that contain fatty acid methyl esters between C6:0 and C24:1. The method is suitable for the separation and determination of FAME from middle distillates with FAME contents of at least 2 % (V/V).
NOTE For the purpose of this document, the terms % (V/V) and % (m/m) are used to express volume fractions in % or mass fractions in %.
- Standard9 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the manual methods used for obtaining samples of liquid or semi-liquid hydrocarbons, tank residues and deposits from fixed tanks, railcars, road vehicles, ships and barges, drums and cans, or from liquids being pumped in pipelines.
It applies to the sampling of liquid products, including crude oils, intermediate products, synthetic hydrocarbons and bio fuels, which are stored at or near atmospheric pressure, or transferred by pipelines as liquids at elevated pressures and temperatures.
The sampling procedures specified are not intended for the sampling of special petroleum products which are the subject of other International Standards, such as electrical insulating oils (covered in IEC 60475), liquefied petroleum gases (covered in ISO 4257), liquefied natural gases (covered in ISO 8943) and gaseous natural gases (covered in ISO 10715).
This document refers to methods of sampling and sampling equipment in use at the time of writing. It does not exclude the use of new equipment, provided that such equipment enables samples to be obtained according to the requirements and procedures of this document.
- Standard79 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a method to identify and compare the compositional characteristics of oil samples. Specifically, it describes the detailed analytical and data processing methods for identifying the characteristics of spill samples and establishing their correlation to suspected source oils. Even when samples or data from suspected sources are not available for comparison, establishing the specific nature (e.g. refined petroleum, crude oil, waste oil, etc.) of the spilled oil still helps to constrain the possible source(s).
This methodology is restricted to petroleum related products containing a significant proportion of hydrocarbon-components with a boiling point above 150 °C. Examples are: crude oils, higher boiling condensates, diesel oils, residual bunker or heavy fuel oils, lubricants, and mixtures of bilge and sludge samples, as well as distillate fuels and blends. While the specific analytical methods are perhaps not appropriate for lower boiling oils (e.g. kerosene, jet fuel, or gasoline), the general concepts described in this methodology, i.e. statistical comparison of weathering-resistant diagnostic ratios, are applicable in spills involving these kinds of oils.
Paraffin based products (e.g. waxes, etc.) are outside the scope of this method because too many compounds are removed during the production process [37]. However, the method can be used to identify the type of product involved.
Although not directly intended for identifying oil recovered from groundwater, vegetation, wildlife/tissues, soil, or sediment matrices, they are not precluded. However, caution is needed as extractable compounds can be present in these matrices that alter and/or contribute additional compounds compared to the source sample. If unrecognized, the contribution from the matrix can lead to false “non-matches”. It is therefore advisable to analyse background sample(s) of the matrix that appear unoiled.
When analysing “non-oil” matrices additional sample preparation (e.g. clean-up) is often required prior to analysis and the extent to which the matrix affects the correlation achieved is to be considered. Whether the method is applicable for a specific matrix depends upon the oil concentration compared to the “matrix concentration”. In matrices containing high concentrations of oil, a positive match can still be concluded. In matrices containing lower concentrations of oil, a false “non-match” or an “inconclusive match” can result from matrix effects. Evaluation of possible matrix effects is beyond the scope of this document.
- Standard218 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline, small engine petrol and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined.
Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a fluorescent indicator adsorption method for the determination of hydrocarbon types over the concentration ranges from 5 % (V/V) to 99 % (V/V) aromatic hydrocarbons, 0,3 % (V/V) to 55 % (V/V) olefins, and 1 % (V/V) to 95 % (V/V) saturated hydrocarbons in petroleum fractions that distil below 315 °C. This method can apply to concentrations outside these ranges, but the precision has not been determined.
When samples containing oxygenated blending components are analysed, the hydrocarbon type results can be reported on an oxygenate-free basis or, when the oxygenate content is known, the results can be corrected to a total-sample basis.
This test method is applicable to full boiling range products. Cooperative data have established that the precision statement does not apply to petroleum fractions with narrow boiling ranges near the 315 °C limit. Such samples are not eluted properly, and results are erratic.
It does not apply to samples containing dark-coloured components that interfere with reading the chromatographic bands that cannot be analysed.
NOTE 1 The oxygenated blending components methanol, ethanol, tert-butyl methyl ether (MTBE), methyl tert-pentyl ether (TAME) and tert-butyl ethyl ether (ETBE) do not interfere with the determination of hydrocarbon types at concentrations normally found in commercial petroleum blends. These oxygenated compounds are not detected since they elute with the alcohol desorbent. The effects of other oxygenated compounds are individually verified.
NOTE 2 For the purposes of this document, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction and the volume fraction.
WARNING — The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a procedure for the determination of kinematic viscosity, ν, by calculation from dynamic viscosity, η, and density, ρ, of both transparent and opaque liquid petroleum products and crude oils using the Stabinger type viscometer.
The result obtained using the procedure described in this document depends on the rheological behaviour of the sample. This document is predominantly applicable to liquids whose shear stress and shear rate are proportional (Newtonian flow behaviour). If the viscosity changes significantly with the shear rate, comparison with other measuring methods is not possible except at similar shear rates.
The precision has been determined only for the materials, density ranges and temperatures described in Clause 13. The test method can be applied to a wider range of viscosity, density, temperature and materials. It is possible that the precision and bias are applicable for materials which are not listed in Clause 13.
- Standard25 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3, which can be handled as single-phase liquids at the test temperature and pressure.
This document is applicable to liquids of any vapour pressure as long as suitable precautions are taken to ensure that they remain in single phase. Loss of light components leads to changes in density during both the sample handling and the density determination.
This method is not intended for use with in-line density meters.
- Standard19 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of the content of mono-aromatic, di aromatic and tri+-aromatic hydrocarbons in diesel fuels, paraffinic diesel fuels and petroleum distillates.
This document specifies two procedures, A and B.
Procedure A is applicable to diesel fuels that may contain fatty acid methyl esters (FAME) up to 30 % (V/V) (as in [1], [2] or [3]) and petroleum distillates in the boiling range from 150 °C to 400 °C (as in [4].
Procedure B is applicable to paraffinic diesel fuels with up to 7 % (V/V) FAME. This procedure does not contain a dilution of the sample in order to determine the low levels of aromatic components in these fuels.
The polycyclic aromatic hydrocarbons content is calculated from the sum of di-aromatic and tri+-aromatic hydrocarbons and the total content of aromatic compounds is calculated from the sum of the individual aromatic hydrocarbon types.
Compounds containing sulfur, nitrogen and oxygen can interfere in the determination; mono-alkenes do not interfere, but conjugated di-alkenes and poly-alkenes, if present, can do so. The measurement ranges that apply to this method are given in Table 2 and Table 3.
NOTE 1 For the purpose of this document, the terms "% (m/m)" and "% (V/V)" are used to represent the mass fraction, µ, and the volume fraction, φ, of a material respectively.
NOTE 2 By convention, the aromatic hydrocarbon types are defined on the basis of their elution characteristics from the specified liquid chromatography column relative to model aromatic compounds. Their quantification is performed using an external calibration with a single aromatic compound for each of them, which may or may not be representative of the aromatics present in the sample. Alternative techniques and test methods may classify and quantify individual aromatic hydrocarbon types differently.
NOTE 3 Backflush is part of laboratory-internal maintenance.
WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this document to take appropriate measures to ensure the safety and health of personnel prior to application of the standard, and fulfil statutory and regulatory requirements for this purpose.
- Standard23 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a procedure for determining dynamic viscosity, η, and density, ρ, for the calculation of kinematic viscosity, ν, of middle distillate fuels, fatty acid methyl ester fuels (FAME) and mixtures thereof, up to 60 % with middle distillate fuels, and lubricating oils (e.g. base oils, formulated oils), and synthetics, using a constant pressure viscometer. The range of kinematic viscosities covered in this test method is from 0,5 mm2/s to 2 000 mm2/s, with precision at 40 °C from 1,0 mm2/s to 1 286 mm2/s, and precision at 100 °C from 3,0 mm2/s to 157 mm2/s.
The result obtained using the procedure described in this document depends on the rheological behaviour of the sample. This document is predominantly applicable to liquids whose shear stress and shear rate are proportional (Newtonian flow behaviour). However, if the viscosity changes significantly with the shear rate, comparison with other measuring methods is only permissible at similar shear rates.
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies statistical methodology for assessing the expected agreement between two test methods that purport to measure the same property of a material, and for deciding if a simple linear bias correction can further improve the expected agreement.
This document is applicable for analytical methods which measure quantitative properties of petroleum or petroleum products resulting from a multi-sample-multi-lab study (MSMLS). These types of studies include but are not limited to interlaboratory studies (ILS) meeting the requirements of ISO 4259-1 or equivalent, and proficiency testing programmes (PTP) meeting the requirements of ISO 4259-3 or equivalent.
The methodology specified in this document establishes the limiting value for the difference between two results where each result is obtained by a different operator using different apparatus and two methods X and Y, respectively, on identical material. One of the methods (X or Y) has been appropriately bias-corrected to agree with the other in accordance with this practice. This limit is designated as the between-methods reproducibility. This value is expected to be exceeded with a probability of 5 % under the correct and normal operation of both test methods due to random variation.
NOTE Further conditions for application of this methodology are given in 5.1 and 5.2.
- Standard56 pagesEnglish languagesale 10% offe-Library read for×1 day
- 02-Jan-2023
- 01-Feb-2024
- 75.080
- 75.180.20
- 2011-01-3239