SIST EN 61076-3-115:2010
Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type (IEC 61076-3-115:2009)
Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type (IEC 61076-3-115:2009)
IEC 61076-3-115:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-115: Rechteckige Steckverbinder - Bauartspezifikation für Schutzgehäuse für die Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600 MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 - Ausführung 12 zu IEC 61076-3-106 - Push-pull-Ausführung (IEC 61076-3-115:2009)
Connecteurs pour équipement électroniques - Exigences de produit - Partie 3-115: Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés avec des connecteurs blindés et non blindés à 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des environnements industriels incorporant l’interface série CEI 60603-7 - Variante 12 liée à la CEI 61076-3-106 - Type d’accouplement pousser-tirer (CEI 61076-3-115:2009)
La CEI 61076-3-115:2009 couvre les boîtiers de protection pour améliorer les connecteurs à 8 voies blindés et non blindés existants utilisant l'interface décrite dans la CEI 60603-7-2, la CEI 60603-7-3, la CEI 60603-7-4, la CEI 60603-7-5 et la CEI 60603-7-7 pour les caractéristiques IP65 et IP67 conformément à la CEI 60529, utilisés dans les environnements industriels. Les boîtiers couvrent différents mécanismes de verrouillage conformes à la présente norme et une variété de configurations de montage et de types de sortie qui sont détaillés dans la CEI 60603-7.
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-115. del: Pravokotni konektorji - Zaščitna ohišja za 8-redne zaslonjene in nezaslonjene konektorje za frekvence do 600 MHz za industrijska okolja z vgrajenim vmesnikom serije IEC 60603-7 - Različica 12 glede na 61076-3-106 - Zaklepni tip (IEC 61076-3-115:2009)
Ta del IEC 61076 zajema zaščitna ohišja za nadgradnjo obstoječih 8-redno zaslonjenih in nezaslonjenih konektorjev, ki uporabljajo vmesnik, opisan v IEC 60603-7-2, IEC 60603-7-4, IEC 60603-7-5 in IEC 60603-7-7 do ocen IP65 in IP67, glede na IEC 60529, za uporabo v industrijskih okoljih. Glede na ta standard ohišja pokrivajo zbirko različnih mehanizmov za zaklepanje in zbirko različnih konfiguracij za postavitev in vrste priključkov, ki so podrobno opisani v IEC 60603-7. Splošne konfiguracije paritev za vse različice so določene v IEC 60603-7. Mere paritev za ohišja pod členom 3 dopuščajo izpolnitev pogojev paritev v skladu z IEC 60603-7. Polno sestavljene različice (konektorji), opisane v tem standardu, vključujejo fiksne in proste konektorje, ki so popolnoma v skladu z IEC 60603-7.
General Information
- Status
- Published
- Publication Date
- 19-Oct-2010
- Technical Committee
- I11 - Imaginarni 11
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 04-Oct-2010
- Due Date
- 09-Dec-2010
- Completion Date
- 20-Oct-2010
Overview
EN 61076-3-115:2010 (identical to IEC 61076-3-115:2009) specifies detail requirements for protective housings used with 8‑way shielded and unshielded rectangular connectors (IEC 60603-7 series interface) for industrial environments. The standard targets housings that upgrade existing connectors to IP65/IP67 degrees of protection (per IEC 60529) and covers Variant 12 - push‑pull coupling related to IEC 61076-3-106 for frequencies up to 600 MHz.
Key topics and technical requirements
- Scope & purpose: protective housings for 8‑way connectors (shielded/unshielded) to achieve robust environmental sealing in industrial applications.
- Interface compatibility: incorporates the IEC 60603-7 series interfaces (parts 7-2, 7-3, 7-4, 7-5, 7-7) and Variant 12 push‑pull coupling.
- Protection ratings: requirements and testing to attain IP65 and IP67 in-service ratings (IEC 60529).
- Mechanical & dimensional data: detailed drawings, dimensions and mounting configurations for fixed and free connectors, including caps.
- Termination & mounting: permissible mounting configurations and termination types referenced to IEC 60603-7 detail specifications.
- Electrical & transmission: transmission characteristics up to 600 MHz, clearance/creepage, insulation and voltage-proof considerations.
- Durability & performance tests: climatic category, environmental tests (temperature change, damp heat), mechanical endurance, mating cycles, contact resistance and dynamic stress tests - organized into test groups (P, AP, BP, CP, DP, EP).
- Product features: variety of locking mechanisms, push‑pull coupling effectiveness, engagement/separation forces and current derating considerations.
- Supporting references: normative cross‑references such as IEC 60512 (tests), IEC 60068 (environmental testing), IEC 60664-1 (insulation coordination), IEC 61076-1 (generic connector requirements).
Applications and users
Who benefits from EN 61076-3-115:
- Connector manufacturers designing protective housings for industrial connectors.
- OEMs and system integrators specifying sealed connector solutions for automation, industrial Ethernet, fieldbus, sensors/actuators, robotics and machine tools.
- Product certification and compliance teams validating IP65/IP67 upgrades.
- Design and maintenance engineers upgrading existing 8‑way installations for harsher environments without changing the connector interface.
Practical uses:
- Converting indoor connector assemblies to IP‑rated field connectors.
- Standardizing push‑pull sealed connections for frequent mating cycles in industrial equipment.
- Ensuring compliant mechanical, electrical and climatic performance for 8‑way connector housings.
Related standards
- IEC/EN 60603-7 series (8‑way connector detail specifications)
- IEC 60529 (IP Code)
- IEC 60512 (connector tests and measurements)
- IEC 60068 (environmental testing)
- IEC 60664-1, IEC 61076-1 and IEC 61156 series
Keywords: EN 61076-3-115:2010, IEC 61076-3-115, protective housings, 8‑way rectangular connectors, IP65, IP67, push‑pull, IEC 60603-7, industrial connectors, shielded/unshielded, up to 600 MHz.
Frequently Asked Questions
SIST EN 61076-3-115:2010 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type (IEC 61076-3-115:2009)". This standard covers: IEC 61076-3-115:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
IEC 61076-3-115:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
SIST EN 61076-3-115:2010 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61076-3-115:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2010
.RQHNWRUML]DHOHNWURQVNRRSUHPR=DKWHYH]DL]GHOHNGHO3UDYRNRWQL
NRQHNWRUML=DãþLWQDRKLãMD]DUHGQH]DVORQMHQHLQQH]DVORQMHQHNRQHNWRUMH]D
IUHNYHQFHGR0+]]DLQGXVWULMVNDRNROMD]YJUDMHQLPYPHVQLNRPVHULMH,(&
5D]OLþLFDJOHGHQD=DNOHSQLWLS,(&
Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular
connectors - Detail specification for protective housings for use with 8-way shielded and
unshielded connectors for frequencies up to 600 MHz for industrial environments
incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 -
Push-pull type (IEC 61076-3-115:2009)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-115:
Rechteckige Steckverbinder - Bauartspezifikation für Schutzgehäuse für die Anwendung
mit 8-poligen geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600
MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7
- Ausführung 12 zu IEC 61076-3-106 - Push-pull-Ausführung (IEC 61076-3-115:2009)
Connecteurs pour équipement électroniques - Exigences de produit - Partie 3-115:
Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés
avec des connecteurs blindés et non blindés à 8 voies pour des fréquences inférieures
ou égales à 600 MHz dans des environnements industriels incorporant l’interface série
CEI 60603-7 - Variante 12 liée à la CEI 61076-3-106 - Type d’accouplement pousser-
tirer (CEI 61076-3-115:2009)
Ta slovenski standard je istoveten z: EN 61076-3-115:2010
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61076-3-115
NORME EUROPÉENNE
September 2010
EUROPÄISCHE NORM
ICS 31.220.10
English version
Connectors for electronic equipment - Product requirements -
Part 3-115: Rectangular connectors -
Detail specification for protective housings for use with 8-way shielded and
unshielded connectors for frequencies up to 600 MHz for industrial environments
incorporating the IEC 60603-7 series interface -
Variant 12 related to IEC 61076-3-106 -
Push-pull type
(IEC 61076-3-115:2009)
Connecteurs pour équipement électroniques - Steckverbinder für elektronische Einrichtungen -
Exigences de produit - Produktanforderungen -
Partie 3-115: Connecteurs rectangulaires - Teil 3-115: Rechteckige Steckverbinder -
Spécification particulière pour boîtiers de Bauartspezifikation für Schutzgehäuse für die
protection utilisés avec des connecteurs blindés et Anwendung mit 8-poligen geschirmten und
non blindés à 8 voies pour des fréquences ungeschirmten Steckverbindern für Frequenzen bis
inférieures ou égales à 600 MHz dans des 600 MHz für industrielle Umgebungen zur Aufnahme
environnements industriels incorporant l’interface der Schnittstelle der Reihe IEC 60603-7 -
série CEI 60603-7 - Ausführung 12 zu IEC 61076-3-106 -
Variante 12 liée à la CEI 61076-3-106 - Push-pull-Ausführung
Type d’accouplement pousser-tirer (IEC 61076-3-115:2009)
(CEI 61076-3-115:2009)
This European Standard was approved by CENELEC on 2010-09-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61076-3-115:2010 E
Foreword
The text of document 48B/2011/FDIS, future edition 1 of IEC 61076-3-115, prepared by SC 48B,
Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic
equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 61076-3-115 on 2010-09-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-06-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2013-09-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61076-3-115:2009 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 61076-3-115:2010
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60050-581 2008 International Electrotechnical Vocabulary - - -
Part 581: Electromechanical components for
electronic equipment
IEC 60068-1 - Environmental testing - EN 60068-1 -
Part 1: General and guidance
IEC 60068-2-14 - Environmental testing - EN 60068-2-14 -
Part 2-14: Tests - Test N: Change of
temperature
IEC 60068-2-30 - Environmental testing - EN 60068-2-30 -
Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)
IEC 60512-1 - Connectors for electronic equipment - Tests EN 60512-1 -
and measurements -
Part 1: General
IEC 60512-1-100 - Connectors for electronic equipment - Tests EN 60512-1-100 -
and measurements -
Part 1-100: General - Applicable publications
IEC 60529 - Degrees of protection provided by enclosures EN 60529 -
(IP Code)
IEC 60603-7 - Connectors for electronic equipment - EN 60603-7 -
Part 7: Detail specification for 8-way,
unshielded, free and fixed connectors
IEC 60603-7-2 - Connectors for electronic equipment - EN 60603-7-2 -
Part 7-2: Detail specification for 8-way,
unshielded, free and fixed connectors, for data
transmissions with frequencies up to 100 MHz
IEC 60603-7-3 - Connectors for electronic equipment - EN 60603-7-3 -
Part 7-3: Detail specification for 8-way,
shielded, free and fixed connectors, for data
transmission with frequencies up to 100 MHz
IEC 60603-7-4 - Connectors for electronic equipment - EN 60603-7-4 -
Part 7-4: Detail specification for 8-way,
unshielded, free and fixed connectors, for data
transmissions with frequencies up to 250 MHz
Publication Year Title EN/HD Year
IEC 60603-7-5 - Connectors for electronic equipment - EN 60603-7-5 -
Part 7-5: Detail specification for 8-way,
shielded, free and fixed connectors, for data
transmissions with frequencies up to 250 MHz
IEC 60603-7-7 - Connectors for electronic equipment - EN 60603-7-7 -
Part 7-7: Detail specification for 8-way,
shielded, free and fixed connectors for data
transmission with frequencies up to 600 MHz
IEC 60664-1 - Insulation coordination for equipment within EN 60664-1 -
low-voltage systems -
Part 1: Principles, requirements and tests
IEC 61076-1 2006 Connectors for electronic equipment - EN 61076-1 2006
Product requirements -
Part 1: Generic specification
IEC 61156 Series Multicore and symmetrical pair/quad cables - -
for digital communications
IEC 61156-2 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 2: Horizontal floor wiring - Sectional
specification
IEC 61156-3 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 3: Work area cable - Sectional
specification
IEC 61156-4 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 4: Riser cables - Sectional specification
IEC 61076-3-115 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 3-115: Rectangular connectors – Detail specification for protective housings
for use with 8-way shielded and unshielded connectors for frequencies up to
600 MHz for industrial environments incorporating the IEC 60603-7 series
interface – Variant 12 related to IEC 61076-3-106 – Push-pull type
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 3-115: Connecteurs rectangulaires – Spécification particulière pour
boîtiers de protection utilisés avec des connecteurs blindés et non blindés à
8 voies pour des fréquences inférieures ou égales à 600 MHz dans des
environnements industriels incorporant l’interface série CEI 60603-7 – Variante
12 liée à la CEI 61076-3-106 – Type d’accouplement pousser-tirer
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
T
CODE PRIX
ICS 31.220.10 ISBN 2-8318-1046-5
– 2 – 61076-3-115 © IEC:2009
CONTENTS
FOREWORD.4
INTRODUCTION.6
1 General data .7
1.1 Scope and object.7
1.2 Normative references .7
2 Terms and definitions .8
3 Dimensional information .8
3.1 Common features .8
3.2 General .9
3.3 Contact arrangement of all connector types.9
3.4 IP65 and IP67 sealing .9
3.5 Industrial IEC 60603-7 variant 12 – Push-pull coupling.9
3.5.1 Industrial IEC 60603-7 variant 12, fixed connectors .9
3.5.2 Industrial IEC 60603-7 variant 12, free connectors .12
3.6 Termination and mounting information.13
3.6.1 General .13
3.6.2 Mounting information for variant 12, fixed connector.13
3.7 Cap for fixed connector .14
3.8 Cap for free connector.15
4 Gauges .16
4.1 Connectors, IEC 60603-7 interface.16
5 Characteristics .16
5.1 Climatic category.16
5.2 Electrical .16
5.2.1 Clearance and creepage distances.16
5.2.2 Voltage proof.17
5.2.3 Current derating diagram.17
5.2.4 Mating cycles with power applied.17
5.2.5 Initial contact resistance .18
5.2.6 Input-to-output resistance.18
5.2.7 Resistance unbalance .18
5.2.8 Initial insulation resistance .18
5.3 Transmission characteristics .18
5.3.1 General .18
5.3.2 Mechanical operation .18
5.3.3 Effectiveness of connector coupling devices, transversal.18
5.3.4 Effectiveness of connector coupling devices.19
5.3.5 Separation and engagement forces .19
6 Test schedule.19
6.1 General .19
6.2 Test procedures and measuring methods .19
6.3 Preconditioning .19
6.4 Wiring and mounting of specimens .19
6.4.1 Wiring.19
6.4.2 Mounting .20
6.5 Arrangement for contact resistance test .20
61076-3-115 © IEC:2009 – 3 –
6.6 Arrangement for dynamic stress tests (test phase AP2).20
6.7 Basic (minimum) test schedule .20
6.8 Full test schedule .20
6.8.1 Test preliminary group P.20
6.8.2 Test group P.21
6.8.3 Test group AP .22
6.8.4 Test group BP .23
6.8.5 Test group CP .24
6.8.6 Test group DP .25
6.8.7 Test group EP .25
Figure 1 – Dimensions of fixed connector, variant 12 .10
Figure 2 – Variant 12, free connector.12
Figure 3 – Variant 12 mounting .13
Figure 4 – Variant 12 cap for fixed connector.14
Figure 5 – Variant 12 cap for free connector .15
Figure 6 – Connector derating diagram .17
Table 1 – Dimensions of fixed connector, variant 12 .11
Table 2 – Dimensions of free connector, variant 12.12
Table 3 – Mounting information.13
Table 4 – Dimensions of cap for fixed connector, variant 12 .14
Table 5 – Dimensions of cap for free connector, variant 12.15
Table 6 – Climatic categories – Selected values for environmental performance level A .16
Table 7 – Creepage and clearance distances.16
Table 8 – Test group P .21
Table 9 – Test group AP – Dynamic/climatic .22
Table 10 – Test group BP – Mechanical.23
Table 11 – Test group CP – Continuity.24
– 4 – 61076-3-115 © IEC:2009
INTERNATIONAL ELECTROTECHNICAL COMMISSION
_________________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-115: Rectangular connectors – Detail specification for protective
housings for use with 8-way shielded and unshielded connectors for
frequencies up to 600 MHz for industrial environments incorporating the
IEC 60603-7 series interface – Variant 12 related to
IEC 61076-3-106 – Push-pull type
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national Electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61076-3-115 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
This International Standard cancels and replaces IEC/PAS 61076-3-115 (2005).
The text of this standard is based on the following documents:
FDIS Report on voting
48B/2011/FDIS 48B/2044/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
61076-3-115 © IEC:2009 – 5 –
A list of all parts of IEC 61076 series, under the general title Connectors for electronic
equipment – Product requirements, can be found on the IEC website.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under http://webstore.iec.ch in the
data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 6 – 61076-3-115 © IEC:2009
INTRODUCTION
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. IEC shall not be held responsible for identifying any or all such patent
rights.
The International Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning
1)
Amphenol .
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licences
under reasonable and non-discriminatory terms and conditions with applicants throughout the
world. In this respect, the statement of the holder of this patent right is registered with IEC.
Information may be obtained from:
Amphenol Socapex S.A.S.
948 Promenade de l’Arve
B.P. 29
74311 Thyez Cedex, France
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
—————————
)
Amphenol is the trade name of Amphenol Socapex S.A.S. This information is given for the information of users
of this IS and does not constitute an endorsement by IEC of the trademark holder or any of its products.
Complia
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...