Abstract

This part of European Telecommunication Standard (ETS) 300 119 details requirements for subracks for use in miscellaneous racks/cabinets, as described in ETS 300 119-3 [4]. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc.

Status
Published
Publication Date
31-Jan-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Documents

Standard

SIST ETS 300 119-4 E1:2006

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 119-4 E1:2006 is the Slovenian adoption of ETS 300 119-4 Edition 1 from ETSI. It specifies engineering requirements for subracks used in miscellaneous racks and cabinets for telecommunication equipment in public telecommunications networks. The standard is written for equipment designers, subrack suppliers, and the people who need to check fit, cooling, handling, safety, and EMC-related aspects in practice.

What does SIST ETS 300 119-4 E1:2006 specify?

SIST ETS 300 119-4 E1:2006 sets requirements for subracks used in miscellaneous racks/cabinets as described in ETS 300 119-3. The subrack may be supplied as a fully assembled structure, unequipped, partially equipped, or fully equipped with plug-in units.

The document is organized into scope, normative references, dimensions, accessibility, heat dissipation, weight, temperature limits, and electromagnetic compatibility and electrostatic discharge requirements.

AnnexWhat it covers
Annex AIllustrative figures for the subrack and its interfaces
Annex BThe IEC Sub Committee 48D publication used as the mechanical basis, including noted deviations

What are the key requirements of SIST ETS 300 119-4 E1:2006?

SIST ETS 300 119-4 E1:2006 focuses on fit, cooling, handling, and safety for subracks in telecom equipment systems. In practice, it tells a supplier what has to be designed into the subrack and what information should be available to users and operators.

  • Dimensions, clause 3 - The equipped subrack dimensions must include plug-in units, switches, lamps, cooling fins, connectors, and similar protrusions. This matters because the finished assembly, not just the bare frame, has to fit the rack/cabinet interface defined in Table 1 and Annex A.
  • Accessibility, clause 4 - Subracks for 300 mm deep miscellaneous racks/cabinets need front access only. This supports installation where units are placed back-to-back or against a wall.
  • Heat dissipation, clause 5 - Natural convection is the primary cooling method, and the mechanical design should promote it. Assisted cooling is only for cases where natural convection is not enough, so thermal design work has to start with passive airflow.
  • Temperature control, clause 5 - A fully equipped subrack must not drive components above the limits given by their suppliers across the selected operating ambient range from ETS 300 019. In practice, the supplier needs component temperature data and must be able to show that the design meets it.
  • Thermal planning data, clause 5.3 - On request, the supplier provides the nominal total dissipation of the equipped subrack and other data for rack/cabinet thermal planning. This helps operators size ventilation and avoid overheating at system level.
  • Weight and handling, clause 6 - Unequipped subracks have a maximum weight of 18 kg unless another arrangement is agreed. For equipped subracks, the supplier supplies total weight data so floor loading for telecommunication centres and customer sites can be checked.
  • Touch temperature and EMC, clauses 7 and 8 - Touchable parts must follow the temperature rise limits in EN 60 950, and higher room ambient temperatures require reduced limits. Clause 8 ties the subrack to EMC requirements under Directive 89/336/EEC and the relevant existing and emerging EMC standards.

What terms does SIST ETS 300 119-4 E1:2006 define?

  • Equipment Engineering (EE) - The ETSI technical area covering equipment practice for telecom hardware.
  • European Telecommunications Standards Institute (ETSI) - The organization that produced the ETS.
  • Electromagnetic compatibility (EMC) - The ability of the subrack and its equipment to operate without causing or suffering unacceptable electromagnetic disturbance.
  • Subrack - The assembly that holds plug-in units inside a rack or cabinet.
  • Miscellaneous rack/cabinet - The rack/cabinet type covered by ETS 300 119-3 and used as the installation environment for this part.
  • Coordination dimension - A reference dimension used to coordinate mechanical interfaces; it is not a manufacturing tolerance dimension.
  • Actual dimension - The real made dimension of the part, as opposed to the coordination reference.

Who uses SIST ETS 300 119-4 E1:2006?

SIST ETS 300 119-4 E1:2006 is used by subrack designers, equipment manufacturers, and system integrators who need a common mechanical basis for telecom equipment in public networks. It is also used by suppliers who must provide temperature, dissipation, and weight data to administrations, operators, and customers.

In practice, it helps with product design, mechanical compatibility checks, thermal planning, handling and logistics planning, and safety review for installed equipment.

What changed in SIST ETS 300 119-4 E1:2006 from the previous edition?

SIST ETS 300 119-4 E1:2006 is identified as ETS 300 119-4 Edition 1. The document history notes the first edition in January 1994 and a later conversion into PDF in February 1996.

Which standards are used with SIST ETS 300 119-4 E1:2006?

  • EN 60 950 (1988) - Supplies the safety basis for the temperature rise limits on touchable parts.
  • Council Directive 89/336/EEC - Provides the EMC legal framework referenced in clause 8.
  • ETS 300 019 - Supplies the environmental conditions and test range used for thermal design.
  • ETS 300 119-3 - Defines the miscellaneous racks/cabinets in which these subracks are used.
  • IEC 917-2 - Gives the interface-coordination basis for the 25 mm equipment practice; Annex B notes deviations from it.
  • IEC 917-2-2 - Mentioned in Annex B as the source for tolerances on specific dimensions.

What does the SIST ETS 300 119-4 E1:2006 document contain?

The document includes a dimension framework for subracks, with Table 1 and Annex A figures showing the interface coordinates and relationships between actual and coordination dimensions. It also includes thermal guidance for natural convection, component temperature checks, and thermal planning data that suppliers may need to provide.

It contains handling guidance through the weight limits and the requestable total weight of an equipped subrack. It also includes safety-related touch temperature requirements and a clause linking the design to EMC considerations. Annex B explains the IEC publication used as the basis and where this ETS departs from it.

Buy Documents

Standard

SIST ETS 300 119-4 E1:2006

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 119-4 E1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Equipment Engineering (EE); European telecommunication standard for equipment practice; Part 4: Engineering requirements for subracks in miscellaneous racks and cabinets". This standard covers: This part of European Telecommunication Standard (ETS) 300 119 details requirements for subracks for use in miscellaneous racks/cabinets, as described in ETS 300 119-3 [4]. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc.

This part of European Telecommunication Standard (ETS) 300 119 details requirements for subracks for use in miscellaneous racks/cabinets, as described in ETS 300 119-3 [4]. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc.

SIST ETS 300 119-4 E1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 119-4 E1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Dimensions for subracks
  • 4 Accessibility
  • 5 Heat dissipation
  • 5.1 Subrack heat management
  • 5.2 Component temperature
  • 5.3 Miscellaneous rack/cabinet thermal planning
  • 6 Weight
  • 6.1 Unequipped subrack
  • 6.2 Equipped subrack
  • 7 Temperature limits
  • 8 Electromagnetic compatibility and electrostatic discharge requirements
  • Annex A (informative): Illustrative figures
  • Annex B (informative): IEC Sub Committee 48D publication

1 Scope

This part of European Telecommunication Standard (ETS) 300 119 details requirements for subracks for use in miscellaneous racks/cabinets, as described in ETS 300 119-3 [4]. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc.

2 Normative references

This ETS incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.

[1] EN 60 950 (1988): "Safety of information technology equipment, including electrical business equipment".

[2] Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (EMC):

89/336/EEC.

[3] ETS 300 019: "Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment".

[4] ETS 300 119-3: "Equipment Engineering (EE); European telecommunication standard for equipment practice Part 3: Engineering requirements for miscellaneous racks and cabinets".

3 Dimensions for subracks

The dimensions height H, width W and depth D1 and D2 of the equipped subrack shall include all plug-in units, switches, lamps, cooling fins, connectors, etc.

For a table of dimensions, see table 1 and refer to Annex A, figures A.1 and A.2.

4 Accessibility

Subracks fitting in a miscellaneous rack/cabinet of depth 300 mm shall require access only from the front, so that they can be placed in miscellaneous racks/cabinets which are back to back or against a wall.

5 Heat dissipation

5.1 Subrack heat management

It is a primary requirement for all equipment installed in miscellaneous racks/cabinets to be cooled by natural convection. The mechanical architecture of the subrack shall be designed to promote natural convection.

...