SIST EN ISO 2592:2017
(Main)Petroleum and related products - Determination of flash and fire points - Cleveland open cup method (ISO 2592:2017)
Petroleum and related products - Determination of flash and fire points - Cleveland open cup method (ISO 2592:2017)
ISO 2592:2017 specifies a procedure for the determination of flash and fire points of petroleum products using the Cleveland open cup apparatus. It is applicable to petroleum products having open cup flash points between 79 °C and 400 °C, except fuel oils which are most commonly tested by the closed cup procedure described in ISO 2719.
Mineralölerzeugnisse und verwandte Produkte - Bestimmung des Flamm- und Brennpunktes - Verfahren mit offenem Tiegel nach Cleveland (ISO 2592:2017)
Diese Internationale Norm legt ein Verfahren zur Bestimmung des Flammpunktes und des Brenn¬punktes von Mineralölprodukten unter Verwendung einer Prüfeinrichtung mit offenem Tiegel nach Cleveland fest. Sie gilt für Mineralölprodukte, deren Flammpunkte im offenen Tiegel zwischen 79 °C und 400 °C liegen, mit Ausnahme von Heizöl, die üblicherweise nach dem Verfahren im geschlossenen Tiegel nach ISO 2719 [5] geprüft werden.
Pétrole et produits connexes - Détermination de l'éclair et de feu points - Cleveland méthode vase ouvert (ISO 2592:2017)
ISO 2592:2017 spécifié une méthode pour la détermination des points d'éclair et de feu de produits pétroliers à l'aide de l'appareil Cleveland à vase ouvert. Elle s'applique aux produits pétroliers dont les points d'éclair en vase ouvert sont compris entre 79 et 400 °C, à l'exception des huiles combustibles, qui sont généralement soumises à essai à l'aide de la méthode en vase clos décrite dans l'ISO 2719.
Nafta in sorodni proizvodi - Določevanje plamenišča in točke gorenja - Metoda z odprto posodo po Clevelandu (ISO 2592:2017)
ISO 2592:2017 določa postopek za določevanje plamenišča in točke gorenja naftnih derivatov z uporabo odprte posode po Clevelandu. Uporablja se za naftne derivate z odprtimi plamenišči med 79 °C in 400 °C, razen za gorivna olja, ki jih najpogosteje preskušajo z metodo zaprte posode, opisano v standardu ISO 2719.
General Information
- Status
- Published
- Public Enquiry End Date
- 04-May-2016
- Publication Date
- 07-Nov-2017
- Technical Committee
- NAD - Petroleum products, lubricants and related products
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 25-Oct-2017
- Due Date
- 30-Dec-2017
- Completion Date
- 08-Nov-2017
Relations
- Effective Date
- 01-Dec-2017
Overview
EN ISO 2592:2017 / ISO 2592:2017 specifies the Cleveland open cup method for the determination of flash point and fire point of petroleum and related products. The method applies to samples with open-cup flash points between 79 °C and 400 °C (excluding fuel oils, which are commonly tested by the closed-cup method in ISO 2719). The standard was adopted by CEN as EN ISO 2592:2017 and supersedes the 2001 edition.
Key topics and technical requirements
- Scope and applicability - Open-cup flash point testing for petroleum products (79–400 °C).
- Definitions - Flash point (lowest temperature at which application of a test flame causes vapour to ignite, corrected to 101.3 kPa) and fire point (lowest temperature at which ignition is sustained for at least 5 s).
- Principle of test - Use of the Cleveland open cup apparatus; controlled heating of the test portion and periodic application of a test flame across the cup.
- Heating rates - Initial rapid warming (typically 5 °C/min to 17 °C/min), then slower constant rate (around 5 °C/min to 6 °C/min) as flash point is approached.
- Apparatus and verification - Detailed apparatus dimensions and verification procedures (Annex A and C); temperature measuring device requirements in Annex B.
- Sample handling and sampling - Guidance for sampling and subsampling, including references to ISO 3170 and ISO 3171 for sampling petroleum liquids.
- Special procedures - Annex D provides procedures to prevent surface skin formation when testing bitumens and asphalts.
- Precision and reporting - Repeatability and reproducibility criteria (note: reproducibility for flash point aligned to 18 °C to match ASTM D92); required test report content.
Practical applications
- Product classification and quality control in refineries, petrochemical plants and lubricant manufacturers.
- Safety data sheet (SDS) preparation, storage and handling risk assessments.
- Transport and storage hazard classification where open-cup flash points are required.
- Regulatory and compliance testing for petroleum-derived products.
- Validation and calibration of open-cup test equipment and laboratory competence checks.
Who should use this standard
- Industrial and commercial laboratories performing petroleum testing.
- Quality assurance and R&D teams in oil, lubricant and bitumen production.
- Test equipment manufacturers and calibration laboratories.
- Regulatory bodies and certification organizations assessing fire and flash properties.
Related standards and notes
- ISO 2719 - Closed cup flash point method (fuel oils).
- ISO 3170 / ISO 3171 - Sampling of petroleum liquids.
- Alignment with ASTM D92 is noted for precision and some procedures.
- Safety warning: the method involves hazardous materials and operations; follow appropriate lab safety and statutory requirements.
Keywords: EN ISO 2592:2017, ISO 2592:2017, Cleveland open cup, flash point, fire point, petroleum products, open cup flash point, CEN.
Frequently Asked Questions
SIST EN ISO 2592:2017 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Petroleum and related products - Determination of flash and fire points - Cleveland open cup method (ISO 2592:2017)". This standard covers: ISO 2592:2017 specifies a procedure for the determination of flash and fire points of petroleum products using the Cleveland open cup apparatus. It is applicable to petroleum products having open cup flash points between 79 °C and 400 °C, except fuel oils which are most commonly tested by the closed cup procedure described in ISO 2719.
ISO 2592:2017 specifies a procedure for the determination of flash and fire points of petroleum products using the Cleveland open cup apparatus. It is applicable to petroleum products having open cup flash points between 79 °C and 400 °C, except fuel oils which are most commonly tested by the closed cup procedure described in ISO 2719.
SIST EN ISO 2592:2017 is classified under the following ICS (International Classification for Standards) categories: 75.080 - Petroleum products in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 2592:2017 has the following relationships with other standards: It is inter standard links to SIST EN ISO 2592:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 2592:2017 is associated with the following European legislation: EU Directives/Regulations: 2008/68/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN ISO 2592:2017 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2017
1DGRPHãþD
SIST EN ISO 2592:2001
1DIWDLQVRURGQLSURL]YRGL'RORþHYDQMHSODPHQLãþDLQWRþNHJRUHQMD0HWRGD]
RGSUWRSRVRGRSR&OHYHODQGX,62
Petroleum and related products - Determination of flash and fire points - Cleveland open
cup method (ISO 2592:2017)
Mineralölerzeugnisse und verwandte Produkte - Bestimmung des Flamm- und
Brennpunktes - Verfahren mit offenem Tiegel nach Cleveland (ISO 2592:2017)
Pétrole et produits connexes - Détermination de l'éclair et de feu points - Cleveland
méthode vase ouvert (ISO 2592:2017)
Ta slovenski standard je istoveten z: EN ISO 2592:2017
ICS:
75.080 Naftni proizvodi na splošno Petroleum products in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 2592
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2017
EUROPÄISCHE NORM
ICS 75.080 Supersedes EN ISO 2592:2001
English Version
Petroleum and related products - Determination of flash
and fire points - Cleveland open cup method (ISO
2592:2017)
Pétrole et produits connexes - Détermination des Mineralölerzeugnisse und verwandte Produkte -
points d'éclair et de feu - Méthode Cleveland à vase Bestimmung des Flamm- und Brennpunktes -
ouvert (ISO 2592:2017) Verfahren mit offenem Tiegel nach Cleveland (ISO
2592:2017)
This European Standard was approved by CEN on 14 August 2017.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 2592:2017 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
This document (EN ISO 2592:2017) has been prepared by Technical Committee ISO/TC 28 "Petroleum
products and lubricants" in collaboration Technical Committee CEN/TC 19 “Gaseous and liquid fuels,
lubricants and related products of petroleum, synthetic and biological origin” the secretariat of which is
held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by March 2018 and conflicting national standards shall be
withdrawn at the latest by March 2018.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 2592:2001.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
the United Kingdom.
Endorsement notice
The text of ISO 2592:2017 has been approved by CEN as EN ISO 2592:2017 without any modification.
INTERNATIONAL ISO
STANDARD 2592
Third edition
2017-08
Petroleum and related products —
Determination of flash and fire points
— Cleveland open cup method
Pétrole et produits connexes — Détermination des points d’éclair et
de feu — Méthode Cleveland à vase ouvert
Reference number
ISO 2592:2017(E)
©
ISO 2017
ISO 2592:2017(E)
© ISO 2017, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – All rights reserved
ISO 2592:2017(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Chemicals and materials . 2
6 Apparatus . 2
7 Preparation of apparatus . 2
7.1 Location of apparatus . 2
7.2 Cleaning the test cup . 3
7.3 Preparing the test cup . 3
7.4 Assembly of apparatus . 3
7.5 Verification of apparatus . 3
8 Sampling . 3
9 Sample handling . 4
9.1 Subsampling . 4
9.2 Samples containing undissolved water . 4
9.3 Samples that are liquid at ambient temperature. 4
9.4 Samples that are semisolid or solid at ambient temperature . 4
10 Procedure for determining flash point . 4
11 Procedure for determining fire point . 6
12 Calculation . 6
13 Expression of results . 6
14 Precision . 7
14.1 General . 7
14.2 Repeatability, r . 7
14.3 Reproducibility, R . 7
15 Test report . 7
Annex A (normative) Cleveland open cup apparatus . 8
Annex B (normative) Temperature measuring device specification .11
Annex C (informative) Verification of apparatus .13
Annex D (informative) Prevention of surface skin formation when testing bitumens
and asphalts .16
Bibliography .18
ISO 2592:2017(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO’s adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: w w w . i s o .org/ iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 28, Petroleum and related products, fuels
and lubricants from natural or synthetic sources.
This third edition cancels and replaces the second edition (ISO 2592:2000), which has been technically
revised and aligned with ASTM D92.
The main technical changes compared to the previous edition are as follows:
a) Annex D on an alternative procedure for handling skin forming products has been added;
b) the temperature measuring device requirements in Annex B has been revised;
c) the flash point reproducibility has been changed from 17 °C to 18 °C, to align with ASTM D92 on the
basis of recent precision data;
d) a procedure to determine an approximate flash point of a sample with an unknown expected flash
point has been included, to align with ASTM D92.
iv © ISO 2017 – All rights reserved
INTERNATIONAL STANDARD ISO 2592:2017(E)
Petroleum and related products — Determination of flash
and fire points — Cleveland open cup method
WARNING — The use of this document can involve hazardous materials, operations and
equipment. This document does not purport to address all of the safety problems associated
with its use. It is the responsibility of users of this document to take appropriate measures to
ensure the safety and health of personnel prior to the application of this document, and fulfil
statutory and regulatory requirements for this purpose.
1 Scope
This document specifies a procedure for the determination of flash and fire points of petroleum
products using the Cleveland open cup apparatus. It is applicable to petroleum products having open
cup flash points between 79 °C and 400 °C, except fuel oils which are most commonly tested by the
closed cup procedure described in ISO 2719.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3170, Petroleum liquids — Manual sampling
ISO 3171, Petroleum liquids — Automatic pipeline sampling
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http:// www .electropedia .org/
— ISO Online browsing platform: available at http:// www .iso .org/ obp
3.1
flash point
lowest temperature of the test portion, corrected to a standard atmospheric pressure of 101,3 kPa, at
which application of a test flame causes the vapour of the test portion to ignite under the specified
conditions of test
Note 1 to entry: See 10.10.
3.2
fire point
lowest temperature of the test portion, corrected to a barometric pressure of 101,3 kPa, at which
application of a test flame causes the vapour of the test portion to ignite and sustain burning for a
minimum of 5 s under the specified conditions of test
4 Principle
The test cup is filled to a specified level with the test portion. The temperature of the test portion may
be increased rapidly (5 °C/min to 17 °C/min) at first and then at a slow constant rate (5 °C/min to
ISO 2592:2017(E)
6 °C/min) as the flash point is approached. At specified temperature intervals, a small test flame is
passed across the test cup.
The lowest temperature at which application of the test flame causes the vapour above the surface of the
liquid to ignite is taken as the flash point at ambient barometric pressure. To determine the fire point,
the test is continued until the application of the test flame causes the vapour above the test portion to
ignite and burn for at least 5 s. The flash point and fire point obtained at ambient barometric pressure
are corrected to standard atmospheric pressure using a formula.
5 Chemicals and materials
5.1 Cleaning solvent, for removal of traces of sample from the test cup and cover.
The choice of solvent depends upon the previous material tested and the tenacity of the residue. Low
volatility aromatic (benzene-free) solvents may be used to remove traces of oil, and mixed solvents can
be efficacious for the removal of gum type deposits.
5.2 Verification liquids, certified reference material (CRM) or secondary working standards (SWS)
(see, for instance, C.2).
5.3 Steel wool, any grade capable of removing carbon deposits without damage to the test cup.
6 Apparatus
6.1 Cleveland open cup apparatus, as specified in Annex A.
If automated equipment is used, ensure that it has been established that the results obtained are
within the precision of this document, that the test cup and test flame applicator conform to the
key dimensional and mechanical requirements specified in Annex A and the procedures described
in Clauses 7, 10 and 11 are followed. If automated testers are used, the user shall ensure that all the
manufacturer’s instructions for adjusting and operating the instrument are followed.
In cases of dispute, the flash point as determined manually shall be considered the referee test.
6.2 Shield, to cover at least three sides of the test cup.
The apparatus may include a built-in draught shield.
6.3 Temperature measuring device, which shall meet the requirements for accuracy and have the
response as specified in Annex B.
6.4 Barometer, reading absolute pressure accurate to 0,5 kPa with a resolution of 0,1 kPa.
Barometers precorrected to give sea level readings, such as those used at weather stations and airports,
shall not be used.
7 Preparation of apparatus
7.1 Location of apparatus
Place the apparatus (6.1) on a level and steady surface in a draught-free room (see below). Shield the top
of the manual apparatus from strong light by any suitable means to permit detection of the flash point.
When draughts cannot be avoided, it is recommended good practice to surround the apparatus with
a shield.
2 © ISO 2017 – All rights reserved
ISO 2592:2017(E)
When testing samples which produce toxic vapours, the apparatus may be located in a fume hood with
an individual control of air flow, adjusted so that vapours are withdrawn without causing air currents
over the test cup.
7.2 Cleaning the test cup
Wash the test cup with an appropriate solvent (5.1) to remove any traces of gum or residue remaining
from a previous test. Dry the test cup using a stream of clean air to ensure complete removal of the
solvent used. If any deposits of carbon are present, remove them by rubbing with steel wool (5.3).
7.3 Preparing the test cup
7.3.1 If the alternative procedure referred to in 10.1 is used, follow the instructions in Annex D.
7.3.2 Before use, cool the test cup to at least 56 °C below the expected flash point.
7.4 Assembly of apparatus
Support the liquid in glass thermometer in a vertical position with the bottom of the bulb (6,4 ± 0,5) mm
from the bottom of the test cup, and located at a point halfway between the centre and side of the test
cup on a diameter perpendicular to the arc (or line) of the sweep of the test flame, and on the side
opposite to the test flame applicator. It is not necessary to restrict electronic temperature measuring
devices to be mounted vertically, provided their performance is in accordance with the requirements in
the test method.
The vertical position of the temperature measuring device may be set by lowering until it contacts the
bottom of the test cup, and then raise it by (6,4 ± 0,5) mm.
7.5 Verification of apparatus
7.5.1 Verify the correct functioning of the apparatus at least once a year by testing a certified reference
material (CRM) (5.2). The result obtained shall be equal to or less than R/√2 from the certified value of
the CRM, where R is the reproducibility of the method (see Clause 14).
It is recommended practice during verification of an automated apparatus to visually observe the
detected flash point for correct operation.
It is recommended that more frequent verification checks are made using secondary working standards
(SWSs) (5.2) or other verification materials with a proven value.
A recommended procedure for apparatus verification using CRMs and SWSs, and the production of
SWSs, is given in Annex C.
7.5.2 The numerical values obtained during the verification check shall not be used to provide a bias
statement, nor shall they be used to make any correction to the flash points subsequently determined
using the apparatus.
7.5.3 It is good practice to select a CRM or SWS that has a certified value similar to the flash point of
products being tested.
8 Sampling
8.1 Unless otherwise specified, obtain samples for analysis in accordance with the procedures given in
ISO 3170, ISO 3171 or an equivalent national standard.
ISO 2592:2017(E)
8.2 Place samples in tightly sealed containers, appropriate to the material
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...