kSIST FprEN ISO 21569-1:2026
(Main)Horizontal methods for molecular biomarker analysis - Methods of analysis for the detection of genetically modified organisms and derived products - Part 1: Qualitative nucleic acid based methods (ISO/FDIS 21569-1:2026)
- Abstract
This International Standard describes the procedure to qualitatively detect genetically modified organisms
(GMOs) and derived products by analysing the nucleic acids extracted from the sample under study. The main
focus is on polymerase chain reaction (PCR) based amplification methods.
It gives general requirements for the specific detection and identification of target nucleic acid sequences
(DNA) and for the confirmation of the identity of the amplified DNA sequence.
Guidelines, minimum requirements and performance criteria laid down in this International Standard are
intended to ensure that comparable, accurate and reproducible results are obtained in different laboratories.
This International Standard has been established for food matrices, but could also be applied to other
matrices (e.g. feed and plant samples from the environment).
Specific examples of methods are provided in Annexes A to D.
- Status
- Not Published
- Public Enquiry End Date
- 30-Dec-2025
- Technical Committee
- KŽP - Agricultural food products
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 06-Nov-2026
- Due Date
- 25-Dec-2026
- Completion Date
- 10-Nov-2026
kSIST FprEN ISO 21569-1:2026 is a SIST draft of an ISO standard for detecting genetically modified organisms (GMOs) and derived products by qualitative nucleic acid analysis. It specifies PCR-based procedures for laboratories that test food matrices, and it can also be applied to feed and plant samples from the environment. The document focuses on target detection, confirmation of amplified DNA, controls, reporting, and the conditions needed to obtain comparable results between laboratories.
What does kSIST FprEN ISO 21569-1:2026 specify?
kSIST FprEN ISO 21569-1:2026 specifies the procedure for qualitative detection of GMOs and derived products by analysing extracted nucleic acids, with polymerase chain reaction (PCR) as the main approach. It sets general requirements for detecting target DNA sequences and confirming the identity of the amplified DNA sequence.
The document is organized into clauses 1 to 10, covering scope, normative references, terms and definitions, principle, reagents, apparatus and equipment, procedure, interpretation, expression of results and quality assurance, and test report. Annexes A to D provide specific example methods.
The standard is written for food matrices, but the scope also allows use with other matrices such as feed and plant samples from the environment. That matters in practice because the same analytical approach can support food testing, ingredient verification, and broader GMO screening work.
What are the key requirements of kSIST FprEN ISO 21569-1:2026?
The standard requires each qualitative method to name its target sequence and to show presence or absence relative to appropriate controls. In practice, a lab must be able to link every result to a defined GMO-related DNA target and not rely on an open-ended signal.
Clause 4 explains that PCR works through denaturation, primer annealing, and extension by DNA polymerase, and that PCR products are then detected and their identity confirmed. The document allows gel electrophoresis or another suitable detection step, and confirmation can use restriction analysis, hybridization, or DNA sequence analysis.
Clause 7 places strong emphasis on extract quality and PCR inhibition control. Nucleic acids should be sufficiently pure for analysis, repeatable in amount and quality, and free from inhibitors; where real-time PCR is used, dilution checks are used to show that inhibition is under control.
The document also sets expectations for PCR design and performance. Reaction conditions, especially MgCl concentration and thermocycling, should be optimized for each primer pair, and a new primer system must be shown not to create unwanted competing products. The text notes that an optimized PCR should detect low target copy numbers within 40 cycles and recommends hot-start PCR to reduce mispriming and primer-dimer formation.
Primer design and validation are treated as central technical steps. Primers should be selected with suitable length, annealing behavior, GC balance, and low risk of secondary structure, then checked first by sequence similarity search and then by experimental inclusivity and exclusivity testing. That matters because it is how a lab demonstrates that a method finds the target and avoids closely related non-target sequences.
Controls and reporting are also tightly defined. Each diagnostic PCR assay needs appropriate controls, certified reference materials should be used when suitable, and any positive or negative result must be expressed unambiguously with the limit of detection (LOD) and the method specificity. If results conflict or are ambiguous, the procedure is repeated, which helps prevent false positives and false negatives from becoming final reports.
What terms does kSIST FprEN ISO 21569-1:2026 define?
- Genetically modified organism (GMO) - The organismal source that the method is intended to detect through its nucleic acid signature.
- Polymerase chain reaction (PCR) - The amplification method used to make a target DNA sequence detectable.
- Deoxyribonucleoside triphosphate (dNTP) - The nucleotide building blocks added to the PCR reaction mixture.
- Limit of detection (LOD) - The lowest level that the method or sample context can support for a reported result.
- Qualitative result - A yes/no outcome showing whether the target DNA sequence was detected.
- Screening method - A method aimed at common GMO-related sequences rather than one specific event.
- Event-specific - A target chosen to identify a particular transformation event.
- Construct-specific - A target chosen to identify a particular genetic construct.
Who uses kSIST FprEN ISO 21569-1:2026?
kSIST FprEN ISO 21569-1:2026 is used by laboratories and analysts working on GMO detection in food matrices, feed, and plant samples from the environment. It is relevant to testing labs that extract nucleic acids, run PCR assays, validate primer systems, and issue results with defined controls and LODs.
It also supports quality managers and technical reviewers who need consistent reporting across laboratories. Buyers and regulators can use it to understand what a test method covers: screening, construct-specific detection, or event-specific identification.
What changed in kSIST FprEN ISO 21569-1:2026 from the previous edition?
This second edition cancels and replaces ISO 21569:2005. The foreword states that it includes the 2013 amendment, moves all annexed methods to ISO/TS 21569-11, and contains editorial revisions.
Which standards are used with kSIST FprEN ISO 21569-1:2026?
- ISO 21571 - Provides the nucleic acid extraction methods that feed the PCR analysis.
- ISO 24276 - Supplies the general requirements and definitions used throughout the document, including controls, reporting logic, and other shared requirements.
- ISO 11781 - Supports single-laboratory validation of qualitative real-time PCR methods.
- ISO/TS 21569-7:2022 - Gives a related real-time PCR method for CaMV and Agrobacterium Ti-plasmid derived DNA sequences.
What does the kSIST FprEN ISO 21569-1:2026 document contain?
kSIST FprEN ISO 21569-1:2026 contains a procedural framework rather than a single fixed test recipe. Clause 4 explains the analytical principle, Clause 5 lists reagents, Clause 6 points readers to equipment details, and Clause 7 covers extract quality, performance criteria, primer design, target descriptions, controls, and PCR set-up.
Clause 8 addresses how to interpret positive, negative, and ambiguous outcomes, while Clause 9 gives reporting language and quality assurance checks for replicate consistency. Clause 10 specifies the minimum information for the test report.
The document also includes annexes with specific example methods, which are intended to show how the general approach can be applied in practice.
Relations
- Effective Date
- 04-Sep-2024
- Effective Date
- 04-Sep-2024
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

Bureau Veritas
Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

DNV
DNV is an independent assurance and risk management provider.
Sponsored listings
Frequently Asked Questions
kSIST FprEN ISO 21569-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Horizontal methods for molecular biomarker analysis - Methods of analysis for the detection of genetically modified organisms and derived products - Part 1: Qualitative nucleic acid based methods (ISO/FDIS 21569-1:2026)". This standard covers: This International Standard describes the procedure to qualitatively detect genetically modified organisms (GMOs) and derived products by analysing the nucleic acids extracted from the sample under study. The main focus is on polymerase chain reaction (PCR) based amplification methods. It gives general requirements for the specific detection and identification of target nucleic acid sequences (DNA) and for the confirmation of the identity of the amplified DNA sequence. Guidelines, minimum requirements and performance criteria laid down in this International Standard are intended to ensure that comparable, accurate and reproducible results are obtained in different laboratories. This International Standard has been established for food matrices, but could also be applied to other matrices (e.g. feed and plant samples from the environment). Specific examples of methods are provided in Annexes A to D.
This International Standard describes the procedure to qualitatively detect genetically modified organisms (GMOs) and derived products by analysing the nucleic acids extracted from the sample under study. The main focus is on polymerase chain reaction (PCR) based amplification methods. It gives general requirements for the specific detection and identification of target nucleic acid sequences (DNA) and for the confirmation of the identity of the amplified DNA sequence. Guidelines, minimum requirements and performance criteria laid down in this International Standard are intended to ensure that comparable, accurate and reproducible results are obtained in different laboratories. This International Standard has been established for food matrices, but could also be applied to other matrices (e.g. feed and plant samples from the environment). Specific examples of methods are provided in Annexes A to D.
kSIST FprEN ISO 21569-1:2026 is classified under the following ICS (International Classification for Standards) categories: 67.050 - General methods of tests and analysis for food products. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN ISO 21569-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 21569:2005, SIST EN ISO 21569:2005/A1:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
kSIST FprEN ISO 21569-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 4.1 General
- 4.2 PCR amplification
- 4.3 Detection and confirmation of PCR products
- 5 Reagents
- 5.1 Target DNA/control
- 5.2 Water
- 5.4 PCR buffer solution
- 5.5 Thermostable DNA polymerase
- 5.6 Forward primer
- 5.7 Reverse primer
- 6 Apparatus and equipment
- 7 Procedure
- 7.1 Quality, integrity and amplifiability of nucleic acid extracts
- 7.2 Performance criteria
- 7.3 Aspects of PCR design
- 7.4 PCR target descriptions
- 7.5 Controls
- 7.6 PCR set-up, detection and confirmation of PCR products
- 8 Interpretation
- 8.1 General
- 8.2 Verification
- 9 Expression of results and quality assurance
- 9.1 General
- 9.2 Expression of a negative result
- 9.3 Expression of a positive result
- 9.4 Quality assurance requirements
- 10 Test report
- Bibliography
Introduction
The search for a genetically modified origin of ingredients is performed by means of the following successive (or simultaneous) steps. After sample collection, nucleic acids are extracted from the test portion. Extracted nucleic acids can be further purified, simultaneously or after the extraction process. Afterwards, they are quantified (if necessary), diluted (if necessary) and subjected to analytical procedures (such as PCR). These steps are detailed in this International Standard and in the following series of International Standards with the general title Foodstuffs — Methods of analysis for the detection of genetically modified organisms and derived products:
- Quantitative nucleic acid based methods (ISO 21570);
- Nucleic acid extraction (ISO 21571).
Further information about general requirements and definitions involving the steps cited above are collected in ISO 24276.
The qualitative detection of DNA target sequences is performed in order to obtain a yes or no answer to the question whether a certain target sequence is detected or not relative to appropriate controls and within the detection limits of the analytical method used and test portion analysed. The specificity of the methods, as described in ISO/TS 21569-11 and the other parts of this series, ranges from screening methods to detect common DNA sequences characteristic of GMOs, to specific identification of a genetic construct or a specific transformation event.
The International Organization for Standardization (ISO) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent. ISO takes no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured ISO that he/she is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with ISO. Information may be obtained from the patent database available at www.iso.org/patents.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those in the patent database. ISO shall not be held responsible for identifying any or all such patent rights.
oSIST prEN ISO 21569-1:2025
oSIST prEN ISO 21569-1:2025 DRAFT International Standard ISO/DIS 21569-1:2025(en) Horizontal methods for molecular biomarker analysis — Methods of analysis for the detection of genetically modified organisms and derived products — Part 1:
Qualitative nucleic acid based methods
1 Scope
This document describes the procedure to qualitatively detect genetically modified organisms (GMOs) and derived products by analysing the nucleic acids extracted from the sample under study. The main focus is on polymerase chain reaction (PCR) based amplification methods.
It gives general requirements for the specific detection and identification of target nucleic acid sequences (DNA) and for the confirmation of the identity of the amplified DNA sequence. Guidelines, minimum requirements and performance criteria laid down in this document are intended to ensure that comparable, accurate and reproducible results are obtained in different laboratories. This document has been established for food matrices, but could also be applied to other matrices (e.g. feed and plant samples from the environment).
Specific examples of methods are provided in ISO/TS 21569 part 11 and the other parts of this series.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 21571, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and derived products — Nucleic acid extraction ISO 24276:2006, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and derived products — General requirements and definitions ISO 24276, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and derived products — General requirements and definitions
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 24276 apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:
- IEC Electropedia: available at http:// www .electropedia .org/
- ISO Online browsing platform: available at http:// www .iso .org/ obp
oSIST prEN ISO 21569-1:2025 ISO/DIS 21569-1:2025(en)
4 Principle
4.1 General
Qualitative analysis consists of specific detection of target nucleic acid sequences in the test samples. Each method shall specify the target sequence.
A qualitative result shall clearly demonstrate the presence or absence of the genetic element under study, relative to appropriate controls.
NOTE Detection limits and size of the test portion are critical aspects of a method.
4.2 PCR amplification
Amplification of the target sequence occurs in vitro through a reaction catalysed by a DNA polymerase in the presence of oligonucleotide primers and deoxyribonucleoside triphosphates in a defined reaction buffer [1][2] . An important prerequisite for the amplification of the target sequence is that the reaction mixture contains no polymerase inhibitors. Amplification of the DNA is a cyclical process consisting of - denaturation of the double-stranded DNA into single-stranded nucleic acid by means of heating, - annealing of the primers to the target sequence at a suitable temperature, and - extension of the primers, which are bound to both single strands, by a DNA polymerase suitable for PCR, at an appropriate temperature.
4.3 Detection and confirmation of PCR products
PCR products are detected by gel electrophoresis or an appropriate alternative, if necessary, after isolation by means of a suitable separation procedure.
The identity of any detected target sequence can be verified by an appropriate technique (e.g. by restriction enzyme analysis, by hybridization or by DNA sequence analysis). In the case of real-time PCR analysis, amplification and detection occur simultaneously.
5 Reagents
It is generally advisable to store the reaction solutions required for the analytical method at approximately –20 °C if not specified otherwise.
It can also be appropriate to aliquot the reaction solutions required for the analytical method in order to avoid subjecting them to repeated freeze-thaw cycles, and/or to reduce chances of cross contamination.
5.1 Target DNA/control
5.2 Water
5.3 eoxyribonucleoside triphosphate (dNTP) solution, containing dATP, dCTP, dGTP, and dTTP / dUTP. NOTE The use of dUTP can interfere with restriction enzyme analyses of PCR products.
5.4 PCR buffer solution
The PCR buffer solution is usually delivered with the DNA polymerase, which may or may not include MgCl
in a concentration specified by the manufacturer. The final MgCl concentrations are method specific and are
therefore listed in the method. Ready-to-use reagents may be commercially available. The manufacturer’s instructions for use should be considered.
oSIST prEN ISO 21569-1:2025 ISO/DIS 21569-1:2025(en)
5.5 Thermostable DNA polymerase
5.6 Forward primer
5.7 Reverse primer
6 Apparatus and equipment
See ISO 24276 and the other parts of the ISO 21569 series for details.
7 Procedure
The basic principles of preparation of test samples (e.g. grinding, homogenization, division, drying) and of DNA extraction and purification are described in ISO 21571 and ISO 24276.
...