SIST EN 61076-2-106:2011
Connectors for electronic equipment - Product requirements - Part 2-106: Circular connectors - Detail specification for connectors m 16 x 0,75 with screw-locking and degree of protection ip40 or ip65/67
Connectors for electronic equipment - Product requirements - Part 2-106: Circular connectors - Detail specification for connectors m 16 x 0,75 with screw-locking and degree of protection ip40 or ip65/67
IEC 61076-2-106:2011 describes circular connectors with IP40 or IP65/67 protection degree, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M16 x 0,75 screw-locking. Male connectors have round contacts Ø 1,5 mm or Ø 1,0 mm.
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 2-106: Rundsteckverbinder - Bauartspezifikation für Steckverbinder M16 x 0,75 mit Schraubverriegelung und Schutzart IP40 oder IP65/67
Connecteurs pour équipements électroniques - Exigences relatives aux produits - Partie 2-106: Connecteurs circulaires - Spécification particulière pour les connecteurs m 16 x 0,75 à vis de degré de protection ip40 ou ip65/67
La CEI 61076-2-106:2011 décrit les connecteurs circulaires qui possèdent un degré de protection IP40 ou IP65/67, généralement utilisés dans le domaine des mesures et commandes des processus industriels. Ces connecteurs se composent d'embases et de fiches, pouvant être recâblées ou non, à vis M16 x 0,75. Les connecteurs mâles possèdent des contacts ronds de Ø 1,5 mm ou Ø 1,0 mm.
Konektorji za elektronsko opremo - Zahteve za izdelek - 2-106. del: Okrogli konektorji - Podrobna specifikacija za konektorje m 16 x 0,75 z vijačno zaporo in zaščitno stopnjo ip40 ali ip65/67
Ta mednarodni standard opisuje okrogle konektorje z zaščitno stopnjo IP40 ali IP65/67, ki se praviloma uporabljajo za merjenje in nadzor pri industrijskem postopku. Ti konektorji so sestavljeni iz fiksnih in prostih konektorjev, bodisi za večkratno priključitev ali ne, z vijačno zaporo M16 x 0,75. Moški konektorji imajo okrogle kontakte 1,5-mm ali 1,0-mm.
General Information
- Status
- Published
- Publication Date
- 14-Sep-2011
- Technical Committee
- I11 - Imaginarni 11
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 07-Sep-2011
- Due Date
- 12-Nov-2011
- Completion Date
- 15-Sep-2011
Overview
EN 61076-2-106:2011 (IEC 61076-2-106:2011) is the European/CENELEC detail specification for M16 × 0.75 screw‑locking circular connectors used in electronic equipment. It covers circular connector styles with degrees of protection IP40 or IP65/67, intended primarily for industrial process measurement and control applications. The standard defines mechanical and electrical product requirements, dimensional interfaces, contact arrangements and test schedules for fixed and free connectors (both rewireable and non‑rewireable). Male contacts are specified with contact diameters of Ø 1.5 mm or Ø 1.0 mm.
Key Topics
- Connector types and variants
- Fixed (panel-mounted) and free (cable) connector styles
- Rewireable and non‑rewireable free connectors
- Protective caps and accessories
- Mechanical and dimensional requirements
- Panel cut‑outs, interface dimensions for IP40 and IP65/67 variants
- Pin‑out layouts and polarizing methods
- Gauges for sizing and retention force
- Electrical and safety characteristics
- Rated voltages, impulse withstand and insulation coordination (referenced)
- Contact resistance and insulation resistance requirements
- Environmental and mechanical testing
- IP degree verification (IP40, IP65/67 per IEC 60529)
- Climatic classification, vibration, shock and mechanical endurance
- Insertion/withdrawal forces, contact retention, and dynamic stress tests
- Test schedule and conformity
- Detailed test groups (preliminary, dynamic/climatic, mechanical endurance, electrical load, chemical resistivity, connection method tests)
- Reference to related test standards (IEC 60512, IEC 60068 series)
Applications
EN 61076-2-106 is focused on practical, field‑oriented connector use in:
- Industrial process measurement and control systems
- Sensor, actuator and field instrument connections
- Control cabinets and panel‑mounted instrumentation
- Harsh environments requiring IP65/67 protection (washdown, dust, water ingress scenarios)
Keywords: M16 circular connector, M16 x 0.75 connector, screw‑locking connector, IP65 connectors, IP40 circular connectors, industrial connector standard.
Who uses this standard?
- Connector manufacturers and product designers specifying M16 circular connectors
- Electrical and mechanical design engineers in industrial automation
- Test laboratories and compliance teams verifying IP rating and mechanical/electrical performance
- Procurement and quality managers ensuring component interchangeability and standards compliance
- System integrators and maintenance personnel selecting field‑grade connectors for measurement & control installations
Related standards
- IEC/EN 61076‑1 (generic connector specification)
- IEC 60529 (IP Code - degrees of protection)
- IEC 60512 (connector tests and measurements)
- IEC 60068 (environmental testing)
- IEC 61984 (connector safety requirements)
This standard ensures interoperability, robust mechanical/electrical performance and proven environmental protection for M16 screw‑locking circular connectors in industrial applications.
Frequently Asked Questions
SIST EN 61076-2-106:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Connectors for electronic equipment - Product requirements - Part 2-106: Circular connectors - Detail specification for connectors m 16 x 0,75 with screw-locking and degree of protection ip40 or ip65/67". This standard covers: IEC 61076-2-106:2011 describes circular connectors with IP40 or IP65/67 protection degree, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M16 x 0,75 screw-locking. Male connectors have round contacts Ø 1,5 mm or Ø 1,0 mm.
IEC 61076-2-106:2011 describes circular connectors with IP40 or IP65/67 protection degree, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M16 x 0,75 screw-locking. Male connectors have round contacts Ø 1,5 mm or Ø 1,0 mm.
SIST EN 61076-2-106:2011 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61076-2-106:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2011
.RQHNWRUML]DHOHNWURQVNRRSUHPR=DKWHYH]DL]GHOHNGHO2NURJOL
NRQHNWRUML3RGUREQDVSHFLILNDFLMD]DNRQHNWRUMHP[]YLMDþQR]DSRURLQ
]DãþLWQRVWRSQMRLSDOLLS
Connectors for electronic equipment - Product requirements - Part 2-106: Circular
connectors - Detail specification for connectors m 16 x 0,75 with screw-locking and
degree of protection ip40 or ip65/67
Connecteurs pour équipements électroniques - Exigences relatives aux produits - Partie
2-106: Connecteurs circulaires - Spécification particulière pour les connecteurs m 16 x
0,75 à vis de degré de protection ip40 ou ip65/67
Ta slovenski standard je istoveten z: EN 61076-2-106:2011
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61076-2-106
NORME EUROPÉENNE
August 2011
EUROPÄISCHE NORM
ICS 13.220.10
English version
Connectors for electronic equipment -
Product requirements -
Part 2-106: Circular connectors -
Detail specification for connectors M 16 x 0,75 with screw-locking and
degree of protection IP40 or IP65/67
(IEC 61076-2-106:2011)
Connecteurs pour équipements Steckverbinder für elektronische
électroniques - Einrichtungen -
Exigences de produits - Produktanforderungen -
Partie 2-106: Connecteurs circulaires - Teil 2-106: Rundsteckverbinder -
Spécification particulière pour les Bauartspezifikation für Steckverbinder
connecteurs M 16 x 0,75 à vis de degré M16 x 0,75 mit Schraubverriegelung und
de protection IP40 ou IP65/67 Schutzart IP40 oder IP65/67
(CEI 61076-2-106:2011) (IEC 61076-2-106:2011)
This European Standard was approved by CENELEC on 2011-07-26. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61076-2-106:2011 E
Foreword
The text of document (48B/2239/FDIS), future edition 1 of IEC 61076-2-106, prepared by SC 48B,
Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic
equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 61076-2-106 on 2011-07-26.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-04-26
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-07-26
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61076-2-106:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 60130-9 NOTE Harmonized as EN 60130-9.
__________
- 3 - EN 61076-2-106:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60050-581 - International Electrotechnical Vocabulary - - -
Part 581: Electromechanical components for
electronic equipment
1)
IEC 60068-1 1988 Environmental testing - EN 60068-1 1994
+ corr. October 1988 Part 1: General and guidance
+A1 1992
IEC 60352-2 - Solderless connections - EN 60352-2 -
Part 2: Crimped connections - General
requirements, test methods and practical
guidance
IEC 60512 Series Connectors for electronic equipment - Tests EN 60512 Series
and measurements
IEC 60512-1-100 - Connectors for electronic equipment - Tests EN 60512-1-100 -
and measurements -
Part 1-100: General - Applicable publications
IEC 60529 1989 Degrees of protection provided by enclosures EN 60529 1991
(IP Code) + corr. May 1993
IEC 60664-1 2007 Insulation coordination for equipment within EN 60664-1 2007
low-voltage systems -
Part 1: Principles, requirements and tests
IEC 61076-1 - Connectors for electronic equipment - EN 61076-1 -
Product requirements -
Part 1: Generic specification
IEC 61076-2 - Connectors for electronic equipment - EN 61076-2 -
Product requirements -
Part 2: Sectional specification for circular
connectors
IEC 61984 2008 Connectors - Safety requirements and tests EN 61984 2009
ISO 1302 - Geometrical Product Specifications (GPS) - EN ISO 1302 -
Indication of surface texture in technical
product documentation
1)
EN 60068-1 includes A1 to IEC 60068-1 + corr. October .
IEC 61076-2-106 ®
Edition 1.0 2011-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electronic equipment – Product requirements –
Part 2-106: Circular connectors – Detail specification for connectors
M 16 × 0,75 with screw-locking and degree of protection IP40 or IP65/67
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 2-106: Connecteurs circulaires – Spécification particulière pour les
connecteurs M 16 × 0,75 à vis de degré de protection IP40 ou IP65/67
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX X
ICS 31.220.10 ISBN 978-2-88912-564-7
– 2 – 61076-2-106 IEC:2011
CONTENTS
FOREWORD . 6
1 Scope . 9
2 Normative references . 9
3 General information . 10
3.1 Definitions . 10
3.2 Number of contacts or contact cavities . 10
3.3 Ratings and characteristics . 10
3.4 Marking . 10
3.5 Safety aspects. 10
4 Dimensional information . 10
4.1 General . 10
4.2 Survey of styles and variants . 11
4.2.1 Fixed connectors . 11
4.2.2 Free connectors . 17
4.2.3 Accessories – Protective caps . 25
4.3 Interface dimensions . 26
4.3.1 Interface dimensions fixed connector for IP40 variants . 26
4.3.2 Interface dimensions free connector for IP40 variants . 27
4.3.3 Interface dimensions fixed connector for IP65/67 variants . 28
4.3.4 Interface dimensions free connector for IP65/67 variants . 29
4.3.5 Pin front view of connectors and contact position . 30
4.4 Sizing gauges and retention force gauges . 32
5 Characteristics . 32
5.1 Classification into climatic categories . 32
5.2 Electrical characteristics . 33
5.2.1 Rated voltage – Rated impulse voltage – Pollution degree . 33
5.2.2 Voltage proof . 33
5.2.3 Current-carrying capacity. 34
5.2.4 Contact resistance . 34
5.2.5 Insulation resistance . 34
5.3 Mechanical characteristics . 34
5.3.1 IP degree of protection . 34
5.3.2 Mechanical operation . 35
5.3.3 Insertion and withdrawal forces . 35
5.3.4 Contact retention in insert . 35
5.3.5 Polarizing method . 35
5.3.6 Vibration (sinusoidal) . 35
5.3.7 Shock . 35
6 Test schedule . 36
6.1 General . 36
6.1.1 Arrangement for contact resistance measurements. 36
6.1.2 Arrangement for dynamic stress tests (vibration) . 37
6.2 Test schedule . 38
6.2.1 Test group P – Preliminary . 38
6.2.2 Test group AP – Dynamic/ Climatic . 39
6.2.3 Test group BP – Mechanical endurance . 41
61076-2-106 IEC:2011 – 3 –
6.2.4 Test group CP – Electrical load . 42
6.2.5 Test group DP – Chemical resistivity . 42
6.2.6 Test group EP – Connection method tests . 43
Bibliography . 44
Figure 1 – Fixed connector, male contacts, IP40, front mounting . 11
Figure 2 – Fixed connector, male contacts, IP40, rear mounting . 12
Figure 3 – Fixed connector, male contacts, IP65/67, front mounting . 12
Figure 4 – Fixed connector, male contacts, IP65/67, rear mounting . 13
Figure 5 – Fixed connector, female contacts, IP40, front mounting . 14
Figure 6 – Fixed connector, female contacts, IP40, rear mounting . 14
Figure 7 – Fixed connector, female contacts, IP65/67, front mounting . 15
Figure 8 – Fixed connector, female contacts, IP65/67, rear mounting . 16
Figure 9 – Dimensions panel cut out IP40 . 16
Figure 10 – Dimensions panel cut out IP65/67 . 17
Figure 11 – Free connector, rewireable, straight version, cable outlet with clamping
ring, male contacts, IP40 . 18
Figure 12 – Free connector, rewireable, straight version, flexible cable boot, male
contacts, IP40 . 18
Figure 13 – Free connector, rewireable, right-angled version, flexible cable boot, male
contacts, IP40 . 19
Figure 14 – Free connector, rewireable, straight version, cable outlet with clamping
ring, male contacts, IP65/67 . 19
Figure 15 – Free connector, non-rewireable, straight version, flexible cable boot, male
contacts, IP65/67 . 20
Figure 16 – Free connector, rewireable, right-angled version, male contacts, IP65/67 . 20
Figure 17 – Free connector, non-rewireable, right-angled version, male contacts,
IP65/67 . 21
Figure 18 – Free connector, rewireable, straight version, cable outlet with clamping
ring, female contacts, IP40 . 21
Figure 19 – Free connector, rewireable, straight version, flexible cable boot, female
contacts, IP40 . 22
Figure 20 – Free connector, rewireable, right-angled version, flexible cable boot,
female contacts, IP40 . 22
Figure 21 – Free connector, rewireable, straight version, cable outlet with clamping
ring, female contacts, IP65/67 . 23
Figure 22 – Free connector, non-rewireable, straight version, female contacts, IP65/67 . 23
Figure 23 – Free connector, rewireable, right-angled version, female contacts, IP65/67 . 24
Figure 24 – Free connector, rewireable, right-angled version, female contacts, IP65/67 . 24
Figure 25 – Protective cap - connector with male contacts for IP40 variants . 25
Figure 26 – Protective cap- connector with female contacts for IP40 variants . 25
Figure 27 – Protective cap - connector with male contacts for IP65/67 variants . 25
Figure 28 – Protective cap- connector with female contacts for IP65/67 variants . 26
Figure 29 – Interface dimensions fixed connector for IP40 variants . 26
Figure 30 – Interface dimensions free connector for IP40 variants . 27
Figure 31 – Interface dimensions fixed connector for IP65/67 variants . 28
– 4 – 61076-2-106 IEC:2011
Figure 32 – Interface dimensions free connector for IP65/67 variants . 29
Figure 33 – Pin front view of connectors and contact position (variants 3 to 7a) . 30
Figure 34 – Pin front view of connectors and contact position (variants 7b to 19a) . 31
Figure 35 – Gauge dimensions . 32
Figure 36 – Contact resistance arrangement . 36
Figure 37 – Dynamic stress test arrangement . 37
Table 1 – Contact termination . 10
Table 2 – Styles of fixed connectors . 11
Table 3 – Dimension style AM . 11
Table 4 – Dimension style BM . 12
Table 5 – Dimension style CM . 13
Table 6 – Dimension style DM . 13
Table 7 – Dimension style AF . 14
Table 8 – Dimension style BF . 15
Table 9 – Dimension style CF . 15
Table 10 – Dimension style DF . 16
Table 11 – Dimension panel cut out IP65/67 . 17
Table 12 – Styles of free connectors . 17
Table 13 – Dimensions style IM . 18
Table 14 – Dimensions style JM. 18
Table 15 – Dimensions style KM . 19
Table 16 – Dimensions style LM . 19
Table 17 – Dimensions style MM . 20
Table 18 – Dimensions style NM . 20
Table 19 – Dimensions style OM . 21
Table 20 – Dimensions style IF . 21
Table 21 – Dimensions style JF . 22
Table 22 – Dimensions style KF . 22
Table 23 – Dimensions style LF . 23
Table 24 – Dimensions style MF . 23
Table 25 – Dimensions style NF. 24
Table 26 – Dimensions style OF . 24
Table 27 – Interface dimensions fixed connector for IP40 variants . 26
Table 28 – Interface dimensions free connector for IP40 variants . 27
Table 29 – Interface dimensions fixed connector for IP65/67 variants . 28
Table 30 – Interface dimensions free connector for IP65/67 variants. 29
Table 31 – Gauges . 32
Table 32 – Climatic category . 32
Table 33 – Rated voltage – Impulse voltage – Pollution degree . 33
Table 34 – Voltage proof connectors . 34
Table 35 – Number of mechanical operations . 35
Table 36 – Insertion and withdrawal forces . 35
61076-2-106 IEC:2011 – 5 –
Table 37 – Number of test specimens . 36
Table 38 – Test group P . 38
Table 39 – Test group AP . 39
Table 40 – Test group BP . 41
Table 41 – Test group CP . 42
Table 42 – Test group DP . 42
Table 43 – Test group EP . 43
– 6 – 61076-2-106 IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2-106: Circular connectors –
Detail specification for connectors M 16 × 0,75
with screw-locking and degree of protection IP40 or IP65/67
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61076-2-106 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
48/2239/FDIS 48/2246/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
61076-2-106 IEC:2011 – 7 –
A list of all parts of the IEC 61076 series, published under the general title Connectors for
electronic equipment – Product requirements, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 8 – 61076-2-106 IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC 61076-2-106
IEC SC 48B – Connectors
ELECTRONIC COMPONENTS
IN ACCORDANCE WITH IEC 61076-1
Circular connectors
M16 × 0,75 mm 2 to 8 poles,
12,14,19 poles
Connectors with round contact
Rewireable
Free cable connectors
Straight and right angle connectors
Fixed connectors
Flange mounting
Rear mounting
IEC 1500/11
61076-2-106 IEC:2011 – 9 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2-106: Circular connectors –
Detail specification for connectors M 16 × 0,75
with screw-locking and degree of protection IP40 or IP65/67
1 Scope
This International Standard describes circular connectors with IP40 or IP65/67 protection
degree, typically used for industrial process measurement and control. These connectors
consist of fixed and free connectors, either rewireable or non-rewireable, with M16 × 0,75
screw-locking. Male connectors have round contacts ∅ 1,5 mm or ∅ 1,0 mm.
NOTE IEC 60130-9, Edition 3.0 specified connectors with a similar mating interface for radio and associated
sound equipment. User of this standard should be aware that some of the IEC 60130-9 style could be mated to
some connector styles of this standard. However, IEC 60130-9:2011 (Edition 4.0) no longer includes these styles.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary – Part 581: Electromechanical
components for electronic equipment
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
Amendment 1 (1992)
IEC 60352-2, Solderless connections – Part 2: Crimped connections – General requirements,
test methods and practical guidance
IEC 60512 (all parts), Connectors for electronic equipment – Tests and measurements
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements –
Part 1-100: General – Applicable publications
IEC 60529:1989, Degrees of protection provided by enclosures (IP code)
IEC 60664-1:2007, Insulation coordination for equipment within low-voltage systems – Part 1:
Principles, requirements and tests
IEC 61076-1, Connectors for electronic equipment – Product requirements – Part 1: Generic
specification
IEC 61076-2, Connectors for use in d.c., low-frequency analogue and digital high speed data
applications – Part 2: Circular connectors with assessed quality – Sectional specification
IEC 61984:2008, Connectors –Safety requirements and tests
ISO 1302, Geometrical Product Specifications (GPS) – Indication of surface texture in
technical product documentation
– 10 – 61076-2-106 IEC:2011
3 General information
Throughout this detail specification dimensions are in mm.
3.1 Definitions
For the purposes of this International Standard, the terms and definitions given in
IEC 60050-581 apply.
3.2 Number of contacts or contact cavities
2 to 8, 12, 14 and 19 contacts.
The contact terminations shall be of the following types: crimp or solder.
Other termination types upon agreement.
Table 1 – Contact termination