Abstract

This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1, for balanced single-pair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C.
It specifies the common dimensions, and provides the mechanical, electrical, signal integrity, and environmental characteristics, the reliability specifications and corresponding tests for these connectors.

Status
Published
Public Enquiry End Date
31-Dec-2025
Publication Date
17-Aug-2026
Technical Committee
I11 - Imaginarni 11
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Aug-2026
Due Date
09-Oct-2026
Completion Date
18-Aug-2026

Buy Documents

Standard

SIST EN IEC 63171-1:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC 63171-1:2026 is a CENELEC European Standard for Type 1 (copper LC style) connectors for electrical and electronic equipment. It specifies the mechanical mating interface, pin assignment, and additional mechanical, electrical, signal integrity, environmental, and reliability requirements for 2-way shielded or unshielded free and fixed connectors used for balanced single-pair data transmission.

What does SIST EN IEC 63171-1:2026 specify?

SIST EN IEC 63171-1:2026 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1. The scope links these connectors to balanced single-pair data transmission with frequencies up to 600 MHz and current carrying capacity up to 2,0 A at 60 °C.

The document is organized into six clauses:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Terms and definitions
  • Clause 4 Common features and typical connector pair
  • Clause 5 Characteristics
  • Clause 6 Tests and test schedule

Annex ZA gives the normative references to international publications and their corresponding European publications. Figures and tables in Clauses 4 to 6 provide the interface drawings, dimensional data, and test arrangements that support the written requirements.

What are the key requirements of SIST EN IEC 63171-1:2026?

Mating interface and interoperability

SIST EN IEC 63171-1:2026 defines the common mating dimensions for the Type 1 connector interface in Clause 4. The drawings are given in millimetres, and the shapes may vary as long as the specified dimensions stay unchanged. For unshielded versions, the document keeps the same basic mating geometry as the shielded versions, with only the shield-related dimensions differing.

This matters because interchangeability depends on the interface geometry, not just on the product name. Clause 4.1.2 states that compliance with the interface dimensions and the relevant signal integrity tests is what allows connectors from different sources to work together in the same category.

Separation from LC fibre optic connectors

Clause 4.1.2 also makes clear that Type 1 connectors have features that prevent intermateability with standard LC fibre optic connectors according to IEC 61754-20. The document uses the copper LC style form factor, but the copper connector and the fibre optic connector are not meant to mate.

In practice, this avoids accidental cross-use in mixed installations. Buyers and designers can use the LC-like shape as a visual cue, but still need to specify the connector type correctly.

Pin assignment and climatic classification

Clause 5.2 fixes the pin assignment for Type 1 connectors by reference to Figure 4b. Clause 5.3 then ties the connector to a climatic category compatible with the M I C E environment classification in ISO/IEC 11801-1, using the category stated in the document.

This matters for system design and qualification because the connector is not only an interface component. It must also fit the environmental conditions expected in the installation.

Electrical performance

Clause 5.4 covers creepage and clearance, voltage proof, current-temperature derating, contact resistance, input-to-output DC resistance, unbalanced DC resistance, and initial insulation resistance. Table 4 gives the minimum creepage and clearance distances for contacts to chassis and between adjacent contacts.

For users, this is the section that supports insulation, safety, and power-carrying checks. It tells the test laboratory and the product engineer what electrical properties must be measured and how the connector interface is expected to behave.

Transmission performance

Clause 5.5 sets the transmission characteristics. The standard uses category B for insertion loss, return loss, transverse conversion loss, transverse conversion transfer loss, power sum alien NEXT, and power sum alien FEXT. Shielded connectors also have requirements for transfer impedance and coupling attenuation.

This is the part that matters most for data performance. It tells the reader that signal integrity is not left to vendor claims - it is part of the connector qualification.

Mechanical performance and testing

Clause 5.6 covers mechanical operation, connector coupling devices, insertion and withdrawal forces, polarizing method, and dynamic stress. The document uses Mating Performance Level MPL750 and the latch connector style for the relevant mechanical checks.

Clause 6 then turns those characteristics into test practice. It includes example arrangements for resistance measurements and a vibration test setup, plus preconditioning and both basic and full test schedules.

What terms does SIST EN IEC 63171-1:2026 define?

  • Type 1 - The connector family covered by this detail specification for balanced single-pair data transmission.
  • copper LC style - An electrical connector with a form factor similar to LC fibre optic connectors, but not intermateable with them.
  • Insertion loss (IL) - The transmission loss through the connector interface.
  • Return loss (RL) - The amount of signal reflected back from the connector interface.
  • Transverse conversion loss (TCL) - A measure of how much imbalance converts differential signals into common-mode signals.
  • Transverse conversion transfer loss (TCTL) - A related balance and conversion measure used for transmission performance.
  • Mating Performance Level MPL750 - The mechanical operation level used for the connector mating performance requirement.
  • M I C E - The environment classification referenced through ISO/IEC 11801-1 for installation conditions.

Who uses SIST EN IEC 63171-1:2026?

SIST EN IEC 63171-1:2026 is used by connector manufacturers, equipment makers, cable and cabling-system designers, test laboratories, and quality or procurement teams. It is relevant wherever balanced single-pair data transmission connectors must be specified, designed, qualified, or compared across suppliers.

In practice, these users rely on the standard to choose the connector interface, check interoperability, prepare data sheets, run qualification tests, and confirm that shielded or unshielded variants meet the intended application conditions.

What changed in SIST EN IEC 63171-1:2026 from the previous edition?

SIST EN IEC 63171-1:2026 supersedes EN IEC 63171-1:2020 and all of its amendments and corrigenda, if any. The underlying IEC edition identifies these notable updates compared with the previous edition:

  • updated information on obtaining a license agreement
  • alignment of connector characteristics and test requirements with IEC 63171:2021 where applicable
  • added requirements for polarizing method and dynamic stress
  • added test group BP - Moisture to align with IEC 63171:2021

Which standards are used with SIST EN IEC 63171-1:2026?

  • IEC 60050-581 - provides electromechanical vocabulary used for the terms and definitions.
  • IEC 60068-1 - provides general environmental testing guidance and supports the climatic classification.
  • IEC 60512-1 - provides the generic specification for connector tests and measurements.
  • IEC 61754-20 - gives the LC fibre optic connector family reference used to distinguish the copper LC style from fibre optic LC interfaces.
  • IEC 63171 - provides the general requirements and tests for the IEC 63171 series.
  • ISO/IEC 11801-1 - provides the generic cabling framework and the M I C E environment classification referenced in Clause 5.3.

What does the SIST EN IEC 63171-1:2026 document contain?

SIST EN IEC 63171-1:2026 contains connector overview drawings, mating-interface figures, pin detail drawings, and dimensional tables for the fixed and free connector parts. It also includes a table of creepage and clearance distances and a vibration test arrangement.

The document’s test section gives example measurement setups, preconditioning, and basic and full qualification schedules. Those schedules are used for design verification, laboratory testing, and product qualification of the connector family.

Annex ZA links the requirements to the corresponding European publications for the cited international standards.

Relations

Effective Date
01-Sep-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
04-Aug-2026
Effective Date
04-Aug-2026
Effective Date
04-Aug-2026

Buy Documents

Standard

SIST EN IEC 63171-1:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

SIST EN IEC 63171-1:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Connectors for electrical and electronic equipment - Part 1: Detail specification for 2-way, shielded or unshielded, free and fixed connectors - Mechanical mating information, pin assignment and additional requirements for Type 1 (copper LC style) (IEC 63171-1:2024)". This standard covers: This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1, for balanced single-pair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C. It specifies the common dimensions, and provides the mechanical, electrical, signal integrity, and environmental characteristics, the reliability specifications and corresponding tests for these connectors.

This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1, for balanced single-pair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C. It specifies the common dimensions, and provides the mechanical, electrical, signal integrity, and environmental characteristics, the reliability specifications and corresponding tests for these connectors.

SIST EN IEC 63171-1:2026 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC 63171-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC 63171-1:2020, SIST EN 60068-1:2014, SIST EN 61754-20:2012/A1:2022, SIST EN IEC 63171:2021, SIST EN IEC 60512-1:2019, SIST EN 61754-20:2012, SIST EN IEC 63171-5:2022, SIST EN 50173-10:2025, SIST EN IEC 60512-99-003:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC 63171-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 copper LC style
  • 4 Common features and typical connector pair
  • 4.1 Mating information
  • 5 Characteristics
  • 5.1 General
  • 5.2 Pin assignment
  • 5.3 Classification into climatic category
  • 5.4 Electrical characteristics
  • 5.5 Transmission characteristics
  • 5.6 Mechanical characteristics
  • 6 Tests and test schedule
  • 6.1 General
  • 6.2 Example of arrangement for input to output contact resistance measurement
  • 6.3 Example of arrangement for contact resistance measurement
  • 6.4 Arrangement for vibration test (test phase DP)
  • 1 Fixed connector
  • 2 Secure to the non-vibrating member
  • 3 Free connector
  • 4 Contact point
  • 5 Secure to the non-vibrating member
  • 7 Vibration table
  • 6.5 Test procedures and measuring methods
  • 6.6 Preconditioning
  • 6.7 Test schedules
  • Bibliography

INTRODUCTION The IEC 63171 series is a set of International Standards covering shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current carrying capacity. IEC 63171 is the general requirements and tests part (general specifications) of the whole series.

Subsequent parts, such as this Part 1, identified as IEC 63171 followed by a dash and a progressive number starting with 1, are the product detail specifications of this series and do not duplicate information given in this document, but list only additional requirements. Each subsequent part is identified by a type of connector covered with the same number identifying the part. Some parts can describe more embodiments, with different connectors geometries (rectangular, circular), sharing the core element and the relevant features. For the complete specifications regarding a connector of this series, both the general specification and the relevant detail specification are therefore required. For the qualification of a connector of this series, both the general specification and the relevant detail specification shall be met.

Figure 1 shows the interrelation of the standards.

SIST EN IEC 63171-1:2026

Figure 1 – Relationships between the IEC 63171 series and its related references NOTE The project for Type 3 connectors detail specification was cancelled.

SIST EN IEC 63171-1:2026

International Electrotechnical Commission IEC 63171-1 Ed2 Subcommittee 48B: Electrical connectors Two-way, free and fixed connectors for balanced singlepair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C.

Fixed connectors are mounted on printed circuit board or bulkhead, the free connector is terminated on shielded or unshielded wire.

View showing typical fixed and free connectors

Figure 2 – Connector overview

SIST EN IEC 63171-1:2026

CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT –

Part 1: Detail specification for 2-way, shielded or unshielded, free and fixed connectors – Mechanical mating information, pin assignment and additional requirements for Type 1 (copper LC style)

1 Scope

This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1, for balanced single-pair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C.

It specifies the common dimensions, and provides the mechanical, electrical, signal integrity, and environmental characteristics, the reliability specifications and corresponding tests for these connectors.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60050-581:2008, International Electrotechnical Vocabulary (IEV) – Part 581:

Electromechanical components for electronic equipment IEC 60068-1:2013, Environmental testing – Part 1: General and guidance IEC 60512-1:2018, Connectors for electrical and electronic equipment – Tests and measurements – Part 1: Generic specification IEC 61754-20:2012, Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces – Part 20: Type LC connector family IEC 61754-20:2012/AMD1:2022 IEC 63171:2021, Connectors for electrical and electronic equipment – Shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current-carrying capacity – General requirements and tests ISO/IEC 11801-1:2017, Information technology – Generic cabling for customer premises – Part 1: General requirements

3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 60050-581, IEC 60512-1 and IEC 63171 apply, as well as the following.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

SIST EN IEC 63171-1:2026

3.1 copper LC style

electrical connector having similar form factor to the LC fibre optic connectors according to IEC 61754-20, the two being not intermateable Note 1 to entry: The addition "copper" is used to distinguish between the two styles of connectors. Note 2 to entry: The Type 1 connectors are also known as "copper LC style".

4 Common features and typical connector pair

4.1 Mating information

4.1.1 General

Dimensions are given in millimetres. Drawings are shown in third-angle projection. The shape of connectors may deviate from those given in Figure 2 through Figure 6 as long as the dimensions specified are not changed (see also Table 1 through Table 3). Figure 4 and Figure 6 show the shielded connector variants.

Unshielded connectors shall conform to the specified fixed and free connector mating dimensions of shielded connectors shown in Figure 4, except for dimensions R, S, T and AN, and in Figure 6, except for dimensions AU, AV, and AW, the exceptions being related to the shield.

...