Information technology - Data centre facilities and infrastructures - Part 4-3: Renewable Energy Factor

This Amendment will update EN 50600-4-3 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-3: Anteil erneuerbarer Energien

Technologie de l’information - Installation et infrastructures de centres de traitement de données - Partie 4-3 : Coefficient d'énergie renouvelable

Informacijska tehnologija - Naprave in infrastruktura podatkovnih centrov - 4-3. del: Delež obnovljive energije - Dopolnilo A1

General Information

Status
Published
Public Enquiry End Date
25-Oct-2018
Publication Date
14-May-2019
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
19-Apr-2019
Due Date
24-Jun-2019
Completion Date
15-May-2019

Relations

Effective Date
01-Jun-2019

Overview

EN 50600-4-3:2016/A1:2019 (CLC) is a CENELEC amendment that updates Part 4-3 of the EN 50600 series: Renewable Energy Factor for data centre facilities and infrastructures. Published January 2019, this amendment revises measurement and calculation rules to re-align the Renewable Energy Factor (REF) KPI with recent findings from JTC 1/SC 39. It updates clause 5.2 (total data centre energy consumption) and Annex B (examples of REF calculation), and clarifies metering and conversion practices for fuels and thermal energy.

Key Topics and Requirements

  • Scope and purpose
    • Defines how to quantify the proportion of renewable energy used by a data centre (the Renewable Energy Factor).
    • Aligns REF methodology with JTC 1/SC 39 KPI developments.
  • Fuel metering and conversion
    • Gaseous and liquid fuels must be metered in kWh or converted to kWh using heat-of-combustion values.
    • Amendment provides example conversion values (as given in the amendment): diesel 9.9 kWh/l; gas 10.5 kWh/[unit as specified]; hydrogen 38.9 kWh/kg; bioethanol 6 kWh/l.
  • Thermal energy and cooling fluids
    • Energy contribution of cooling fluids is measured via heat meters (flow rate × ΔT) and multiplied by a system-specific conversion factor X.
    • Conversion factor X for thermal-to-electrical equivalent should be supplied by the energy provider; if unavailable, a default X = 0.4 is applied.
  • Technical subsystems and co-generation
    • On-site cogeneration and other technical subsystems must have meters at their output and are treated as external to the main data centre system for REF calculations.
  • Renewable energy certificates and accounting
    • Annex B examples (including updated Figure B.4) illustrate handling of locally generated energy sold to utilities and the retirement of renewable energy certificates (RECs) by the data centre.

Applications - who uses this standard

  • Data centre operators and facility managers calculating and reporting renewable energy share.
  • Energy and sustainability managers aligning REF with corporate KPIs and regulatory reporting.
  • Design and commissioning engineers specifying metering, energy conversion parameters, and on-site generation interfaces.
  • Auditors, consultants and certifiers assessing compliance with EN 50600 REF methodology and comparing KPI results.
  • Procurement teams when negotiating power purchase agreements (PPAs) and REC handling.

Related standards

  • EN 50600 series - broader guidance on data centre facilities and infrastructures.
  • JTC 1/SC 39 - international committee whose KPI findings prompted the amendment.

Keywords: EN 50600-4-3:2016/A1:2019, Renewable Energy Factor, data centre energy, CLC, CENELEC, metering, conversion factor, renewable energy certificates, REF.

Amendment

SIST EN 50600-4-3:2017/A1:2019 - BARVE

English language
5 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 50600-4-3:2017/A1:2019 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Information technology - Data centre facilities and infrastructures - Part 4-3: Renewable Energy Factor". This standard covers: This Amendment will update EN 50600-4-3 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

This Amendment will update EN 50600-4-3 requirements to re-align with the recent findings of JTC 1/SC 39 on this KPI.

SIST EN 50600-4-3:2017/A1:2019 is classified under the following ICS (International Classification for Standards) categories: 35.110 - Networking. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50600-4-3:2017/A1:2019 has the following relationships with other standards: It is inter standard links to SIST EN 50600-4-3:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50600-4-3:2017/A1:2019 is associated with the following European legislation: Standardization Mandates: M/462. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 50600-4-3:2017/A1:2019 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2019
Informacijska tehnologija - Naprave in infrastruktura podatkovnih centrov - 4-3.
del: Delež obnovljive energije - Dopolnilo A1
Information technology - Data centre facilities and infrastructures - Part 4-3: Renewable
Energy Factor
Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-3:
Anteil erneuerbarer Energien
Technologie de linformation - Installation et infrastructures de centres de traitement de
données - Partie 4-3 : Coefficient d'énergie renouvelable
Ta slovenski standard je istoveten z: EN 50600-4-3:2016/A1:2019
ICS:
35.110 Omreževanje Networking
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50600-4-3:2016/A1

NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2019
ICS 35.020; 35.110; 35.160
English Version
Information technology - Data centre facilities and infrastructures
- Part 4-3: Renewable Energy Factor
Technologie de l’information - Installation et infrastructures Informationstechnik - Einrichtungen und Infrastrukturen von
de centres de traitement de données - Partie 4-3 : Rechenzentren - Teil 4-3: Anteil erneuerbarer Energien
Coefficient d'énergie renouvelable
This amendment A1 modifies the European Standard EN 50600-4-3:2016; it was approved by CENELEC on 2019-01-18. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50600-4-3:2016/A1:2019 E
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...