SIST EN 61881-1:2011
(Main)Railway applications - Rolling stock equipment - Capacitors for power electronics - Part 1: Requirements, tests and general information (IEC 61881-1:2010)
Railway applications - Rolling stock equipment - Capacitors for power electronics - Part 1: Requirements, tests and general information (IEC 61881-1:2010)
IEC 61881-1:2010 applies to capacitors for power electronics intended to be used on rolling stock. The rated voltage of capacitors is limited to 10 000 V. The operating frequency of the systems in which these capacitors are used is usually up to 15 kHz, while the pulse frequencies may be up to 5 to 10 times the operating frequency. Distinguishes between AC and DC capacitors.
Bahnanwendungen - Betriebsmittel auf Bahnfahrzeugen - Kondensatoren für Leistungselektronik - Teil 1: Papier-/Foliekondensatoren (IEC 61881-1:2010)
Applications ferroviaires - Matériel roulant - Condensateurs pour électronique de puissance - Partie 1: Exigences, essais et informations générales (CEI 61881-1:2010)
La CEI 61881-1:2010 s'applique aux condensateurs pour électronique de puissance destinés à être utilisés sur le matériel roulant. La tension assignée des condensateurs est limitée à 10 000 V. La fréquence de fonctionnement des systèmes dans lesquels ces condensateurs sont utilisés atteint généralement jusqu'à 15 kHz, tandis que les fréquences d'impulsion peuvent atteindre de 5 à 10 fois la fréquence de fonctionnement. Une distinction est faite entre les condensateurs pour courant alternatif et ceux pour courant continu.
Železniške naprave - Oprema voznih sredstev - Kondenzatorji za močnostno elektroniko - 1. del: Zahteve, preskusi in splošne informacije (IEC 61881-1:2010)
Ta del IEC 61881 velja za kondenzatorje za močnostno elektroniko, namenjeno uporabi pri voznih sredstvih. Ocenjena napetost kondenzatorjev, zajeta v tem delu, je omejena do 10.000 V. Delovne frekvence sistemov, v katerih so kondenzatorji uporabljeni, so običajno do 15 kHz, medtem ko so pulzne frekvence lahko od 5- do 10-krat večje od delovnih frekvenc. Razlikuje med kondenzatorji z izmeničnim tokom in enosmernim tokom. Štejejo se kot sestavni deli, vgrajeni v ohišja. OPOMBA Ta standard zajema izjemno širok razpon tehnologij kondenzatorjev za različne uporabe: prenapetostna zaščita, filtriranje za enosmerni tok in izmenični tok, komutirana vezja, shranjevanje enosmerne energije, pomožni razsmerniki itd. Primeri so podani v klavzuli 9. Iz tega standarda so izvzeti: – kondenzatorji za obrate z indukcijsko proizvodnjo toplote, ki delujejo pri frekvencah med 40 Hz in 24.000 Hz (glej IEC 60100-1 in 60110-2); – kondenzatorji za uporabo v motorjih in podobno uporabo (glej IEC 60252-1 in IEC 60252-2); – kondenzatorji za uporabo v vezjih za blokiranje enega ali več harmonik v omrežnem napajanju; – majhni kondenzatorji za izmenični tok, kot se uporabljajo v fluorescenčnih lučeh in sijalkah (glej IEC 61048 in 61049); – kondenzatorji za dušenje radijskih motenj (glej IEC 60384-14); – ranžirni kondenzatorji za sisteme z izmeničnih tokom, ki ima ocenjeno napetost na 1000 V (glej IEC 60871-1 in IEC 60871-2); – ranžirni kondenzatorji samo okrevalne vrste za sisteme z izmeničnim tokom, ki imajo ocenjeno napetost do vključno z 1000 V (glej IEC 60831-1 in IEC 60831-2); – ranžirni kondenzatorji, ki niso samo okrevalne vrste, za sisteme z izmeničnim tokom, ki imajo ocenjeno napetost do vključno z 1000 V (glej IEC 60931-1 in IEC 60931-2); – serijski kondenzatorji za sisteme napajanja (glej IEC 60143-1, IEC 60143-2 in IEC 60143-3); - sklopni kondenzatorji in ločevalniki kondenzatorjev (glej IEC 60358); - kondenzatorji za aplikacije, ki potrebujejo shranjevanje energije/razelektritev pri visokih napetostih kot fotokopirni stroji in laserji; – kondenzatorji za mikrovalovne pečice; - kondenzatorji za močnostno elektroniko (glej IEC 61071).
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2011
1DGRPHãþD
SIST EN 61881:2001
äHOH]QLãNHQDSUDYH2SUHPDYR]QLKVUHGVWHY.RQGHQ]DWRUML]DPRþQRVWQR
HOHNWURQLNRGHO=DKWHYHSUHVNXVLLQVSORãQHLQIRUPDFLMH,(&
Railway applications - Rolling stock equipment - Capacitors for power electronics - Part
1: Requirements, tests and general information (IEC 61881-1:2010)
Bahnanwendungen - Betriebsmittel auf Bahnfahrzeugen - Kondensatoren für
Leistungselektronik - Teil 1: Papier-/Foliekondensatoren (IEC 61881-1:2010)
Applications ferroviaires - Matériel roulant - Condensateurs pour électronique de
puissance - Partie 1: Exigences, essais et informations générales (CEI 61881-1:2010)
Ta slovenski standard je istoveten z: EN 61881-1:2011
ICS:
31.060.70 0RþQRVWQLNRQGHQ]DWRUML Power capacitors
45.040 Materiali in deli za železniško Materials and components
tehniko for railway engineering
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61881-1
NORME EUROPÉENNE
February 2011
EUROPÄISCHE NORM
ICS 45.060 Supersedes EN 61881:1999
English version
Railway applications -
Rolling stock equipment -
Capacitors for power electronics -
Part 1: Paper/plastic film capacitors
(IEC 61881-1:2010)
Applications ferroviaires - Bahnanwendungen -
Matériel roulant - Betriebsmittel auf Bahnfahrzeugen -
Condensateurs pour électronique de Kondensatoren für Leistungselektronik -
puissance - Teil 1: Papier-/Foliekondensatoren
Partie 1: Condensateurs papier et film (IEC 61881-1:2010)
plastique
(CEI 61881-1:2010)
This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61881-1:2011 E
Foreword
The text of document 9/1405/FDIS, future edition 1 of IEC 61881-1, prepared by IEC TC 9, Electrical
equipment and systems for railways, was submitted to the IEC-CENELEC parallel vote and was approved
by CENELEC as EN 61881-1 on 2011-01-02.
This European Standard supersedes EN 61881:1999.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-10-02
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-02
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61881-1:2010 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60077-1:1999 NOTE Harmonized as EN 60077-1:2002 (modified).
IEC 60077-2:1999 NOTE Harmonized as EN 60077-2:2002 (modified).
IEC 60110-1:1998 NOTE Harmonized as EN 60110-1:1998 (not modified).
IEC 60146-1-1:2009 NOTE Harmonized as EN 60146-1-1:2009 (not modified).
IEC 60384-14:2005 NOTE Harmonized as EN 60384-14:2005 (not modified).
IEC 60664-1:2007 NOTE Harmonized as EN 60664-1:2007 (not modified).
IEC 60831-1:1996 NOTE Harmonized as EN 60831-1:1996 (not modified).
IEC 60831-2:1995 NOTE Harmonized as EN 60831-2:1996 (not modified).
IEC 60871-1:2005 NOTE Harmonized as EN 60871-1:2005 (not modified).
IEC 60931-1:1996 NOTE Harmonized as EN 60931-1:1996 (not modified).
IEC 60931-2:1995 NOTE Harmonized as EN 60931-2:1996 (not modified).
IEC 61071 NOTE Harmonized as EN 61071.
IEC 61287-1:2005 NOTE Harmonized as EN 61287-1:2006 (not modified).
__________
- 3 - EN 61881-1:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60068-2-14 - Environmental testing - EN 60068-2-14 -
Part 2-14: Tests - Test N: Change of
temperature
IEC 60068-2-20 - Environmental testing - EN 60068-2-20 -
Part 2-20: Tests - Test T: Test methods for
solderability and resistance to soldering heat
of devices with leads
IEC 60068-2-21 - Environmental testing - EN 60068-2-21 -
Part 2-21: Tests - Test U: Robustness of
terminations and integral mounting devices
IEC 60068-2-78 - Environmental testing - EN 60068-2-78 -
Part 2-78: Tests - Test Cab: Damp heat,
steady state
IEC 60269-1 - Low-voltage fuses - EN 60269-1 -
Part 1: General requirements
IEC 60695-2-11 - Fire hazard testing - EN 60695-2-11 -
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for end-products
IEC 60695-11-5 - Fire hazard testing - EN 60695-11-5 -
Part 11-5: Test flames - Needle-flame test
method - Apparatus, confirmatory test
arrangement and guidance
IEC 60721-3-5 - Classification of environmental conditions - EN 60721-3-5 -
Part 3: Classification of groups of
environmental parameters and their severities
- Section 5: Ground vehicle installations
IEC 61373 - Railway applications - Rolling stock equipment EN 61373 -
- Shock and vibration tests
IEC 62491 - Industrial systems, installations and EN 62491 -
equipment and industrial products - Labelling
of cables and cores
IEC 62497-1 - Railway applications - Insulation - -
coordination -
Part 1: Basic requirements - Clearances and
creepage distances for all electrical and
electronic equipment
IEC 61881-1 ®
Edition 1.0 2010-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Railway applications – Rolling stock equipment – Capacitors for power
electronics –
Part 1: Paper/plastic film capacitors
Applications ferroviaires – Matériel roulant – Condensateurs pour électronique
de puissance –
Partie 1: Condensateurs papier et film plastique
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
X
CODE PRIX
ICS 45.060 ISBN 978-2-88912-094-9
– 2 – 61881-1 © IEC:2010
CONTENTS
FOREWORD.5
1 Scope.7
2 Normative references.8
3 Terms and definitions .8
4 Service conditions.13
4.1 Normal service conditions.13
4.1.1 Altitude .13
4.1.2 Temperature.13
4.1.3 Operating temperature with forced ventilation.13
4.2 Unusual service conditions .13
5 Quality requirements and tests.14
5.1 Test requirements.14
5.1.1 General .14
5.1.2 Test conditions .14
5.2 Classification of tests.14
5.2.1 Routine tests .14
5.2.2 Type tests.15
5.2.3 Acceptance tests .15
5.2.4 Summary of tests.16
5.3 Capacitance and tan δ measurements (routine test) .16
5.3.1 Measuring procedure .16
5.3.2 Capacitance tolerances.17
5.3.3 Loss requirements (tan δ) .17
5.4 Capacitor loss tangent (tan δ) measurement (type test) .17
5.4.1 Measurements .17
5.4.2 Loss requirements .17
5.5 Voltage test between terminals .17
5.5.1 General .17
5.5.2 Routine test .18
5.5.3 Type test .18
5.6 AC voltage test between terminals and case .18
5.6.1 Routine test .18
5.6.2 Type test .19
5.7 Test of internal discharge device.19
5.8 Sealing test .19
5.9 Surge discharge test.19
5.10 Thermal stability test.20
5.10.1 General .20
5.10.2 Measuring procedure .20
5.11 Self-healing test.21
5.12 Resonance frequency measurement .21
5.13 Environmental testing .21
5.13.1 Change of temperature .21
5.13.2 Damp heat, steady state .21
5.14 Mechanical testing.22
5.14.1 Mechanical tests of terminals .22
61881-1 © IEC:2010 – 3 –
5.14.2 External inspection .23
5.14.3 Vibration and shocks.23
5.15 Endurance test .23
5.15.1 Conditioning of the units before the test .23
5.15.2 Initial capacitance and loss factor measurements.23
5.15.3 Endurance test .23
5.15.4 Final capacitance and tan δ measurement.24
5.15.5 Acceptance criteria .25
5.16 Destruction test .25
5.16.1 General .25
5.16.2 Test sequence for AC capacitors.26
5.16.3 Test sequence for DC capacitors .27
5.17 Disconnecting test on internal fuses.30
5.17.1 General .30
5.17.2 Disconnecting requirements .30
5.17.3 Withstand requirements .30
5.17.4 Test procedure .31
5.17.5 Capacitance measurement.32
5.17.6 Visual checking.32
5.17.7 Voltage test .32
5.18 Partial discharge measurements (optional type tests).32
6 Overloads.32
7 Safety requirements.33
7.1 Discharge device .33
7.2 Case connections .33
7.3 Protection of the environment .33
7.4 Fire hazard .33
7.5 Other safety requirements.33
8 Markings.34
8.1 Marking of the units .34
8.1.1 Rating plate .34
8.1.2 Data sheet .34
9 Guide to installation and operation .34
9.1 General .34
9.2 Choice of rated voltage.35
9.3 Operating temperature.35
9.3.1 Installation .35
9.3.2 Unusual cooling conditions.36
9.4 Special service conditions.36
9.5 Overvoltages .36
9.6 Overload currents .36
9.7 Switching and protective devices .37
9.8 Choice of creepage distance and clearance .37
9.9 Connections .37
9.10 Parallel connections of capacitors.37
9.11 Series connections of capacitors.37
9.12 Magnetic losses and eddy currents .38
9.13 Guide for internal fuse and disconnector protection in capacitors.38
9.14 Guide for unprotected capacitors .38
– 4 – 61881-1 © IEC:2010
Annex A (informative) Waveforms .39
Annex B (normative) Operational limits of capacitors with sinusoidal voltages as a
function of frequency and at maximum temperature (θ ) .41
max
Annex C (normative) Resonance frequency measuring methods – Examples .43
Bibliography .45
Figure 1 – Destruction test arrangement.27
Figure 2 – N source DC – type 1.29
Figure 3 – N source DC – type 2.29
Figure A.1a – Commutating waveform .39
Figure A.1b – Commutating circuit example.40
Figure A.1c – Damping capacitor for gate turn-off thyristors waveform .40
Figure A.1d – Damping circuit example .40
Figure B.1 – Supply conditions .41
Figure C.1 – Measuring circuit.43
Figure C.2 – Relation between the voltage across the capacitor and the supply
frequency.
Figure C.3 – Discharge current wave shape.44
Table 1 – Maximum temperature of cooling medium for unlimited time.13
Table 2 – Summary of tests.16
Table 3 – Test voltage between terminals.17
Table 4 – Damp heat test .22
Table 5 – Testing the robustness of terminals.22
Table 6 – Example of current-carrying capacities of screw terminals and bolts .23
Table 7 – Endurance test .24
Table 8 – Destruction test as a function of type of safety system.25
Table 9 – Maximum permissible voltage .32
61881-1 © IEC:2010 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RAILWAY APPLICATIONS –
ROLLING STOCK EQUIPMENT –
CAPACITORS FOR POWER ELECTRONICS –
Part 1: Paper/plastic film capacitors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61881-1 has been prepared by IEC technical committee 9: Electrical
equipment and systems for railways.
IEC 61881-1 cancels and replaces IEC 61881 (1999).
The text of this standard is based on the following documents:
FDIS Report on voting
9/1405/FDIS 9/1454/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 6 – 61881-1 © IEC:2010
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61881-1 © IEC:2010 – 7 –
RAILWAY APPLICATIONS –
ROLLING STOCK EQUIPMENT –
CAPACITORS FOR POWER ELECTRONICS –
Part 1: Paper/plastic film capacitors
1 Scope
This part of IEC 61881 applies to capacitors for power electronics intended to be used on
rolling stock.
The rated voltage of capacitors covered by this part is limited to 10 000 V.
The operating frequency of the systems in which these capacitors are used is usually up to
15 kHz, while the pulse frequencies may be up to 5 to 10 times the operating frequency.
It distinguishes between AC and DC capacitors.
They are considered as components mounted in enclosures.
NOTE This standard covers an extremely wide range of capacitor technologies for numerous applications:
overvoltage protection, DC and AC filtering, switching circuits, DC energy storage, auxiliary inverters, etc.
Examples are given in Clause 9.
The following are excluded from this standard:
– capacitors for induction heat-generating plants operating at frequencies between 40 Hz and
24 000 Hz (see IEC 60110-1 and 60110-2);
– capacitors for motor applications and the like (see IEC 60252-1 and IEC 60252-2);
– capacitors to be used in circuits for blocking one or more harmonics in power supply
networks;
– small AC capacitors as used for fluorescent and discharge lamps (see IEC 61048 and
IEC 61049);
– capacitors for suppression of radio interference (see IEC 60384-14);
– shunt capacitors for AC power systems having a rated voltage above 1 000 V (see
IEC 60871-1 and IEC 60871-2);
– shunt power capacitors of the self-healing type for AC systems having a rated voltage up to
and including 1 000 V (see IEC 60831-1 and IEC 60831-2);
– shunt power capacitor of the non self-healing type for AC systems having a rated voltage up
to and including 1 000 V (see IEC 60931-1 and IEC 60931-2);
– series capacitors for power systems (see IEC 60143-1, IEC 60143-2 and IEC 60143-3);
– coupling capacitors and capacitors dividers (see IEC 60358);
– capacitors for applications requiring energy storage/high current discharge such as
photocopiers and lasers;
– capacitors for microwave ovens;
– capacitors for power electronics (see IEC 61071).
– 8 – 61881-1 © IEC:2010
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60068-2-14, Environmental testing – Part 2-14: Tests. Test N: Change of temperature
IEC 60068-2-20, Environmental testing – Part 2-20: Tests. Test T: Test methods for
solderability and resistance to soldering heat of devices with leads
IEC 60068-2-21, Environmental testing – Part 2-21: Tests. Test U: Robustness of terminations
and integral mounting devices
IEC 60068-2-78, Environmental testing – Part 2-78: Tests. Test Cab: Damp heat, steady state
IEC 60269-1, Low-voltage fuses – Part 1: General requirements
IEC 60695-2-11, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-
wire flammability test method for end-products
IEC 60695-11-5, Fire hazard testing – Part 11-5: Test flames – Needle-flame test method –
Apparatus, confirmatory test arrangement and guidance
IEC 60721-3-5, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Section 5: Ground vehicles installations
IEC 61373, Railway applications – Rolling stock equipment – Shock and vibration tests
IEC 62491, Industrial systems, installations and equipment and industrial products – Labelling
of cables and cores
IEC 62497-1, Railway applications – Insulation coordination – Part 1: Basic requirements –
Clearances and creepage distance for all electrical and electronic equipment
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
capacitor element (or element)
indivisible part of a capacitor consisting of two electrodes separated by a dielectric
3.2
capacitor unit (or unit)
assembly of one or more capacitor elements in the same case with terminals brought out
3.3
capacitor bank
assembly of two or more capacitor units, electrically connected to each other
3.4
capacitor
general term used when it is not necessary to state whether reference is made to an element, a
unit or a capacitor bank
61881-1 © IEC:2010 – 9 –
3.5
capacitor equipment
assembly of capacitor units and their accessories intended for connection to a network
3.6
capacitor for power electronics
power capacitor intended to be used in power electronic equipment and capable of operating
continuously under sinusoidal and non sinusoidal current and voltage
3.7
metal-foil capacitor (non self-healing)
capacitor in which the electrodes usually consist of metal foils separated by a dielectric, in the
event of a breakdown of the dielectric; the capacitor does not restore itself
3.8
self-healing metallized dielectric capacitor
capacitor, the electrodes of which are metallized (usually by evaporation); in the event of
dielectric breakdown, the capacitor restores itself
3.9
AC capacitor
capacitor essentially designed for operation with alternating voltage
NOTE AC capacitors may be used with DC voltage up to the rated voltage only when authorized by the capacitor
manufacturer.
3.10
DC capacitor
capacitor essentially designed for operation with direct voltage
NOTE DC capacitors may be used with a specified AC voltage only where authorized by the capacitor
manufacturer.
3.11
model capacitor
smaller unit which simulates a complete unit or element in an electrical test, without reducing
the severity of the electrical, thermal or mechanical conditions
NOTE The combined sum of stresses should always be considered, for instance the sum of temperature,
mechanical conditions and electrical stresses.
3.12
internal (element) fuse
device incorporated in the capacitor which disconnects an element or a group of elements in
the event of breakdown
3.13
safety devices
3.13.1
overpressure disconnector
disconnecting device inside a capacitor, designed to interrupt the current path in case of
capacitor failure
3.13.2
overpressure detector
device designed to detect abnormal increase of the internal pressure by an electrical
switch/signal and indirectly interrupt the current path
– 10 – 61881-1 © IEC:2010
3.13.3
segmented metallization design
design of the metal layer over the dielectric shaped in a way to allow a small part of it to be
isolated in case of local short circuit or breakdown, in order to restore the full functionality of
the unit with a negligible loss of capacitance
3.13.4
special unsegmented metallization design
design of the metal layer over the dielectric shaped in a way that safe self-healing features
operating at a voltage up to U guarantee the full functionality of the unit with a negligible loss
s
of capacitance
3.14
discharge device of a capacitor
a device which may be incorporated in a capacitor, capable of reducing the voltage between
the terminals practically to zero, within a given time, after the capacitor has been disconnected
from a network
3.15
rated AC voltage (U )
N
maximum operating peak recurrent voltage of either polarity of a reversing type waveform for
which the capacitor has been designed
NOTE 1 The waveform can have many shapes. Examples are given in Annex A.
NOTE 2 The mean value of the waveform may be positive or negative.
NOTE 3 It is important to note that the rated AC voltage is not an r.m.s. value.
NOTE 4 Definitions used in this standard can be different from those of IEC 60077-1.
3.16
rated DC voltage (U )
NDC
maximum operating peak voltage of either polarity but of a non-reversing type waveform, for
which the capacitor has been designed, for continuous operation
Damping capacitors, for gate turn-off thyristor (GTO) can be regarded as DC capacitors with a
ripple voltage equal to the rated DC voltage U = U .
NDC r
In the case of reversal voltage, the use should be agreed between user and manufacturer.
NOTE If the reversal voltage is small (less than 10 %), the voltage waveform can be considered to be not
reversing. For test purposes, U and U should be increased by U, the reversal voltage.
NDC r
3.17
ripple voltage (U )
r
peak-to-peak alternating component of the unidirectional voltage
3.18
non-recurrent surge voltage (U )
s
peak voltage induced by a switching or any other disturbance of the system which is allowed for
a limited number of times and for durations shorter than the basic period
3.19
insulation voltage (U )
i
r.m.s. value of the sine wave voltage designed for the insulation between terminals of
capacitors to case or earth. If not specified, the r.m.s. value of the insulating voltage is equi-
valent to the rated voltage divided by 2.
61881-1 © IEC:2010 – 11 –
3.20
maximum peak current (Î)
maximum peak current that can occur during continuous operation
3.21
maximum current (I )
max
maximum r.m.s. current for continuous operation
3.22
maximum surge current (Î
s )
peak non-repetitive current induced by switching or any other disturbance of the system which
is allowed for a limited number of times, for durations shorter than the basic period
3.23
pulse frequency (f )
p
repetition rate of periodic current pulses
3.24
current pulse width (τ)
time of current flow during charging or discharging from one voltage value to another, of the
capacitor
NOTE Pulse current waveform examples are shown in Annex A.
3.25
resonance frequency (f )
r
lowest frequency at which the impedance of the capacitor becomes minimum
3.26
duty cycle
3.26.1
continuous duty
operation time such that a capacitor is at thermal equilibrium for most of the time
3.26.2
intermittent duty
discontinuous working or operation with variable loads which should be described in terms of
ON/OFF or HIGH/LOW periods with their durations
3.27
operating temperature
temperature of the hottest point on the case of the capacitor when in thermal equilibrium
3.28
lowest operating temperature (θ )
min
lowest temperature at which the capacitor may be energized
3.29
case temperature rise (Δθ )
case
difference between the temperature of the hottest point of the case and the temperature of the
cooling air
3.30
cooling-air temperature (θ )
amb
temperature of the cooling air measured at the hottest position of the capacitor, under steady-
state conditions, midway between two units
– 12 – 61881-1 © IEC:2010
If only one unit is involved, it is the temperature measured at a point approximately 0,1 m away
from the capacitor case and at two-thirds of the height from its base.
3.30.1
outlet fluid temperature for forced-cooled capacitors
temperature of the cooling fluid as it leaves the capacitor, measured at the hottest point
3.30.2
inlet fluid temperature for forced-cooled capacitors
temperature of the cooling fluid measured in the middle of the inlet fluid channel at a point not
influenced by the heat dissipation of the capacitor
3.31
maximum operating temperature (θ )
max
highest temperature of the case at which the capacitor may be operated
3.32
steady-state conditions
thermal equilibrium attained by the capacitor at constant output and at constant cooling-air
temperature
3.33
capacitor losses
active power consumed by a capacitor
NOTE Unless otherwise stated, the capacitor losses are understood to include losses in fuses and discharge
resistors forming an integral part of the capacitor.
At high frequency, the capacitor losses are predominantly due to losses in connections, contacts and electrodes.
3.34
tangent of the loss angle of a capacitor tan δ
ratio between the equivalent series resistance and the capacitive reactance of a capacitor at a
specified sinusoidal alternating voltage, frequency and temperature
tan δ = R ωC = tan + R ωC
esr d s
tan = dielectric loss factor
d
3.35
equivalent series resistance of a capacitor R
esr
effective resistance which, if connected in series with an ideal capacitor of capacitance value
equal to that of the capacitor in question, would have a power loss equal to active power
dissipated in that capacitor under specified operating conditions
3.36
series resistance R
s
effective ohmic resistance of the conductors of a capacitor under specified operating conditions
3.37
maximum power loss (P )
max
maximum power loss with which the capacitor may be loaded at the maximum case
temperature
3.38
maximum frequency for maximum power loss and maximum current (f )
frequency at which the maximum current (I ) produces the maximum power loss (P ) in the
max
max
capacitor. For explanation of (f ) see Annex B.
61881-1 © IEC:2010 – 13 –
4 Service conditions
NOTE See IEC 60077-1.
4.1 Normal service conditions
This standard gives requirements for capacitors intended for use in the following conditions:
4.1.1 Altitude
Not exceeding 1 400 m (IEC 62491 class A1).
NOTE The effect of altitude on convection cooling and external insulation should be taken into consideration, if the
altitude exceeds 1400 m. In this case the derating or a proper design shall be agreed between manufacturer and
user
4.1.2 Temperature
The climatic ambient temperatures are derived from IEC 60721-3-5 class 5k2 which has a
range from –25 °C to +40 °C.
Where ambient temperature lies outside this range, it shall be agreed between the user and the
manufacturer.
The upper limit of case temperature θ at which the capacitor may be operated, shall be
max
chosen among the values 55 °C, 70 °C and 85 °C.
4.1.3 Operating temperature with forced ventilation
If capacitors are intended for forced cooling with a fluid medium, the operating temperature
conditions specified in 4.1.2 shall be observed.
The following Table 1 of preferred temperatures of cooling fluid shall be applied.
Table 1 – Maximum temperature of cooling medium for unlimited time
Inlet temperature Outlet temperature
°C °C
35 40
45 50
55 60
The lowest inlet temperature for the cooling fluid may be –25 °C.
There are two methods of specifying the upper temperature limit of the cooling medium using
either the inlet temperature or the outlet temperature.
Unless otherwise agreed, the choice of method shall be left to the capacitor manufacturer.
For the inlet method, the flow of cooling medium shall be specified.
4.2 Unusual service conditions
This standard does not apply to capacitors, whose service conditions are such as to be in
general incompatible with its requirements, unless otherwise agreed between the manufacturer
and the user.
– 14 – 61881-1 © IEC:2010
Unusual service conditions require additional measurements, which ensure that the conditions
of this standard are complied with even under these unusual service conditions.
If such unusual service conditions exist then they shall be notified to the manufacturer of
the capacitor.
Unusual service conditions can include:
– unusual mechanical shocks and vibrations,
– cooling water with corrosive or obstructing particles (sea water, very hard water),
– corrosive and abrasive particles in the cooling air,
– dust in the cooling air, particularly if conductive,
– explosive dust or gas,
– oil or water vapour or corrosive substances,
– nuclear radiation,
– unusual storage or transport temperature,
– unusual humidity (tropical or subtropical region),
– excessive and rapid changes of temperature (more than 5 °C/h) or of humidity (more than
5 %/h),
– service areas higher than 1 400 m above sea level,
– superimposed electromagnetic fields,
– excessive overvoltages, as far as they exceed the limits given in Clause 6,
– airtight (poor change of air) installations.
5 Quality requirements and tests
5.1 Test requirements
5.1.1 General
This subclause gives the test requirements for capacitor units.
5.1.2 Test conditions
Unless otherwise specified for a particular test or measurement, the temperature of the
capacitor dielectric shall be in the +5 °C to +35 °C range.
If corrections are necessary, the reference temperature shall be +20 °C, unless otherwise
agreed between the manufacturer and the user.
NOTE It may be assumed that the dielectric temperature is the same as the ambient temperature, provided that
the capacitor has been left in an unenergized state, in a constant ambient temperature, for an adequate period of
time in order to reach thermal equilibrium.
The AC tests an
...