Fine ceramics (advanced ceramics, advanced technical ceramics) - Determination of oxidation resistance of non-oxide monolithic ceramics (ISO 20509:2003)

ISO 20509:2003 describes the method of test for determining the oxidation resistance of non-oxide monolithic ceramics, such as silicon nitride, sialon and silicon carbide at high temperatures. This International Standard is designed to provide an assessment of the mass and dimensional changes of test pieces following oxidation at high temperature in an oxidizing atmosphere, and to assess whether oxidation has a significant effect on the subsequent strength. This test method may be used for materials development, quality control, characterization, and design data generation purposes.

Hochleistungskeramik - Bestimmung der Beständigkeit von nichtoxidischer monolithischer Keramik gegen Oxidation (ISO 20509:2003)

Diese Internationale Norm beschreibt ein Prüfverfahren zur Bestimmung der Oxidationsbeständigkeit von nichtoxidischer monolithischer Keramik, wie z. B. Siliciumnitrid, Sialon  und Siliciumcarbid, bei hohen Temperaturen. Diese Internationale Norm ist dafür vorgesehen, eine Beurteilung der Massen- und Maßänderungen von Probekörpern nach der Oxidation bei hoher Temperatur in einer oxidierenden Atmosphäre zu ermöglichen und zu beurteilen, ob die Oxidation einen signifikanten Einfluss auf die spätere Festigkeit hat. Dieses Prüfverfahren darf für die Entwicklung, die Qualitätskontrolle, die Charakterisierung und die Generierung von auslegungsrelevanten Daten von Werkstoffen verwendet werden.

Céramiques techniques - Détermination de la résistance à l'oxydation des céramiques monolithiques (ISO 20509:2003)

La présente Norme internationale décrit la méthode d’essai permettant de déterminer la résistance à l’oxydation des céramiques monolithiques sans oxyde, telles que le nitrure de silicium, le Sialon et le carbure de silicium, à des températures élevées. La présente Norme internationale est destinée à fournir une évaluation des variations de masse et de dimensions des éprouvettes après oxydation à haute température dans une atmosphère oxydante, et à évaluer si l’oxydation a un effet significatif sur la résistance ultérieure. Cette méthode d’essai peut être utilisée pour le développement des matériaux, le contrôle de la qualité, la caractérisation et la génération de données de conception.

Fina keramika (sodobna keramika, sodobna tehnična keramika) - Ugotavljanje oksidacijske odpornosti neoksidne monolitne keramike (ISO 20509:2003)

Standard ISO 20509:2003 opisuje preskusno metodo za določanje oksidacijske odpornosti neoksidne monolitne keramike, kot je silicijev nitrid, sialon (silicij, aluminij, kisik in dušik) in silicijev karbid pri visokih temperaturah. Ta mednarodni standard je oblikovan tako, da zagotavlja oceno sprememb mase in dimenzij preskusnih vzorcev po oksidaciji pri visoki temperaturi v oksidacijski atmosferi in za ocenjevanje, ali ima oksidacija bistveni vpliv na nadaljnjo močne lastnosti. Ta preskusna metoda se lahko uporablja za razvoj materialov, nadzor kakovosti, določanje lastnosti in namene ustvarjanja podatkov o zasnovi.

General Information

Status
Published
Public Enquiry End Date
06-Feb-2023
Publication Date
12-Apr-2023
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
06-Apr-2023
Due Date
11-Jun-2023
Completion Date
13-Apr-2023

Buy Standard

Standard
EN ISO 20509:2023
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN ISO 20509:2023
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 20509:2023
01-maj-2023
Fina keramika (sodobna keramika, sodobna tehnična keramika) - Ugotavljanje
oksidacijske odpornosti neoksidne monolitne keramike (ISO 20509:2003)
Fine ceramics (advanced ceramics, advanced technical ceramics) - Determination of
oxidation resistance of non-oxide monolithic ceramics (ISO 20509:2003)
Hochleistungskeramik - Bestimmung der Beständigkeit von nichtoxidischer
monolithischer Keramik gegen Oxidation (ISO 20509:2003)
Céramiques techniques - Détermination de la résistance à l'oxydation des céramiques
monolithiques (ISO 20509:2003)
Ta slovenski standard je istoveten z: EN ISO 20509:2023
ICS:
81.060.30 Sodobna keramika Advanced ceramics
SIST EN ISO 20509:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN ISO 20509:2023

---------------------- Page: 2 ----------------------
SIST EN ISO 20509:2023


EN ISO 20509
EUROPEAN STANDARD

NORME EUROPÉENNE

March 2023
EUROPÄISCHE NORM
ICS 81.060.30
English Version

Fine ceramics (advanced ceramics, advanced technical
ceramics) - Determination of oxidation resistance of non-
oxide monolithic ceramics (ISO 20509:2003)
Céramiques techniques - Détermination de la Hochleistungskeramik - Bestimmung der Beständigkeit
résistance à l'oxydation des céramiques monolithiques von nichtoxidischer monolithischer Keramik gegen
(ISO 20509:2003) Oxidation (ISO 20509:2003)
This European Standard was approved by CEN on 10 March 2023.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 20509:2023 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN ISO 20509:2023
EN ISO 20509:2023 (E)
Contents Page
European foreword . 3

2

---------------------- Page: 4 ----------------------
SIST EN ISO 20509:2023
EN ISO 20509:2023 (E)
European foreword
The text of ISO 20509:2003 has been prepared by Technical Committee ISO/TC 206 "Fine ceramics” of
the International Organization for Standardization (ISO) and has been taken over as EN ISO 20509:2023
by Technical Committee CEN/TC 184 “Advanced technical ceramics” the secretariat of which is held by
DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2023, and conflicting national standards
shall be withdrawn at the latest by September 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO 20509:2003 has been approved by CEN as EN ISO 20509:2023 without any modification.

3

---------------------- Page: 5 ----------------------
SIST EN ISO 20509:2023

---------------------- Page: 6 ----------------------
SIST EN ISO 20509:2023
INTERNATIONAL ISO
STANDARD 20509
First edition
2003-12-01
Fine ceramics (advanced ceramics,
advanced technical ceramics) —
Determination of oxidation resistance of
non-oxide monolithic ceramics
Céramiques techniques — Détermination de la résistance à l'oxydation
des céramiques monolithiques

Reference number
ISO 20509:2003(E)
©
ISO 2003

---------------------- Page: 7 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2003 – All rights reserved

---------------------- Page: 8 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Apparatus . 2
5 Test pieces . 3
6 Test procedure . 3
7 Calculations . 5
8 Test report . 7
Annex A (informative) Useful information . 8
Annex B (informative) Interlaboratory evaluation of the test method . 9
Bibliography . 11
©
ISO 2003 – All rights reserved iii

---------------------- Page: 9 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 20509 was prepared by Technical Committee ISO/TC 206, Fine ceramics.
©
iv ISO 2003 – All rights reserved

---------------------- Page: 10 ----------------------
SIST EN ISO 20509:2023
INTERNATIONAL STANDARD ISO 20509:2003(E)
Fine ceramics (advanced ceramics, advanced technical
ceramics) — Determination of oxidation resistance of non-oxide
monolithic ceramics
1Scope
This International Standard describes the method of test for determining the oxidation resistance of non-oxide
1)
monolithic ceramics, such as silicon nitride, Sialon and silicon carbide at high temperatures. This International
Standard is intended to provide an assessment of the mass and dimensional changes of test pieces following
oxidation at high temperature in an oxidizing atmosphere, and to assess whether oxidation has a significant
effect on the subsequent strength. This test method may be used for materials development, quality control,
characterization, and design data generation purposes.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3611:1978, Micrometer callipers for external measurement
ISO 6906:1984, Vernier callipers reading to 0,02 mm
2)
ISO 7500-1:— , Metallic materials — Verification of static uniaxial testing machines — Part1:
Tension/compression testing machines — Verification and calibration of the force-measuring system
ISO 14704:2000, Fine ceramics (advanced ceramics, advanced technical ceramics) — Test method for flexural
strength of monolithic ceramics at room temperature
IEC 60584-1:1995, Thermocouples — Part 1: Reference tables
IEC 60584-2:1989, Thermocouples — Part 2: Tolerances
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
oxidation resistance
resistance against oxidation of a non-oxide ceramic material due to reaction with oxygen in the surrounding
atmosphere, including any internal reactions as a result of the presence of open porosity or of diffusion of ions
to or from the ceramic surface
3.2
flexural strength
maximum nominal stress at fracture of a specified elastic beam loaded in bending
1) Sometimes written SiAlON is the acronym for a ceramic that contains silicon, aluminium, oxygen and nitrogen.
2) To be published. (Revision of ISO 7500-1:1999)
©
ISO 2003 – All rights reserved 1

---------------------- Page: 11 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
4 Apparatus
4.1 High temperature furnace, e.g. any suitable air atmosphere furnace with a nominal temperature

capability of at least 1 500 C.
The furnace chamber shall have an inlet for a sufficient supply of oxidation gas to ensure that the atmosphere
does not stagnate and become oxygen deficient. The temperature shall be capable of being raised to that
◦ −1 ◦
required for testing at a minimum of 5 C min , of being controlled to better than ± 5 C at all oxidation
◦ −1 ◦
temperatures, and of being cooled at more than 5 C min to below 800 C. Before commencing oxidation
tests, the furnace chamber shall be baked out using the same atmosphere as proposed for testing and at a
temperature at least as high as the intended oxidation test temperature for a period of at least 10 h in order to
remove contaminants.
4.2 Support or supporting stand, for oxidation tests.
The test pieces shall be supported using techniques that minimize contact area, degree of adhesion and extent
of reaction with the test piece (see Figure 1). Preferably this should be done using point or line contact only. Any
contact of the supports with the regions of the test piece surfaces to be subjected later to loading roller contact
in flexural strength testing shall be avoided. Examples of suitable support methods include the use of a block
with drilled holes no more than 3mm deep such that the test pieces can stand near vertically with a minimum of
end and edge contact. The samples can also be situated on horizontal supports on rollers of silicon carbide or
mullite, on small diameter platinum wires, either suspended or resting on a clean non-reactive ceramic surface,
or on semi-rings which can be cut from ceramic tubes (alumina, mullite, silicon carbide, or silicon nitride).
a) b) c) d)
a) a refractory block with appropriate-sized holes in it, suitable for muffle furnace;
b) a support system based on tubes and discs with holes, suitable for vertical tube furnace;
c) a pair of supported parallel rods spaced near the ends of the test-pieces and with an adequate gap underneath,
suitable for a muffle furnace;
d) a test-piece supported by its ends on a ceramic semi-ring.
Figure 1 — Examples of support systems for flexural strength test pieces
NOTE 1 It may be necessary to perform some preliminary assessments to ensure that the supporting material is
sufficiently non-reactive as to not significantly contribute to the mass changes in the sample.
NOTE 2 Candidate materials for supporting test pieces include silicon carbide, mullite, platinum wire and alumina. Silicon
carbide and mullite may be the most suitable materials. Alumina may react with test pieces, and platinum is inappropriate for
non-oxide ceramics containing free metallic species, such as silicon carbide containing silicon.
◦ ◦
4.3 Oven, capable of maintaining a temperature of 105 C to 120 C.
4.4 Testing machine for flexural strength, capable of applying a uniform crosshead speed. The testing
machine shall be in accordance with ISO 7500-1:— Class 1 with an accuracy of 1% of indicated load at
fracture.
©
2 ISO 2003 – All rights reserved

---------------------- Page: 12 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
4.5 Testing fixture for flexural strength, of three- or four-point flexure configuration in accordance with 5.2
of ISO 14704:2000. The recommended fixture is fully articulated and of the four-point-1/4 point configuration
with the two outer bearings at a distance of 40 mm. The corresponding total length of test piece is � 45 mm.
4.6 Micrometer, such as shown in ISO 3611:1978 but with a resolution of 0,002 mm for measuring the test
piece dimensions. The micrometer shall have flat anvil faces such as shown in ISO 3611:1978. The micrometer
shall not have a ball tip or sharp tip since these might damage the test piece. Alternative dimension measuring
instruments may be used provided that they have a resolution of or finer.
0,002 mm
4.7 Vernier calliper, with a resolution of 0,05 mm or finer for measuring the length of the test piece, in
accordance with ISO 6906. Alternative dimension measuring instruments may be used provided that they have
a resolution of 0,05 mm or finer.
4.8 Balance, capable of weighing up to 200 g with a sensitivity of at least 0,05 mg.
4.9 Thermocouple, of type R or type S in accordance with IEC 60584-2, permitting the use of the calibration
table given in IEC 60584-1.
5 Test pieces
If the strength changes are to be determined, flexural strength test pieces in accordance with Clause 6 of
ISO14704:2000 shall be used. The standard test specimens shall have cross-sectional dimensions of
3,00 mm ± 0,20 mm thickness and 4,00 mm ± 0,20 mm width. The length shall be more than 35 mm for
30 mm test fixtures or more than 45 mm for 40 mm test fixtures. All the surfaces shall be machined, and edges
shall be rounded or chamfered. Any machining procedure and the surface quality of the test pieces shall be
reported. The minimum number of test pieces shall be 10 for each oxidation condition to be tested, plus 10 test
pieces as an unoxidized control. Means shall be taken to identify individually, similar test pieces, but shall not be
marked or scribed in a way that might affect the result of the test. If strength changes are not to be determined,
any test piece, in terms of size and shape, may be used.
Test pieces shall be clean and free from preparation residues and contamination due to handling which can
influence the initial mass measurement and/or the oxidation rate. The test-piece cleaning procedure shall be
stated in the report.
For materials with no significant open porosity and contaminated by handling, and/or by mounting or machining
coolant residues, submerge the test-pieces in ethanol in an ultrasonic bath and agitate for at least 10 min. In
order to avoid damage, test pieces shall not be allowed to contact either each other or a hard surface during this
operation. For materials containing open porosity, internally entrained organic residues can be removed only by
heating in air. The maximum temperature to which this should be done will depend on the material type, but
◦ ◦
typically a temperature of 500 C to 600C1 for a least h is required to oxidize carbonaceous residues.

Material with intentionally present free carbon shall be treated at a maximum temperature of 350 C to avoid
oxidation.
6 Test procedure
6.1 Measurements of dimensions and mass of specimens
For flexural strength test pieces, measure the width, bh, and thickness, , of each test piece at several places
using the micrometer (4.5) with a resolution of 0,002 mm. Measure the overall length, L , with the vernier
T
callipers (4.6) with a resolution of 0,05 mm. For other shapes of test piece, measure relevant dimensions at
several different places (e.g. diameter and thickness of a disc). Wash and degrease the test pieces (see
◦ ◦
Clause 5). Place in the oven (4.3) and heat to a temperature of 105 C to 120 C until their mass is constant.
Remove and store in a desiccator. When cooled to room temperature, weigh each test piece to the nearest
0,05 mg using the balance (4.7). Store in the desiccator until tested.
©
ISO 2003 – All rights reserved 3

---------------------- Page: 13 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
6.2 Baking out in the oxidation furnace
Unless used for a similar measurement immediately prior to the test, pre-condition the furnace (4.1) and the test
piece support system (4.2) at a temperature similar to or greater than that intended for the oxidation test under
the intended flowing gas atmosphere. The maximum temperature shall be maintained for at least 10 h.
6.3 Oxidation test
6.3.1 Materials with high oxidation resistance
6.3.1.1 Place the test pieces on their supports (4.2) in the centre of the hot zone of the furnace (4.1) ensuring
sufficient space between test pieces and their supports for adequate circulation of air. Ensure that contact with
supports is minimized (see Figure 1). The contacts shall always be at locations outside the outer span used for
the flexural test. The minimum spacing between test pieces as well as that between a test piece and furnace
furniture shall be 5mm.
NOTE 1 It is preferred that each batch of a least 10 test pieces per oxidation condition is exposed at the same time in the
same facility. Separated exposure at separate times may result in slightly different results.
NOTE 2 The minimum spacing between components or test-pieces under test should be increased with increasing
component or test-piece size to ensure unimpeded gas flow between neighbouring oxidizing surfaces.
6.3.1.2 Position a type R or type S thermocouple (4.8) in accordance with IEC 60584-2 adjacent to the test
pieces for the purposes of monitoring test piece temperature during the oxidation period. Close the furnace.
6.3.1.3 Supply the oxidizing gas at a rate sufficient to provide atmosphere circulation within the furnace cavity
and around the test pieces such that stagnation and oxygen depletion is avoided, but not at such a rate that
results in inhomogeneous or fluctuating furnace temperature. For testing in normal air, a natural flow of the air
through the furnace cavity shall be facilitated. Note that a gas flow rate is recommended of between typically 0,5
and 50 volume changes per hour, but not less than 0,1 changes per hour.
6.3.1.4 Heat the furnace to the test temperature as indicated by the measuring thermocouple adjacent to the

test pieces. Maintain this temperature to within 5 C for the required oxidation period. Cool the furnace at the
maximum rate of cooling of the furnace and carefully remove the test pieces from their supports and place in a
desiccator. To avoid contamination, do not touch the test pieces with naked fingers until after the final weighing.
Ensure that loose deposits on the test piece surface are retained intact as far as possible.
6.3.2 Materials with low oxidation resistance
The procedure outlined in 6.3.1 can be also used in the testing of materials with low oxidation resistance or
those producing low melting oxidation products, such as B O formed during the oxidation of borides. Some
2 3
modifications are suggested for the samples that react significantly with or stick to the support fixture. In these
cases, it is recommended to use a system supporting each individual sample, such as the semi-rings [Figure 1
d)], so that the sample and the support can be weighed together before and after the test.
Additionally, the samples should be inserted into a furnace, preheated to the test temperature, and then air-
quenched after the test to retain the high temperature condition of the surface layer for room temperature
microscopic evaluation. Nevertheless, the quenching of the samples can affect the strength as a result of
thermal shock.
6.4 Selecting test conditions
Test conditions (temperature, atmosphere, duration, etc.) shall be selected according to the technical
requirements for undertaking the test and on agreement between parties.

NOTE 1 The test condition recommended for silicon nitrides and Sialons is 1 300 C for 100 h or 200 h, and that for silicon

carbides and advanced grades of silicon nitrides is 1 400 C for 100 h or 200 h. Such conditions provide a means of readily
distinguishing performances of similar materials.
©
4 ISO 2003 – All rights reserved

---------------------- Page: 14 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
NOTE 2 The oxidation behaviour of other non-oxide ceramics (such as borides, carbides, nitrides and silicides) varies
widely, and the test conditions should be selected on the basis of preliminary experiments. Test results should be
documented carefully in the report.
6.5 Measurements of mass and dimensional changes
Weigh the test pieces individually with their adherent oxidation products to the nearest 0,05 mg. Weigh any
loose spallation products separately. If spallation products from individual test cannot be weighed separately,
weigh them altogether. If appropriate, remeasure the external dimensions of the test pieces for the
determination of dimensional changes.
NOTE It is generally not realistically possible to measure spallation that is adherent to or reacting with furnace or test piece
support parts.
6.6 Measurements of flexural strength
Measure the flexural strength of the oxidized and the control test pieces in accordance with Clause 7 of
ISO 14704:2000. If the nature of the oxidized surface has to be changed in order to undertake the strength tests
this must be mentioned in the report.
NOTE 1 A fully articulating fixture should be used for flexural strength measurements of the oxidized specimens because
they may not meet the parallelism requirements given in ISO 14704 for use of a semi-articulating fixture.
NOTE 2 A semi-articulating fixture may be used if the parallelism requirements are satisfied. One surface of an as-oxidized
part may be machined to help minimize twisting or warping effects. The machined surface should be placed in contact with
the inner bearings (specimen compression side) during testing.
6.7 Particular features
Record any particular features associated with the condition of the oxidized surfaces, the appearance of
fractured cross-sections, etc.
NOTE Phase analysis of the oxide layer using an X-ray diffraction technique and microstructure observation of the oxide
layer in the cross section using scanning electron microscopy may be useful characterization methods.
7 Calculations
7.1 Flexural strength
If flexural strength has been measured, compute the flexural strength using the relevant formula for the jig type,
whether three-point or four-point bending, as in ISO 14704. Compute the average strength and standard
deviation for the control batch and for each oxidation condition. Report the outer and inner spans and whether
semi-articulating or fully articulating.
7.2 Mass change
If the mass change is required, compute the mass change per unit nominal surface area of test piece (C) in
accordance with the formula:
W −W
f i
C= (1)
A
©
ISO 2003 – All rights reserved 5

---------------------- Page: 15 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
where
W and W are final and initial mass of test piece respectively, expressed in grams;
f i
A is the nominal external surface area of test piece based on initial dimensions expressed in
square meters.
Compute the average result and the standard deviation for each oxidation condition employed.
n

C
i
i=1
C= (2)
n


2
(C −C)
i
S= (3)
n− 1
where
C is the average value;
n is the total number of specimens;
S is the standard deviation.
NOTE If the material is porous and has oxidized internally, it may be more appropriate to express the oxidation behaviour
as a mass change per unit volume, or as a percentage mass change. In both cases, these calculations will be averages for
the test piece, and will not reflect spatial variations in oxidation behaviour within the test piece.
7.3 Nominal dimensional change
If the change in dimensions is required, compute the absolute changes in the linear dimensions bh and , and
express them in mm:
∆h=h −h (4)
f i
∆b=b −b (5)
f i
where
h is the final test piece thickness, expressed in millimetres;
f
h is the initial test piece thickness, expressed in millimetres;
i
b is the final test piece width, expressed in millimetres;
f
b is the initial test piece width, expressed in millimetres.
i
Compute the average absolute change and the standard deviation for each oxidation condition.
n

∆h
i
i=1
∆h= (6)
n


n


2
� (∆h −∆h)
i

i=1
S= (7)
n− 1
©
6 ISO 2003 – All rights reserved

---------------------- Page: 16 ----------------------
SIST EN ISO 20509:2023
ISO 20509:2003(E)
n

∆b
i
i=1
∆b= (8)
n


n


2
� (∆b −∆b)
i

i=1
S= (9)
n− 1
where
∆h and ∆b is the average value;
n is total number of specimens;
S is standard deviation.
8 Test report
The results of oxidation tests shall include the following:
a) name and address of the testing establishment;
b) date of the test, a unique identification of the report and of each page, customer name and address, and
signatory of the report;
c) reference to this International Standard, i.e., determined in accordance with ISO 20509;
d) description of the test apparatus used, including details of the type of oxidation furnace, the materials used
in construction of the hot-zone, test piece support system used, the materials in direct contact with the test
pieces, the heating and cooling rates used, details of the rate of supply of test gas, its composition and
moisture content, if appropriate, the type of flexural test, etc.;
e) description of the test material (manufacturer, type, batch number, date of manufacture, etc.);
f) description of the details of the test piece preparation, including nominal dimensions and surface finishing
procedures, cleaning procedures, strength test conditions, in accordance with the provisions of ISO 14704;
g) individual determinations of test pieces mass before and after testing, the computed mass change for each
test piece at each test condition, the mean and stan
...

SLOVENSKI STANDARD
oSIST prEN ISO 20509:2023
01-januar-2023
Fina keramika (sodobna keramika, sodobna tehnična keramika) - Ugotavljanje
oksidacijske odpornosti neoksidne monolitne keramike (ISO 20509:2003)
Fine ceramics (advanced ceramics, advanced technical ceramics) - Determination of
oxidation resistance of non-oxide monolithic ceramics (ISO 20509:2003)
Hochleistungskeramik - Bestimmung der Beständigkeit von nichtoxidischer
monolithischer Keramik gegen Oxidation (ISO 20509:2003)
Céramiques techniques - Détermination de la résistance à l'oxydation des céramiques
monolithiques (ISO 20509:2003)
Ta slovenski standard je istoveten z: prEN ISO 20509
ICS:
81.060.30 Sodobna keramika Advanced ceramics
oSIST prEN ISO 20509:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN ISO 20509:2023

---------------------- Page: 2 ----------------------
oSIST prEN ISO 20509:2023
INTERNATIONAL ISO
STANDARD 20509
First edition
2003-12-01
Fine ceramics (advanced ceramics,
advanced technical ceramics) —
Determination of oxidation resistance of
non-oxide monolithic ceramics
Céramiques techniques — Détermination de la résistance à l'oxydation
des céramiques monolithiques

Reference number
ISO 20509:2003(E)
©
ISO 2003

---------------------- Page: 3 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2003 – All rights reserved

---------------------- Page: 4 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Apparatus . 2
5 Test pieces . 3
6 Test procedure . 3
7 Calculations . 5
8 Test report . 7
Annex A (informative) Useful information . 8
Annex B (informative) Interlaboratory evaluation of the test method . 9
Bibliography . 11
©
ISO 2003 – All rights reserved iii

---------------------- Page: 5 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 20509 was prepared by Technical Committee ISO/TC 206, Fine ceramics.
©
iv ISO 2003 – All rights reserved

---------------------- Page: 6 ----------------------
oSIST prEN ISO 20509:2023
INTERNATIONAL STANDARD ISO 20509:2003(E)
Fine ceramics (advanced ceramics, advanced technical
ceramics) — Determination of oxidation resistance of non-oxide
monolithic ceramics
1Scope
This International Standard describes the method of test for determining the oxidation resistance of non-oxide
1)
monolithic ceramics, such as silicon nitride, Sialon and silicon carbide at high temperatures. This International
Standard is intended to provide an assessment of the mass and dimensional changes of test pieces following
oxidation at high temperature in an oxidizing atmosphere, and to assess whether oxidation has a significant
effect on the subsequent strength. This test method may be used for materials development, quality control,
characterization, and design data generation purposes.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3611:1978, Micrometer callipers for external measurement
ISO 6906:1984, Vernier callipers reading to 0,02 mm
2)
ISO 7500-1:— , Metallic materials — Verification of static uniaxial testing machines — Part1:
Tension/compression testing machines — Verification and calibration of the force-measuring system
ISO 14704:2000, Fine ceramics (advanced ceramics, advanced technical ceramics) — Test method for flexural
strength of monolithic ceramics at room temperature
IEC 60584-1:1995, Thermocouples — Part 1: Reference tables
IEC 60584-2:1989, Thermocouples — Part 2: Tolerances
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
oxidation resistance
resistance against oxidation of a non-oxide ceramic material due to reaction with oxygen in the surrounding
atmosphere, including any internal reactions as a result of the presence of open porosity or of diffusion of ions
to or from the ceramic surface
3.2
flexural strength
maximum nominal stress at fracture of a specified elastic beam loaded in bending
1) Sometimes written SiAlON is the acronym for a ceramic that contains silicon, aluminium, oxygen and nitrogen.
2) To be published. (Revision of ISO 7500-1:1999)
©
ISO 2003 – All rights reserved 1

---------------------- Page: 7 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
4 Apparatus
4.1 High temperature furnace, e.g. any suitable air atmosphere furnace with a nominal temperature

capability of at least 1 500 C.
The furnace chamber shall have an inlet for a sufficient supply of oxidation gas to ensure that the atmosphere
does not stagnate and become oxygen deficient. The temperature shall be capable of being raised to that
◦ −1 ◦
required for testing at a minimum of 5 C min , of being controlled to better than ± 5 C at all oxidation
◦ −1 ◦
temperatures, and of being cooled at more than 5 C min to below 800 C. Before commencing oxidation
tests, the furnace chamber shall be baked out using the same atmosphere as proposed for testing and at a
temperature at least as high as the intended oxidation test temperature for a period of at least 10 h in order to
remove contaminants.
4.2 Support or supporting stand, for oxidation tests.
The test pieces shall be supported using techniques that minimize contact area, degree of adhesion and extent
of reaction with the test piece (see Figure 1). Preferably this should be done using point or line contact only. Any
contact of the supports with the regions of the test piece surfaces to be subjected later to loading roller contact
in flexural strength testing shall be avoided. Examples of suitable support methods include the use of a block
with drilled holes no more than 3mm deep such that the test pieces can stand near vertically with a minimum of
end and edge contact. The samples can also be situated on horizontal supports on rollers of silicon carbide or
mullite, on small diameter platinum wires, either suspended or resting on a clean non-reactive ceramic surface,
or on semi-rings which can be cut from ceramic tubes (alumina, mullite, silicon carbide, or silicon nitride).
a) b) c) d)
a) a refractory block with appropriate-sized holes in it, suitable for muffle furnace;
b) a support system based on tubes and discs with holes, suitable for vertical tube furnace;
c) a pair of supported parallel rods spaced near the ends of the test-pieces and with an adequate gap underneath,
suitable for a muffle furnace;
d) a test-piece supported by its ends on a ceramic semi-ring.
Figure 1 — Examples of support systems for flexural strength test pieces
NOTE 1 It may be necessary to perform some preliminary assessments to ensure that the supporting material is
sufficiently non-reactive as to not significantly contribute to the mass changes in the sample.
NOTE 2 Candidate materials for supporting test pieces include silicon carbide, mullite, platinum wire and alumina. Silicon
carbide and mullite may be the most suitable materials. Alumina may react with test pieces, and platinum is inappropriate for
non-oxide ceramics containing free metallic species, such as silicon carbide containing silicon.
◦ ◦
4.3 Oven, capable of maintaining a temperature of 105 C to 120 C.
4.4 Testing machine for flexural strength, capable of applying a uniform crosshead speed. The testing
machine shall be in accordance with ISO 7500-1:— Class 1 with an accuracy of 1% of indicated load at
fracture.
©
2 ISO 2003 – All rights reserved

---------------------- Page: 8 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
4.5 Testing fixture for flexural strength, of three- or four-point flexure configuration in accordance with 5.2
of ISO 14704:2000. The recommended fixture is fully articulated and of the four-point-1/4 point configuration
with the two outer bearings at a distance of 40 mm. The corresponding total length of test piece is � 45 mm.
4.6 Micrometer, such as shown in ISO 3611:1978 but with a resolution of 0,002 mm for measuring the test
piece dimensions. The micrometer shall have flat anvil faces such as shown in ISO 3611:1978. The micrometer
shall not have a ball tip or sharp tip since these might damage the test piece. Alternative dimension measuring
instruments may be used provided that they have a resolution of or finer.
0,002 mm
4.7 Vernier calliper, with a resolution of 0,05 mm or finer for measuring the length of the test piece, in
accordance with ISO 6906. Alternative dimension measuring instruments may be used provided that they have
a resolution of 0,05 mm or finer.
4.8 Balance, capable of weighing up to 200 g with a sensitivity of at least 0,05 mg.
4.9 Thermocouple, of type R or type S in accordance with IEC 60584-2, permitting the use of the calibration
table given in IEC 60584-1.
5 Test pieces
If the strength changes are to be determined, flexural strength test pieces in accordance with Clause 6 of
ISO14704:2000 shall be used. The standard test specimens shall have cross-sectional dimensions of
3,00 mm ± 0,20 mm thickness and 4,00 mm ± 0,20 mm width. The length shall be more than 35 mm for
30 mm test fixtures or more than 45 mm for 40 mm test fixtures. All the surfaces shall be machined, and edges
shall be rounded or chamfered. Any machining procedure and the surface quality of the test pieces shall be
reported. The minimum number of test pieces shall be 10 for each oxidation condition to be tested, plus 10 test
pieces as an unoxidized control. Means shall be taken to identify individually, similar test pieces, but shall not be
marked or scribed in a way that might affect the result of the test. If strength changes are not to be determined,
any test piece, in terms of size and shape, may be used.
Test pieces shall be clean and free from preparation residues and contamination due to handling which can
influence the initial mass measurement and/or the oxidation rate. The test-piece cleaning procedure shall be
stated in the report.
For materials with no significant open porosity and contaminated by handling, and/or by mounting or machining
coolant residues, submerge the test-pieces in ethanol in an ultrasonic bath and agitate for at least 10 min. In
order to avoid damage, test pieces shall not be allowed to contact either each other or a hard surface during this
operation. For materials containing open porosity, internally entrained organic residues can be removed only by
heating in air. The maximum temperature to which this should be done will depend on the material type, but
◦ ◦
typically a temperature of 500 C to 600C1 for a least h is required to oxidize carbonaceous residues.

Material with intentionally present free carbon shall be treated at a maximum temperature of 350 C to avoid
oxidation.
6 Test procedure
6.1 Measurements of dimensions and mass of specimens
For flexural strength test pieces, measure the width, bh, and thickness, , of each test piece at several places
using the micrometer (4.5) with a resolution of 0,002 mm. Measure the overall length, L , with the vernier
T
callipers (4.6) with a resolution of 0,05 mm. For other shapes of test piece, measure relevant dimensions at
several different places (e.g. diameter and thickness of a disc). Wash and degrease the test pieces (see
◦ ◦
Clause 5). Place in the oven (4.3) and heat to a temperature of 105 C to 120 C until their mass is constant.
Remove and store in a desiccator. When cooled to room temperature, weigh each test piece to the nearest
0,05 mg using the balance (4.7). Store in the desiccator until tested.
©
ISO 2003 – All rights reserved 3

---------------------- Page: 9 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
6.2 Baking out in the oxidation furnace
Unless used for a similar measurement immediately prior to the test, pre-condition the furnace (4.1) and the test
piece support system (4.2) at a temperature similar to or greater than that intended for the oxidation test under
the intended flowing gas atmosphere. The maximum temperature shall be maintained for at least 10 h.
6.3 Oxidation test
6.3.1 Materials with high oxidation resistance
6.3.1.1 Place the test pieces on their supports (4.2) in the centre of the hot zone of the furnace (4.1) ensuring
sufficient space between test pieces and their supports for adequate circulation of air. Ensure that contact with
supports is minimized (see Figure 1). The contacts shall always be at locations outside the outer span used for
the flexural test. The minimum spacing between test pieces as well as that between a test piece and furnace
furniture shall be 5mm.
NOTE 1 It is preferred that each batch of a least 10 test pieces per oxidation condition is exposed at the same time in the
same facility. Separated exposure at separate times may result in slightly different results.
NOTE 2 The minimum spacing between components or test-pieces under test should be increased with increasing
component or test-piece size to ensure unimpeded gas flow between neighbouring oxidizing surfaces.
6.3.1.2 Position a type R or type S thermocouple (4.8) in accordance with IEC 60584-2 adjacent to the test
pieces for the purposes of monitoring test piece temperature during the oxidation period. Close the furnace.
6.3.1.3 Supply the oxidizing gas at a rate sufficient to provide atmosphere circulation within the furnace cavity
and around the test pieces such that stagnation and oxygen depletion is avoided, but not at such a rate that
results in inhomogeneous or fluctuating furnace temperature. For testing in normal air, a natural flow of the air
through the furnace cavity shall be facilitated. Note that a gas flow rate is recommended of between typically 0,5
and 50 volume changes per hour, but not less than 0,1 changes per hour.
6.3.1.4 Heat the furnace to the test temperature as indicated by the measuring thermocouple adjacent to the

test pieces. Maintain this temperature to within 5 C for the required oxidation period. Cool the furnace at the
maximum rate of cooling of the furnace and carefully remove the test pieces from their supports and place in a
desiccator. To avoid contamination, do not touch the test pieces with naked fingers until after the final weighing.
Ensure that loose deposits on the test piece surface are retained intact as far as possible.
6.3.2 Materials with low oxidation resistance
The procedure outlined in 6.3.1 can be also used in the testing of materials with low oxidation resistance or
those producing low melting oxidation products, such as B O formed during the oxidation of borides. Some
2 3
modifications are suggested for the samples that react significantly with or stick to the support fixture. In these
cases, it is recommended to use a system supporting each individual sample, such as the semi-rings [Figure 1
d)], so that the sample and the support can be weighed together before and after the test.
Additionally, the samples should be inserted into a furnace, preheated to the test temperature, and then air-
quenched after the test to retain the high temperature condition of the surface layer for room temperature
microscopic evaluation. Nevertheless, the quenching of the samples can affect the strength as a result of
thermal shock.
6.4 Selecting test conditions
Test conditions (temperature, atmosphere, duration, etc.) shall be selected according to the technical
requirements for undertaking the test and on agreement between parties.

NOTE 1 The test condition recommended for silicon nitrides and Sialons is 1 300 C for 100 h or 200 h, and that for silicon

carbides and advanced grades of silicon nitrides is 1 400 C for 100 h or 200 h. Such conditions provide a means of readily
distinguishing performances of similar materials.
©
4 ISO 2003 – All rights reserved

---------------------- Page: 10 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
NOTE 2 The oxidation behaviour of other non-oxide ceramics (such as borides, carbides, nitrides and silicides) varies
widely, and the test conditions should be selected on the basis of preliminary experiments. Test results should be
documented carefully in the report.
6.5 Measurements of mass and dimensional changes
Weigh the test pieces individually with their adherent oxidation products to the nearest 0,05 mg. Weigh any
loose spallation products separately. If spallation products from individual test cannot be weighed separately,
weigh them altogether. If appropriate, remeasure the external dimensions of the test pieces for the
determination of dimensional changes.
NOTE It is generally not realistically possible to measure spallation that is adherent to or reacting with furnace or test piece
support parts.
6.6 Measurements of flexural strength
Measure the flexural strength of the oxidized and the control test pieces in accordance with Clause 7 of
ISO 14704:2000. If the nature of the oxidized surface has to be changed in order to undertake the strength tests
this must be mentioned in the report.
NOTE 1 A fully articulating fixture should be used for flexural strength measurements of the oxidized specimens because
they may not meet the parallelism requirements given in ISO 14704 for use of a semi-articulating fixture.
NOTE 2 A semi-articulating fixture may be used if the parallelism requirements are satisfied. One surface of an as-oxidized
part may be machined to help minimize twisting or warping effects. The machined surface should be placed in contact with
the inner bearings (specimen compression side) during testing.
6.7 Particular features
Record any particular features associated with the condition of the oxidized surfaces, the appearance of
fractured cross-sections, etc.
NOTE Phase analysis of the oxide layer using an X-ray diffraction technique and microstructure observation of the oxide
layer in the cross section using scanning electron microscopy may be useful characterization methods.
7 Calculations
7.1 Flexural strength
If flexural strength has been measured, compute the flexural strength using the relevant formula for the jig type,
whether three-point or four-point bending, as in ISO 14704. Compute the average strength and standard
deviation for the control batch and for each oxidation condition. Report the outer and inner spans and whether
semi-articulating or fully articulating.
7.2 Mass change
If the mass change is required, compute the mass change per unit nominal surface area of test piece (C) in
accordance with the formula:
W −W
f i
C= (1)
A
©
ISO 2003 – All rights reserved 5

---------------------- Page: 11 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
where
W and W are final and initial mass of test piece respectively, expressed in grams;
f i
A is the nominal external surface area of test piece based on initial dimensions expressed in
square meters.
Compute the average result and the standard deviation for each oxidation condition employed.
n

C
i
i=1
C= (2)
n


2
(C −C)
i
S= (3)
n− 1
where
C is the average value;
n is the total number of specimens;
S is the standard deviation.
NOTE If the material is porous and has oxidized internally, it may be more appropriate to express the oxidation behaviour
as a mass change per unit volume, or as a percentage mass change. In both cases, these calculations will be averages for
the test piece, and will not reflect spatial variations in oxidation behaviour within the test piece.
7.3 Nominal dimensional change
If the change in dimensions is required, compute the absolute changes in the linear dimensions bh and , and
express them in mm:
∆h=h −h (4)
f i
∆b=b −b (5)
f i
where
h is the final test piece thickness, expressed in millimetres;
f
h is the initial test piece thickness, expressed in millimetres;
i
b is the final test piece width, expressed in millimetres;
f
b is the initial test piece width, expressed in millimetres.
i
Compute the average absolute change and the standard deviation for each oxidation condition.
n

∆h
i
i=1
∆h= (6)
n


n


2
� (∆h −∆h)
i

i=1
S= (7)
n− 1
©
6 ISO 2003 – All rights reserved

---------------------- Page: 12 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
n

∆b
i
i=1
∆b= (8)
n


n


2
� (∆b −∆b)
i

i=1
S= (9)
n− 1
where
∆h and ∆b is the average value;
n is total number of specimens;
S is standard deviation.
8 Test report
The results of oxidation tests shall include the following:
a) name and address of the testing establishment;
b) date of the test, a unique identification of the report and of each page, customer name and address, and
signatory of the report;
c) reference to this International Standard, i.e., determined in accordance with ISO 20509;
d) description of the test apparatus used, including details of the type of oxidation furnace, the materials used
in construction of the hot-zone, test piece support system used, the materials in direct contact with the test
pieces, the heating and cooling rates used, details of the rate of supply of test gas, its composition and
moisture content, if appropriate, the type of flexural test, etc.;
e) description of the test material (manufacturer, type, batch number, date of manufacture, etc.);
f) description of the details of the test piece preparation, including nominal dimensions and surface finishing
procedures, cleaning procedures, strength test conditions, in accordance with the provisions of ISO 14704;
g) individual determinations of test pieces mass before and after testing, the computed mass change for each
test piece at each test condition, the mean and standard deviation for each test condition, expressed in
gram per square metre;
h) mass of the collected spallation products, expressed in grams, and the average spallation mass per unit
surface area of test piece;
i) individual fracture load in strength tests, expressed in newtons, and computed nominal fracture stress
expressed in megapascals (or meganewtons per square metre) for each test piece at each test condition
including unoxidized control test pieces, the mean results and standard deviations for each condition;
j) individual results of mean test piece dimensions before and after testing, and the computed size changes at
each test condition, the mean results and standard deviation;
k) any comments about the test or the results, including observations on the surface condition of the test
pieces following oxidation and the oxidation layer, such as scanning electron micrographs of oxidized layer,
phases in the oxidized layer and thickness of oxidized layer, on whether the surface condition was modified
in order to conduct strength tests, on the appearance of fracture surfaces, and on the likely interference
caused by oxide scale spalling or adhesion to the support system.
©
ISO 2003 – All rights reserved 7

---------------------- Page: 13 ----------------------
oSIST prEN ISO 20509:2023
ISO 20509:2003(E)
Annex A
(informative)
Useful information
A.1 General
Evaluation of oxidation resistance is important when non-oxide ceramics are used in oxidizing environments at
high temperatures. Oxidation in non-oxide ceramics usually occurs as a result of substitution of non-oxygen
non-metallic species by oxygen, which develops a surface skin of altered composition. Mass change is a
common measure to evaluate oxidation resistance. Another measure of oxidation resistance is the strength
variation, since the strength-determining flaw can be altered by the generation of oxidation-induced flaws and
crack healing. When non-oxide ceramics are used at high temperatures as structural components, oxidation
resistance is often evaluated via mass and strength variations.
A.2 Oxidation mechanisms and the formation of oxides
Oxidation of non-oxide ceramics usually occurs when oxygen in air reacts with the ceramic substance. Once the
reaction occurs, an oxide layer is often formed on the surface. If the layer is protective, further oxidation is
retarded and the oxidation rate is governed by the diffusion rate in the oxidation layer. In this case, the oxidation
rate of mass gain should obey a parabolic law and a dense oxide layer is formed on the surface [1]-[12].
However, when the oxide layer is not protective, the reaction at the original surface of the material determines
the rate, and the reaction rate exhibits a linear dependence over time [11]-[14]. In some cases, the oxide
products may not adhere to the sample, but tend to flake off as a result of disruptive forces caused by volume
changes, phase changes and thermal expansion mismatches [13], [14]. For materials with open porosity, such
as reaction-bonded silicon nitride and some silicon carbides, oxidation will generally occur through continuous
pores that are initially surface connected, although these may become blocked as oxidation proceeds [15]. As a
result of oxidation of silicon nitride and silicon carbide, the major phase formed on the surface is amorphous
silica that contains the ions originally doped in the bulk [5], [16]. The presence of water vapour influences the
oxidation rate [6], [10], [17], and can enhance the crystallization of the oxide layer [18].
Oxidation kinetics depend not only on the materials but also the oxidation conditions. The oxidation rates of
refractory carbides tend to follow a parabolic rate law under conditions of high oxygen partial pressure and low
oxidation temperature, and a linear dependence is found in high temperature oxidation [11]. La O -Y O
2 3 2 3

doped-silicon nitride obeys parabolic oxidation dependence at temperatures < 1 450 C for short exposure
periods, while linear oxidation dependence governs at higher temperatures for longer exposures [12]. A porous
(21,5 % porosity)
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.