SIST EN 24937:1997
(Main)Steel and iron - Determination of chromium content - Potentiometric or visual method (ISO 4937:1986)
Steel and iron - Determination of chromium content - Potentiometric or visual method (ISO 4937:1986)
Quality. Rationalization.
Stahl und Eisen - Bestimmung des Chromgehalts - Potentiometrische oder visuelle Methode (ISO 4937:1986)
Qualitaet. Rationalisierung.
Aciers et fontes - Détermination de la teneur en chrome - Méthode potentiométrique ou visuelle (ISO 4937:1986)
Qualité. Rationalisation.
Jeklo in železo - Določevanje kroma - Potenciometrična ali vizualna metoda (ISO 4937:1996)
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Stahl und Eisen - Bestimmung des Chromgehalts - Potentiometrische oder visuelle Methode (ISO 4937:1986)Aciers et fontes - Détermination de la teneur en chrome - Méthode potentiométrique ou visuelle (ISO 4937:1986)Steel and iron - Determination of chromium content - Potentiometric or visual method (ISO 4937:1986)77.080.01Železne kovine na splošnoFerrous metals in generalICS:Ta slovenski standard je istoveten z:EN 24937:1990SIST EN 24937:1997en01-december-1997SIST EN 24937:1997SLOVENSKI
STANDARD
SIST EN 24937:1997
SIST EN 24937:1997
SIST EN 24937:1997
G - International Standard INTERNATIONAL ORGANIZATION FOR STANDARDIZATION.ME~YHAPO~HAfl OPrAHM3Al&lR fl0 CTAH~APTM3ALWWORGANISATION INTERNATIONALE DE NORMALISATION Steel and iron - Determination of chromium content - Potentiometric or visual titration method Aciers et fontes - Dosage du chrome - M&hode par titrage potentiome trique ou visuel First edition - 1986-12-15 UDC 629.13/.14 : 543.24/.25 : 546.76 Ref. No. ISO 4937-1986 (E) Descriptors : steels, iron, Chemical analysis, determination of content, chromium, potentiometric methods, volumetric analysis. F; % 0 v) Price based on 8 pages SIST EN 24937:1997
Foreword ISQ (the International Organization for Standardization) is a worldwide federation of national Standards bodies (ISO member bedies). The work of preparing International Standards is normally carried out through ISO technical committees. Esch member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, govern- mental and non-governmental, in liaison with ISO, also take part in the work. Draft International Standards adopted by the technical committees are circulated to the member bodies for approval before their acceptance as International Standards by the ISQ Council. They are approved in accordance with ISO procedures requiring at least 75 % approval by the member bodies voting. International Standard ISO 4937 was prepared by Technical Committee ISO/TC 17, S teel. Users should note that all International Standards undergo revision from time to time and that any reference made herein to any other International Standard implies its latest edition, unless othervvise stated. 0 International Organization for Standardkation, 1986 Printed in Switzerland SIST EN 24937:1997
INTERNATIONAL STANDARD ISO 49374986 IE) Steel and iron - Determination of chromium content - Potentiometric or visual titration method 1 Scope and field of application This International Standard specifies a method for the deter- mination of chromium in steel and iron by potentiometric or visual titration. The method is applicable to chromium contents between 0,25 and 35 % (mlm). If vanadium is present, the visual titration is applicable only to test portions containing less than 3 mg of vanadium. 2 References ISO 377, Wrought steel - Selection and preparation of samples and test pieces. ISO 385/1, Laboratory gfassware - Burettes - Part I: General requiremen ts. ISO 648, Laboratory glassware - One-mark pipettes. I S 0 1042, L abora tot-y glassware - One-mark volume tric flasks. ISO 5725, Precision of test methods - Determination of repea tability and reproducibifity b y in ter-labora tory tes ts. 3 Principle Dissolution of a test Portion with appropriate acids. Oxidation of chromium in an acid medium to chromium(Vl) by ammonium peroxydisulfate in the presence of silver sulfate. Reduction of manganese(VII) by hydrochloric acid. Reduction of chromium(VIf by ammonium iron(ll) sulfate stan- dard solution. In the case of potentiometric detection, determination of the equivalence Point by measurement of the potential Variation when the ammonium iron(ll) sulfate Standard Solution is being added. In the case of visual detection, titration of the excess am- monium iron(ll) sulfate by potassium permanganate Standard Solution which also acts as the indicator. 4 Reagents During the analysis, unless otherwise stated, use only reagents of recognized analytical grade and only distilled water or water of equivalent purity, free from oxidizing or reducing activity. 4.1 Urea. 4.2 Perchlorit acid, Q approximately 1,67 g/ml. 4.3 Hydrofluoric acid, Q approximately l,l5 g/mI. 4.4 Orthophosphoric acid, Q approximately 1,70 g/ml. 4.5 Nitrit acid, Q approximately 140 g/ml. 4.6 Hydrochlorit acid, Q approximately 1,19 g/ml, diluted 1 + 1. 4.7 Hydrochlorit acid, Q approximately 1,19 g/ml, diluted 1 + 10. 4.8 Sulfuric acid, Q approximately 1,84 g/ml, diluted 1 + 1. 4.9 Sulfuric acid, Q approximately IJ34 g/ml, diluted 1 + 5. 4.10 Sulfuric acid, ,Q approximately 1,84 g/ml, diluted 1 + 19. 4.11 Silver sulfate, 5 g/l Solution. 4.12 Ammonium peroxydisulfate [(NH&S208], 500 g/l Solution. Prepare this solution immediately before use. 4.13 Manganese sulfate [MnS0,*H201, 4 g/i Solution. 4.14 Manganese sulfate [MnS04~H201, 100 g/l Solution. 4.15 Potassium permanganate, 5 g/l solution. 4.16 Sodium nitrite, 3 g/l Solution. Prepare this solution immediately before use. 4.17 Sulfamic acid (NH2S03H), 100 g/l Solution. This Solution remains stable for one week only. 1 SIST EN 24937:1997
ISO 4937-1986 (El 4.18 Potassium permanganate, Standard Solution. 439.2 Potentiometric Standardkation (to be carried out just before use) of the Solution 438.1 Preparation of the Solution Take 30,O ml of the potassium dichromate Standard reference Solution (4.20), transfer to a 600 ml beaker, add 45 ml of sulfuric acid (4.9) and make up to about 400 ml with water. Dissolve 3,2 g of potassium permanganate in 1 000 ml of water. After storage in complete darkness for 2 weeks, filter through a thick fritted filter without washing. Keep the Solution in a col- oured glass bottle and avoid contact with organic matter. Titrate according to the conditions specified in 7.3.3.1. The corresponding concentration (c,) of ammonium iron(ll) sulfate Solution (4.19.1), expressed in milligrams of chromium per millilitre, is given by the formula 4.18.2 Standardkation of the Solution Boil 250 ml of sulfuric acid (4.10) in a 600 ml beaker for 10 min and allow to cool. Weigh, to the nearest 0,000 1 g, 0,300 0 g of sodium oxalate I(COONa)2] previously dried at 105 OC and cooled in a desiccator. Dissolve the salt in boiled sulfuric acid (4.10). Add 39 to 40 ml of potassium permanganate solution (4.18.1) at a rate of 25 to 35 ml/min, stirring gently. The violet colour of the permanganate will disappear in approximately 45 s. Heat to 70 to 75 OC and complete the titration. 30,o x 1,733 Cl = ---- V2 where V2 is the volume, in millilitres, of ammonium iron( II) sulfate Solution (4.19 .l) used for the standardization ; Towards the end, titrate very slowly and become colourless before addi ng the next allow each drop to 30,O is the volume, in millilitres, of the potassium dichromate Standard reference Solution (4.20) taken for the standardization ; To determine the blank test, titrate 250 ml of sul (4.1 0), as described above, concurren tly. furic acid 1,733 is the mass, in milligrams, of chromium contained in 1 ml of the potassium dichromate Standard reference solu- tion (4.20). The concentration (c2) of the potassium permanganate stan- dard Solution, expressed as milligrams of chromium per millilitre, is given by the formula 4.193 out just Visual before stan use) ization of the tion (to be carried 300,o x 1,733 c2 = 6,700 x t V, - Vo, Take 25,0 ml of ammonium irontll) sulfate Solution (4.19.1) and add 325 ml of sulfuric acid (4.10). Titrate using the potassium permanganate Standard Solution (4.18) until a slight violet col- our persists. where VI is the volume, in millilitres, of potassiu m permangana Solution (4.18.1) used for titrating sodium oxalate; te To determine the blank test, titrate a mixture of 25 ml of water and 325 ml of sulfuric acid (4.10) using the potassium per- manganate Standard Solution (4.18). V. is the volume, in millilitres, of potassium permanganate Solution (4.18.1) used for titrating the blank test of sulfuric acid (4.10) ; 6,700 is the molar mass sf sodium oxalate divided by 20; 1,733 is the mass, in milligrams, of chromium(Vl) con- tained in 1 ml of the potassium dichromate Standard reference Solution (4.20) ; 300,O is the mass, in milligrams, of sodium oxalate weighed. V3 - Fl c‘, = c2 x ~ 25,0 where c2 is the concentration of the potassium permanganate Standard Solution (4.18), expressed as milligrams of chromium per millilitre; 4.19 Ammonium iron(ll) sulfate [Fe(NH4)2(S04)2~6H201, Standard Solution in Suffurie acid medium. V3 is the volume, in millilitres, of the potassium per- manganate Standard Solution (4.18) used to oxidize 25 ml of ammonium iron(ll) sulfate solution (4.19.1) ; 1 m! of this Solution corresponds to about 2 mg of chromium. V. is the volume, in millilitres, of the potassium per- manganate Standard solution (4.18) used for titrating the blank test of sulfuric acid (4.10) ; 4.19.1 Preparation of the Solution Dissolve 46 g of ammonium iron(ll) sulfate hexahydrate in about 500 ml of water, add 110 ml of sulfuric acid (4.8), cool, dilute to 1 000 ml and mix. 25,0 is the volume, in millilitres, of ammonium iron(ll) sulfate Solution (4.19.1) used for the standardization. 2 SIST EN 24937:1997
ISO4937-1986 (El 4.20 Potassium dichromate, Standard reference solution. 7.3 Determination Weigh, to the nearest 0,000 1 g, 4,903 1 g of potassium dichromate previously dried at 150 OC to constant mass and cooled in a desiccator. 7.3.1 Preparation of the test solution 7.3.1.1 Unalloyed steel and iron Dissolve in water, transfer quantitatively to a 1 000 ml one- mark volumetric flask, dilute to the mark and mix. Place the test Portion (7.‘l) in a 600 ml beaker, add 60 ml of sulfuric acid (4.9) and 10 ml of orthophosphoric acid (4.4), and heat to dissolve, then oxidize with 15 ml of nitric acid (4.5). Heat until dense white fumes are given off, cool and then add 100 ml of water. 1 ml of this Standard reference solution contains 1,733 mg of Cr. To accelerate the dissolution of a test Portion which has a high Silicon content, a few drops of hydrofluoric acid (4.3) may be added (see note 1). 5 Apparatus Ordinary laboratory apparatus (see the note) and 7.3.1.2 Chromium and/or nicke1 alloyed steel and iron 5.1 Potentiometric titration device, which permits a dif- ference in potential to be measured with platinum-saturared calomel electrodes. Place the test Portion (7.1) in a 600 ml beaker, add 25 ml of hydrochloric acid (4.6) and heat to dissolve, then oxidize with 15 ml of nitric acid (4.5). If dissolution proves to be particularly difficult, add 1 to 2 ml of hydrofluoric acid (4.3). Then add 20 ml of sulfuric acid (4.8) and 10 ml of orthophosphoric acid (4.4), and heat until dense white fumes appear. NUTE - All volumetric glassware shail be class A, in accordance with ISO 385/1, ISO 648 or ISO 1042 as appropriate. After cooling, add a further 15 ml of nitric acid (4.5) to the fum- ing solution, if necessary making further additions, until the carbides have completely decomposed. Continue fuming to remove completely oxides of nitrogen then cool and add 100 ml of water (see note 1). 6 Sampling Carry out sampling in accordance with ISO 377 or the appropriate national Standards for iron. 7.3.1.3 Steel containing tungsten Place the test Portion (7.1) in a 600 ml beaker, add 25 ml of hydrochloric acid (4.6) then 20 ml of sulfuric acid (4.8) and 10 ml of orthophosphoric acid (4.4) and heat until efferves- cence has ceased. lf dissolution proves to be particularly dif- ficult add 1 to 2 ml of hydrofluoric acid (4.3). Oxidize with 15 ml of nitric acid (4.5) then heat until dense white fumes appear. 7 Procedure WARNING : Perchlorit acid vapour may Cause explosions in the presence of ammonia, nitrous fumes or organic material in general. After cooling, add a further 15 ml of
...