oSIST prEN 16087-1:2025
(Main)Soil improvers and growing media - Determination of the aerobic biological degradation rate of organic matter - Part 1: Oxygen uptake rate (OUR)
- Abstract
This document describes a method to determine the stability of materials (e.g. compost, digestate) used as components (ingredients) in growing media, soil improvers and organic fertilizers by measuring the oxygen uptake rate (OUR). It can also be used for growing media and soil improvers. The oxygen uptake rate is a direct parameter for the degradation rate of biodegradable organic matter that is being broken down within a specified time period. The method is not suitable for materials with a content of particle sizes > 20 mm exceeding 20 % by volume.
NOTE 1 The relation between the degradation rate and the oxygen uptake rate under the same conditions is depending on the type of material, for example by the C/N ratio. So it is important for the interpretation and limit values to be set based on the type of material.
NOTE 2 This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex C, being biowaste compost, green compost, solid digestate and liquid digestate).
- Status
- Not Published
- Public Enquiry End Date
- 19-Dec-2025
- Technical Committee
- KAT - Soil quality
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 17-Oct-2025
- Due Date
- 06-Mar-2026
- Completion Date
- 19-Dec-2025
- Mandate
- M/XXX - M/XXX
oSIST prEN 16087-1:2025 is the Slovenian publication of the CEN draft prEN 16087-1:2025 from SIST and CEN. It specifies a method for determining the aerobic biological degradation rate of organic matter by measuring the oxygen uptake rate (OUR) in soil improvers and growing media. Laboratories, manufacturers and conformity assessors use it to judge the stability of materials such as compost and digestate under controlled test conditions.
What does oSIST prEN 16087-1:2025 specify?
oSIST prEN 16087-1:2025 specifies a laboratory method for measuring OUR as a direct indicator of the degradation rate of biodegradable organic matter. The scope includes materials used as ingredients in growing media, soil improvers and organic fertilisers, and it also applies to growing media and soil improvers themselves.
The method is not suitable for materials with more than 20 % by volume of particles larger than 20 mm. The document is organized into Scope, Normative references, Terms and definitions, Principle, Apparatus, Reagents, Sampling, Procedure, Calculations, Test report and Validation of the method, followed by three informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Specific information on the OUR-test, including vessel and curve figures |
| Annex B | Incubation temperature and the effect of 20 °C versus 30 °C |
| Annex C | Performance characteristics from the interlaboratory study |
What are the key requirements of oSIST prEN 16087-1:2025?
oSIST prEN 16087-1:2025 measures respiration in a closed vessel by tracking pressure drop in the headspace while carbon dioxide is absorbed. In practice, this means the sample is suspended in water, kept under defined conditions and monitored as oxygen is consumed by biological activity.
Sampling and sample preparation
Clause 7 sends sampling to EN 12579. That matters because the laboratory result is only meaningful if the received sample still represents the product as delivered.
Clauses 8.2 to 8.4 give separate preparation routes for solid materials below 10 mm, solid materials below 20 mm and liquid materials. The sample is sieved, coarse particles above the stated limit are removed, and the sample is stored at 3 °C ± 2 °C for no more than 2 weeks. This controls particle size and storage effects, which can otherwise change the measured respiration.
Test set-up and reagents
Clause 5 specifies the main equipment, including a temperature-controlled environment at 20 °C or 30 °C, a pressure transducer, a gas-tight reaction vessel, a mixing device, a balance and a pH meter. Clause 6 defines the water quality, buffer, nutrient solutions, nitrification inhibitor, carbon dioxide absorbent and inoculum.
These details matter because OUR depends strongly on temperature, pH, oxygen availability and microbial activity. The method uses a nitrification inhibitor to keep nitrification from inflating oxygen consumption, and it allows inoculum for materials with low microbial activity.
Running the measurement
Clause 8.6 sets the starting point for the test mass and requires the suspension to be adjusted to pH 6.5 to 7.5 before mixing. Clause 8.7 requires pressure to be recorded over seven days, typically 2 to 4 times per hour.
The method also limits pressure drop and gives actions if oxygen depletion occurs. If the sample consumes oxygen too quickly, the operator may use pure oxygen, reduce the sample amount, or increase vessel volume. In practice, this prevents the test from stopping because of the set-up rather than because of the material.
Calculations and reporting
Clause 9 converts pressure drop into oxygen consumption and then into OUR. Clause 10 requires the report to identify the standard used, identify the sample, state the mean OUR and testing temperature, and note any optional or non-standard work cycles.
Clause 11 states that the method was validated in an interlaboratory study and that performance characteristics are given in Annex C. For users, this is the evidence base for comparing results between laboratories.
What terms does oSIST prEN 16087-1:2025 define?
- OUR - Oxygen uptake rate, the measured rate of oxygen consumption used here as the main result.
- OM - Organic matter content, used to express and normalize the test result.
- DM - Dry matter content, needed for calculating the sample mass and gas-phase volume.
- Headspace - The gas phase above the water phase in the closed vessel where pressure is measured.
- Inoculum - An extract from active compost added to samples with little microbial activity.
- Nitrification inhibitor - A substance added to reduce oxygen use by nitrification, so the result reflects degradation of organic matter more directly.
- C/N ratio - Carbon-to-nitrogen ratio, which affects how OUR relates to material stability.
Who uses oSIST prEN 16087-1:2025?
oSIST prEN 16087-1:2025 is used by laboratories testing compost, digestate and other component materials for growing media and soil improvers. It also supports manufacturers, product developers, quality managers and buyers who need to compare biological stability between materials.
Regulators and conformity assessment bodies can use it when a product decision depends on a standardized respiration result. It is especially relevant where the material is intended for fertiliser-related applications and the behaviour of organic matter needs to be documented.
What changed in oSIST prEN 16087-1:2025 from the previous edition?
oSIST prEN 16087-1:2025 supersedes EN 16087-1:2011. The foreword lists these technical changes:
- balance requirements were added
- sample preparation in 8.2 was clarified
- formulas 3 and 5 were corrected
- the figures in Annex A were updated
- the bibliography was corrected
- the testing temperature was changed from a single temperature to 20 °C or 30 °C, with guidance in Annex B
Which standards are used with oSIST prEN 16087-1:2025?
- CEN/TS 17732:2022 - provides the terms and definitions used by this standard.
- EN 12579:2024 - gives the sampling method for soil improvers and growing media.
- prEN 13039:2025 - is used for determining organic matter content and ash.
- prEN 13040-1:2025 - is used for sample preparation and for dry matter and moisture content.
- EN 45501 - sets the metrological requirements for the balance.
- ISO 5725-2 - is used in the method validation and performance analysis.
What does the oSIST prEN 16087-1:2025 document contain?
oSIST prEN 16087-1:2025 contains the apparatus list, reagent preparation, sample preparation routes and the step-by-step OUR test procedure. It also gives the calculation approach for converting pressure drop into oxygen consumption and OUR, plus the required test report items.
Annex A adds figures of the reaction vessel, stirrer arrangement and typical pressure curve. Annex B explains why incubation temperature matters and when 20 °C or 30 °C is preferred. Annex C reports repeatability and reproducibility data from the interlaboratory study, which is useful for method evaluation, quality control and conformity work.
Relations
- Effective Date
- 01-Dec-2025
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.

ECOCERT
Organic and sustainability certification.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
oSIST prEN 16087-1:2025 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Soil improvers and growing media - Determination of the aerobic biological degradation rate of organic matter - Part 1: Oxygen uptake rate (OUR)". This standard covers: This document describes a method to determine the stability of materials (e.g. compost, digestate) used as components (ingredients) in growing media, soil improvers and organic fertilizers by measuring the oxygen uptake rate (OUR). It can also be used for growing media and soil improvers. The oxygen uptake rate is a direct parameter for the degradation rate of biodegradable organic matter that is being broken down within a specified time period. The method is not suitable for materials with a content of particle sizes > 20 mm exceeding 20 % by volume. NOTE 1 The relation between the degradation rate and the oxygen uptake rate under the same conditions is depending on the type of material, for example by the C/N ratio. So it is important for the interpretation and limit values to be set based on the type of material. NOTE 2 This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex C, being biowaste compost, green compost, solid digestate and liquid digestate).
This document describes a method to determine the stability of materials (e.g. compost, digestate) used as components (ingredients) in growing media, soil improvers and organic fertilizers by measuring the oxygen uptake rate (OUR). It can also be used for growing media and soil improvers. The oxygen uptake rate is a direct parameter for the degradation rate of biodegradable organic matter that is being broken down within a specified time period. The method is not suitable for materials with a content of particle sizes > 20 mm exceeding 20 % by volume. NOTE 1 The relation between the degradation rate and the oxygen uptake rate under the same conditions is depending on the type of material, for example by the C/N ratio. So it is important for the interpretation and limit values to be set based on the type of material. NOTE 2 This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex C, being biowaste compost, green compost, solid digestate and liquid digestate).
oSIST prEN 16087-1:2025 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN 16087-1:2025 has the following relationships with other standards: It is inter standard links to SIST EN 16087-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN 16087-1:2025 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564, M/564 AMD 1, M/564 AMD 2, M/XXX. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
oSIST prEN 16087-1:2025 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2025
Izboljševalci tal in rastni substrati - Določanje aerobne biološke razgradljivosti
organskih snovi - 1. del: Stopnja porabe kisika (OUR)
Soil improvers and growing media - Determination of the aerobic biological degradation
rate of organic matter - Part 1: Oxygen uptake rate (OUR)
Bodenverbesserungsmittel und Kultursubstrate - Bestimmung der aeroben biologischen
Abbaurate organischer Substanz - Teil 1: Sauerstoffaufnahme (OUR)
Amendements du sol et supports de culture - Détermination de la cinétique de
dégradation biologique aérobie de la matière organique - Partie 1 : Cinétique
d’absorption de l’oxygène (OUR)
Ta slovenski standard je istoveten z: prEN 16087-1
ICS:
65.080 Gnojila Fertilizers
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
prEN 16087-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2025
ICS 65.080 Will supersede EN 16087-1:2020
English Version
Soil improvers and growing media - Determination of the
aerobic biological degradation rate of organic matter - Part
1: Oxygen uptake rate (OUR)
Amendements du sol et supports de culture - Bodenverbesserungsmittel und Kultursubstrate -
Détermination de la cinétique de dégradation Bestimmung der aeroben biologischen Abbaurate
biologique aérobie de la matière organique - Partie 1 : organischer Substanz - Teil 1: Sauerstoffaufnahme
Cinétique d'absorption de l'oxygène (OUR) (OUR)
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 223.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16087-1:2025 E
worldwide for CEN national Members.
prEN 16087-1:2025 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Principle . 4
5 Apparatus . 4
6 Reagents . 5
7 Sampling . 6
8 Procedure . 6
8.1 Safety . 6
8.2 Sample preparation for solid materials < 10 mm . 6
8.3 Sample preparation for solid materials < 20 mm . 7
8.4 Sample preparation for liquid materials . 7
8.5 Determination of moisture content and organic matter content . 7
8.6 Starting the procedure . 7
8.7 Respiration measurement . 8
9 Calculations . 9
9.1 Theoretical background . 9
9.2 Calculations . 9
10 Test report . 10
11 Validation of the method . 10
11.1 Validation in accordance with ISO 5725-2. 10
11.2 Performance characteristics. 10
Annex A (informative) Specific information on the OUR-test . 11
Annex B (informative) Incubation temperature. 13
Annex C (informative) Performance characteristics of the method . 14
Bibliography . 18
prEN 16087-1:2025 (E)
European foreword
This document (prEN 16087-1:2025) has been prepared by Technical Committee CEN/TC 223 “Soil
improvers and growing media”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 16087-1:2011.
prEN 16087-1:2025 includes the following significant technical changes with respect to
EN 16087-1:2011:
— For the balance (5.6) requirements have been added;
— Clarification of sample preparation (8.2) has been added;
— Formula (3) and 5 have been corrected;
— The figures in Annex A have been updated;
— The Bibliography has been corrected;
— The temperature of testing was for all products 30 °C but it has been changed. Products may be tested
at 20 or 30 °C. Background about the differences between the testing temperatures and the to choose
temperature can be found in Annex B.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
prEN 16087-1:2025 (E)
1 Scope
This document describes a method to determine the stability of materials (e.g. compost, digestate) used
as components (ingredients) in growing media, soil improvers and organic fertilisers by measuring the
oxygen uptake rate (OUR). The oxygen uptake rate is a direct parameter for the degradation rate of
biodegradable organic matter that is being broken down within a specified time period. The method is
not suitable for material with a content of particle sizes > 20 mm exceeding 20 % by volume.
NOTE The relation between the degradation rate and the oxygen uptake rate under the same conditions is
depending on the type of material, for example by the C/N ratio. So it is important for the interpretation and limit
values to be set based on the type of material.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
CEN/TS 17732:2022, Soil improvers and growing media — Terminology
EN 12579:2024, Soil improvers and growing media — Sampling
prEN 13039:2025, Soil improvers and growing media — Determination of organic matter content and ash
prEN 13040-1:2025, Soil improvers and growing media — Sample preparation — Part 1: Sample
preparation for chemical and physical tests, determination of dry matter content, moisture content and
laboratory bulk density
EN 45501, Metrological aspects of non-automatic weighing instruments
3 Terms and definitions
For the purposes of this document, the terms and definitions given in CEN/TS 17732:2022 apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
4 Principle
The material is suspended in water. The respiration rate (i.e. oxygen uptake rate) is indirectly determined
by measuring the pressure drop in the headspace (i.e. gas phase in the closed space above the water
phase). The produced CO (carbon dioxide) is removed by a suitable alkaline absorbent. The
measurements are performed under defined conditions.
5 Apparatus
5.1 Testing facility
Temperature controlled room, climate cabinet or water bath, temperature adjustable to 20 °C ± 2 °C or
30 °C ± 2 °C.
5.2 Pressure transducer
prEN 16087-1:2025 (E)
Operating range 0 kPa to 20 kPa (accuracy ± 0,1 kPa) and record for measuring 2 to 4 times per hour for
seven days.
5.3 CO -absorbent containing unit
5.4 Reaction vessel
1 000 ml to 2 500 ml with a CO -absorbent containing unit (5.3) and the pressure transducer (5.2)
gastight connected (see Figure A.1).
5.5 Mixing device
Shaking Table 120 rpm ± 20 rpm or magnetic stirring unit and banded magnetic stirrer (see Figure A.2).
5.6 Balance
Meeting EN 45501 class II tolerances with a verification scale interval of 0,01 g.
5.7 pH meter
With slope adjustment and temperature control.
5.8 Dispenser
Dispensers or pipettes, adjustable units of 0,5 ml.
5.9 Glassware
Beakers and measuring cylinder.
5.10 Sieves
10 mm and 20 mm square aperture size.
5.11 Filter paper
Filter paper, with low ash content and high retentive properties.
6 Reagents
6.1 Water with a specific conductivity not higher than 0,2 mS/m at 25 °C
6.2 pH buffer
86 g/l KH PO , 89 g/l Na HPO ⋅ 2H O, mix ratio of 1:4 for pH 7; the solution is stable for 2 months if
2 4 2 4 2
stored at 1 °C to 5 °C. When a particulate precipitation is found a fresh solution is to be made.
Commercially available buffers may be used as well.
6.3 Macronutrient solution
Dissolve the following masses of chemical compounds in 1 000 ml water (6.1): 4,3 g NH Cl,
5,4 g CaCl ⋅ 2H O, 4,3 g MgSO ⋅ 7H O
2 2 4 2
The solution is stable for 2 months if stored at 3 °C ± 2°C. When a particulate precipitation is found a fresh
solution is to be made.
6.4 Micronutrient solution
prEN 16087-1:2025 (E)
Dissolve the following masses or volumes of chemical compounds in 1 000 ml water (6.1): 5,0 g EDDHA
iron chelate (60 g Fe/kg), 1,4 g MnSO , 1,1 g ZnSO , 4,2 g Na B O , 0,2 g CuSO , 0,13 g Na MoO ,
4 4 2 4 7 4 2 4
1 ml/l HCl (360 g/kg).
The solution is stable for 2 months if stored at 3 °C ± 2°C. When a particulate precipitation is found a fresh
solution is to be made.
6.5 Complete nutrient solution
Add 1 ml of micronutrient solution (6.4) to 1 000 ml of macronutrient solution (6.3). The solution is
stable for 2 months if stored at 3 °C ± 2°C. When a particulate precipitation is found a fresh solution is to
be made.
6.6 Nitrification inhibitor
4 g/l N-Allylthiourea, C H N S (ATU).
4 8 2
Store the solution in a closed container at 1 °C to 5 °C. The solution is stable for not more than 2 weeks.
6.7 CO -absorbent
Such as NaOH-pellets, KOH-pellets or soda lime (mixture of Ca(OH) , NaOH, KOH and water), preferably
with colour indicator.
NOTE Based on experience, 4,0 g of pellets (carbon dioxide absorption capacity > 200 g/kg) per container is
sufficient.
6.8 NaOH (0,5 mol/l)
6.9 HCI (0,5 mol/l)
6.10 Inoculum (to be added for materials without or low microbial activity)
–1 −1
Prepare an extract by shaking an active compost (OUR level 25 to 30 mmol O · kg · OM · hour ) with
water at mass:volume, 1:10 and filter it over a filter paper (5.11).
7 Sampling
Sampling is not part of the method specified in this document. Follow EN 12579:2024 dealing with soil
improvers and growing media. It is important that the laboratory receives a sample that is representative
of the product under consideration. The sample should not have been damaged or changed during
transport or storage.
8 Procedure
8.1 Safety
SAFETY PRECAUTIONS — Care should be taken when handling substances of caustic nature or samples
that may contain sharps or is of a dusty nature.
8.2 Sample preparation for solid materials < 10 mm
Take minimally 1 l of material. Manually, but carefully, break up lumps and agglomerates only that have
been caused by, for example, compress ion during transport. Break up lumps and agglomerates only and
pass the sample through a 10 mm sieve (5.10), gently agitating the material if required. Particles > 10 mm
shall not be broken up and shall be removed. Record the % mass of particles > 10 mm. If this amount
prEN 16087-1:2025 (E)
is > 20 % of the total fresh mass the procedure for materials < 20 mm (8.3) is to be followed. The moist
sample shall be stored at 3 °C ± 2 °C (total storage time max. 2 weeks).
8.3 Sample preparation for solid materials < 20 mm
Take minimally 1 l of material. Manually, but carefully, break up lumps and agglomerates only that have
been caused by, for example, compression during transport. Break up lumps and agglomerates only and
pass the sample through a 20 mm sieve (5.10), gently agitating the material if required. Particles > 20 mm
shall not be broken up and shall be removed. Record the % mass of particles > 20 mm. If this amount
is > 20 % of the total fresh mass, the test is not applicable. The moist sample shall be stored at 3 °C ± 2°C
(total storage time max. 2 weeks).
8.4 Sample preparation for liquid materials
Take minimally 1 l of material. Homogenize the sample by stirring. Break up lumps and agglomerates
only and pass the sample through a 10 mm sieve (5.10), gently agitating the material if required.
Particles > 10 mm shall not be broken up and shall be removed. Record the % mass of particles > 10 mm.
If this amount is > 20 % of the total fresh mass, the test is not applicable. The sample shall be stored at
3 °C ± 2 °C (total storage time max. 2 weeks). Stir the sample just before using it again.
8.5 Determination of moisture content and organic matter content
The moisture content shall be determined according to prEN 13040-1:2025 and the organic matter
content according to prEN 13039:2025, both determinations should take place after the sample
preparation.
8.6 Starting the procedure
For solid materials < 10 mm and liquid materials (8.2 and 8.4), calculate the mass of fresh material (EOM)
to be added to the reaction vessel based on 2 g of organic matter per litre according to Formula (1).
EOM g = (1)
( )
WW×
om d
where
W is the organic matter content, in % mass of the dried sample according to prEN 13039:2025;
om
W is the dry matter content, in % mass of the fresh sample according to prEN 13040-1:2025.
d
Calculate the required mass of sample (W ) to perform the test according to Formula (2).
S
W g EOM× C (2)
( )
S V
where
C is the capacity of the vessel in litres.
V
Place the calculated quantity of the sample in the clean reaction vessel (5.4). Add 180 ml water (6.1) and
10 ml complete nutrient solution (6.5) using a dispenser (5.8). Add 10 ml pH buffer (6.2) using a
dispenser (5.8). Add 2,5 ml nitrification inhibitor (6.6) using a dispenser (5.8). For materials without or
low microbial activity (e.g. wood fibre directly after production), 5 ml inoculum (6.10) can be added.
Then, measure the pH of the suspension. The value should be between 6,5 and 7,5. If this is not the case,
base or acid should be added (see 6.8 and 6.9). Place the sample on the mixing device (5.5) and start the
mixing for 4 h to 8 h in the conditioned room (5.1).
The analyses shall be performed at least
...