oSIST prEN 13598-1:2026
(Main)Plastics piping systems for non-pressure underground drains and sewers - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings and shallow chambers
- Abstract
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater.
This document is applicable to:
a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”;
b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system.
The document is applicable to the following ancillary fittings:
— sealed access fittings;
— rodding point covers;
— rodding tees;
— mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas.
Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level.
Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated.
NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible.
NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation.
NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
- Status
- Not Published
- Public Enquiry End Date
- 30-Jan-2026
- Technical Committee
- PCV - Plastic pipes, fittings and valves
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 01-Dec-2025
- Due Date
- 20-Apr-2026
- Completion Date
- 02-Feb-2026
oSIST prEN 13598-1:2026 is a draft European Standard from CEN, published by SIST, for PVC-U, PP and PE ancillary fittings and shallow chambers used in non-pressure underground drains and sewers for wastewater. It specifies definitions, material and dimensional requirements, mechanical and sealing performance, marking, and installation information for the people who make, test, specify, buy, or install these components.
What does oSIST prEN 13598-1:2026 specify?
oSIST prEN 13598-1:2026 specifies the requirements for ancillary fittings and shallow chambers in plastics piping systems for non-pressure underground drains and sewers. It also covers the jointing of these components to the piping system, so the document is not limited to the fitting itself.
The scope covers two application areas:
- U - buried underground outside the building structure
- UD - buried underground outside the building structure and within the building structure
It applies to these ancillary fittings:
- sealed access fittings
- rodding point covers
- rodding tees
- mechanical saddles
Ancillary fittings are intended for pedestrian areas, except rodding tees and mechanical saddles, which may also be used in vehicular trafficked areas. Shallow chambers are intended for private drains in pedestrian areas above the groundwater table, to a maximum depth of 2.0 m from ground level to the invert of the main flow channel.
The document is organized into clauses 1 to 14, followed by Annexes A to E. Clauses 1 to 4 cover scope, references, terms, symbols and abbreviations, and clauses 5 to 14 cover materials, appearance, geometry, mechanical and physical performance, joints, marking, and documentation.
| Annex | What it covers |
|---|---|
| Annex A | Material characteristics for shallow chamber components |
| Annex B | Use of recyclates in shallow chambers |
| Annex C | Test methods for mechanical saddles |
| Annex D | Resistance to vertical loading of shallow chambers |
| Annex E | List of product standards for compatible pipes and fittings |
Products complying with the document can be used with compatible pipes, fittings and other components from the product standards listed in Annex E. The scope also notes that products complying with the document can be installed in underground applications without additional static calculation.
What are the key requirements of oSIST prEN 13598-1:2026?
The document sets requirements for materials, dimensions, mechanical strength, watertightness, marking and installation information. In practice, these are the points that decide whether a component can be connected, tested and documented as part of a sewer system.
Materials and product types
Clause 5 ties ancillary fittings to the relevant pipe and fitting standards for PVC-U, PP, PE and PP-MD, and Annex A sets material characteristics for shallow chambers. This matters because the component has to match the material family and the declared properties used in the system design and production control.
For shallow chambers, Annex A allows testing of material characteristics, while Clause 5 also permits use of materials already conforming to the named product standards without testing to Annex A. If recyclates are used, Annex B applies and the manufacturer must control the recyclate specification and recorded dosage.
Geometry and compatibility
Clause 7 requires the manufacturer to declare relevant dimensions and tolerances, with all dimensions measured to EN ISO 3126. For ancillary fittings, the dimensions of sockets, spigots and body walls must suit the pipe standards they connect to.
For shallow chambers, the base and riser are treated differently, and the first 300 mm of an integral riser are handled as part of the base for testing. This matters because manufacturers must separate design, declaration and test logic for base and riser parts.
Mechanical and functional performance
Clause 8 requires mechanical characteristics for sealed access fittings, rodding tees, mechanical saddles and shallow chambers, with separate tables for fabricated fittings. The practical effect is that the document checks whether the component can survive impact, loading, deformation and the structural conditions expected in underground use.
For shallow chambers, the document includes ring stiffness of the riser, structural integrity of the base, and resistance to vertical loading. For mechanical saddles, Annex C defines the test arrangements for vertical load, mechanical strength and tightness under deformation.
Joint tightness and system fitness for purpose
Clauses 10, 12 and 13 focus on the joint, not only the part body. Elastomeric sealing rings have to meet the relevant EN 681 part, and adhesives have to meet EN 14680, with EN 14814 allowed as an alternative.
Clause 10 sets fitness-for-purpose testing for joints and systems, including tightness under socket deflection, angular deflection, elevated temperature cycling, and pressure or air tightness where applicable. This matters because a fitting can look acceptable yet still leak or open up under movement, which is a key issue in buried systems.
Recyclates and traceability
Annex B allows recyclates in shallow chambers only under controlled conditions. The manufacturer must define an agreed specification, record the recyclate quantity used in each production series, and demonstrate conformity at the maximum recyclate content declared for the product.
Clause 14 adds traceability through marking and, where relevant, production year and production-site identification. In practice, this supports quality control, complaints handling and product identification on site.
Marking and installation information
Clause 14 requires minimum marking for sealed access fittings, rodding tees, mechanical saddles and shallow chamber bases. It also requires installation information such as recommended bedding and side-fill compaction for shallow chambers, and cutter diameter guidance plus compatible pipe sizes for mechanical saddles.
That documentation matters because it tells the installer how the component is intended to be fitted and what it is meant to connect to. For shallow chambers, separately sold risers also need identification and size marking.
What terms does oSIST prEN 13598-1:2026 define?
- Application area code - The marking code that shows whether the product is for area U or UD.
- Sealed access fitting - A fitting that allows rodding or inspection and has a sealed cover.
- Rodding point cover - A ground-level fitting with a removable cover for inspection or clearing blockages.
- Rodding tee - A fitting that connects to a ground-level rodding point and allows rodding or inspection in one or more directions.
- Mechanical saddle - A fitting that creates a branch connection to a larger buried pipe and is held in place mechanically.
- Shallow chamber - A chamber installed to a maximum depth of 2.0 m that allows surface-level cleaning and inspection, but not personnel access.
- Virgin material - Plastics material that has not been used or processed beyond its initial manufacture.
- Recyclate - Plastics material resulting from recycling pre-consumer or post-consumer plastics products.
Who uses oSIST prEN 13598-1:2026?
Manufacturers of underground plastics drainage components use this document to design products, choose materials, set dimensions and define marking. Testing laboratories use it to run the mechanical, tightness and material tests in Clauses 8 to 12 and Annexes A to D.
Specifiers, consulting engineers and quality managers use it when selecting compatible ancillary fittings or shallow chambers for sewer projects. Buyers and procurement teams use it to compare products on a common technical basis.
Installers and site supervisors use the installation documentation in Clause 14, especially for bedding, side-fill compaction, cutter size and pipe compatibility. It is relevant to the external sewage and building drainage sectors, especially where PVC-U, PP and PE systems are connected underground.
What changed in oSIST prEN 13598-1:2026 from the previous edition?
This draft will supersede EN 13598-1:2020. The foreword states these significant technical changes:
- terminology updated to align with the TC155 Oslo agreement and EN 14541-1
- additional terms and definitions added
- material clauses and Annex A updated
- unit and symbol formatting in tables updated
- test methods updated to the latest EN ISO standards where applicable
- terms, definitions, symbols and figures updated
- mechanical characteristics tables updated
- the “resistance to vacuum” characteristic replaced by “structural integrity of base”
- limits specified for horizontal and vertical deflection
Which standards are used with oSIST prEN 13598-1:2026?
| Standard | What it contributes |
|---|---|
| EN 124 (all parts) | Cover and frame requirements for gully tops and manhole tops used with some ancillary fittings |
| EN 1253-2:2015 | Applicable option for rodding point covers in building-related use |
| EN 476 | General requirements for components used in drains and sewers |
| EN 681-1 to EN 681-4 | Elastomeric sealing ring material requirements |
| EN 1401-1, EN 1852-1, EN 12666-1, EN 13476-1 to -3, EN 14758-1 | Compatible pipe and fitting system standards for PVC-U, PP, PE and PP-MD |
| EN 14680 | Adhesives for non-pressure thermoplastics piping systems |
| EN ISO 3126 | Dimensional measurement method |
| EN ISO 13259 | Tightness test for elastomeric sealing ring joints |
| EN ISO 13257 | Elevated temperature cycling test |
| EN ISO 13263 | Impact test for thermoplastics fittings |
| EN ISO 13264 | Mechanical strength or flexibility test for fabricated fittings |
| EN ISO 13268 | Ring stiffness test for thermoplastics shafts or risers |
| EN ISO 13254 | Watertightness test for non-pressure thermoplastics piping systems |
| EN ISO 9001 | Quality management reference in the recyclate annex |
| EN 15346:2024 and EN 15344:2025 | Characterization references for PVC and PE recyclates |
| CEN/TS 16010 and CEN/TS 16011 | Sampling and sample preparation guidance for recyclates |
| EN 14814 | Alternative adhesive standard named for use with thermoplastic piping systems |
| EN 13598-2 and EN 13598-3 | Companion parts in the same product family, listed as under revision |
What does the oSIST prEN 13598-1:2026 document contain?
oSIST prEN 13598-1:2026 contains figures showing typical sealed access fittings, rodding point covers, rodding tees, mechanical saddles and shallow chambers. It also contains tables for mechanical characteristics, physical properties, performance requirements, marking and material characteristics.
Annex C gives the test setups for mechanical saddles, including vertical loading, mechanical strength and tightness under deformation. Annex D gives the buried test for resistance to vertical loading of shallow chambers.
The document also includes formulas and technical limits used for material characterization and joint assessment, as well as instructions for how to assemble test pieces and how to mark products for traceability.
Relations
- Effective Date
- 09-Oct-2024
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija
ZAG inspection body for construction products, structures, and materials.
Sponsored listings
Frequently Asked Questions
oSIST prEN 13598-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics piping systems for non-pressure underground drains and sewers - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings and shallow chambers". This standard covers: This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater. This document is applicable to: a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”; b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”. This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system. The document is applicable to the following ancillary fittings: — sealed access fittings; — rodding point covers; — rodding tees; — mechanical saddles. Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas. Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level. Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system. Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated. NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible. NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation. NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater. This document is applicable to: a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”; b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”. This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system. The document is applicable to the following ancillary fittings: — sealed access fittings; — rodding point covers; — rodding tees; — mechanical saddles. Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas. Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level. Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system. Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated. NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible. NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation. NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
oSIST prEN 13598-1:2026 is classified under the following ICS (International Classification for Standards) categories: 23.040.05 - Pipeline and its parts for external sewage systems; 23.040.20 - Plastics pipes; 93.030 - External sewage systems. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN 13598-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 13598-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN 13598-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2026
Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo
po težnostnem principu in so položeni v zemljo - Nemehčan polivinilklorid (PVC-
U), polipropilen (PP) in polietilen (PE) - 1. del: Specifikacije za pomožne fitinge in
plitve revizijske jaške
Plastics piping systems for non-pressure underground drains and sewers - Unplasticized
poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1:
Specifications for ancillary fittings and shallow chambers
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -
leitungen - Weichmacherfreies Polyvinylchlorid (PVC-U), Polypropylen (PP) und
Polyethylen (PE) - Teil 1: Anforderungen an Zubehörteile und Schächte mit geringer
Einbautiefe
Systèmes de canalisations en plastique pour les branchements et les collecteurs
d’assainissement enterrés sans pression - Poly(chlorure de vinyle) non plastifié
(PVC‐U), polypropylène (PP) et polyéthylène (PE) - Partie 1: Spécifications relatives
aux raccords auxiliaires et aux boîtes d’inspection et de branchement peu profondes
Ta slovenski standard je istoveten z: prEN 13598-1
ICS:
23.040.05 Cevovodi za zunanje Pipeline and its parts for
sisteme za odpadno vodo in external sewage systems
njihovi deli
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
prEN 13598-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2025
ICS 23.040.20 Will supersede EN 13598-1:2020
English Version
Plastics piping systems for non-pressure underground
drains and sewers - Unplasticized poly(vinyl chloride)
(PVC-U), polypropylene (PP) and polyethylene (PE) - Part
1: Specifications for ancillary fittings and shallow
chambers
Systèmes de canalisations en plastique pour les Kunststoff-Rohrleitungssysteme für erdverlegte
branchements et les collecteurs d'assainissement drucklose Abwasserkanäle und -leitungen -
enterrés sans pression - Poly(chlorure de vinyle) non Weichmacherfreies Polyvinylchlorid (PVC-U),
plastifié (PVC-U), polypropylène (PP) et polyéthylène Polypropylen (PP) und Polyethylen (PE) - Teil 1:
(PE) - Partie 1: Spécifications relatives aux raccords Anforderungen an Zubehörteile und Schächte mit
auxiliaires et aux boîtes d'inspection et de geringer Einbautiefe
branchement peu profondes
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 155.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13598-1:2025 E
worldwide for CEN national Members.
prEN 13598-1:2025 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 6
3 Terms and definitions . 8
4 Symbols and abbreviations . 15
4.1 Symbols . 15
4.2 Abbreviations . 16
5 Material . 16
5.1 Ancillary fittings . 16
5.2 Shallow chambers . 16
5.3 Sealing ring retaining components . 16
6 General characteristics . 16
6.1 Appearance . 16
6.2 Colour . 17
6.3 Assemblies . 17
7 Geometrical characteristics . 17
7.1 General . 17
7.2 Design lengths . 17
7.3 Dimensions of ancillary fittings . 17
7.4 Dimensions of shallow chambers . 17
7.5 Additional requirements for sealed access fittings . 18
8 Mechanical characteristics . 18
9 Physical characteristics of ancillary fittings . 20
9.1 Injection moulded fittings . 20
9.2 Fabricated fittings . 20
10 Performance requirements . 20
11 Characterization of rotationally moulded product submitted for performance testing . 23
12 Sealing rings . 23
13 Adhesives . 23
14 Marking and additional documentation . 23
14.1 General . 23
14.2 Minimum required marking, sealed access fittings and rodding tees . 24
14.3 Minimum required marking, mechanical saddles . 24
14.4 Minimum required marking, shallow chambers . 24
14.5 Additional documentation, shallow chambers . 25
14.6 Additional documentation, mechanical saddles . 25
Annex A (normative) Material characteristics . 26
Annex B (normative) Utilization of of recyclates for shallow chambers . 28
Annex C (normative) Test methods for mechanical saddles . 33
prEN 13598-1:2025 (E)
Annex D (normative) Resistance to vertical loading of shallow chambers . 38
Annex E (informative) List of product standards . 39
Bibliography . 41
prEN 13598-1:2025 (E)
European foreword
This document (prEN 13598-1:2025) has been prepared by Technical Committee CEN/TC 155 “Plastics
piping systems and ducting systems”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN enquiry.
This document will supersede EN 13598-1:2020.
prEN 13598-1:2025 includes the following significant technical changes with respect to EN 13598
1:2020:
1) the terminology has been updated to align with the TC155 Oslo agreement and EN 14541-1.
Additional terms and definitions have also been included.
2) material clauses and Annex A have been updated;
3) the format of units and symbols in tables has been updated.
4) test methods have been updated to the latest EN ISO standards where applicable;
5) terms, definitions, symbols and figures have been updated;
6) the mechanical characteristics tables have been updated;
7) the “resistance to vacuum” characteristic has been replaced by a “structural integrity of base”;
8) Limits are specified for horizontal and vertical deflection.
EN 13598 consists of the following parts under the general title Plastics piping systems for non-pressure
underground drains and sewers — Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and
polyethylene (PE):
— Part 1: Specifications for ancillary fittings and shallow chambers (this document);
— Part 2: Specifications for manholes and inspection chambers (under revision);
— Part 3: Guidance for assessment of conformity (CEN/TS under revision).
prEN 13598-1:2025 (E)
1 Scope
This document is part of a System Standard for plastics piping systems of a particular material for a
specified application. There are a number of such System Standards.
System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes,
fittings and valves for the transport of fluids”, which is a Technical Committee of the International
Organization for Standardization (ISO).
They are supported by separate standards on test methods, to which references are made throughout the
System Standard.
The System Standards are consistent with general standards on functional requirements and on
recommended practice for installation.
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U),
polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in
non-pressure underground drains and sewers for wastewater.
This document is applicable to:
a) ancillary fittings and shallow chambers, intended for use buried underground outside the building
structure; reflected in the marking of products by “U”;
b) ancillary fittings and shallow chambers, intended for use buried underground both outside
(application area code “U”) and within the building structure, reflected in the marking of products by
“UD”.
This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system.
The document is applicable to the following ancillary fittings:
— sealed access fittings;
— rodding point covers;
— rodding tees;
— mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees
and mechanical saddles which can also be used in vehicular trafficked areas.
Ancillary fittings can be installed to a maximum depth of 6,0 m from ground level, with the exception of
rodding point covers with a maximum depth of 2,0 m.
Shallow chambers according to this document are intended for use in private drains located in pedestrian
areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the
main flow channel. This document covers shallow chambers having a base with a flow channel and their
joints to the piping system.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding,
rotational moulding, spiral winding or fabricated.
NOTE 1 Products complying with this document can be used with pipes, fittings and other components
conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible.
NOTE 2 Products complying with this document can be installed in underground applications without additional
static calculation.
prEN 13598-1:2025 (E)
NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 124 (all parts), Gully tops and manhole tops for vehicular and pedestrian areas
EN 295-3:2012, Vitrified clay pipe systems for drains and sewers – Part 3: Test methods
EN 476, General requirements for components used in drains and sewers
EN 681-1, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage
applications – Part 1: Vulcanized rubber
EN 681-2, Elastomeric Seals – Materials requirements for pipe joint seals used in water and drainage
applications – Part 2: Thermoplastic elastomers
EN 681-3, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage
applications – Part 3: Cellular materials of vulcanized rubber
EN 681-4, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage
applications – Part 4: Cast polyurethane sealing elements
EN 1253-2:2015, Gullies for buildings - Part 2: Roof drains and floor gullies without trap
EN 1401-1, Plastics piping systems for non-pressure underground drainage and sewerage – Unplasticized
poly(vinyl chloride) (PVC-U) – Part 1: Specifications for pipes, fittings and the system
EN 1852-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polypropylene
(PP) – Part 1: Specifications for pipes, fittings and the system
EN 12099, Plastics piping systems – Polyethylene piping materials and components – Determination of
volatile content
EN 12666-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polyethylene
(PE) – Part 1: Specifications for pipes, fittings and the system
EN 13476 (all parts), Plastics piping systems for non-pressure underground drains and sewers – Structured-
wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE)
EN 13476-1, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall
piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) –
Part 1:General requirements and performance characteristics
EN 13476-2, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall
piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) –
Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type
A
prEN 13598-1:2025 (E)
EN 13476-3, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall
piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) –
Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the
system, Type B
EN 14680, Adhesives for non-pressure thermoplastics piping systems – Specifications
EN 14758-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polypropylene
with mineral modifiers (PP-MD) – Part 1: Specifications for pipes, fittings and the system
EN ISO 472, Plastics – Vocabulary (ISO 472)
EN ISO 1043-1, Plastics – Symbols and abbreviated terms – Part 1: Basic polymers and their special
characteristics (ISO 1043-1)
EN ISO 1133-1, Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR)
of thermoplastics – Part 1: Standard method (ISO 1133-1)
EN ISO 1158, Plastics - Vinyl chloride homopolymers and copolymers - Determination of chlorine content
(ISO 1158)
EN ISO 1183-1, Plastics – Methods for determining the density of non-cellular plastics – Part 1: Immersion
method, liquid pycnometer method and titration method (ISO 1183-1)
EN ISO 1183-2, Plastics – Methods for determining the density of non-cellular plastics – Part 2: Density
gradient column method (ISO 1183-2)
EN ISO 2507-1, Thermoplastics pipes and fittings – Vicat softening temperature – Part 1: General test
method (ISO 2507-1)
EN ISO 3126, Plastics piping systems – Plastics components – Determination of dimensions (ISO 3126)
EN ISO 3451-1, Plastics – Determination of ash – Part 1: General methods (ISO 3451-1:2019)
EN ISO 3451-5, Plastics – Determination of ash – Part 5: Poly(vinyl chloride) (ISO 3451-5)
EN ISO 11357-6, Plastics – Differential scanning calorimetry (DSC) – Part 6: Determination of oxidation
induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) (ISO 11357-6)
EN ISO 13254, Thermoplastics piping systems for non-pressure applications – Test method for
watertightness (ISO 13254)
EN ISO 13257:2018, Thermoplastics piping systems for non-pressure applications – Test method for
resistance to elevated temperature cycling (ISO 13257:2018)
EN ISO 13259, Thermoplastics piping systems for underground non-pressure applications – Test method for
leaktightness of elastomeric sealing ring type joints (ISO 13259)
EN ISO 13263, Thermoplastics piping systems for non-pressure underground drainage and sewerage –
Thermoplastics fittings - Test method for impact strength (ISO 13263)
EN ISO 13264, Thermoplastics piping systems for non-pressure underground drainage and sewerage –
Thermoplastics fittings – Test method for mechanical strength or flexibility of fabricated fittings (ISO 13264)
prEN 13598-1:2025 (E)
EN ISO 13268, Thermoplastics piping systems for non-pressure underground drainage and sewerage –
Thermoplastics shafts or risers for inspection chambers and manholes – Determination of ring stiffness
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 472, EN ISO 1043-1 and the
following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/ui
— IEC Electropedia: available at https://www.electropedia.org/
3.1
application area code
code used in the marking of pipes and fittings to indicate the application area(s) for which they are
intended, as follows:
U for the area more than 1 m from the building to which the buried piping system is connected;
UD for application area U and the area under and within 1 m from the building where the pipes and the
fittings are buried in ground and are connected to the soil and waste discharge system of the
building.
3.2
drain
pipeline, usually underground, designed to carry wastewater from a source to a sewer
[Source: EN 16323:2014, 2.2.3.1]
3.3
sewer
pipeline or other construction, usually underground, designed to carry wastewater from more than one
source
[Source: EN 16323:2014, 2.2.3.12]
3.4
wastewater
water composed of any combination of water discharged from domestic, industrial or commercial
premises, surface run-off and accidentally any sewer infiltration water
[Source: EN 16323:2014, 2.3.10.65, modified – sewage (deprecated) deleted]
3.4.1
foul wastewater
wastewater comprising domestic wastewater and/or industrial wastewater
[Source: EN 16323:2014, 2.1.2.6]
3.4.2
surface water
water from precipitation, which has not seeped into the ground and is discharged to the drain or sewer
system directly from the ground or from exterior building surfaces
prEN 13598-1:2025 (E)
[Source: EN 16323:2014, 2.1.1.3, modified – Reference to Figure 1 deleted]
3.4.3
domestic wastewater
water polluted by the human life, including water discharged from kitchens, laundry rooms, lavatories,
bathrooms, toilets and similar facilities
[Source: EN 16323:2014, 2.1.2.3, modified – sewage (deprecated) deleted]
3.4.4
industrial wastewater
wastewater discharge resulting from any industrial or commercial activity
[Source: EN 16323:2014, 2.1.2.7 modified – trade wastewater (deprecated) and trade effluent
(deprecated) deleted]
3.5
private drain
discharge system which is not a part of the public drain or sewer
3.6
pedestrian area
area reserved for pedestrians and only occasionally open to vehicular traffic for delivery, cleaning
purposes or in an emergency
[Source: EN 124-1:2015, 3.1.27]
3.7
sealed access fitting
fitting that permits entry into the system for rodding or inspection and that has a sealed cover
Note 1 to entry: Figure 1 shows examples of sealed access fittings, other designs are possible.
Note 2 to entry: Sealed access fittings are typically buried to a depth of 2m or installed up to 6m when installed
within a chamber
3.8
rodding point cover
fitting installed at ground level with a removable cover that permits the introduction of equipment for
inspection and the clearance of blockages
Note 1 to entry: Figure 2 shows examples of rodding point covers, other designs are possible.
3.9
rodding tee
fitting installed in a drain or sewers that connects to a rodding point at ground level that permits the
introduction of equipment for the clearance of blockages, and also equipment for the inspection of the
connecting pipe work in one or more directions
Note 1 to entry: Figure 3 shows an example of a rodding tee, other designs are possible.
prEN 13598-1:2025 (E)
3.10
mechanical saddle
fitting that enables a branch connection to be made to buried drains and sewers of larger diameter by
cutting a hole in the larger pipe and is retained in position by mechanical means
Note 1 to entry: Figure 4 shows examples of mechanical saddles, other designs are possible.
Note 2 to entry: Preferred nominal angles for mechanical saddle branches are 45° and 90°.
3.11
shallow chamber
fitting installed to a maximum depth of 2,0 m from ground level to the invert of the main flow channel
that permits the introduction of equipment for the clearance of blockages, cleaning and inspection from
surface level, but does not provide access for personnel and which terminates at ground level with a riser
shaft of DN/ID 180 minimum and DN/ID of less than 800
Note 1 to entry: See also EN 476 for non-circular chambers.
Note 2 to entry: Figure 5a and Figure 5b show examples of shallow chambers. Other designs are possible.
3.12
shallow chamber base
bottom part of a shallow chamber, including integrally formed flow channels with benching as
appropriate
Note 1 to entry: In case of a one-piece shallow chamber, for testing purposes the base component ends at a
distance of minimum 300 mm measured from the top of the main flow channel. Above 300 mm the section should
be considered as a riser and tested accordingly.
Note 2 to entry: The benching is the transition between the formed flow channel and the inside wall of the base.
3.13
flow channel
open and accessible continuation of the sewer network in a manhole or inspection chamber to allow
directional changes maintaining the hydraulic performance of a sewer system
Note 1 to entry: The term flow profile is also used.
3.14
benching
sloped surface adjacent to the channel in a manhole or inspection chamber
3.15
invert
lowest point of the internal surface of the barrel of a pipe or channel at any cross section
3.16
shallow chamber riser
component which is connected onto a base and which defines the nominal size of the shallow chamber
Note 1 to entry: The riser can be supplied either as one or more separate items, for site jointing to the base, or
integrated with the base.
prEN 13598-1:2025 (E)
Note 2 to entry: In case of a one-piece shallow chamber, for testing purposes the riser component starts at a
distance of minimum 300 mm measured from the top of the main flow channel. Below 300 mm the section should
be considered as a base and tested accordingly.
3.17
assembly
items collectively forming a shallow chamber or ancillary fitting
Note 1 to entry: See typical examplesfor shallow chambers in Figure 5a and Figure 5b.
3.18
fabricated fitting
fittings produced from pipes and/or from injection-moulded fittings by thermoforming, adhesive joint or
welding
Note 1 to entry: Fabricated fittings need an additional fabrication step.
3.19
virgin material
plastics material in the form of pellets, granules, powder, floc, etc. that has not been subjected to use or
processing other than that required for its initial manufacture
Note 1 to entry: Does not contain any reworked plastics material and/or plastics recyclate.
Note 2 to entry: Sometimes also referred to as “primary material” or “primary plastics feedstock”
Note 3 to entry: It is understood that the addition of additives such as stabilizers and pigments is still resulting
into a virgin (plastics) material.
[SOURCE: ISO 472:2013, 2.1231, modified – Note 1 to entry, Note 2 to entry and Note 3 to entry added] .
3.20
reworked material
plastics material from rejected unused products or trimmings capable of being reclaimed within the same
process that generated it
Note 1 to entry: Reworked material does not change the status of the feedstock.
Note 2 to entry: This definition does not cover the conditions for the use of reworked material, which can be
found in the applicable product standard.
Note 3 to entry: Previously referred to as “own reprocessed material”
3.21
pre-consumer material
plastics material diverted from the waste stream during a manufacturing process, excluding reworked
(plastics) material
Note 1 to entry: Previously referred to as “post-industrial material”.
Note 2 to entry: Different categories of pre-consumer material may be considered in the applicable product
standard.
[SOURCE: ISO 14021:2016, 7.8.1.1 modified – “plastics” added, text deleted after “rework” and 2 Notes to
entry introduced]
prEN 13598-1:2025 (E)
3.22
post-consumer material
plastics material generated by households or by commercial, industrial and institutional facilities in their
role as end-users of the product which can no longer be used for its intended purpose
Note 1 to entry: This includes returns of material from the distribution chain.
Note 2 to entry: Different categories of post-consumer material may be considered in the applicable product
standard.
[SOURCE: ISO 14021:2016, 7.8.1.1 modified – “plastics” added, last sentence changed into Note 1 to entry
and Note 2 to entry introduced]
3.23
recyclate
plastics material resulting from the recycling of pre-consumer and post-consumer plastics products
Note 1 to entry: Also referred to as “secondary raw material” or “recycled plastics” or “regenerate”.
Note 2 to entry: Recycling can be chemical, physical or mechanical.
[SOURCE: ISO 472:2013, 2.1705, modified – Note 1 to entry and Note 2 to entry deleted, new Note 1 to
entry and Note 2 to entry introduced and “plastic waste” changed into “pre-consumer and post-consumer
plastics products”]
3.24
agreed specification
specification of the relevant material characteristics agreed between the supplier of the recylate and the
pipe and/or fitting manufacturer
Note 1 to entry: The agreed specification is often considered in the context of certification by a third party
organization.
Figure 1 — Examples of sealed access fittings
prEN 13598-1:2025 (E)
Figure 2 — Examples of rodding point covers
Figure 3 — Example of a rodding tee
Figure 4 — Examples of mechanical saddles
prEN 13598-1:2025 (E)
Key
a considered as riser
b considered as base
1 inlet
2 outlet
3 invert
4 inside diameter
5 benching
6 main flow channel
Figure 5a — Examples of a one-piece shallow chamber
Key
a riser
b base
c connection
1 inlet
2 outlet
3 invert
4 inside diameter
5 benching
6 main flow channel
Figure 5b — Example of shallow chamber with separate components
prEN 13598-1:2025 (E)
4 Symbols and abbreviations
4.1 Symbols
For the purposes of this document, the following symbols apply.
A length of engagement
d mean outside diameter
em
d nominal outside diameter
n
d mean inside diameter of socket
sm
e minimum wall thickness
min
e2 wall thickness of a socket
e wall thickness in the groove area
L length of spigot
y determined value when tested
H vertical deflection of the main channel diameter
W horizontal deflection of the main channel diameter
prEN 13598-1:2025 (E)
4.2 Abbreviations
For the purposes of this document, the following abbreviations apply.
DN nominal size
DN/ID nominal size, inside diameter related
DN/OD nominal size, outside diameter related
DSC differential scanning calorimetry
IR infrared
MFR melt mass-flow rate
NA not applicable
OIT oxidation induction time
PE polyethylene
PP polypropylene
PVC-U unplasticized poly(vinyl chloride)
SN nominal ring stiffness
5 Material
5.1 Ancillary fittings
The material shall conform to EN 1401-1, EN 1852-1, EN 12666-1, EN 13476-1, EN 13476-3 or
EN 14758-1 as applicable.
5.2 Shallow chambers
The material shall conform with the requirements specified in Annex A.
Alternatively, materials complying with EN 1401-1, EN 1852-1, EN 12666-1, EN 13476-1, EN 13476-3,
EN 13598-2 or EN 14758-1 may be used without testing in accordance with Annex A.
If recyclates are used, the requirements specified in Annex B apply.
5.3 Sealing ring retaining components
It is permitted that sealing rings are retained using means made from polymers other than PVC-U, PP or
PE.
6 General characteristics
6.1 Appearance
When viewed without magnification the following requirements apply:
— the internal and external surfaces shall be smooth, clean and free from grooving, blistering,
impurities and pores and any other surface irregularity likely to prevent their conformity with this
document;
— spigots shall be cleanly cut and the ends of pipes and fittings shall be square to their axis.
prEN 13598-1:2025 (E)
6.2 Colour
Ancillary fittings if manufactured in layers shall have their surface layers coloured throughout. The
outside layer of ancillary fittings should preferably be black, orange brown (approximately RAL 8023 [7])
or dusty grey (approximately RAL 7037 [7]). Other colours may be used.
6.3 Assemblies
Ancillary fitting and shallow chamber assemblies can be a combination of two or more plastics
components, provided that all of the requirements of this document are met.
The complete ancillary fitting or shallow chamber assembly may also include items which are not
specified in this document (for example covers, frames and gratings complying with the relevant part of
EN 124.
7 Geometrical characteristics
7.1 General
The manufacturer shall specify the relevant geometrical characteristics and the tolerances.
All dimensions shall be measured in accordance with EN ISO 3126.
The nominal diameter of ancillary fittings shall be that of the pipe which can be connected to its outlet
except that in the case of mechanical saddles the size of the main pipe and branch connection shall be
specified.
The nominal diameter of the riser (DN/ID or DN/OD) shall be used to designate the nominal size of
shallow chambers.
7.2 Design lengths
The design lengths shall be declared by the manufacturer.
NOTE The design lengths (Z-lengths) are intended to assist in the design of moulds and are not intended to be
used for quality control purposes. ISO 265-1 [8] can be used as a guideline.
7.3 Dimensions of ancillary fittings
The wall thickness of the body and the spigot (emin) for pipe connections shall not be less than those
specified in EN 1401-1, EN 1852-1, EN 12666-1, EN 13476-1, EN 13476-2, EN 13476-3 or EN 14758-1
for a fitting or component of the same material and nominal diameter.
The wall thicknesses of sockets (e and e ) shall not be less than those specified in EN 1401-1, EN 1852-1,
2 3
EN 12666-1, EN 13476-1, EN 13476-2, EN 13476-3 or EN 14758-1 for a socket of the same material and
nominal diameter.
The diameters, length of sockets (A) and length of spigots (L ) shall not be less than those specified for a
1,
fitting in EN 1401-1, EN 1852-1, EN 12666-1, EN 13476-1, EN 13476-2, EN 13476-3 or EN 14758-1.
7.4 Dimensions of shallow chambers
The wall thickness of the base body including the first 300 mm of any integral riser measured from the
top of the outlet shall be specified by the manufacturer. For pipe connections the wall thickness of the
spigot/socket shall not be less than those specified in EN 1401-1 or EN 13476 (all parts)
For all separate riser components and integral risers above the first 300 mm the wall thickness shall be
determined by the stiffness requirements in Table 3.
prEN 13598-1:2025 (E)
NOTE The requirement for wall thickness of the spigot/socket for pipe connections is not applicable for riser
to base assembly or sockets or spigots of risers.
Socket (d ) and spigot (d ) diameters, length of engagement (A), length of spigots (L ) and their
sm em 1
tolerances shall enable compatibility to pipe work in accordance with the product standards of the pipes
that they are intended to be connected to.
For vertical assemblies the diameters and lengths of sockets shall be specified by the manufacturer.
As designed or when tested in the factory, joints for base connections to pipework shall have a continuity
of invert within the following calculated maximum tolerances:
— ≤ DN/OD 315 or DN/ID 300: maximum step 6 mm;
— > DN/OD 315 or DN/ID 300: maximum step 0,02 mm × DN limited to 30 mm.
7.5 Additional requirements for sealed access fittings
Circular openings in access fittings shall have a minimum diameter greater than 50 % of the internal
diameter of the fitting subject to a minimum of 90 mm.
Rectangular access fittings shall have minimum opening dimensions of 150 mm and 90 mm measured on
their longitudinal and transverse centre lines.
8 Mechanical characteristics
Using the indicated parameters, the products covered by this document shall have mechanical
characteristics conforming to the requirements given in Tables 1, 2 and 3 as applicable:
— Table 1 — Mechanical characteristics of sealed access fittings and rodding tees;
— Table 2 — Mechanical characteristics of mechanical saddles;
— Table 3 — Mechanical characteristics of shallow chambers.
Additionally when a product covered by this document is made as a fabricated fitting, it shall comply
with:
— Table 4 — Mechanical characteristics of fabricated fittings.
Plastics rodding point covers shall comply with the EN 124 (all parts) or comply with the EN 1253 (all
parts) as applicable.
Table 1 — Mechanical characteristics of sealed access fittings and rodding tees
Test parameters
Characteristic Requirements Test method
Parameter Value
Impact strength No damage Temperature (°C) 0 EN ISO 13263
(drop test) Drop height, (mm): 1 000
dn = 110 mm 1 000
d = 125 mm 500
n
dn = 160 mm 500
d = 200 mm Mouth of socket
n
Point of impact
prEN 13598-1:2025 (E)
Table 2 — Mechanical characteristics of mechanical saddles assembled on pipes
Test parameters
Characteristic Requirements Test method
Parameter Value
Resistance to No splitting and/or Temperature (°C) (23 ± 5) Load to be applied
a
vertical load cracking. to the top of the
Load, F (kN) 15
riser pipe in
The vertical pipe shall
Duration (min) 5
accordance with
not pass the pipe stop
Annex B
Mechanical No sign of splitting, Temperature (°C) (23 ± 5) Annex B
strength of cracking or separation
Duration (min) 2 × 5
saddle
Minimum load for inlet pipe, F 0,15
assembled to
(kN):
b, c
pipe
Tightness under No leakage Table 6 Table 6 Annex B
deformation
a
This test is only required for 90° saddles installed vertically.
b
The assembly shall be in accordance with the manufacturer's instructions.
c
The force or displacement as applied shall be applied firstly in the longitudinal direction and subsequently in the
transverse direction.
Table 3 — Mechanical characteristics of shallow chambers
Test parameters
Characteristic Requirements Test method
Parameter Value
Ring stiffness of riser No cracking, Shall conform to EN ISO 13268 EN ISO 13268
2 a
stiffness ≥ 0,7 kN/m
b f
Structural integrity of base Test (23 ± 2) EN ISO 13267
No collapse or cracks
temperature (°C)
Vertical deflection H of the
Duration (h)
c, d
−0,2
main channel diameter ≤ 5 %
e
Internal negative
pressure (bar)
Horizontal deflection W of the
e
main channel diameter ≤ 10 %
Resistance to vertical loading Deflection of horizontal Force 15,0 Annex C and
g
(complete assembly) dimensions not to exceed 6 %. applied, F (kN) EN 1253-2:2015,
1,0
5.3
Deflection of cover shall conform Loading
to EN 1253-2:2015, 5.3 speed, v (kN/s)
No cracking
a
Attention is drawn to the intended use detailed in the scope.
b
For testing purposes, the assembly shall include at least the base component of the shallow chamber. The negative
pressure shall be maintained by external means throughout the 1008 h test.
c 5 2
1 bar = 10 N/m = 0,1 MPa.
d
The value of −0,2 bar is based on the need to safeguard structural integrity where there is no groundwater present
e
When the deflection in the horizontal direction (width of main channel) is ≤ 10 %, normal inspection and cleaning
equipment can be entered in the sewer system. When the deflection in the vertical direction is ≤ 5 %, effects on flow
performance are negligible.
f
The test is carried out according the standard without the extrapolation in accordance with EN ISO 13267:2023,
Annex A.
g
Only applicable if a load is applied via the cover and frame directly to the complete assembly.
prEN 13598-1:2025 (E)
Table 4 — Mechanical characteristics of fabricated fittings
Test parameters
Characteristic Requirements Test method
Parameter Value
Flexibility or No sign of splitting, Test period, t (min) 15 EN ISO 13264
mechanical cracking,
Minimum 170
a, b
strength separation and/or
flexibility, (mm)
leakage
OR
Test period, t (min) 15
Minimum moment for: 3 −6
0,15 × [DN] × 10 kN•m
DN ≤ 250
0,01 × [DN] kN•m
DN > 250
a
Only for fabricated fittings made from more than one piece where a sealing retaining means or a separate cover are
not considered as a piece. This requirement also applies to any fusion or adhesive jointing during the manufacture
of shallow chambers.
b
Either the specified moment or the specified displacement becomes the determining factor, whichever is reached
first.
9 Physical characteristics of ancillary fittings
9.1 Injection moulded fittings
The physical characteristics for injection-moulded fittings shall conform to EN 1401-1, EN 1852-1,
EN 12666-1, EN 13476-2, EN 13476-3 or EN 14758-1 as applicable.
9.2 Fabricated fittings
When tested in accordance with the test method as specified in Table 5 any fabricated fitting shall comply
with the requirement given in Table 5.
Table 5 — Physical characteristics of fabricated fittings
Test parameters
Characteristic Requirements Test method
Parameter Value
a
Water tightness No leakage Water pressure (bar) 0,5 EN ISO 13254
Duration (min) ≥ 1,0
a
Only for fabricated fittings made from more than one piece. A sealing ring retaining means is not considered as a piece.
It is also possible to test with air or vacuum but in the case of dispute, the test shall be performed with water.
An indirect test with vacuum, can be carried out in accordance with EN ISO 13259:2020, Condition A, with negative test
pressure of −0,3 bar for a duration of 1 min. At the end of the test the negative pressure shall be ≤ −0,27 bar.
An indirect test with air can be carried out with an air pressure of +0,2 bar gauge for a duration of 1 min.
10 Performance requirements
When tested in accordance with the test methods as specified in Tables 6 and 7 using the indicated
parameters, the joints and the system shall have characteristi
...