SIST EN 12211:2016
(Main)Windows and doors - Resistance to wind load - Test method
Windows and doors - Resistance to wind load - Test method
This European Standard defines the method of test to determine the resistance to wind load for completely assembled windows and doors of any materials when submitted to positive and negative test pressures.
This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufactures specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to joints between the window or door frame and the building construction. This standard is not intended to evaluate strength of the glass.
Fenster und Türen - Widerstandsfähigkeit bei Windlast - Prüfverfahren
Diese Europäische Norm legt das Prüfverfahren zur Bestimmung des Widerstands gegen Windlast von vollständig zusammengebauten Fenstern und Türen aller Werkstoffe unter Einwirkung von positiven und negativen Prüfdrücken fest.
Das Prüfverfahren berücksichtigt die Nutzungsbedingungen von Fenstern und Türen, die in Übereinstimmung mit den Festlegungen des Herstellers und den Anforderungen der ent¬sprechenden Europäischen Normen und Regelwerke der Baupraxis eingebaut werden.
Diese Europäische Norm gilt nicht für Fugen, die zwischen dem Fenster- bzw. Türrahmen und dem Baukörper liegen. Die Bewertung der Glasfestigkeit ist nicht Gegenstand dieser Norm.
Fenêtres et portes - Résistance au vent - Méthode d'essai
La présente Norme européenne définit la méthode d'essai permettant de déterminer la résistance au vent des fenêtres et des portes complètement assemblées, quels que soient leurs matériaux constitutifs, lorsqu'elles sont soumises à des pressions d'essai positives et négatives.
La présente méthode d'essai est conçue pour tenir compte des conditions d'utilisation, lorsque la fenêtre ou la porte est installée conformément aux prescriptions du fabricant et aux exigences des normes européennes et des règles de mise en œuvre concernées.
La présente norme ne s'applique pas aux joints entre le dormant de la porte ou de la fenêtre et la partie constitutive du bâtiment. La présente norme n'est pas destinée à évaluer la résistance du verre.
Okna in vrata - Odpornost proti obremenitvi z vetrom - Preskusna metoda
Ta evropski standard obravnava preskusno metodo za ugotavljanje odpornosti proti obremenitvam z vetrom za v celoti sestavljena okna in vrata iz katerega koli materiala pri izpostavljenosti pozitivnim ali negativnim preskusnim tlakom.
Preskusna metoda je zasnovana tako, da upošteva pogoje uporabe, ko sta okno ali vrata nameščena v skladu s specifikacijami proizvajalca ter zahtevami ustreznih evropskih standardov in pravili ravnanja.
Ta evropski standard se ne uporablja za spoje med okenskim ali vratnim okvirjem in gradbeno konstrukcijo. Ta standard ni namenjen za ocenjevanje trdnosti stekla.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Okna in vrata - Odpornost proti obremenitvi z vetrom - Preskusna metodaFenster und Türen - Widerstandsfähigkeit bei Windlast - PrüfverfahrenFenêtres et portes - Résistance au vent - Méthode d'essaiWindows and doors - Resistance to wind load - Test method91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 12211:2016SIST EN 12211:2016en,fr,de01-maj-2016SIST EN 12211:2016SLOVENSKI
STANDARDSIST EN 12211:20011DGRPHãþD
SIST EN 12211:2016
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12211
March
t r s x ICS
{ sä r x rä w r Supersedes EN
s t t s sã t r r rEnglish Version
Windows and doors æ Resistance to wind load æ Test method Fenêtres et portes æ Résistance au vent æ Méthode d 5essai
Fenster und Türen æ Widerstandsfähigkeit bei Windlast æ Prüfverfahren This European Standard was approved by CEN on
{ January
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s x CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s t t s sã t r s x ESIST EN 12211:2016
EN 12211:2016 (E) 2 Contents Page European foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 4 4 Principles of test . 5 5 Apparatus . 5 6 Preparation of test specimen . 6 6.1 Set-up of the test specimen . 6 6.2 Set-up of measuring devices for frontal deflection . 6 7 Test procedure . 6 7.1 Preliminaries . 6 7.2 Deflection test. 7 7.2.1 General . 7 7.2.2 Positive pressure . 7 7.2.3 Negative pressure . 7 7.3 Repeated pressure test . 7 7.4 Safety test . 7 8 Deflection . 8 9 Repeated pressure . 8 10 Safety test . 8 11 Test report . 8 Annex A (informative)
Deflection measurements . 10 Annex B (informative)
Resistance to wind load test sequence . 14 Bibliography . 15
SIST EN 12211:2016
EN 12211:2016 (E) 3 European foreword This document (EN 12211:2016) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2016, and conflicting national standards shall be withdrawn at the latest by September 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12211:2000. The revision of this European Standard clarifies only the test method and does not affect existing test evidence of EN 12211:2000. This European Standard is one of a series of standards for windows and doors. In comparison with EN 12211:2000, the following significant changes were made: a) Clause 3: Supplement of definition “closing condition”; b) Sub-clause 3.2: Simplification of definition “test pressure”; c) Sub-clause 5.4: Revision of definition „accuracy“; d) Sub-clause 7.1: Addition of „closing condition“; e) Clause 11: Supplement of necessary description of test specimen; f) Annex A: Renumeration of figures; g) Annex A: Revision of A.1 and A.2; h) Annex A: Supplement of Figure A.4 (new) – Measuring points on single and double leaf doors (example); i) Annex B: Revision of Figure B.1. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 12211:2016
EN 12211:2016 (E) 4 1 Scope This European Standard defines the test method to determine the resistance to wind load for completely assembled windows and pedestrian doorsets of any materials when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufacture's specification and the requirements of relevant European Standards and codes of practice. This European Standard does not apply to joints between the window or door frame and the building construction. This European Standard is not intended to evaluate strength of the glass. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1026, Windows and doors — Air permeability — Test method EN 12519, Windows and pedestrian doors — Terminology 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12519 and the following apply. 3.1 closing condition 3.1.1 closed movable parts rest in or at the fixed parts in a way in which they may be fastened (latched and/or locked) 3.1.2 fastened where the movable part is restrained at one or more points and shall be described by at least one of the two as listed below 3.1.2.1 latched movable part is returned to its closed position and restrained by either a) a self - engaging fastener or b) a roller catch or c) a latch 3.1.2.2 locked movable part is further restrained in the closed position by additional operations (of e.g. handle, key, automatic devices or electronic devices) to engage integrated locking devices (e.g. nutbolts or deadbolts) which will affect the product’s characteristics SIST EN 12211:2016
EN 12211:2016 (E) 5 3.1.3 secured any action(s) which prevent unauthorised release of the fastening device(s) to allow exit or entry (e.g. child safety, burglary) 3.2 frontal displacement movement of a point on a frame member measured normal to the member 3.3 frontal deflection maximum frontal displacement of a frame member minus half the sum of the frontal displacements at each end of the member 3.4 relative frontal deflection frontal deflection of a frame member divided by the length of the member over which the frontal deflection was measured, e.g. distance between the ends of the member 3.5 test pressure difference between the static air pressures inside and outside of the test chamber Note 1 to entry: The test pressure is positive if the static air pressure inside the chamber of the test apparatus is higher than that outside the test chamber. Note 2 to entry: The test pressure is negative if the static air pressure inside the chamber of the test apparatus is lower than that out
...