ISO/FDIS 13373-7
(Main)Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
- Abstract
ISO 13373-7:2017 gives guidelines for specific procedures to be considered when carrying out vibration diagnostics of various types of machine sets in hydraulic power generating and pump-storage plants (hydropower units). It is intended to be used by condition monitoring practitioners, engineers and technicians and provides a practical step-by-step vibration-based approach to fault diagnosis. In addition, it includes a number of examples for a range of machine and component types and their associated fault symptoms.
- Status
- Not Published
- Technical Committee
- ISO/TC 108/SC 2 - Measurement and evaluation of mechanical vibration and shock as applied to machines, vehicles and structures
- Drafting Committee
- ISO/TC 108/SC 2/WG 10 - Basic techniques for vibration diagnostics
- Current Stage
- 5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
- Start Date
- 18-Nov-2026
- Due Date
- 18-Nov-2026
- Completion Date
- 18-Nov-2026
Buy Documents
ISO/FDIS 13373-7 - Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
REDLINE ISO/FDIS 13373-7 - Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
ISO/FDIS 13373-7 is an ISO document for vibration condition monitoring and diagnostics of machine sets in hydraulic power generating and pump-storage plants, often called hydropower units. It gives condition monitoring practitioners, engineers and technicians a practical, step-by-step way to diagnose faults from vibration data. The document links measurement methods, operational data, fault tables and a diagnostic flowchart so the user can relate observed vibration patterns to likely machine problems.
What does ISO/FDIS 13373-7 specify?
ISO/FDIS 13373-7 specifies procedures to consider when carrying out vibration diagnostics on hydropower units. The document is aimed at field diagnosis after an anomaly has been detected, and it uses flowcharts, fault tables and symptom tables as the main diagnostic tools.
The document is organized into these main parts:
- Clause 1 - Scope
- Clause 2 - Normative references
- Clause 3 - Terms and definitions
- Clause 4 - Hydropower vibration
- Clause 5 - Vibration measurements
- Clause 6 - Initial analysis
- Clause 7 - Specific analysis of hydropower units
- Clause 8 - Additional diagnostics
- Annex A - fault table for vibration analysis
- Annex B - vibration diagnostic process for faults
- Annex C - examples of vibration problems
| Annex | What it covers |
|---|---|
| Annex A | Normative fault table for vibration analysis of hydropower units |
| Annex B | Normative diagnostic flowchart and method for finding fault causes |
| Annex C | Informative examples of vibration problems and their physical explanations |
What are the key requirements of ISO/FDIS 13373-7?
Vibration measurement has to reflect the unit as a whole
ISO/FDIS 13373-7 says a hydropower unit shall be analysed as one dynamic unit, because the hydraulic, electrical and mechanical parts interact strongly. All vibration quantities shall be measured simultaneously in all bearing planes. In practice, this means the user should not diagnose one bearing or one component in isolation when the vibration behaviour is coupled across the machine set.
The document distinguishes two main measurement types:
- Shaft relative vibration, measured with non-contacting proximity probes
- Bearing housing vibration, measured with seismic transducers on non-rotating parts
That distinction matters because each view shows different fault behaviour, and the best diagnosis often comes from comparing both.
Measurement setup and timing matter
ISO/FDIS 13373-7 gives practical guidance on probe placement, repeatability and frequency range. Temporary proximity probes should be placed consistently, and the document notes that electrical and mechanical runout can affect the reading. It also states that the residual runout should be documented and used to correct rotational speed components when a phase reference is available.
For bearing housing measurements, the document calls for orthogonal radial transducers on each bearing housing and an axial transducer where thrust bearing behavior or a braced bearing needs it. It also warns that some systems cannot measure low enough for hydropower units, so low-frequency capability and sufficient measurement duration are important.
Operating conditions must be recorded with the vibration data
ISO/FDIS 13373-7 requires operational data to be measured and stored together with vibration data so that vibration can be correlated with machine state. The document names several relevant parameters, including rotational speed, load, head, tail water level, wicket gate opening and bearing oil temperature.
A hydraulic operating point shall be defined by at least two operational parameters and by the operating mode, such as generating, pumping or transient. For variable-speed machines, actual rotational speed is needed, and the direction of rotation matters for phase interpretation. In practice, this lets the diagnostician separate a true fault from a normal change in operating condition.
Initial analysis starts with the machine history and configuration
Clause 6 says the first step shall be to collect the design configuration of the machine and the history of previous anomalies. The document uses this as the basis for judging safety concerns, vibration severity, operating history and the likely consequences of leaving the condition uncorrected.
If the dynamic behaviour changes, investigations and tests shall be carried out to find the reason. This is important because hydropower faults often develop slowly, so trend information and historical context are central to the diagnosis.
The hydraulic, mechanical and electrical parts should be assessed together
Clause 7 says hydropower units are often individual prototypes, so comparison with another machine is not always useful unless the boundary conditions are similar. The assessment shall therefore consider the actual design configuration and operating conditions.
The document also states that the generator or motor part is normally directly coupled to the hydraulic part, so the combined system should be analysed. Diagnosing only the hydraulic side or only the electrical side is usually not enough, except in units with a gearbox or a clutch between prime mover and driven machine.
Annex A and Annex B provide the core diagnostic tools
Annex A shall be followed in vibration analysis of hydropower units. It lists common faults and the vibration features that tend to accompany them, such as 1× components, harmonics, subharmonics, phase changes and changes in vibration with load or speed. Annex B shall be used for diagnostic purposes and gives the methodical field workflow.
That workflow includes:
- visual inspection
- measurement of vibration and operating parameters
- trend analysis
- correlation with load and operating state
- extended spectral and phase analysis when needed
- resonance testing where useful
In practice, this means the user should move from quick screening to deeper analysis only as needed, rather than starting with complex testing.
What terms does ISO/FDIS 13373-7 define?
- Hydropower units - machine sets in hydraulic power generating and pump-storage plants, including the coupled hydraulic and electrical parts that are diagnosed together.
- Shaft relative vibration - the movement of the rotating shaft relative to the bearing housing, usually measured with proximity probes.
- Bearing housing vibration - the absolute vibration of the non-rotating bearing housing, usually measured with accelerometers or velocity transducers.
- Operational point - the hydraulic condition of the unit, defined by at least two operating parameters and the operating mode.
- Runout - electrical and mechanical measurement error that can affect proximity probe readings.
- Resonance speed - a speed at which a natural frequency and an excitation frequency coincide, producing a strong vibration response.
- Diagnostic flowchart - the structured decision path used to identify likely fault causes from measured vibration and operating data.
Who uses ISO/FDIS 13373-7?
ISO/FDIS 13373-7 is intended for condition monitoring practitioners, engineers and technicians working on hydropower units. It is used by people who collect vibration data, interpret spectra and phase information, and decide what additional checks are needed.
Typical tasks include fault diagnosis, trend review, correlation of vibration with operating conditions, and planning maintenance actions. It is relevant in hydraulic power generating plants and pump-storage plants where machine sets show slowly developing or operating-condition-dependent vibration changes.
What changed in ISO/FDIS 13373-7 from the previous edition?
ISO/FDIS 13373-7 cancels and replaces ISO 13373-7:2017. The document states that it has been technically revised.
The changes listed in the foreword are:
- the introduction was updated
- several recommendations were changed into requirements throughout the document
- Table A.2 was added
- Table B.1 was deleted
Which standards are used with ISO/FDIS 13373-7?
ISO/FDIS 13373-7 cites these normative references:
- ISO 2041 - vocabulary for mechanical vibration, shock and condition monitoring
- ISO 13372 - vocabulary for condition monitoring and diagnostics of machines
- ISO 13373-1 - general procedures for vibration condition monitoring
- ISO 13373-2 - processing, analysis and presentation of vibration data
- ISO 21940-2 - vocabulary for rotor balancing
The document also points users to related standards and companion parts that add context:
- ISO 13373-3 - general vibration diagnosis guidance and systematic diagnostic methods
- ISO 17359 - general condition monitoring guidelines
- ISO 20816-1 and ISO 20816-5 - evaluation of machine vibration, including hydropower machine sets
- ISO 20816-5 is identified in the introduction as the place where acceptable vibration values for hydropower units are given
- ISO 13373-1 and ISO 13373-2 are also referenced in Clause 5 for selecting transducers and measurement systems
- ISO 13373-3 is used in the introduction and Clause 6 as the basis for initial analysis and broader diagnostic procedures
What does the ISO/FDIS 13373-7 document contain?
ISO/FDIS 13373-7 contains a fault table, a diagnostic flowchart, and worked examples that help users interpret vibration behavior in hydropower units. Annex A provides the fault table and a second table of observable symptoms, while Annex B gives the step-by-step diagnostic process and the flowchart used in the field.
Annex C illustrates specific vibration problems such as mechanical unbalance, magnetic unbalance, hydraulic unbalance, shaft misalignment, lateral rotor resonance, static radial pull, stator vibration, cavitation and rubs. These examples help the reader connect measured shaft motion, bearing housing vibration, phase change and frequency content to likely physical causes.
Relations
- Effective Date
- 10-Dec-2022
Buy Documents
ISO/FDIS 13373-7 - Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
REDLINE ISO/FDIS 13373-7 - Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
ISO/FDIS 13373-7 is a draft published by the International Organization for Standardization (ISO). Its full title is "Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7: Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants". This standard covers: ISO 13373-7:2017 gives guidelines for specific procedures to be considered when carrying out vibration diagnostics of various types of machine sets in hydraulic power generating and pump-storage plants (hydropower units). It is intended to be used by condition monitoring practitioners, engineers and technicians and provides a practical step-by-step vibration-based approach to fault diagnosis. In addition, it includes a number of examples for a range of machine and component types and their associated fault symptoms.
ISO 13373-7:2017 gives guidelines for specific procedures to be considered when carrying out vibration diagnostics of various types of machine sets in hydraulic power generating and pump-storage plants (hydropower units). It is intended to be used by condition monitoring practitioners, engineers and technicians and provides a practical step-by-step vibration-based approach to fault diagnosis. In addition, it includes a number of examples for a range of machine and component types and their associated fault symptoms.
ISO/FDIS 13373-7 is classified under the following ICS (International Classification for Standards) categories: 17.160 - Vibrations, shock and vibration measurements. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/FDIS 13373-7 has the following relationships with other standards: It is inter standard links to ISO 13373-7:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO/FDIS 13373-7 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Hydropower vibration
- 5 Vibration measurements
- 5.1 General
- 5.2 Instrumentation
- 5.3 Measurement of machine operational parameters
- 6 Initial analysis
- 7 Specific analysis of hydropower units
- 8 Additional diagnostics
- Annex A
- Annex B
- Annex C
- Bibliography
Introduction
This document provides guidelines for the procedures to be considered when carrying out vibration diagnostics of machine sets in hydraulic power generating and pump-storage plants, shortly named hydropower units. It is intended to be used by vibration practitioners, engineers and technicians and it provides them with useful diagnostic tools which include the use of diagnostic flowcharts and fault and symptom tables. The material included presents the most basic, logical and intelligent steps that should be taken when diagnosing problems associated with these machine types. Acceptable vibration values for hydropower units, however, are contained in ISO 20816-5. ISO 13373-1 presents the basic procedures for analysing narrow-band vibration signals. It includes the types of transducers to be used, their ranges, their recommended mounting locations on various machine types, on-line and periodic vibration systems and potential machinery problems. ISO 13373-2 includes descriptions of the signal conditioning equipment that is required, the time and frequency domain techniques that can be used and the waveforms and signatures that represent the most common machinery operating phenomena or faults encountered when performing vibration signature analysis.
ISO 13373-3 describes some procedures to determine the causes of vibration problems common to all types of rotating machines. It includes systematic approaches to characterize vibration effects, the diagnostic tools available, tools needed for particular applications and recommendations on how the tools are to be applied to different machine types and components. ISO 13373-3 does not preclude the use of other diagnostic techniques.
Note that ISO 17359 indicates that diagnostics can be a) started after detection of an anomaly during machine monitoring, or b) carried out in parallel with machine monitoring.
This document considers only list item a) where diagnostics are performed after an anomaly has been detected. Moreover, this document focusses mainly on the use of flowcharts, fault and symptom tables as diagnostic tools, since it is felt that these are the tools that are most appropriate for use in the field. The fault tables given in Annex A present a list of the most common machinery faults that occur, as well as their manifestation in the machine and vibration data, while the symptom tables provide the main distinguishing vibration features of those machinery faults. When used with the flowcharts, the tables assist with the identification of machinery faults.
When approaching a machinery problem that manifests itself as a high or erratic vibration signal, the diagnosis of the problem should be carried out in a well-thought-out systematic manner. This document and ISO 13373-3 achieve that by providing guidance regarding selection of the measuring and analysis tools, their use and the recommended step-by-step procedures that can be used for the diagnosis of problems associated with various types of machine sets in hydraulic power generating and pump-storage plants. The diagnostic process table methodology presents a structured procedure for a person in the field to diagnose a fault and find its cause. The step-by-step procedure guides the practitioner in the vibration diagnostics of the machine anomaly in order to detect the probable root cause.
FINAL DRAFT International Standard ISO/FDIS 13373-7:2026(en) Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 7:
Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
1 Scope
This document sets out the specific procedures to be considered when carrying out vibration diagnostics of various types of machine sets in hydraulic power generating and pump-storage plants (hydropower units). It is intended to be used by condition monitoring practitioners, engineers and technicians and provides a practical step-by-step vibration-based approach to fault diagnosis. In addition, it includes several examples for a range of machine and component types and their associated fault symptoms.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 2041, Mechanical vibration, shock and condition monitoring — Vocabulary ISO 13372, Condition monitoring and diagnostics of machines — Vocabulary ISO 13373-1, Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 1:
General procedures ISO 13373-2, Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 2:
Processing, analysis and presentation of vibration data ISO 21940-2, Mechanical vibration — Rotor balancing — Part 2: Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 2041, ISO 13372 and ISO 21940-2 apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https:// www .electropedia .org/
- ISO Online browsing platform: available at https:// www .iso .org/ obp
4 Hydropower vibration
Vibration measurements mainly consist of quantifying the oscillation of the rotating shaft at the guide bearings relative to the bearing housing (e.g. shaft relative vibration) and the absolute vibration of the bearing housing itself (e.g. bearing housing vibration) which is representative for non-rotating parts.
ISO/FDIS 13373-7:2026(en) Unlike other heavy rotating equipment, such as gas turbines, compressors and pumps, hydropower units are rigid without flexible couplings between the components and normally operate below their first resonance speed. A hydropower unit shall therefore be analysed as one dynamic unit, which means that all vibration quantities shall be measured simultaneously in all bearing planes. Hydropower units are influenced by - mechanical unbalance, - hydraulically excited forces acting on the turbine runner, - magnetically interacting forces between the stator and rotor, - mechanical forces in the bearings (bearing faults), - fluid-film instability, and - contact between rotating and non-rotating parts.
Any of these forces can cause mechanical vibration and deflection. The magnitude and behaviour of the vibration vary depending on the type of hydropower unit, general layout, bearing design, foundation, rotational speed, etc. As the forces can seldom be measured directly, or as measuring the forces is much more complex, vibration is used as an indirect indicator. Vibration analyses are based on the detection and estimation of mechanical forces by observing the resulting vibrations.
5 Vibration measurements
5.1 General
Hydropower units normally have a long lifespan with a stable and solid behaviour. Possible faults in hydro plants usually develop slowly. Occasional monitoring is suitable to detect slowly developing faults and therefore, temporarily installed measurement systems for periodic, random or infrequent monitoring can be sufficient for being able to obtain enough information to perform an initial analysis as described in ISO 13373-3. But those systems are not sufficient for a detailed diagnosis of slowly developing faults as described in ISO 13373-2.
Trending of parameters should be performed regularly to detect changes in the machine vibration over longer periods of time. For such trend analyses, continuous long-term monitoring by a permanent monitoring system is preferred. A permanent monitoring system also helps to give protection to the machine against failures (e.g. bearing breakdowns). Periodic measurements with additional transducers give valuable information for the condition evaluation and useful information to enable planning of maintenance work. Condition-based monitoring can be considered and applied as described in ISO 17359. This can lead to additional effort, including - installation of additional transducers, - monitoring of machine operating parameters influencing the vibration behaviour, - more detailed analysis, and - continuous on-line measurement with appropriate data storage and acquisition system. More information relevant to measuring hydropower unit vibration is given in the documents listed in the Bibliography.
ISO/FDIS 13373-7:2026(en)
5.2 Instrumentation
Two principal kinds of vibration measurement are common, which provide complementary information:
a) shaft relative vibration, measured with non-contacting proximity probes that are mounted at or near the bearings (e.g. inductive, capacitive and eddy current probes); b) bearing housing vibration, measured with seismic transducers (e.g. accelerometers or velocity transducers) that are mounted on non-rotating parts of the bearing housing. In addition to vibration measurements, transducers can also be installed to measure dynamic pressure, air gap and, by means of strain gauges, stress. These parameters can be used to correlate the cause and effect of an event.
Large hydropower installations normally include proximity probes at each bearing. However, if this is not the case, it is advisable to install two temporary proximity probes at each bearing position with their orientation in the radial plane orthogonal to each other, see Figure 1. Figure 1 — Example of measurement locations and directions on a vertical hydropower unit When using temporarily installed proximity probes, the following shall be noted:
- Relative vibration transducers can be susceptible to electrical and mechanical runout which can differ based upon probe axial location related to the shaft. Axial locations shall be chosen to allow repeatable installations for monitoring and to reduce the effects of this measurement error.
- The residual total electrical and mechanical runout shall be documented and used to correct rotational speed vibration components when an appropriate phase reference signal is available.
- Temporary radial vibration transducer locations shall be consistent between measurement events.
- For full information about bearing housing vibration, an installation shall contain two radial seismic transducers in orthogonal directions on each bearing housing and one seismic transducer in axial direction for thrust bearings or a bearing braced against a vibrating structure like the turbine head cover. The commonly used signal output is vibration velocity, measured directly with velocity transducers or measured with accelerometers and signal integration.
- Some acceleration and velocity measuring systems are only able to measure vibration at frequencies down to 10 Hz, which is not suitable in hydropower units where the rotational speed is normally below
ISO/FDIS 13373-7:2026(en) 600 r/min. The recommended minimum frequency is 0,1 times the rotational frequency for reaction turbines and pumps and 0,4 times the rotational frequency for impulse turbines. - All signals shall be measured simultaneously with measurement duration sufficient to characterize such low frequencies.
- Adding a phase mark transducer for a trigger provides a method to synchronize the measurements and to give phase reference at each measurement point.
International Standards are available to help assessing the vibration severity for the described types of measurement, in particular ISO 20816-1 and ISO 20816-5.
Description of transducer and measurement systems as well as the specification of techniques are given in ISO 13373-1 and ISO 13373-2, which shall be considered when selecting an appropriate transducer and measurement system.
5.3 Measurement of machine operational parameters
Hydropower machine operational parameters [e.g. rotational speed, load, head, tail water level, opening of main regulation device (e.g. wicket gate opening) and bearing oil temperature] can influence the machine vibration characteristics. For a reliable diagnosis, it is important to measure and to store these data simultaneously so as to be able to correlate vibration and the operational state. A hydraulic operational point shall be defined by at least two operational parameters (e.g. head and discharge) and operational mode (e.g. generating, pumping, transient). For variable speed machines, knowledge of the actual rotational speed is required.
The direction of rotation is also an important parameter, as it is required to interpret the phase of synchronous vibration correctly.
6 Initial analysis
The first step shall be to collect the design configuration of the machine and the history of previous anomalies. This initial analysis can be performed using the guidelines given in ISO 13373-3:2015, Annex A, which indicates that it shall identify safety concerns, the presence of high vibration and its vibration severity, the history, effects of operating parameters and the consequences of failing to take corrective actions. All this is used as a basis to judge the risk in operating the machine. When changes in dynamic behaviour are detected, investigations and tests shall be performed to find the reason for the changes.
7 Specific analysis of hydropower units
Hydropower units are often individual prototypes, which makes it difficult to compare one machine to another. The assessment of the vibration state therefore shall consider actual boundary conditions and its design configuration. Long-term trend recording is of significant help. The vibration magnitude is a reaction to the exciting forces. On the hydraulic side (e.g. flow condition in the runner or pressure pulsation on stationary parts) there is a strong dependency on the hydraulic operation point, which shall be defined by two operation parameters [e.g. head and discharge or gate opening (see 5.3)].
NOTE 1 The vibration magnitude alone does not necessarily indicate the stress level in the affected components. A strain gauge measurement either a suitable calculation model, or both, is needed to derive the fatigue impact. The generator or motor part is normally directly coupled to the hydraulic part; therefore, the combined system shall be analysed. A diagnosis of either the hydraulic components or the electrical system alone is
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Hydropower vibration
- 5 Vibration measurements
- 5.1 General
- 5.2 Instrumentation
- 5.3 Measurement of machine operational parameters
- 6 Initial analysis
- 7 Specific analysis of hydropower units
- 8 Additional diagnostics
- Annex A
- Annex B
- Annex C
- Bibliography
Introduction
This document provides guidelines for the procedures to be considered when carrying out vibration diagnostics of machine sets in hydraulic power generating and pump-storage plants, shortly named hydropower units. It is intended to be used by vibration practitioners, engineers and technicians and it provides them with useful diagnostic tools which include the use of diagnostic flowcharts and fault and symptom tables. The material included presents the most basic, logical and intelligent steps that should be taken when diagnosing problems associated with these machine types. Acceptable vibration values for hydropower units, however, are contained in ISO 20816-5. ISO 13373-1 presents the basic procedures for analysing narrow-band vibration signals. It includes the types of transducers to be used, their ranges, their recommended mounting locations on various machine types, online and periodic vibration systems and potential machinery problems. ISO 13373-2 includes descriptions of the signal conditioning equipment that is required, the time and frequency domain techniques that can be used and the waveforms and signatures that represent the most common machinery operating phenomena or faults encountered when performing vibration signature analysis.
ISO 13373-3 describes some procedures to determine the causes of vibration problems common to all types of rotating machines. It includes systematic approaches to characterize vibration effects, the diagnostic tools available, tools needed for particular applications and recommendations on how the tools are to be applied to different machine types and components. ISO 13373-3 does not preclude the use of other diagnostic techniques.
Note that ISO 17359 indicates that diagnostics can be a) a) started after detection of an anomaly during machine monitoring, or b) b) carried out in parallel with machine monitoring.
This document considers only list item a) where diagnostics are performed after an anomaly has been detected. Moreover, this document focusses mainly on the use of flowcharts, fault and symptom tables as diagnostic tools, since it is felt that these are the tools that are most appropriate for use in the field. The fault tables given in Annex A present a list of the most common machinery faults that occur, as well as their manifestation in the machine and vibration data, while the symptom tables provide the main distinguishing vibration features of those machinery faults. When used with the flowcharts, the tables assist with the identification of machinery faults.
When approaching a machinery problem that manifests itself as a high or erratic vibration signal, the diagnosis of the problem should be carried out in a well-thought-out systematic manner. This document and ISO 13373- 3 achieve that by providing guidance regarding selection of the measuring and analysis tools, their use and the recommended step-by-step procedures that can be used for the diagnosis of problems associated with various types of machine sets in hydraulic power generating and pump-storage plants. The diagnostic process table methodology presents a structured procedure for a person in the field to diagnose a fault and find its cause. The step-by-step procedure guides the practitioner in the vibration diagnostics of the machine anomaly in order to detect the probable root cause.
ISO/FDIS 13373-7:2026(en) Condition monitoring and diagnostics of machines — Vibration condition monitoring — — Part 7:
Diagnostic techniques for machine sets in hydraulic power generating and pump-storage plants
1 Scope
This document sets out the specific procedures to be considered when carrying out vibration diagnostics of various types of machine sets in hydraulic power generating and pump-storage plants (hydropower units). It is intended to be used by condition monitoring practitioners, engineers and technicians and provides a practical step-by-step vibration-based approach to fault diagnosis. In addition, it includes several examples for a range of machine and component types and their associated fault symptoms.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 2041, Mechanical vibration, shock and condition monitoring — Vocabulary ISO 13372, Condition monitoring and diagnostics of machines — Vocabulary ISO 13373--1, Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 1:
General procedures ISO 13373--2, Condition monitoring and diagnostics of machines — Vibration condition monitoring — Part 2:
Processing, analysis and presentation of vibration data ISO 21940--2, Mechanical vibration — Rotor balancing — Part 2: Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 2041, ISO 13372 and ISO 21940-2 apply.
ISO and IEC maintain terminologicalterminology databases for use in standardization at the following addresses:
- — IEC Electropedia: available at https://www.electropedia.org/
- — ISO Online browsing platform: available at https://www.iso.org/obp
4 Hydropower vibration
Vibration measurements mainly consist of quantifying the oscillation of the rotating shaft at the guide bearings relative to the bearing housing (e.g. shaft relative vibration) and the absolute vibration of the bearing housing itself (e.g. bearing housing vibration) which is representative for non-rotating parts.
ISO/FDIS 13373-7:2026(en) Unlike other heavy rotating equipment, such as gas turbines, compressors and pumps, hydropower units are rigid without flexible couplings between the components and normally operate below their first resonance speed. A hydropower unit shall therefore be analysed as one dynamic unit, which means that all vibration quantities shall be measured simultaneously in all bearing planes. Hydropower units are influenced by - — mechanical unbalance, - — hydraulically excited forces acting on the turbine runner, - — magnetically interacting forces between the stator and rotor, - — mechanical forces in the bearings (bearing faults), - — fluid-film instability, and - — contact between rotating and non-rotating parts.
Any of these forces can cause mechanical vibration and deflection. The magnitude and behaviour of the vibration vary depending on the type of hydropower unit, general layout, bearing design, foundation, rotational speed, etc. As the forces can seldom be measured directly, or as measuring the forces is much more complex, vibration is used as an indirect indicator. Vibration analyses are based on the detection and estimation of mechanical forces by observing the resulting vibrations.
5 Vibration measurements
5.1 General
Hydropower units normally have a long lifespan with a stable and solid behaviour. Possible faults in hydro plants usually develop slowly. Occasional monitoring is suitable to detect slowly developing faults and therefore, temporarily installed measurement systems for periodic, random or infrequent monitoring can be sufficient for being able to obtain enough information to perform an initial analysis as described in ISO 13373- 3. But those systems are not sufficient for a detailed diagnosis of slowly developing faults as described in ISO 13373-2.
Trending of parameters should be performed regularly to detect changes in the machine vibration over longer periods of time. For such trend analyses, continuous long-term monitoring by a permanent monitoring system is preferred. A permanent monitoring system also helps to give protection to the machine against failures (e.g. bearing breakdowns). Periodic measurements with additional transducers give valuable information for the condition evaluation and useful information to enable planning of maintenance work. Condition-based monitoring can be considered and applied as described in ISO 17359. This can lead to additional effort, including - — installation of additional transducers, - — monitoring of machine operating parameters influencing the vibration behaviour, - — more detailed analysis, and - — continuous on-line measurement with appropriate data storage and acquisition system. More information relevant to measuring hydropower unit vibration is given in the documents listed in the Bibliography.
ISO/FDIS 13373-7:2026(en)
5.2 Instrumentation
Two principal kinds of vibration measurement are common, which provide complementary information:
a) — Shaftshaft relative vibration, measured with non-contacting proximity probes that are mounted at or near the bearings (e.g. inductive, capacitive and eddy current probes); and b) — Bearingbearing housing vibration, measured with seismic transducers (e.g. accelerometers or velocity transducers) that are mounted on non-rotating parts of the bearing housing. In addition to vibration measurements, transducers can also be installed to measure dynamic pressure, air gap and, by means of strain gauges, stress. These parameters can be used to correlate the cause and effect of an event.
Large hydropower installations normally include proximity probes at each bearing. However, if this is not the case, it is advisable to install two temporary proximity probes at each bearing position with their orientation in the radial plane orthogonal to each other, see Figure 1Figure 1.. 13373-7_ed2fig1.EPS
Figure 1 — Example of measurement locations and directions on a vertical hydropower unit When using temporarily installed proximity probes, the following shall be noted:
- — Relative vibration transducers can be susceptible to electrical and mechanical runout which can differ based upon probe axial location related to the shaft. Axial locations shall be chosen to allow repeatable installations for monitoring and to reduce the effects of this measurement error.
- — The residual total electrical and mechanical runout shall be documented and used to correct rotational speed vibration components when an appropriate phase reference signal is available.
- — Temporary radial vibration transducer locations shall be consistent between measurement events.
ISO/FDIS 13373-7:2026(en) - — For full information about bearing housing vibration, an installation shall contain two radial seismic transducers in orthogonal directions on each bearing housing and one seismic transducer in axial direction for thrust bearings or a bearing braced against a vibrating structure like the turbine head cover. The commonly used signal output is vibration velocity, measured directly with velocity transducers or measured with accelerometers and signal integration.
- — Some acceleration and velocity measuring systems are only able to measure vibration at frequencies down to 10 Hz, which is not suitable in hydropower units where the rotational speed is normally below 600 r/min. The recommended minimum frequency is 0,1 times the rotational frequency for reaction turbines and pumps and 0,4 times the rotational frequency for impulse turbines.
- — All signals shall be measured simultaneously with measurement duration sufficient to characterize such low frequencies.
- — Adding a phase mark transducer for a trigger provides a method to synchronize the measurements and to give phase reference at each measurement point.
International Standards are available to help assessing the vibration severity for the described types of measurement, in particular ISO 20816-1 and ISO 20816-5.
Description of transducer and measurement systems as well as the specification of techniques are given in ISO 13373-1 and ISO 13373-2, which shall be considered when selecting an appropriate transducer and measurement system.
5.3 Measurement of machine operational parameters
Hydropower machine operational parameters [e.g. rotational speed, load, head, tail water level, opening of main regulation device (e.g. wicket gate opening) and bearing oil temperature] can influence the machine vibration characteristics. For a reliable diagnosis, it is important to measure and to store these data simultaneously so as to be able to correlate vibration and the operational state. A hydraulic operational point shall be defined by at least two operational parameters (e.g. head and discharge) and operational mode (e.g. generating, pumping, transient). For variable speed machines, knowledge of the actual rotational speed is required.
The direction of rotation is also an important parameter, as it is required to interpret the phase of synchronous vibration correctly.
6 Initial analysis
The first step shall be to collect the design configuration of the machine and the history of previous anomalies. This initial analysis can be performed using the guidelines given in ISO 13373-3:2015, Annex A, which indicates that it shall identify safety concerns, the presence of high vibration and its vibration severity, the history, effects of operating parameters and the consequences of failing to take corrective actions. All this is used as a basis to judge the risk in operating the machine.
When changes in dynamic behaviour are detected, investigations and tests shall be performed to find the reason for the changes.
7 Specific analysis of hydropower units
Hydropower units are often individual prototypes, which makes it difficult to compare one machine to another. The assessment of the vibration state therefore shall consider actual boundary conditions and its design configuration. Long-term trend recording is of significant help.
ISO/FDIS 13373-7:2026(en) The vibration magnitude is a reaction to the exciting forces. On the hydraulic side (e.g. flow condition in the runner or pressure pulsation on stationary parts) there is a strong dependency on the hydraulic operation point, which shall be defined by two operation parameters [e.g. head and discharge or gate opening (see 5.35.3)].)].
...