ISO/TR 12767:2023
(Main)Measurement of fluid flow by means of pressure differential devices - Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167
Measurement of fluid flow by means of pressure differential devices - Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167
This document provides guidance on estimating the flowrate when using pressure differential devices constructed or operated outside the scope of ISO 5167 series. Additional tolerances or corrections cannot necessarily compensate for the effects of deviating from ISO 5167 series. The information is given, in the first place, to indicate the degree of care necessary in the manufacture, installation and maintenance of pressure differential devices by describing some of the effects of non-conformity to the requirements; and in the second place, to permit those users who cannot comply fully with the requirements to assess, however roughly, the magnitude and direction of the resulting error in flowrate. Each variation dealt with is treated as though it were the only one present. Where more than one is known to exist, there might be unpredictable interactions and care has to be taken when combining the assessment of these errors. If there is a significant number of errors, means of eliminating some of them have to be considered. The variations included in this document are by no means complete and relate largely to examples with orifice plates. An example with Venturi tubes has been placed at the end of its section. This document does not apply to cone meters or wedge meters. There are, no doubt, many similar examples of installations not conforming to ISO 5167 series for which no comparable data have been published. Such additional information from users, manufacturers and any others can be taken into account in future revisions of this document.
Mesurage du débit des fluides au moyen d'appareils déprimogènes — Lignes directrices relatives aux effets des écarts par rapport aux spécifications et aux conditions d’utilisation données dans l’ISO 5167
Le présent document fournit un guide pour estimer le débit avec des appareils déprimogènes construits ou utilisés hors du domaine d’application de la série ISO 5167. Des tolérances ou des corrections supplémentaires ne permettent pas nécessairement de compenser les effets d’un écart par rapport à la série ISO 5167. Ces informations sont fournies, en premier lieu, pour indiquer le niveau de soin nécessaire lors de la fabrication, de l’installation et de la maintenance des appareils déprimogènes, en décrivant certains des effets que peut avoir le non-respect des exigences et, en second lieu, pour permettre aux utilisateurs qui ne peuvent pas se conformer entièrement aux exigences d’évaluer, bien qu’approximativement, l’amplitude et le sens de l’erreur résultante sur le débit. Chaque variation concernée est traitée comme s’il s’agissait de la seule erreur présente. Lorsque l’on sait qu’il y a plusieurs erreurs, des interactions imprévisibles peuvent éventuellement se produire et l’évaluation combinée de ces erreurs nécessite de prendre des précautions particulières. S’il y a un nombre significatif d’erreurs, il faut envisager un moyen d’en éliminer certaines. Les variations incluses dans le présent document ne sont en aucun cas complètes et se réfèrent largement à des exemples portant sur les diaphragmes. Un exemple avec des tubes de Venturi a été introduit à la fin de cette section. Le présent document ne s’applique pas aux cônes de mesure ni aux débitmètres à coin. Il existe, sans aucun doute, de nombreux exemples similaires d’installations non conformes à la série ISO 5167 pour lesquelles aucune donnée comparable n’a été publiée. Ces informations additionnelles provenant des utilisateurs, des fabricants et autres pourront être prises en compte dans de futures révisions du présent document.
General Information
Relations
Overview - ISO/TR 12767:2023 (Measurement of fluid flow by pressure differential devices)
ISO/TR 12767:2023 is a Technical Report that provides practical guidance for estimating flowrate when pressure differential devices (mainly orifice plates and, to a lesser extent, Venturi tubes) are constructed or operated outside the strict requirements of the ISO 5167 series. It explains how departures from the ISO 5167 specifications affect measured flowrate and measurement uncertainty, and gives users a way to assess the likely magnitude and direction of resulting errors. This edition (third, 2023) updates and consolidates existing guidance for manufacture, installation and maintenance of differential-pressure flowmeters.
Key topics and technical requirements
- Scope and intent: Guidance applies where installations cannot fully conform to ISO 5167; it does not apply to cone or wedge meters.
- Main device focus: Predominantly orifice plates; includes an example for Venturi tubes.
- Error assessment approach:
- Treats each variation individually (interactions between multiple deviations can be unpredictable).
- Provides methods to estimate discharge coefficient changes and additional uncertainty.
- Construction deviations covered:
- Orifice-plate edge sharpness and thickness
- Condition of upstream/downstream faces
- Position and condition of pressure tappings
- Carrier ring and joint ring dimensions, protruding welds, eccentricity
- Pipeline and layout effects:
- Upstream/downstream pipe conditions, steps and tapers, pipe diameter, and layout disturbances
- Recommendations on discharge coefficient compensation and limits to applying corrections
- Operational deviations and maintenance:
- Plate deformation (elastic/plastic), deposition on faces and in meter tube, surface roughness changes
- Pipe roughness impacts and mitigation/maintenance strategies
- Uncertainty guidance: How to estimate additional uncertainty when ISO 5167 conditions are not met.
Practical applications - who should use it
- Flow measurement engineers, process and pipeline engineers
- Metering contractors, manufacturers and calibration labs
- Operations and maintenance teams managing retrofit or constrained installations
- Custody transfer and thermal/hydraulic system auditors assessing measurement risk
ISO/TR 12767:2023 is useful where full compliance with ISO 5167 is impossible or costly; it helps stakeholders make informed decisions about acceptable errors, possible corrective actions, and maintenance priorities.
Related standards
- ISO 5167 series (primary normative reference; methods and requirements for differential-pressure flowmeters)
- ISO 5167-1 (general principles and requirements) - referenced directly in this report
Keywords: ISO/TR 12767:2023, ISO 5167, pressure differential devices, orifice plates, Venturi tubes, flowrate measurement, discharge coefficient, meter installation, measurement uncertainty, pipe roughness.
Standards Content (Sample)
TECHNICAL ISO/TR
REPORT 12767
Third edition
2023-09
Measurement of fluid flow by means
of pressure differential devices —
Guidelines on the effect of departure
from the specifications and operating
conditions given in ISO 5167
Mesurage du débit des fluides au moyen d'appareils déprimogènes —
Lignes directrices relatives aux effets des écarts par rapport aux
spécifications et aux conditions d’utilisation données dans l’ISO 5167
Reference number
© ISO 2023
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .v
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 2
5 Effect of errors on flowrate calculations . 3
5.1 General . 3
5.2 Quantifiable effects . 3
6 Effects of deviations in construction . .3
6.1 Orifice-plate edge sharpness . 3
6.2 Thickness of orifice edge . 4
6.3 Condition of upstream and downstream faces of orifice plate . 5
6.4 Position of pressure tappings for an orifice . 6
6.4.1 General . 6
6.4.2 Calculation of discharge coefficient . 6
6.4.3 Estimation of additional uncertainty. 6
6.4.4 Example . 6
6.5 Condition of pressure tappings . . 7
7 Effects of pipeline near the meter . 7
7.1 Pipe diameter . 7
7.2 Steps and taper sections . 7
7.3 Diameter of carrier ring . 8
7.4 Undersize joint rings . 11
7.5 Protruding welds . 11
7.6 Eccentricity . . 11
8 Effects of pipe layout .13
8.1 General .13
8.2 Discharge coefficient compensation . 14
8.2.1 Corrections . 14
8.2.2 Additional uncertainty. 15
8.3 Pressure tappings . 16
8.4 Devices for improving flow conditions . 16
9 Operational deviations .16
9.1 General . 16
9.2 Deformation of an orifice plate . 17
9.2.1 General . 17
9.2.2 Elastic deformation . 17
9.2.3 Plastic deformation . 17
9.3 Deposition on the upstream face of an orifice plate . 18
9.4 Deposition in the meter tube .22
9.5 Orifice-plate edge sharpness .23
9.5.1 Deterioration . 23
9.5.2 Plate reversal .23
9.6 Deposition and increase of surface roughness in Venturi tubes. 24
9.6.1 General . 24
9.6.2 Deposition . 24
9.6.3 Surface roughness . 24
10 Pipe roughness.25
10.1 General . 25
iii
10.2 Upstream pipe . 26
10.3 Downstream pipe . 30
10.4 Reduction of roughness effects .30
10.5 Maintenance . 30
Bibliography .32
iv
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO document should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use
of (a) patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed
patent rights in respect thereof. As of the date of publication of this document, ISO had not received
notice of (a) patent(s) which may be required to implement this document. However, implementers are
cautioned that this may not represent the latest information, which may be obtained from the patent
database available at www.iso.org/patents. ISO shall not be held responsible for identifying any or all
such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 30, Measurement of fluid flow in closed
conduits, Subcommittee SC 2, Pressure differential devices.
This third edition cancels and replaces the second edition (ISO/TR 12767:2007), which has been
technically revised.
The main changes are as follows:
— editorial changes throughout the document.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
v
Introduction
ISO 5167 series specifies methods for flowrate measurement using pressure differential devices.
Adherence to ISO 5167 series results in flowrate measurements whose uncertainty lies within specified
limits. If, however, a flow-metering installation departs, for whatever reason, from the conditions
specified in ISO 5167 series, the specified limits of uncertainty might not be achieved. Many metering
installations exist where these conditions either have not been or cannot be met. In these circumstances,
it is usually not possible to evaluate the precise effect of any such deviations. However, a considerable
amount of data exists which can be used to give a general indication of the effect of non-conformity to
ISO 5167 series and it is presented in this document as a guideline to users of flow-metering equipment.
vi
TECHNICAL REPORT ISO/TR 12767:2023(E)
Measurement of fluid flow by means of pressure
differential devices — Guidelines on the effect of departure
from the specifications and operating conditions given in
ISO 5167
1 Scope
This document provides guidance on estimating the flowrate when using pressure differential devices
constructed or operated outside the scope of ISO 5167 series.
Additional tolerances or corrections cannot necessarily compensate for the effects of deviating from
ISO 5167 series. The information is given, in the first place, to indicate the degree of care necessary in
the manufacture, installation and maintenance of pressure differential devices by describing some of
the effects of non-conformity to the requirements; and in the second place, to permit those users who
cannot comply fully with the requirements to assess, however roughly, the magnitude and direction of
the resulting error in flowrate.
Each variation dealt with is treated as though it were the only one present. Where more than one is
known to exist, there might be unpredictable interactions and care has to be taken when combining
the assessment of these errors. If there is a significant number of errors, means of eliminating some of
them have to be considered. The variations included in this document are by no means complete and
relate largely to examples with orifice plates. An example with Venturi tubes has been placed at the end
of its section. This document does not apply to cone meters or wedge meters. There are, no doubt, many
similar examples of installations not conforming to ISO 5167 series for which no comparable data have
been published. Such additional information from users, manufacturers and any others can be taken
into account in future revisions of this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 5167-1, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-
section conduits running full — Part 1: General principles and requirements
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5167-1 and the following
apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
square edge
angular relationship between the orifice bore of the flow-measurement device and the upstream face,
when the angle between them is 90° ± 0,3°
3.2
sharpness
radius of the edge between the orifice bore of the flow-measurement device and the upstream face
Note 1 to entry: The upstream edge of the orifice bore is considered to be sharp when its radius is not greater
than 0,000 4d, where d is the diameter of the orifice bore.
4 Symbols
For the purposes of this document, the symbols given in Table 1 apply.
Table 1 — Symbols and units
Dimension
M: mass
Symbol Quantity represented SI unit
L: length
T: time
c Percentage change in discharge coefficient [(≡100 ΔC /)C ] dimensionless
C Discharge coefficient dimensionless
C Contraction coefficient dimensionless
c
Diameter of orifice or throat of primary device under working condi-
d L m
tions
D Upstream internal pipe diameter under working conditions L m
D Carrier ring diameter L m
D Orifice-plate support diameter L m
e Orifice thickness L m
E Orifice-plate thickness L m
k Uniform equivalent roughness L m
Distance of upstream pressure tapping from upstream face of plate di-
L dimensionless
vided by pipe bore, D
Distance of downstream pressure tapping from downstream face of plate
L’ dimensionless
divided by pipe bore, D
−1
q Mass flow rate MT kg/s
m
r Orifice-plate edge radius L m
Re Throat Reynolds number dimensionless
d
Re Pipe Reynolds number dimensionless
D
−1
u Local axial velocity LT m/s
−1
u Centreline axial velocity LT m/s
CL
−1
U Mean axial velocity LT m/s
U’ Relative expanded uncertainty dimensionless
−1 −2
Y Modulus of elasticity of orifice-plate material ML T Pa
β Diameter ratio, (= d/D) dimensionless
−1 −2
Δp Differential pressure ML T Pa
−1 −2
Δp Differential pressure required to reach orifice-plate yield stress ML T Pa
y
ε Expansibility (expansion) factor dimensionless
λ Friction factor dimensionless
−3 3
ρ Fluid density ML kg/m
−3 3
ρ Fluid density at the upstream pressure tapping ML kg/m
−1 −2
σ Yield stress of orifice-plate material ML T Pa
y
5 Effect of errors on flowrate calculations
5.1 General
In this document, the effects of deviations from the conditions specified in ISO 5167 series are described
in terms of changes in the discharge coefficient, ΔC, of the meter. The discharge coefficient, C, of a
pressure differential device is given by Formula (1):
41q ()−β
m
C = (1)
επΔ d p()2 ρ
The sharp edge of an orifice plate ensures separation of the flow and consequently contraction of the
fluid stream to the vena contracta. Defining the contraction coefficient, C , as the ratio of the flow area
c
to the geometric area the orifice produces C ≈ 0,6, which mainly accounts for the discharge coefficient,
c
C ≈ 0,6.
The effect of change in the discharge coefficient is illustrated by the following example.
Consider an orifice plate with an unduly rounded edge. The result of this is to reduce the separation
and increase C leading in turn to reduced velocities at the vena contracta. The observed differential
c,
pressure therefore decreases. From Formula (1), it can be seen that the discharge coefficient therefore
increases. Alternatively, as C increases, so does C. If no correction is made for this change in C, the
c
meter reading is less than the actual value.
It can therefore be concluded that
a) an effect which causes an increase in discharge coefficient results in a flowrate reading lower than
the actual value if the coefficient is not corrected,
and conversely,
b) an effect which causes a decrease in discharge coefficient results in a flowrate reading higher than
the actual value if the coefficient is not corrected.
5.2 Quantifiable effects
When the user is aware of such effects and they can be quantified, the appropriate discharge coefficient
can be used and the correct flowrate calculated. However, the precise quantification of these effects is
difficult and so any flowrate calculated in such a manner is considered to have an increased uncertainty.
Except where otherwise stated, an additional uncertainty factor, equivalent to 100 % of the discharge
coefficient correction, is added arithmetically to the relative expanded uncertainty of the discharge
coefficient when estimating the overall uncertainty in the flowrate measurement.
6 Effects of deviations in construction
6.1 Orifice-plate edge sharpness
Orifice plates that do not have the specified sharpness of the inlet edge (edge radius r ≤ 0,000 4d in
accordance with ISO 5167-2:2022, 5.1.7.2), have progressively increasing discharge coefficients as the
edge radius increases. Tests have shown that the effect on the discharge coefficient, C, is to increase it
by 0,5 % for r/d of 0,001, and by about 5 % for r/d of 0,01. This is an approximately linear relationship
(see Figure 1 and Reference [6]). These values apply particularly to Re values above 300 000 and for β
d
values below 0,7, but they can be used as a general guide for other values.
Measurement techniques for edge radius are available, but in general it is better to improve the edge
sharpness to the required value rather than to attempt to measure it and make appropriate corrections.
The effect of nicks in orifice plates has also been measured in Reference [6].
Key
X radius ratio (r/d) (×10 )
Y change in discharge coefficient (%)
1 national engineering laboratory (NEL, UK) tests — D = 300 mm
2 ISO limit — r = 0,000 4d
3 others
4 NEL
5 D = 50 mm (Reference [59])
6 D = 100 mm (Reference [59])
7 D = 150 mm (Reference [37])
8 D = 75 mm (Reference [60])
9 D = 100 mm (Reference [61])
Figure 1 — Effect of edge radius on discharge coefficient
6.2 Thickness of orifice edge
For orifice plates, the increase in discharge coefficient due to excessive thickness of the orifice edge
(see ISO 5167-2:2022, 5.1.5) can be appreciable. With a straight-bore orifice plate in a 150 mm pipe, the
changes in discharge coefficient shown in Figure 2 were obtained (see Reference [7]). Additional data
are shown in Reference [62].
Key
1 section of an orifice plate
2 symbol
3 limit of standard
c change in discharge coefficient (%)
e/D orifice thickness to upstream internal pipe diameter ratio
Figure 2 — Change in discharge coefficient as a function of orifice thickness
6.3 Condition of upstream and downstream faces of orifice plate
The upstream face of an orifice plate is flat and smooth. Excessive roughness leads to an increase in
the discharge coefficient. Tests have indicated that a surface roughness of 0,000 3d causes an increase
in discharge coefficient of the order of 0,1 % (see Reference [34]). Since the requirement for edge
sharpness is r ≤ 0,000 4d, an increase in plate roughness makes it difficult to define the edge sharpness
or to confirm that the sharp edge requirement has been met.
Local damage to the upstream face or edge of an orifice plate does not adversely affect the discharge
coefficient, provided that the damage is kept as far away from the pressure tapping as possible
(see Reference [6]). The discharge coefficient is much less sensitive to the surface condition of the
downstream face of the plate (Reference [6]).
Large-scale lack of flatness, e.g. “dishing”, leads to flow-measurement errors. A “dishing” of 1 % in the
direction of flow causes the reading to be below the actual value, i.e. an increase in C of about 0,2 % for
β = 0,2 and of about 0,1 % for β = 0,7. Distortion against the direction of flow also causes errors which
could be either positive or negative depending on the amount of distortion.
6.4 Position of pressure tappings for an orifice
6.4.1 General
Values of the orifice-plate discharge coefficient for the three standard tapping positions (corner,
flange, D and D/2) can be calculated using ISO 5167-2:2022, Formula (4) (see Reference [58]). Where
the tapping positions fall outside the tolerances permitted in ISO 5167-2 for the three positions, the
discharge coefficient is estimated as described in 6.4.2. An additional uncertainty factor is associated
with the use of non-standard tapping positions.
6.4.2 Calculation of discharge coefficient
Calculate the actual values of L and L’ . The discharge coefficient can be estimated only if L ≤ 1 and
1 2 1
L’ ≤ 0,47.
Using the actual values of L and L’ estimate the discharge coefficient using ISO 5167-2:2022,
1 2
Formula (4).
6.4.3 Estimation of additional uncertainty
If tappings lie between the flange and the corner tappings, the additional uncertainty, δU′, expressed
as a percentage, can be estimated from Formula (2):
C
F
′
δU =−25 1 (2)
C
CT
where
C is the discharge coefficient for flange tappings;
F
C is the discharge coefficient for corner tappings.
CT
′
If tappings lie between the D and D/2 tappings and the flange tappings, the additional uncertainty, δU ,
expressed as a percentage, can be estimated from Formula (3):
C
DD and /2
′
δU =−25 1 (3)
C
F
where C is the discharge coefficient for D and D/2 tappings.
D and D/2
6.4.4 Example
Consider an orifice meter with β = 0,6, Re = 10 , D = 250 mm and tappings at 0,15D upstream and
D
downstream of the plate.
To estimate the discharge coefficient, use ISO 5167-2:2022, Formula (4), with L = L’ = 0,15.
1 2
The tappings in this example lie between the flange tapping and D and D/2 tapping positions. From,
respectively, ISO 5167-2:2022, Tables A.8 and A.2: C = 0,605 1; C = 0,607 0. Therefore
F D and D/2
0,605 1
′
δU =−25 10= ,078
0,607 0
The relative expanded uncertainty in the discharge coefficient at k = 2 (approximately 95 % confidence
level) is 0,5 % (see ISO 5167-2:2022, 5.3.3.1).
Therefore, the overall relative expanded uncertainty at k = 2 (approximately 95 % confidence level) is
0,5 + 0,078 ≈ 0,6 % (i.e. the uncertainties have simply been added together).
6.5 Condition of pressure tappings
Experience has shown that large errors can be created by pressure tappings which have burrs or
deposits on, or close to, the edge where the tapping penetrates the pipe wall. This is particularly the
case where the tappings are in the main flow stream, such as throat tappings in nozzles or Venturi
tubes, where small burrs can give rise to significant percentage errors. Upstream corner tappings and
downstream tappings in relatively dead zones are much less liable to cause this problem.
The installation is inspected before use and at regular intervals to ensure that these anomalies are not
present.
7 Effects of pipeline near the meter
7.1 Pipe diameter
The internal diameter of the pipe upstream and downstream of the primary device is always measured
to ensure that it is in accordance with ISO 5167-2:2022, 6.4, ISO 5167-3:2022, 6.4 or ISO 5167-4:2022,
6.4.1. Errors in the upstream internal diameter measurement cause errors in the calculated flowrate,
which are given by Formula (4):
δq
−2 δD
β
m
= (4)
q D
()1−
β
m
These errors become significant for large β, e.g. with β = 0,75, a positive 1 % error in D causes a negative
1 % error in q .
m
The downstream pipe is far less critical, as for an orifice plate, an ISA 1932 nozzle or a long radius
nozzle its diameter need only be within 3 % of that of the upstream pipe (see ISO 5167-2:2022, 6.4.6 or
ISO 5167-3:2022, 6.4.6) and for a Venturi nozzle or a Venturi tube its diameter need only be ≥90 % of
the diameter at the end of the divergent section (see ISO 5167-3:2022 6.4.6 or ISO 5167-4:2022, 6.4.1.3).
7.2 Steps and taper sections
Sudden enlargements of the pipe in the vicinity of the primary device are always to be avoided as
large errors in flow measurement result from their use. Similarly, tapering sections of pipe can lead to
significant errors, as can be seen from Table 2 which gives the order of errors to be expected when an
orifice plate with corner tappings is immediately preceded or followed by a taper piece.
The information in Table 2 indicates that a taper piece divergent in the direction of flow, and placed
immediately upstream, is not recommended, since discharge-coefficient increases of up to 50 % result.
On the other hand, a convergent taper piece, whether installed before or after the orifice plate, and
provided it is not of a steeper angle than those shown, results in coefficient changes of generally less
than 2 %.
Table 2 — Effect of taper pieces
Order of the discharge coefficient
Position of orifice plate β
change to be expected
%
a) Immediately downstream of a divergent taper piece
0,4 +10
0,7 +50
b) Immediately downstream of a convergent taper piece
0,4 −0,5
0,7 −2
c) Immediately upstream of a convergent taper piece
0,4 0 to −1
0,7 +1
7.3 Diameter of carrier ring
The requirements for the sizing and concentric mounting of carrier rings for orifice plates and nozzles
are specified in ISO 5167-2:2022, 6.4 and 6.5, ISO 5167-3:2022, 6.4 and 6.5 and ISO 5167-2:2022, Figure 4.
If the requirement of ISO 5167-2:2022, 6.5.4 and ISO 5167-3:2022, 6.5.4 (i.e. that the centred carrier ring
does not protrude into the pipe) is not met, relatively large flow-measurement errors are introduced.
Figure 3 shows such an installation and Figure 4, using the same notation, shows the approximate errors
introduced for the given conditions, where a is the width of the portion of the carrier ring upstream of
the upstream face of the orifice plate or nozzle. It is emphasized that in arriving at these errors, the
internal carrier ring diameter, D , and not the diameter of the main line, has been used in determining
the calculated flowrate and is to be used for D in determining the correction factor when making use of
the values shown.
Where the carrier is oversize, experimental results indicate that for β = 0,74 a carrier 11 % oversize and
extending 0,05D upstream from the plate increased the discharge coefficient by approximately 0,5 %.
However, for a similar geometry but with β = 0,63, no effect was found.
a) Orifice plate
b) Nozzle
a
Direction of flow.
Figure 3 — Carrier having internal diameter, D , less than pipe diameter, D
a) Orifice plate
b) Nozzle
Key
X diameter ratio
Y change in discharge coefficient (%)
1 a = 0,2D to 0,3D
Figure 4 — Effect of incorrect carrier diameter
7.4 Undersize joint rings
When the inside diameter of a joint ring or gasket is smaller than the pipe diameter, especially on
the upstream side of an orifice plate or nozzle, very large flow-measurement errors might occur.
The magnitude and sign of the effect in relation to the measurement of flowrate is dependent on the
combination of a number of variables, e.g. the thickness of the joint ring upstream of the orifice plate,
the extent of its protrusion into the flow, its position relative to the orifice plate and pressure tappings,
and the degree of roughness of the upstream pipe.
7.5 Protruding welds
The effect of an undressed circumferential weld protruding into the pipe bore adjacent to the primary
device is similar to that of an undersize joint ring. Such an effect might arise from the fitting of a weld-
neck flange, and the magnitude of the effect depends on the height uniformity, or otherwise, of the
protruding weld, and its position in relation to the single or multiple pressure tapping arrangement
employed to measure the differential pressure across the primary device. To quantify the resulting
error in a specific situation is difficult without a direct calibration.
Seamed pipe is acceptable, provided that the internal weld bead is parallel to the pipe axis throughout
the entire length of the pipe required, to satisfy the installation requirements for the primary device
being used, and any weld bead does not have a height greater than the permitted step in diameter.
Unless an annular slot is used, the seam is not situated within any sector of ±30° centred on any
individual pressure tapping to be used in conjunction with the primary device. If an annular slot is
used, the location of the seam is not significant. If spirally wound pipe is used, then it is machined to a
smooth bore. (See ISO 5167-1:2022, 7.1.4.)
7.6 Eccentricity
The requirements for concentric mounting of the device are given in ISO 5167-2:2022, 6.5.3 and 6.5.4,
ISO 5167-3:2022, 6.5.3 and 6.5.4 and ISO 5167-4:2022, 6.4.1. The geometric measure of eccentricity is
the distance between the pipe and orifice-plate centrelines and is often expressed as a percentage of
the pipe diameter, D. Figure 5 shows the eccentric mounting of an orifice plate in a sideways direction
relative to the upstream pipeline. The displacement is to the right and the eccentricity is a combination
of the dimensional tolerances arising from the bolt-hole pitch-circle diameter, the bolt diameter, the
bolt-hole diameter and the outer diameter of the orifice plate.
Experimental evidence on the effects of eccentricity is limited, but it has been shown that for orifice
plates, the effect on discharge coefficient is a function of β, pipe size and roughness, pressure-tapping
type, location and magnitude, as well as the position of the orifice centre relative to the pressure
tapping.
Experimental work indicates that the errors due to eccentricity increase in general with β. For β = 0,2
and eccentricity up to 5 % of D, discharge coefficient increases are unlikely to exceed 0,1 %. For larger β,
the changes are best shown graphically as in Figure 6.
Below 3 % eccentricity, the error varies with type of tappings and direction of eccentricity. The meter
is least sensitive to eccentricity perpendicular to the tappings. Above 3 % eccentricity, errors for all
tappings and directions increase rapidly.
NOTE No data are available for corner tappings, but the errors are probably similar to those for flange
tappings since the above data were obtained from a test line with D = 150 mm.
A further effect of eccentric positioning of an orifice plate is an increased unsteadiness of the differential
pressure signal obtained. Observations have shown, for example, a marked increase in differential
pressure reading fluctuations with increasing eccentricity for all values of β between 0,4 and 0,7.
Because of the number of variants contributing to the effect of eccentricity on the measurement of
flow, the effect is difficult to quantify. It is very important to restrict eccentricity to less than 3 % of D,
particularly in the direction of the tappings.
The effect of eccentricity is minimized by employing four equally-spaced upstream and downstream
tappings on the flowmeter, as illustrated in ISO 5167-1:2022, Figure 1. The pressure lines from these are
then coupled in the widely used triple-T tapping arrangement in order to obtain an average differential
pressure reading.
As a general guide, a reasonable assumption is that the effects of eccentric mounting for multi-tapped
nozzles will be less than those for orifice plates of equivalent β. Venturi tubes are less likely to be
installed off-centre.
NOTE Combined installation faults: it is recommended that errors arising from the combined effects
of eccentricity, carrier ring steps, etc., are not taken into account additively. The total possible error will be
governed by the strongest of the effects present.
Key
1 bolt-hole pitch circle
2 flange centreline
3 orifice bore
4 orifice-plate outside diameter
5 flange bore
6 pipe inside diameter
7 pipe centreline
8 orifice centreline
9 eccentricity
Figure 5 — Possible orifice-plate eccentricity resulting from specified tolerances on bolt hole,
bolt hole pitch circle, pipe outside diameter and flange bore
a) β = 0,75 b) β = 0,66
c) β = 0,57
Key
X eccentricity (%)
Y change in discharge coefficient (%)
D and D/2 tappings
flange tappings
a
±0,3 %.
b
(away from tapping 1) ← → (towards tapping 1).
c
±0,5 %.
d
±0,7 %.
Figure 6 — Discharge coefficient error vs. eccentricity for an orifice plate with D and D/2
and flange tappings
8 Effects of pipe layout
8.1 General
Minimum values of the straight lengths required between the primary device and various upstream
fittings are given in ISO 5167-2:2022, 6.2, ISO 5167-3:2022, 6.2 and ISO 5167-4:2022, 6.2. Minimum
straight lengths are given both for “zero additional uncertainty” and for “0,5 % additional uncertainty”
in the discharge coefficient.
When the minimum requirements for even “0,5 % additional uncertainty” cannot be satisfied, it
is appropriate for the user both to make a correction to compensate for the change in the discharge
coefficient and to increase the value of the percentage uncertainty.
Corrections and additional uncertainties for square-edged orifice plates with corner, flange and D and
D/2 tappings are given in Tables 3 and 4 for a variety of upstream pipe bends and fittings. Shifts in
columns 4 and 5 are particularly variable, depending on the exact details of the double bend.
Additional data on shifts in orifice-plate discharge coefficients for a large number of upstream fittings
are given in References [8] to [11].
8.2 Discharge coefficient compensation
8.2.1 Corrections
The discharge coefficient can be corrected using the data in Table 3 as illustrated in the following
examples:
a) percentage change in coefficient is +1,1 %, therefore the coefficient is multiplied by 1,011;
b) percentage change in coefficient is −2,3 %, therefore the coefficient is multiplied by 0,977.
Table 3 — Percentage change in discharge coefficient, c, when the straight pipe lengths before
the orifice are less than those specified in ISO 5167-2
Upstream
straight β Type of fitting (for details of nomenclature, see key)
length
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
4D 0,5 −1,4 −1,4 −0,5 +2,9 +2,9 −0,4 +8,2 — +0,2 +0,2 −1,0 −0,8 +0,3 +0,5 +0,2 — —
0,6 −2,3 −2,2 −1,1 +1,7 +1,3 −1,2 +8,5 — −0,2 −0,3 −2,4 −1,7 +0,3 0 −0,2 — —
0,7 −3,8 −3,2 −1,8 +0,1 +0,4 −2,1 +8,2 — −0,9 −0,7 −4,4 −2,3 +0,3 −0,6 0 — —
b b b b b
0,8 −5,6 — −2,6 −2,4 — −3,1 +3,4 — −2,2 — −7,5 — +0,3 −1,3 — — —
a
8D 0,5 −0,7 −0,7 −0,3 +2,4 +2,4 0 +6,3 +6,4 −0,2 −0,2 −0,6 −0,4 — −0,2 −0,2 −0,8 −0,7
a
0,6 −1,4 −1,2 −0,7 +1,4 +1,2 −0,7 +5,6 +6,1 −0,6 −0,4 −1,3 −1,2 — −0,7 −0,8 −1,3 −1,2
0,7 −2,2 −1,9 −1,2 +0,3 +0,4 −1,3 +4,4 +6,1 −1,1 −0,8 −2,1 −1,9 +0,1 −1,2 −1,2 −1,7 −1,7
b b b b b b
0,8 −3,2 — −1,8 −1,7 — −2,0 +2,3 — −1,9 — −3,1 — +0,1 −1,8 — −2,0 −2,1
a a a a c
12D 0,5 — — — +2,0 +2,0 0 +5,5 +5,5 −0,2 −0,1 −0,4 −0,3 — −0,3 −0,2 — —
a c
0,6 −0,8 −0,8 −0,4 +1,2 +1,0 −0,4 +3,9 +4,3 −0,4 −0,3 −0,9 −0,9 — −0,7 −0,6 −0,8 −0,8
a
0,7 −1,4 −1,4 −0,8 +0,3 +0,3 −0,8 +2,6 +3,2 −0,8 −0,7 −1,3 −1,3 — −1,1 −1,0 −1,2 −1,1
b b b b b b
0,8 −2,0 — −1,3 −1,3 — −1,3 +1,5 — −1,3 — −1,7 — — −1,5 — −1,5 −1,4
a a a a
16D 0,5 — — — +1,7 +1,7 0 +5,1 +5,0 −0,1 0 −0,2 −0,2 — −0,2 −0,2 — —
a a a
0,6 — — −0,3 +1,1 +0,9 −0,3 +3,5 +3,6 −0,3 −0,2 −0,6 −0,6 — −0,4 −0,4 — —
a
0,7 −0,8 −0,8 −0,5 +0,3 +0,3 −0,5 +2,1 +2,4 −0,5 −0,5 −0,9 −1,0 — −0,7 −0,6 −0,9 —
b b b b b b
0,8 −1,3 — −0,7 −1,1 — −0,8 +0,8 — −0,8 — −1,0 — — −1,0 — −1,2 —
a
Refer to ISO 5167-2:2022, Table 3.
b
For D and D/2 tappings, discharge coefficient changes measured for β > 0,75 are not used for interpolation to give discharge
′
coefficient changes for β ≤ 0,75, as the downstream tapping is in the pressure recovery region if L > 2(1 − β).
c
For a concentric expander 0,5D to D over a length of D to 2D refer to ISO 5167-2:2022, Table 3.
Key
No. Type of upstream fitting Type of No. Type of upstream fitting Type of
tappings tappings
1 Single short radius 90° bend C o r ne r , 10 Butterfly valve, fully open D and D/2
flange
2 Single short radius 90° bend D and D/2 11 Butterfly valve, 52° open C or ne r ,
flange
3 Two 90° bends in the same plane, U- All 12 Butterfly valve, 52° open D and D/2
or S-configuration, 0D to 10D spacer
4 Two 90° bends at right angles, no C o r ne r , 13 Gate valve, fully open All
spacer flange
5 Two 90° bends at right angles, no D and D/2 14 Gate valve, ⅔ open C or ne r ,
spacer flange
6 Two 90° bends at right angles, 5D to All 15 Gate valve, ⅔ open D and D/2
11D spacer
7 Two 90° mitre bends at right angles, C o r ne r , 16 Gate valve, ¼ open and globe valve All
no spacer flange
8 Two 90° mitre bends at right angles, D and D/2 17 Symmetrical enlargement, tapered All
no spacer or abrupt
9 Butterfly valve, fully open C o r ne r ,
flange
Table 4 — Formulae for additional uncertainty in the orifice discharge coefficient, to be used
with the percentage changes given in Table 3, for all tapping arrangements
Type of upstream fitting Formulae for additional percentage relative ex-
panded uncertainty
a
Piezometer ring Single tapping
e.g. Triple-T
Single short radius 90° bend. Bend radii 1D to 1,5D 0,5(1 + 0,6∣c∣) 0,5 + 0,6∣c∣
Two 90° bends, U- or S-configuration, in same plane 0,5(1 + ∣c∣) 0,5 + ∣c∣
Two 90° bends at right a
...
RAPPORT ISO/TR
TECHNIQUE 12767
Troisième édition
2023-09
Mesurage du débit des fluides au
moyen d'appareils déprimogènes —
Lignes directrices relatives aux
effets des écarts par rapport aux
spécifications et aux conditions
d’utilisation données dans l’ISO 5167
Measurement of fluid flow by means of pressure differential devices —
Guidelines on the effect of departure from the specifications and
operating conditions given in ISO 5167
Numéro de référence
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2023
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii
Sommaire Page
Avant-propos .v
Introduction . vi
1 Domaine d’application . 1
2 Références normatives .1
3 Termes et définitions . 1
4 Symboles . 2
5 Effet des erreurs sur les calculs de débit . 3
5.1 Généralités . 3
5.2 Effets quantifiables. 3
6 Effets des écarts lors de la construction . 4
6.1 Acuité de l’arête du diaphragme . 4
6.2 Épaisseur de l’arête de l’orifice . 5
6.3 État des faces amont et aval du diaphragme . 5
6.4 Position des prises de pression pour un orifice . 6
6.4.1 Généralités . 6
6.4.2 Calcul du coefficient de décharge . 6
6.4.3 Estimation de l’incertitude supplémentaire . 6
6.4.4 Exemple . 7
6.5 État des prises de pression . 7
7 Effets du positionnement de la canalisation près de l’organe déprimogène .7
7.1 Diamètre de la conduite . 7
7.2 Variations du diamètre interne de la conduite . 7
7.3 Diamètre de la bague porteuse . 8
7.4 Joints circulaires sous-dimensionnés . 11
7.5 Soudures saillantes . 11
7.6 Excentricité . . 11
8 Effets de la disposition de la conduite.15
8.1 Généralités . 15
8.2 Modifications du calcul du coefficient de décharge . 15
8.2.1 Corrections . 15
8.2.2 Incertitude supplémentaire . 17
8.3 Prises de pression . 17
8.4 Appareils pour améliorer les conditions d’écoulement . 17
9 Écarts opérationnels .17
9.1 Généralités . 17
9.2 Déformation d’un diaphragme . 18
9.2.1 Généralités . 18
9.2.2 Déformation élastique . 18
9.2.3 Déformation plastique. 19
9.3 Dépôt sur la face amont d’un diaphragme . 20
9.4 Dépôt dans la conduite support à la mesure . 24
9.5 Acuité de l’arête du diaphragme . 26
9.5.1 Détérioration . 26
9.5.2 Retournement du diaphragme . 26
9.6 Dépôt et augmentation de la rugosité de surface dans des tubes de Venturi . 27
9.6.1 Généralités . 27
9.6.2 Dépôt . 27
9.6.3 Rugosité de surface . 27
10 Rugosité de la conduite .28
10.1 Généralités .28
iii
10.2 Conduite amont .29
10.3 Conduite aval . . 33
10.4 Réduction des effets de la rugosité. 33
10.5 Maintenance . 33
Bibliographie .35
iv
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir
www.iso.org/directives).
L’ISO attire l’attention sur le fait que la mise en application du présent document peut entraîner
l’utilisation d’un ou de plusieurs brevets. L’ISO ne prend pas position quant à la preuve, à la validité et
à l’applicabilité de tout droit de propriété revendiqué à cet égard. À la date de publication du présent
document, l’ISO n’avait pas reçu notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa
mise en application. Toutefois, il y a lieu d’avertir les responsables de la mise en application du présent
document que des informations plus récentes sont susceptibles de figurer dans la base de données de
brevets, disponible à l’adresse www.iso.org/brevets. L’ISO ne saurait être tenue pour responsable de ne
pas avoir identifié tout ou partie de tels droits de brevet.
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de
l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles techniques
au commerce (OTC), voir https://www.iso.org/fr/foreword-supplementary-information.html.
Le présent document a été élaboré par le comité technique ISO/TC 30, Mesure de débit des fluides dans
les conduites fermées, sous-comité SC 2, Appareils déprimogènes.
Cette troisième édition annule et remplace la deuxième édition (ISO/TR 12767:2007), qui a fait l’objet
d’une révision technique.
Les principales modifications sont les suivantes:
— modifications éditoriales dans tout le document.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html.
v
Introduction
La série ISO 5167 spécifie des méthodes de mesurage du débit à l’aide d’appareils déprimogènes. La
conformité à la série ISO 5167 conduit à des mesurages de débit dont l’incertitude se situe dans les limites
spécifiées. Toutefois, si une installation de mesure de débit s’écartait, pour une raison ou une autre, des
conditions spécifiées dans la série ISO 5167, les limites spécifiées pour l’incertitude pourraient ne pas
être atteintes. Il existe de nombreuses installations de mesure pour lesquelles ces conditions n’ont pas
été ou ne peuvent pas être respectées. Dans ces circonstances, il est généralement impossible d’évaluer
l’effet précis de tels écarts. Il existe toutefois une quantité considérable de données qui peuvent être
utilisées pour donner une indication générale de l’effet d’une non-conformité à la série ISO 5167; ces
données sont regroupées dans le présent document sous forme de lignes directrices à l’intention des
utilisateurs d’équipements de débitmétrie.
vi
RAPPORT TECHNIQUE ISO/TR 12767:2023(F)
Mesurage du débit des fluides au moyen d'appareils
déprimogènes — Lignes directrices relatives aux effets
des écarts par rapport aux spécifications et aux conditions
d’utilisation données dans l’ISO 5167
1 Domaine d’application
Le présent document fournit un guide pour estimer le débit avec des appareils déprimogènes construits
ou utilisés hors du domaine d’application de la série ISO 5167.
Des tolérances ou des corrections supplémentaires ne permettent pas nécessairement de compenser les
effets d’un écart par rapport à la série ISO 5167. Ces informations sont fournies, en premier lieu, pour
indiquer le niveau de soin nécessaire lors de la fabrication, de l’installation et de la maintenance des
appareils déprimogènes, en décrivant certains des effets que peut avoir le non-respect des exigences
et, en second lieu, pour permettre aux utilisateurs qui ne peuvent pas se conformer entièrement aux
exigences d’évaluer, bien qu’approximativement, l’amplitude et le sens de l’erreur résultante sur le débit.
Chaque variation concernée est traitée comme s’il s’agissait de la seule erreur présente. Lorsque l’on
sait qu’il y a plusieurs erreurs, des interactions imprévisibles peuvent éventuellement se produire et
l’évaluation combinée de ces erreurs nécessite de prendre des précautions particulières. S’il y a un
nombre significatif d’erreurs, il faut envisager un moyen d’en éliminer certaines. Les variations incluses
dans le présent document ne sont en aucun cas complètes et se réfèrent largement à des exemples
portant sur les diaphragmes. Un exemple avec des tubes de Venturi a été introduit à la fin de cette
section. Le présent document ne s’applique pas aux cônes de mesure ni aux débitmètres à coin. Il
existe, sans aucun doute, de nombreux exemples similaires d’installations non conformes à la série
ISO 5167 pour lesquelles aucune donnée comparable n’a été publiée. Ces informations additionnelles
provenant des utilisateurs, des fabricants et autres pourront être prises en compte dans de futures
révisions du présent document.
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 5167-1, Mesurage de débit des fluides au moyen d'appareils déprimogènes insérés dans des conduites en
charge de section circulaire — Partie 1: Principes généraux et exigences générales
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 5167-1 ainsi que les
suivants, s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
— IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
3.1
arête rectangulaire
relation angulaire entre l’orifice de l’appareil de mesure de débit et la face amont, lorsque l’angle entre
eux est de 90° ± 0,3°
3.2
acuité
rayon de l’arête entre l’orifice de l’appareil de mesure de débit et la face amont
Note 1 à l'article: L’arête amont de l’orifice est considérée comme aiguë lorsque le rayon n’est pas supérieur à
0,000 4d, où d est le diamètre de l’orifice.
4 Symboles
Pour les besoins du présent document, les symboles donnés dans le Tableau 1 s’appliquent.
Tableau 1 — Symboles et unités
Dimension
M: masse
Symbole Grandeur représentée Unité Sl
L: longueur
T: temps
c Variation en pourcentage du coefficient de décharge [(≡100 ΔC /)C ] sans dimension
C Coefficient de décharge sans dimension
C Coefficient de contraction sans dimension
c
Diamètre de l’orifice ou du col de l’élément primaire dans les condi-
d L m
tions de service
Diamètre intérieur de la conduite en amont dans les conditions des
D L m
service
D Diamètre de la bague porteuse L m
D Diamètre du support du diaphragme L m
e Épaisseur de l’orifice L m
E Épaisseur du diaphragme L m
k Rugosité uniforme équivalente L m
Distance entre la prise de pression amont et la face amont du
L sans dimension
diaphragme, divisée par le diamètre de la conduite, D
Distance entre la prise de pression aval et la face aval du diaphragme,
L’ sans dimension
divisée par le diamètre de la conduite, D
−1
q Débit-masse MT kg/s
m
r Rayon de l’arête du diaphragme L m
Re Nombre de Reynolds au col sans dimension
d
Re Nombre de Reynolds rapporté à la conduite sans dimension
D
−1
u Vitesse axiale locale LT m/s
−1
u Vitesse axiale au centre de la conduite LT m/s
CL
−1
U Vitesse axiale moyenne LT m/s
U’ Incertitude relative élargie sans dimension
−1 −2
Y Module d’élasticité du matériau du diaphragme ML T Pa
β Rapport des diamètres (= d/D) sans dimension
−1 −2
Δp Pression différentielle ML T Pa
Pression différentielle requise pour atteindre la limite d’élasticité du
−1 −2
Δp ML T Pa
y
diaphragme
ε Coefficient de détente sans dimension
TTaabblleeaau 1 u 1 ((ssuuiitte)e)
Dimension
M: masse
Symbole Grandeur représentée Unité Sl
L: longueur
T: temps
λ Facteur de frottement sans dimension
−3 3
ρ Masse volumique du fluide ML kg/m
−3 3
ρ Masse volumique du fluide au niveau de la prise de pression amont ML kg/m
−1 −2
σ Limite d’élasticité du matériau du diaphragme ML T Pa
y
5 Effet des erreurs sur les calculs de débit
5.1 Généralités
Dans le présent document, les effets des écarts par rapport aux conditions spécifiées dans la série
ISO 5167 sont décrits en termes de variation du coefficient de décharge, ΔC, de l’appareil. Le coefficient
de décharge, C, d’un appareil déprimogène est donné par la Formule (1):
41 ()−
q β
m
C = (1)
επΔ d p()2
ρ
L’arête vive d’un diaphragme assure la séparation de l’écoulement et donc la contraction du flux de
fluide jusqu’à la «vena contracta». En définissant le coefficient de contraction, C , comme le rapport
c
entre la section de passage et la section géométrique produite par l’orifice, on obtient C ≈ 0,6, ce qui
c
explique principalement le coefficient de décharge, C ≈ 0,6.
L’effet de la variation du coefficient de décharge est illustré par l’exemple suivant.
Soit un diaphragme avec une arête exagérément arrondie. Cela a pour conséquence de réduire la
séparation et d’augmenter C , ce qui conduit alors à des vitesses réduites au niveau de la «vena contracta».
c
La pression différentielle observée diminue donc. À partir de la Formule (1), on peut observer que le
coefficient de décharge augmente donc. D’un autre côté, C augmente lorsque C augmente. Si aucune
c
correction n’est effectuée pour cette variation de C, l’appareil affiche une valeur inférieure à la valeur
réelle.
On peut donc en conclure que:
a) un effet qui entraîne une augmentation du coefficient de décharge conduit à une mesure de débit
inférieure à la valeur réelle si le coefficient n’est pas corrigé;
et à l’inverse,
b) un effet qui entraîne une diminution du coefficient de décharge conduit à une mesure de débit
supérieure à la valeur réelle si le coefficient n’est pas corrigé.
5.2 Effets quantifiables
Lorsque l’utilisateur est au courant de ces effets et qu’ils peuvent être quantifiés, le coefficient de
décharge approprié peut être utilisé et le débit correct calculé. Cependant, la quantification précise
de ces effets est difficile et on considère donc que tout débit calculé de cette manière comporte une
incertitude plus élevée.
Sauf indication contraire, un facteur d’incertitude supplémentaire, équivalent à 100 % de la correction
du coefficient de décharge, est ajouté arithmétiquement à l’incertitude relative élargie du coefficient de
décharge lors de l’estimation de l’incertitude globale du mesurage du débit.
6 Effets des écarts lors de la construction
6.1 Acuité de l’arête du diaphragme
Les diaphragmes dont l’arête d’entrée n’a pas l’acuité spécifiée (rayon de l’arête r ≤ 0,000 4d selon
l’ISO 5167-2:2022, 5.1.7.2) ont des coefficients de décharge qui augmentent progressivement lorsque
le rayon de l’arête augmente. Des essais ont montré que l’effet sur le coefficient de décharge, C, est une
augmentation de 0,5 % pour un r/d de 0,001 et d’environ 5 % pour un r/d de 0,01. Cette relation est
approximativement linéaire (voir la Figure 1 et la Référence [6]). Ces valeurs s’appliquent en particulier
aux valeurs de Re supérieures à 300 000 et aux valeurs de β inférieures à 0,7, mais elles peuvent servir
d
de guide général pour d’autres valeurs.
Il existe des techniques de mesure du rayon de l’arête, mais il vaut mieux en général améliorer l’acuité
de l’arête pour atteindre la valeur requise plutôt que de tenter de la mesurer et faire les corrections
appropriées.
L’effet des entailles dans les diaphragmes a également été mesuré dans la Référence [6].
Légende
X rapport des rayons (r/d) ( × 10 )
Y variation du coefficient de décharge (%)
1 essais du National Engineering Laboratory (NEL, RU) — D = 300 mm
2 limite ISO — r = 0,000 4d
3 autres
4 NEL
5 D = 50 mm (Référence [59])
6 D = 100 mm (Référence [59])
7 D = 150 mm (Référence [37])
8 D = 75 mm (Référence [60])
9 D = 100 mm (Référence [61])
Figure 1 — Effet du rayon de l’arête sur le coefficient de décharge
6.2 Épaisseur de l’arête de l’orifice
Pour les diaphragmes, l’augmentation du coefficient de décharge due à une épaisseur excessive de
l’arête de l’orifice (voir l’ISO 5167-2:2022, 5.1.5) peut être appréciable. Les variations du coefficient de
décharge illustrées à la Figure 2 ont été obtenues avec une plaque à orifice droit sur une conduite de
150 mm (voir la Référence [7]). La Référence [62] fournit des données supplémentaires.
Légende
1 section d’un diaphragme
2 symbole
3 limite de la norme
c variation du coefficient de décharge (%)
e/D rapport de l’épaisseur de l’orifice sur le diamètre intérieur de la conduite en amont
Figure 2 — Variation du coefficient de décharge en fonction de l’épaisseur de l’orifice
6.3 État des faces amont et aval du diaphragme
La face amont d’un diaphragme est plane et lisse. Une rugosité excessive conduit à une augmentation
du coefficient de décharge. Les essais ont indiqué qu’une rugosité de surface de 0,000 3d engendre
une augmentation du coefficient de décharge de l’ordre de 0,1 % (voir la Référence [34]). Étant donné
que l’exigence d’acuité de l’arête est r ≤ 0,000 4d, une augmentation de la rugosité du diaphragme rend
difficile la détermination de l’acuité de l’arête ou la confirmation que l’exigence relative à l’arête vive a
été satisfaite.
Un endommagement local de la face amont ou de l’arête d’un diaphragme n’a pas d’effet néfaste sur
le coefficient de décharge, à condition que le dommage soit maintenu aussi éloigné que possible de la
prise de pression (voir la Référence [6]). Le coefficient de décharge est beaucoup plus sensible à l’état de
surface de la face aval du diaphragme (Référence [6]).
Un défaut de planéité à grande échelle, par exemple une incurvation, conduit à des erreurs de mesurage
du débit. Une incurvation de 1 % dans le sens de l’écoulement entraîne une mesure inférieure à la
valeur réelle, c’est-à-dire une augmentation de C d’environ 0,2 % pour β = 0,2 et d’environ 0,1 % pour
β = 0,7. Une distorsion dans le sens opposé à l’écoulement est également à l’origine d’erreurs pouvant
être positives ou négatives selon la quantité de distorsion.
6.4 Position des prises de pression pour un orifice
6.4.1 Généralités
Les valeurs du coefficient de décharge d’un diaphragme pour les trois positions normalisées des prises
de pression (dans les angles, à la bride, à D et D/2) peuvent être calculées à l’aide de la Formule (4) de
l’ISO 5167-2:2022 (voir la Référence [58]). Lorsque les positions des prises de pression sont hors des
tolérances autorisées dans l’ISO 5167-2 pour les trois positions, le coefficient de décharge est estimé
comme décrit en 6.4.2. Un facteur d’incertitude supplémentaire est associé à l’utilisation de positions de
prises de pression non normalisées.
6.4.2 Calcul du coefficient de décharge
Calculer les valeurs réelles de L et L’ . Le coefficient de décharge peut être estimé uniquement si L ≤ 1
1 2 1
et L’ ≤ 0,47.
En utilisant les valeurs réelles de L et de L’ , estimer le coefficient de décharge à l’aide de la Formule (4)
1 2
de l’ISO 5167-2:2022.
6.4.3 Estimation de l’incertitude supplémentaire
Si les prises de pression se trouvent entre les prises à la bride et dans les angles, l’incertitude
′
supplémentaire, δU , exprimée en pourcentage, peut être estimée par la Formule (2):
C
F
′
δU =−25 1 (2)
C
CT
où
C est le coefficient de décharge pour les prises à la bride;
F
C est le coefficient de décharge pour les prises dans les angles.
CT
Si les prises de pression se trouvent entre les prises à D et D/2 et les prises à la bride, l’incertitude
′
supplémentaire, δU , exprimée en pourcentage, peut être estimée par la Formule (3):
C
DD et /2
δU′=−25 1 (3)
C
F
où C est le coefficient de décharge pour les prises à D et D/2.
D et D/2
6.4.4 Exemple
Soit un débitmètre à diaphragme avec β = 0,6, Re = 10 , D = 250 mm et des prises à 0,15D en amont et
D
en aval du diaphragme.
Pour estimer le coefficient de décharge, utiliser la Formule (4) de l’ISO 5167-2:2022, avec L = L’ = 0,15.
1 2
Les prises de pression dans cet exemple se trouvent entre les positions des prises à la bride et à D et D/2.
À partir des Tableaux A.8 et A.2, respectivement, de l’ISO 5167-2:2022: C = 0,605 1; C = 0,607 0.
F D et D/2
Donc:
0,605 1
δU′=−25 10= ,078
0,607 0
L’incertitude relative élargie du coefficient de décharge à k = 2 (niveau de confiance de 95 % environ)
est de 0,5 % (voir l’ISO 5167-2:2022, 5.3.3.1).
Par conséquent, l’incertitude relative élargie globale du coefficient de décharge à k = 2 (niveau de
confiance de 95 % environ) est de 0,5 + 0,078 ≈ 0,6 % (c’est-à-dire que les incertitudes ont simplement
été additionnées).
6.5 État des prises de pression
L’expérience a montré que des erreurs importantes peuvent être générées par des prises de pression
comportant des bavures ou des dépôts sur ou près de l’arête où la prise de pression pénètre dans la
paroi de la conduite. Cela est particulièrement le cas lorsque les prises de pression sont dans le flux
principal, par exemple prises au col dans les tuyères ou tubes de Venturi, où de petites bavures peuvent
donner lieu à des erreurs en pourcentage significatives. Des prises dans les angles en amont et des prises
en aval dans des zones relativement mortes sont beaucoup moins susceptibles de causer ce problème.
L’installation est inspectée avant utilisation et à intervalles réguliers pour s’assurer que ces anomalies
ne sont pas présentes.
7 Effets du positionnement de la canalisation près de l’organe déprimogène
7.1 Diamètre de la conduite
Le diamètre intérieur de la conduite en amont et en aval de l’élément primaire est toujours mesuré
pour s’assurer qu’il est conforme à l’ISO 5167-2:2022, 6.4, l’ISO 5167-3:2022, 6.4 ou l’ISO 5167-4:2022,
6.4.1. Des erreurs dans le mesurage du diamètre intérieur en amont engendrent des erreurs de calcul
du débit, qui sont données par la Formule (4):
δ
q −2
β δD
m
= (4)
D
q
()1−
β
m
Ces erreurs deviennent significatives pour un β élevé, par exemple avec β = 0,75, une erreur positive de
1 % sur D engendre une erreur négative de 1 % sur q .
m
La conduite aval est beaucoup moins critique, étant donné que pour un diaphragme, une tuyère
ISA 1932 ou une tuyère à long rayon, son diamètre doit seulement être égal à celui de la conduite amont
à 3 % près (voir l’ISO 5167-2:2022, 6.4.6 ou l’ISO 5167-3:2022, 6.4.6) et pour un Venturi-tuyère ou
un tube de Venturi, son diamètre doit seulement être ≥ 90 % du diamètre à la fin du divergent (voir
l’ISO 5167-3:2022 6.4.6 ou l’ISO 5167-4:2022, 6.4.1.3).
7.2 Variations du diamètre interne de la conduite
Les élargissements soudains de la conduite à proximité de l’élément primaire sont toujours à éviter, car
cela engendre de grandes erreurs de mesurage du débit. De même, les sections coniques de conduite
peuvent conduire à des erreurs significatives, comme le montre le Tableau 2, qui indique l’ordre de
grandeur des erreurs pouvant être attendues lorsqu’un diaphragme avec des prises dans les angles est
immédiatement précédé ou suivi d’une pièce conique.
Les informations données dans le Tableau 2 indiquent qu’il est déconseillé d’utiliser une pièce conique
divergente dans le sens de l’écoulement, placée immédiatement en amont, car le coefficient de décharge
augmente alors jusqu’à 50 %. En revanche, une pièce conique convergente, qu’elle soit installée avant ou
après le diaphragme, et à condition qu’elle ne soit pas à un angle plus élevé que ceux illustrés, conduit à
des variations du coefficient généralement inférieures à 2 %.
Tableau 2 — Effet des pièces coniques
Ordre de grandeur de la variation
Position du diaphragme β du coefficient de décharge
à prévoir
%
a) Immédiatement en aval d’une pièce conique divergente
0,4 +10
0,7 +50
b) Immédiatement en aval d’une pièce conique convergente
0,4 −0,5
0,7 −2
c) Immédiatement en amont d’une pièce conique convergente
0,4 0 à −1
0,7 +1
7.3 Diamètre de la bague porteuse
Les exigences de dimensionnement et de montage concentrique des bagues porteuses pour les
diaphragmes et les tuyères sont spécifiées dans l’ISO 5167-2:2022, 6.4 et 6.5, l’ISO 5167-3:2022, 6.4
et 6.5 et l’ISO 5167-2:2022, Figure 4. Si l’exigence de l’ISO 5167-2:2022, 6.5.4 et l’ISO 5167-3:2022,
6.5.4 (à savoir qu’il est recommandé que les bagues porteuses soient centrées de façon qu’elles ne
s’avancent pas dans la conduite) ne sont pas satisfaites, des erreurs de mesurage du débit relativement
importantes sont introduites. La Figure 3 représente une telle installation et la Figure 4, qui utilise la
même notation, montre les erreurs approximatives introduites dans les conditions indiquées, où a est
la largeur de la portion de la bague porteuse en amont de la face amont du diaphragme ou de la tuyère.
Il faut rappeler que pour arriver à ces erreurs, le diamètre intérieur de la bague porteuse, D , et non le
diamètre de la conduite principale, a été utilisé pour déterminer le débit calculé, et qu’il doit être utilisé
en remplacement de D pour déterminer le facteur de correction à l’aide des valeurs indiquées.
Lorsque la bague est surdimensionnée, des résultats expérimentaux montrent que pour β = 0,74, une
bague porteuse de 11 % trop grande et qui s’étend jusqu’à 0,05D en amont du diaphragme augmente le
coefficient de décharge d’environ 0,5 %. Cependant, pour une géométrie similaire, mais avec β = 0,63,
aucun effet n’a été observé.
a) Diaphragme
b) Tuyère
a
Sens de l’écoulement.
Figure 3 — Bague porteuse avec un diamètre intérieur, D , inférieur au diamètre de la conduite,
D
a) Diaphragme
b) Tuyère
Légende
X rapport des diamètres
Y variation du coefficient de décharge (%)
1 a = 0,2D à 0,3D
Figure 4 — Effet du diamètre incorrect de la bague porteuse
7.4 Joints circulaires sous-dimensionnés
Lorsque le diamètre intérieur d’un joint circulaire ou d’un joint d’étanchéité est plus petit que le diamètre
de la conduite, en particulier du côté amont d’un diaphragme ou d’une tuyère, il peut éventuellement se
produire de très grandes erreurs de mesurage du débit. L’amplitude et le signe de l’effet en relation
avec le mesurage du débit dépendent de la combinaison d’un certain nombre de variables, par exemple
l’épaisseur du joint circulaire en amont du diaphragme, l’étendue de son dépassement dans l’écoulement,
sa position par rapport au diaphragme et aux prises de pression, et le degré de rugosité de la conduite
amont.
7.5 Soudures saillantes
L’effet d’une soudure circonférentielle non rectifiée qui dépasse dans l’orifice de la conduite adjacente
à l’élément primaire est similaire à celui d’un joint circulaire sous-dimensionné. Il se pourrait qu’un
tel effet provienne du montage d’une bride à collerette soudée, et l’amplitude de l’effet dépend de
l’uniformité ou non de la hauteur de la soudure saillante et de sa position par rapport au dispositif
de prises de pression (simple ou multiple) pour mesurer la pression différentielle à travers l’élément
primaire. Il est difficile de quantifier l’erreur résultante dans une situation spécifique sans étalonnage
direct.
Une conduite fabriquée par soudage est acceptable, à condition que le cordon de soudure intérieur soit
parallèle à l’axe de la conduite sur toute la longueur nécessaire pour satisfaire aux exigences spécifiques
concernant l’élément primaire utilisé, et que la hauteur du cordon de soudure ne soit en aucun cas
supérieure à l’écart des diamètres autorisés. La soudure ne doit pas être située dans un secteur de ± 30°
centré sur l’une quelconque des prises de pression destinée à être utilisée avec l’élément primaire,
sauf si une fente annulaire est utilisée. Si une fente annulaire est utilisée, l’emplacement de la soudure
n’est pas important. Si une conduite spiralée est utilisée, elle doit être usinée pour la rendre lisse (voir
l’ISO 5167-1:2022, 7.1.4).
7.6 Excentricité
Les exigences pour le montage concentrique de l’appareil sont données dans l’ISO 5167-2:2022,
6.5.3 et 6.5.4, l’ISO 5167-3:2022, 6.5.3 et 6.5.4 et l’ISO 5167-4:2022, 6.4.1. La mesure géométrique de
l’excentricité est la distance entre les axes de la conduite et du diaphragme et est souvent exprimée
en pourcentage du diamètre interne de la conduite, D. La Figure 5 montre le montage excentré d’un
diaphragme dans une direction latérale par rapport à la canalisation amont. Le déplacement se fait vers
la droite et l’excentricité est une combinaison des tolérances dimensionnelles sur le diamètre du cercle
primitif de boulon, le diamètre du boulon, le diamètre du trou de boulon et le diamètre extérieur du
diaphragme.
Les preuves expérimentales des effets de l’excentricité sont limitées, mais il a été démontré que pour
les diaphragmes, l’effet sur le coefficient de décharge est fonction de β, du diamètre et de la rugosité de
la conduite, du type de prise de pression, de l’emplacement et de l’amplitude, ainsi que de la position du
centre de l’orifice par rapport à la prise de pression.
Des travaux expérimentaux indiquent que les erreurs dues à l’excentricité augmentent en général avec
β. Pour β = 0,2 et une excentricité allant jusqu’à 5 % de D, il est peu probable que les augmentations
du coefficient de décharge dépassent 0,1 %. Pour de plus grands β, les variations apparaissent plus
facilement sur un graphique, comme illustré à la Figure 6.
En dessous de 3 % d’excentricité, l’erreur varie avec le type de prise de pression et la direction
d’excentricité. Le diaphragme est moins sensible à l’excentricité perpendiculaire aux prises de pression.
En dessus de 3 % d’excentricité, les erreurs augmentent rapidement pour toutes les prises de pression
et toutes les directions.
NOTE Il n’y a pas de données disponibles pour les prises dans les angles, mais les erreurs sont probablement
similaires à celles des prises à la bride, étant donné que les données ci-dessus ont été obtenues sur une ligne
d’essai avec D = 150 mm.
L’augmentation de l’instabilité du signal de pression différentielle obtenu est un autre effet du
positionnement excentré d’un diaphragme. Des observations ont montré, par exemple, une
augmentation marquée des fluctuations de pression différentielle lorsque l’excentricité augmente, pour
toutes les valeurs de β comprises entre 0,4 et 0,7.
L’effet de l’excentricité sur le mesurage du débit est difficile à quantifier en raison du nombre de
variantes qui y contribuent. Il est très important de restreindre l’excentricité à moins de 3 % de D, en
particulier dans la direction des prises de pression.
L’effet de l’excentricité est minimisé en utilisant quatre prises de pression régulièrement espacées en
amont et en aval du débitmètre, comme illustré dans l’ISO 5167-1:2022, Figure 1. Les lignes de pression
partant de celles-ci sont alors couplées dans une disposition très courante en triple T, afin d’obtenir une
mesure de pression différentielle moyenne.
À titre de guide général, une hypothèse raisonnable est que les effets du montage excentré pour des
tuyères à plusieurs prises seront moins importants que pour des diaphragmes de β équivalent. Les
tubes de Venturi sont moins susceptibles d’être installés de manière décentrée.
NOTE Défauts d’installation combinés: il est recommandé de ne pas prendre en compte les erreurs dues
aux effets combinés de l’excentricité, des écarts des bagues porteuses, etc., en les additionnant. L’erreur totale
possible sera fonction du plus important des effets présents.
Légende
1 cercle primitif de boulon
2 axe de la bride
3 orifice
4 diamètre extérieur du diaphragme
5 orifice de la bride
6 diamètre intérieur de la conduite
7 axe de la conduite
8 axe de l’orifice
9 excentricité
Figure 5 — Excentricité possible du diaphragme résultant des tolérances spécifiées sur
le trou de boulon, le cercle primitif de boulon, le diamètre extérieur de la conduite et l’orifice
de la bride
a) β = 0,75 b) β = 0,66
c) β = 0,57
Légende
X excentricité (%)
Y variation du coefficient de décharge (%)
prises à D et D/2
prises à la bride
a
±0,3 %.
b
(loin de la prise 1) ← → (en direction de la prise 1).
c
±0,5 %.
d
±0,7 %.
Figure 6 — Erreur du coefficient de décharge en fonction de l’excentricité pour un diaphragme
avec des prises à D et D/2 et des prises à la bride
8 Effets de la disposition de la conduite
8.1 Généralités
Les valeurs minimales des longueurs droites nécessaires entre l’élément primaire et les divers accessoires
en amont sont indiquées dans l’ISO 5167-2:2022, 6.2, l’ISO 5167-3:2022, 6.2 et l’ISO 5167-4:2022, 6.2. Les
longueurs droites minimales sont données à la fois pour une «incertitude supplémentaire nulle» et pour
une «incertitude supplémentaire de 0,5 %» du coefficient de décharge.
Lorsque les exigences minimales ne peuvent pas être satisfaites même pour une «incertitude
supplémentaire de 0,5 %», il est judicieux que l’utilisateur effectue une correction pour compenser
la variation du coefficient de décharge et qu’il augmente la valeur de l’incertitude exprimée en
pourcentage.
Les Tableaux 3 et 4 indiquent des corrections et des incertitudes supplémentaires pour des diaphragmes
à arête rectangulaire avec des prises dans les angles, à la bride et à D et D/2, pour une variété de coudes
et d’accessoires de conduite amont. Les corrections dans les colonnes 4 et 5 sont particulièrement
variables, en fonction des détails exacts du double coude.
Les Références [8] à [11] fournissent des données supplémentaires sur les corrections des coefficients
de décharge des diaphragmes pour un grand nombre d’accessoires amont.
8.2 Modifications du calcul du coefficient de décharge
8.2.1 Corrections
Le coefficient de décharge peut être corrigé à l’aid
...
Frequently Asked Questions
ISO/TR 12767:2023 is a technical report published by the International Organization for Standardization (ISO). Its full title is "Measurement of fluid flow by means of pressure differential devices - Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167". This standard covers: This document provides guidance on estimating the flowrate when using pressure differential devices constructed or operated outside the scope of ISO 5167 series. Additional tolerances or corrections cannot necessarily compensate for the effects of deviating from ISO 5167 series. The information is given, in the first place, to indicate the degree of care necessary in the manufacture, installation and maintenance of pressure differential devices by describing some of the effects of non-conformity to the requirements; and in the second place, to permit those users who cannot comply fully with the requirements to assess, however roughly, the magnitude and direction of the resulting error in flowrate. Each variation dealt with is treated as though it were the only one present. Where more than one is known to exist, there might be unpredictable interactions and care has to be taken when combining the assessment of these errors. If there is a significant number of errors, means of eliminating some of them have to be considered. The variations included in this document are by no means complete and relate largely to examples with orifice plates. An example with Venturi tubes has been placed at the end of its section. This document does not apply to cone meters or wedge meters. There are, no doubt, many similar examples of installations not conforming to ISO 5167 series for which no comparable data have been published. Such additional information from users, manufacturers and any others can be taken into account in future revisions of this document.
This document provides guidance on estimating the flowrate when using pressure differential devices constructed or operated outside the scope of ISO 5167 series. Additional tolerances or corrections cannot necessarily compensate for the effects of deviating from ISO 5167 series. The information is given, in the first place, to indicate the degree of care necessary in the manufacture, installation and maintenance of pressure differential devices by describing some of the effects of non-conformity to the requirements; and in the second place, to permit those users who cannot comply fully with the requirements to assess, however roughly, the magnitude and direction of the resulting error in flowrate. Each variation dealt with is treated as though it were the only one present. Where more than one is known to exist, there might be unpredictable interactions and care has to be taken when combining the assessment of these errors. If there is a significant number of errors, means of eliminating some of them have to be considered. The variations included in this document are by no means complete and relate largely to examples with orifice plates. An example with Venturi tubes has been placed at the end of its section. This document does not apply to cone meters or wedge meters. There are, no doubt, many similar examples of installations not conforming to ISO 5167 series for which no comparable data have been published. Such additional information from users, manufacturers and any others can be taken into account in future revisions of this document.
ISO/TR 12767:2023 is classified under the following ICS (International Classification for Standards) categories: 17.120.10 - Flow in closed conduits. The ICS classification helps identify the subject area and facilitates finding related standards.