ISO 21268-2:2019
(Main)Soil quality — Leaching procedures for subsequent chemical and ecotoxicological testing of soil and soil-like materials — Part 2: Batch test using a liquid to solid ratio of 10 l/kg dry matter
Soil quality — Leaching procedures for subsequent chemical and ecotoxicological testing of soil and soil-like materials — Part 2: Batch test using a liquid to solid ratio of 10 l/kg dry matter
This document specifies a test providing information on leaching of soil and soil materials under the experimental conditions specified hereafter, and particularly at a liquid to solid ratio of 10 l/kg dry matter. The document has been developed to measure the release of inorganic and organic substances from soil and soil-like material as well as to produce eluates for subsequent ecotoxicological testing. For ecotoxicological testing, see ISO 15799[6] and ISO 17616[7]. NOTE 1 Volatile organic substances include the low-molecular-weight substances in mixtures such as mineral oil. NOTE 2 It is not always possible to optimize test conditions simultaneously for inorganic and organic substances and optimum test conditions can also vary between different groups of organic substances. Test requirements for organic substances are generally more stringent than those for inorganic substances. The test conditions suitable for measuring the release of organic substances will generally also be applicable to inorganic substances. NOTE 3 Within the category of organic substances, a significant difference in behaviour exists between the more polar, relatively water-soluble compounds and apolar, hydrophobic organic substances (HOCs). In the latter case, mechanisms of release (e.g. particle-bound or dissolved organic carbon-bound) can be more crucial as well as sorption losses of soluble HOCs on different materials with which they come in contact (e.g. bottles, filters). The test and the results should be used for leaching of organic substances only with thorough consideration of the specific properties of the substances in question and the associated potential problems. NOTE 4 For ecotoxicological testing, eluates representing the release of both inorganic and organic substances are needed. In this document, ecotoxicological testing is also meant to include genotoxicological testing. This test method produces eluates, which can subsequently be characterized by physical, chemical and ecotoxicological methods in accordance with existing standard methods. The test is not suitable for substances that are volatile under ambient conditions. This procedure is not applicable to materials with a dry-matter-content ratio lower than 33 %. This test is mainly aimed at being used for routine and control purposes, and it cannot be used alone to describe all leaching properties of a soil. Additional leaching tests are needed for that extended goal. This document does not address issues related to health and safety. It only determines the leaching properties as outlined in Clause 4.
Qualité du sol — Modes opératoires de lixiviation en vue d'essais chimiques et écotoxicologiques ultérieurs des sols et matériaux du sol — Partie 2: Essai en bâchée avec un rapport liquide/solide de 10 l/kg de matière sèche
Le présent document spécifie un essai fournissant des informations sur la lixiviation des sols et des matériaux du sol dans les conditions expérimentales spécifiées ci-après, et notamment un rapport liquide/solide égal à 10 l/kg de matière sèche. Le présent document a été conçu pour étudier le relargage de substances organiques et inorganiques à partir du sol et des matériaux analogues au sol et produire des éluats destinés aux essais écotoxicologiques. Pour en savoir plus sur les essais écotoxicologiques, voir l'ISO 15799[6] et l'ISO 17616[7]. NOTE 1 Les substances organiques volatiles comprennent les substances à faible masse moléculaire contenues dans des mélanges tels que les huiles minérales. NOTE 2 Il n'est pas toujours possible d'optimiser les conditions d'essai à la fois pour les substances organiques et les substances inorganiques. Les conditions d'essai optimales peuvent également varier entre les différents groupes de substances organiques. Les exigences d'essai pour les substances organiques sont généralement plus strictes que celles applicables aux substances inorganiques. En règle générale, les conditions d'essai appropriées à la mesure du relargage des substances organiques s'appliquent également aux substances inorganiques. NOTE 3 Au sein de la catégorie des substances organiques, une différence de comportement notable existe entre les composés les plus polaires, relativement solubles dans l'eau et les composés organiques hydrophobes (COH), apolaires. Concernant ces derniers, les mécanismes de relargage (par exemple liés à des particules ou liés au carbone organique dissous) peuvent avoir plus d'importance, de même que les pertes dues à la sorption de COH solubles sur différents matériaux avec lesquels ils entrent en contact (par exemple flacons, filtres). Il convient d'utiliser les essais et les résultats pour la lixiviation des substances organiques, uniquement en ayant une connaissance approfondie des propriétés spécifiques des substances en question et des problèmes potentiels qui y sont associés. NOTE 4 Pour les essais d'écotoxicité, des éluats avec à la fois des substances inorganiques et organiques sont nécessaires. Dans le présent document, les essais d'écotoxicité englobent les essais de génotoxicité. Cette méthode d'essai produit des éluats qui peuvent ensuite être caractérisés par des méthodes physiques, chimiques et écotoxicologiques selon des méthodes normalisées existantes. L'essai n'est pas adapté aux substances qui sont volatiles dans des conditions ambiantes. Ce mode opératoire ne s'applique pas aux matériaux ayant un taux de matière sèche inférieur à 33 %. Cet essai est principalement destiné à être utilisé à des fins de vérification de routine et de contrôle, et il ne peut pas, à lui seul, être utilisé pour déterminer toutes les propriétés de lixiviation d'un sol. D'autres essais sont nécessaires pour atteindre cet objectif plus large. Le présent document ne traite pas des questions liées à la santé et à la sécurité. Il permet uniquement de déterminer les propriétés de lixiviation telles que décrites dans l'Article 4.
General Information
Relations
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 21268-2
First edition
2019-09
Soil quality — Leaching procedures
for subsequent chemical and
ecotoxicological testing of soil and
soil-like materials —
Part 2:
Batch test using a liquid to solid ratio
of 10 l/kg dry matter
Qualité du sol — Modes opératoires de lixiviation en vue d'essais
chimiques et écotoxicologiques ultérieurs des sols et matériaux du
sol —
Partie 2: Essai en bâchée avec un rapport liquide/solide de 10 l/kg de
matière sèche
Reference number
©
ISO 2019
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 3
5 Reagents . 3
6 Apparatus . 4
7 Sample pretreatment . 5
7.1 Preparation of laboratory sample and specification of particle size . 5
7.2 Preparation of test sample . 6
7.3 Determination of dry matter content and water content . 6
7.4 Preparation of the test portion . 7
8 Procedure. 7
8.1 Temperature . 7
8.2 Description of the procedure . 7
8.2.1 Preparation of the eluent . 7
8.2.2 Leaching step . 7
8.2.3 Liquid/Solid separation step . 8
8.3 Further preparation of the eluate for analysis. 9
8.4 Blank test for the application of the leaching procedure . 9
9 Calculation .10
10 Test report .10
11 Analytical determination .11
11.1 General .11
11.2 Blank test information .11
12 Performance characteristics .11
12.1 General .11
12.2 Validation results obtained for DIN 19529 .11
12.2.1 General.11
12.2.2 Results for test material containing inorganic substances .12
12.2.3 Results for test materials containing organic substances .12
Annex A (informative) Information on the influence on the test results of the parameters
that affect leaching .20
Annex B (informative) Example of a specific liquid-solid separation procedure for soil
samples (applying only to the leaching of inorganic substances) .23
Annex C (informative) Calculation of centrifugation duration depending on centrifugation
speed and rotor dimensions.25
Bibliography .27
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see www .iso
.org/iso/foreword .html.
This document was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 7,
Impact assessment.
This first edition of ISO 21268-2:2019 cancels and replaces the first edition (ISO/TS 21268-2:2007),
which has been technically revised. The main changes compared to the previous edition are as follows:
— the maximum grain size has been changed to <2 mm as usual for soil;
— the demineralized water has been added as possible leachant;
— 7.1 and 7.2 have been renumbered and renamed to read 7.1 "Particle size" and 7.2 "Sample
preparation";
— 12.1 "General" and 12.2 "Validation results obtained for DIN 19529" have been added;
— A.3.6 "Special requirements for tests considering semi-volatile substances" has been added;
— a new informative Annex C "Calculation of centrifugation duration depending on centrifugation
speed and rotor dimensions" has been added;
— references in Clause 2 and the Bibliography have been updated.
A list of all parts in the ISO 21268 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2019 – All rights reserved
Introduction
In various countries, tests have been developed to characterize and assess the substances which can
be released from materials. The release of soluble substances upon contact with water is regarded as
a main mechanism of release, which results in a potential risk to the environment during the use or
disposal of materials. The intent of these tests is to identify the leaching properties of materials. The
[1]
complexity of the leaching process makes simplifications necessary .
Not all of the relevant aspects of leaching behaviour can be addressed in one standard (see description
of influencing factors in Annex A).
Tests to characterize the behaviour of materials can generally be divided into three categories addressed
[2] [3]
in ISO 18772 and EN 12920 . The relationships between these tests are summarized below.
a) “Basic characterization” tests are used to obtain information on the short- and long-term
leaching behaviour and characteristic properties of materials. Liquid/solid ratios (L/S), leachant
composition, factors controlling leachability, such as pH, redox potential, complexing capacity, role
of dissolved organic carbon (DOC), ageing of material and physical parameters, are addressed in
these defined tests.
b) “Compliance” tests are used to determine whether the material complies with a specific behaviour
or with specific reference values. These tests focus on key variables and leaching behaviour
previously identified by basic characterization tests.
c) “On-site verification” tests are used as a rapid check to confirm that the material is the same as that
which has been subjected to the compliance test(s). On-site verification tests are not necessarily
leaching tests.
The test procedure described in this method belongs to category b): compliance tests.
[4]
This document was originally elaborated on the basis of EN 12457-2:2004 . Especially, modifications
considering requirements on subsequent ecotoxicological testing and analysis of organic substances
[5]
have been included. Validation results have been adopted from DIN 19529 .
INTERNATIONAL STANDARD ISO 21268-2:2019(E)
Soil quality — Leaching procedures for subsequent
chemical and ecotoxicological testing of soil and soil-like
materials —
Part 2:
Batch test using a liquid to solid ratio of 10 l/kg dry matter
1 Scope
This document specifies a test providing information on leaching of soil and soil materials under the
experimental conditions specified hereafter, and particularly at a liquid to solid ratio of 10 l/kg dry matter.
The document has been developed to measure the release of inorganic and organic substances from
soil and soil-like material as well as to produce eluates for subsequent ecotoxicological testing. For
[6] [7]
ecotoxicological testing, see ISO 15799 and ISO 17616 .
NOTE 1 Volatile organic substances include the low-molecular-weight substances in mixtures such as
mineral oil.
NOTE 2 It is not always possible to optimize test conditions simultaneously for inorganic and organic
substances and optimum test conditions can also vary between different groups of organic substances. Test
requirements for organic substances are generally more stringent than those for inorganic substances. The test
conditions suitable for measuring the release of organic substances will generally also be applicable to inorganic
substances.
NOTE 3 Within the category of organic substances, a significant difference in behaviour exists between the
more polar, relatively water-soluble compounds and apolar, hydrophobic organic substances (HOCs). In the latter
case, mechanisms of release (e.g. particle-bound or dissolved organic carbon-bound) can be more crucial as well
as sorption losses of soluble HOCs on different materials with which they come in contact (e.g. bottles, filters).
The test and the results should be used for leaching of organic substances only with thorough consideration of
the specific properties of the substances in question and the associated potential problems.
NOTE 4 For ecotoxicological testing, eluates representing the release of both inorganic and organic substances
are needed. In this document, ecotoxicological testing is also meant to include genotoxicological testing.
This test method produces eluates, which can subsequently be characterized by physical, chemical and
ecotoxicological methods in accordance with existing standard methods. The test is not suitable for
substances that are volatile under ambient conditions.
This procedure is not applicable to materials with a dry-matter-content ratio lower than 33 %.
This test is mainly aimed at being used for routine and control purposes, and it cannot be used alone
to describe all leaching properties of a soil. Additional leaching tests are needed for that extended goal.
This document does not address issues related to health and safety. It only determines the leaching
properties as outlined in Clause 4.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 5667-3, Water quality — Sampling — Part 3: Preservation and handling of water samples
ISO 7027-1, Water quality — Determination of turbidity — Part 1: Quantitative methods
ISO 10523, Water quality — Determination of pH
ISO 11465, Soil quality — Determination of dry matter and water content on a mass basis —
Gravimetric method
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
3.1
leaching test
test during which a material is put into contact with a leachant (3.2) under strictly defined conditions
and some substances of the material are extracted
3.2
leachant
liquid used in a leaching test (3.1)
Note 1 to entry: For the purpose of this document, the leachant is specified in 5.1.
3.3
eluate
solution recovered from a leaching test (3.1)
Note 1 to entry: Eluate is also referred to as leachate.
3.4
liquid to solid ratio
L/S
ratio between the total volume of liquid (L in litres), which in this extraction is in contact with the soil
sample, and the dry mass of the sample (S in kg of dry matter)
Note 1 to entry: L/S is expressed in l/kg.
3.5
dry matter content
w
dm
ratio, expressed in percent, between the mass of the dry residue, determined in accordance with
ISO 11465, and the corresponding raw mass
3.6
water content
w
HO
ratio, expressed in percent, between the mass of water contained in the material as received and the
corresponding dry residue of the material
Note 1 to entry: The basis for the calculation of the water content is the mass of the dry residue in this document,
as specified in ISO 11465 (for the determination of the water content of soil).
2 © ISO 2019 – All rights reserved
3.7
laboratory sample
sample or sub-sample(s) sent to or received by the laboratory
3.8
test sample
sample, prepared from the laboratory sample (3.7), from which test portions (3.9) are removed for
testing or analysis
3.9
test portion
quantity of material of appropriate size for measurement of the concentration or other properties of
interest taken from the test sample (3.8)
Note 1 to entry: The test portion can be taken from the laboratory sample (3.7) directly if no pre-treatment of the
sample is required, but usually it is taken from the test sample.
Note 2 to entry: A unit or increment of proper homogeneity, size and fineness, needing no further preparation,
can be a test portion.
3.10
soil-like material
[7]
excavated soil, dredged materials, manufactured soils, treated soils and fill materials
4 Principle
The test portion, which originally or after suitable pre-treatment has a particle size less than or equal
to 2 mm, is brought into contact with water containing a low concentration (0,001 mol/l) of calcium
chloride or demineralized water (5.1) under defined conditions. The standard method is based on the
assumption that equilibrium or near-equilibrium is achieved between the liquid and solid phases during
the test period. The solid residue is subsequently separated from the liquid. The separation procedure
may strongly influence the test results and shall be particularly stringent for organic substances. The
properties of the eluate are measured using methods developed for water analysis adapted to meet
criteria for analysis of eluates, and the eluate may be subjected to subsequent ecotoxicological testing.
After the test, the leaching conditions imposed by the material, in terms of pH, electrical conductivity
and, optionally, DOC, redox potential or turbidity, shall be recorded.
NOTE 1 These parameters often control the leaching behaviour of soil and soil-like materials and are therefore
important for evaluation of the test results. DOC, in particular, is crucial in soil and soil materialsoil-like materials
for many inorganic and organic substances.
NOTE 2 The leachant is 0,001 mol/l CaCl to minimize the mobilization of DOC caused by an ionic strength of
the leachant which is too low.
The procedure described in this document is based on the more stringent test requirements for
determining the release of organic substances and for subsequent ecotoxicological testing. If only the
release of inorganic substances is to be measured, less stringent requirements may be adopted for some
steps of the procedure.
5 Reagents
5.1 Demineralized water or deionized water or water of equivalent purity (5 < pH < 7,5) with a
conductivity of <0,5 mS/m in accordance with grade 3 specified in ISO 3696 made to 0,001 mol/l CaCl .
5.2 Calcium chloride (CaCl · 2 H O), analytical grade.
2 2
5.3 Sodium azide (NaN ), analytical grade.
5.4 Nitric acid (HNO ), analytical grade, made to 0,1 mol/l rinsing solution.
5.5 Organic solvent (acetone, analytical grade) for rinsing and cleaning.
6 Apparatus
6.1 Borosilicate glass, of high purity in accordance with ISO 5667-3, with a nominal volume of 1 l,
glass bottles having caps of inert material, for example PTFE (polytetrafluoroethylene). Rinsing is
compulsory and it should be assured that previously used bottles have no background level of analytes.
NOTE 1 If only inorganic parameters are analysed, alternative materials, such as HDPE/PP bottles, are
appropriate, except for unpreserved samples for mercury analysis.
NOTE 2 To prevent organic compounds from degradation by light use a dark room, dark colored glassware or
place a layer of aluminium-foil around the leaching equipment.
If boron analyses are necessary, any plastics bottles can be used, e.g. PTFE (polytetrafluoroethylene).
The volume of 1 l is selected in combination with the mass, m , of 100 g as specified in 7.4 in order to
D
minimize head-space in the bottle at an L/S of 10 l/kg dry matter. In the case of materials with low
density, deviation from this requirement can be necessary while still ensuring minimum headspace.
This deviation shall be reported.
NOTE 3 Glass of high quality is considered adequate for both metals and organic substances, particularly,
since the pH range usually covered in soil testing does not reach the conditions (pH > 10 and pH < 3) where glass
itself can be partially dissolved. For ecotoxicity testing, eluates with both inorganic and organic substances are
needed, which emphasizes the need to generate integrated eluates.
NOTE 4 Heat treatment of used glassware at 550 °C can be used to remove traces of analytes. However, this
treatment has been shown to increase adsorption of organic substances from the air.
6.2 Glass bottle, of high quality (requirements as in 6.1) with a nominal volume of e.g. 5 l, to be used
when samples from replicate tests are recombined after centrifugation for further analysis or testing.
−1 −1 −1
6.3 End-over-end tumbler (5 min to 10 min ) or roller table, rotating at about 10 min .
Other shaking devices may be used provided that they can be shown to provide equivalent results.
These agitation devices are specified because excessive abrasion leading to significant particle size
reduction should be avoided.
6.4 Filtration apparatus, either a vacuum filtration device (between 2,5 kPa and 4,0 kPa) or a
high-pressure filtration apparatus (<0,5 MPa). Rinsing is compulsory. When semi-volatile substances are
to be analysed, vacuum filtration shall not be used.
6.5 0,45 µm membrane filters, pre-rinsed or similarly cleaned [e.g. rinsed with 0,1 mol/l HNO (5.2)
and water (5.1)] (only for analysis of inorganic substances).
The filters shall be chosen so as not to adsorb (or release) substances of interest.
NOTE This can be tested in preliminary experiments.
6.6 Glass fibre filters, with a degree of separation of 0,7 µm.
The filters shall be chosen so as not to adsorb (or release) substances of interest.
NOTE This can be tested in preliminary experiments.
6.7 Sieving equipment, with sieves of 2 mm nominal screen size.
4 © ISO 2019 – All rights reserved
NOTE Due to sieving, contamination of the sample can occur to an extent which affects the leaching of some
substances of concern, e.g. chromium, nickel and molybdenum from stainless steel equipment or plasticizers
from plastic sieves.
6.8 Centrifuge, operating at 20 000 g to 30 000 g using centrifuge tubes of PFA (perfluoroalkoxy
alkane), fluorinated ethylene propylene (FEP) or tubes of an alternative material which is inert with
[8]
regard to both inorganic and organic compounds and suitable for high-speed centrifugation .
NOTE Potential sorption of hydrophobic organic substances to the centrifuge tubes can be tested in
preliminary experiments.
Alternatively, if a high-speed centrifuge is not available, a centrifuge operating at 2 000 g to 3 000 g
using glass bottles may be used in combination with increased centrifugation time. Cooling shall be
applied to maintain the desired temperature.
6.9 Device for measuring electrical conductivity.
6.10 pH meter, in accordance with ISO 10523 with an accuracy of at least ±0,05 pH units.
6.11 Thermometer, for air temperature measurement.
6.12 Redox potential meter, (optional).
6.13 Balance, with an accuracy of at least 0,1 g.
6.14 Measuring cylinders, for volume determination with 1 % accuracy.
6.15 Sample splitter, for sub-sampling of laboratory samples (optional).
6.16 Turbidity meter, as specified in ISO 7027-1.
6.17 Crushing equipment, a jaw crusher.
NOTE Due to particle size reduction, contamination of the sample can occur to an extent which affects the
leaching of some substances of concern, e.g. chromium, nickel and molybdenum from stainless steel equipment.
7 Sample pretreatment
7.1 Preparation of laboratory sample and specification of particle size
A representative laboratory sample of at least 2 kg (dry matter) is obtained (e.g. as described in
[10-13] [14]
ISO 18400-101, ISO 18400-104, ISO 18400-105, ISO 18400-202 and ISO 23909 ) and shall be
stored in closed packages and at low temperatures (4 °C), in order to avoid unwanted changes in the
[12]
material (see e.g. ISO 18400-105 ).
The test shall be carried out on soil or soil-like material sieved to <2 mm (e.g. as described in
[9]
ISO 11464 ). Oversized material of natural origin in the sample shall be separated and discarded. The
type and amount of all discarded material shall be reported. If oversized material of anthropogenic
origin is present and assumed to contain substances of interest, this part can be subject to alternative
sample preparation or testing.
If the laboratory sample cannot be homogenized or sieved because of its water content, it is allowed in
[9]
this case only to dry the laboratory sample (e.g. as described in ISO 11464 ). The drying temperature
shall not exceed 30 °C.
NOTE 1 Sieving and drying at more than 30 °C, as well as crushing, can lead to a loss of semi-volatile substances
(inorganic and organic) and can alter the leaching characteristics (refer also to A.3.6).
NOTE 2 Due to sieving, contamination of the sample can occur to an extent that affects the leaching of some
substances of concern, e.g. chromium, nickel and molybdenum from stainless steel equipment or plasticizers
from plastic sieves.
NOTE 3 Due to sieving, contamination of the sample can occur to an extent which affects the leaching of some
substances of concern, e.g. chromium, nickel and molybdenum form stainless steel equipment or plasticisers
from plastic sieves.
7.2 Preparation of test sample
Use a sample splitter (6.15) or apply coning and quartering to split the laboratory sample and obtain a test
sample. The size of test sample required depends on the volume of eluate needed for the specific purpose
and the subsequent chemical analysis and/or ecotoxicological tests to be carried out on the eluate.
NOTE 1 If needed for chemical analysis or ecotoxicological testing, larger volumes of eluate can be obtained
by combining eluates from replicate tests after centrifugation (or filtration). Alternatively, larger volumes of
eluate can also be produced in a single test, provided that the ratios in terms of L/S and minimum headspace are
maintained.
NOTE 2 The required amount of the test sample is dependent on the particle size distribution of the soil to be
[14]
analysed (see ISO 23909 ). The specified sample amount will generally be adequate. In specific cases, a smaller
sample amount can be accepted, for instance, if for specific reasons less material is available, provided that the
test can be carried out as specified in 7.2 to 7.4.
7.3 Determination of dry matter content and water content
The whole test sample, complying with the size criterion in 7.1, shall not be further dried. The water
content of the test sample shall be determined on a separate test portion at (105 ± 5) °C. If the soil sample
is air-dried prior to testing, the dry matter content w of the air-dried sample shall be determined
dm
as well. This shall be taken into account when adjusting the L/S. The dry mass of the sample shall be
determined at (105 ± 5) °C in accordance with ISO 11465 and the dry matter content is calculated in
Formula (1).
wm=×100 /m (1)
dm DW
where
w is the dry matter content, expressed in percent (%);
dm
m is the mass of the dried sample, expressed in kilograms (kg);
D
m is the mass of the undried sample, expressed in kilograms (kg).
W
The water content ( w in %) is calculated as following Formula (2):
HO
wm=×100 −mm/ (2)
()
HO WD D
NOTE If volatile or unstable compounds are present in the soil sample, this gravimetric method cannot be
used for accurate determination of the water content.
If, for reasons expressed in 7.1, the material was (partly) dried before sample splitting, the overall mass
loss shall be taken into account.
6 © ISO 2019 – All rights reserved
7.4 Preparation of the test portion
Prepare, from the test sample, a test portion with a total mass m containing (100 ± 5) g (measured with
an accuracy of 0,1 g, 6.13) of dry mass (m ), following Formula (3).
D
mm=×100 /w (3)
Ddm
Use a sample splitter (6.15) or apply coning and quartering to split the sample.
NOTE Sample splitting or coning and quartering can lead to loss of semi-volatile substances (inorganic and
organic).
In view of the minimum requirements of eluate volume for analytical purposes, it may be necessary
to use a larger test portion and a correspondingly larger volume of leachant. This deviation from this
document shall be specified in the test report.
If the test is performed on an air-dried sample, use w instead of w to determine the sample mass
dm,AD dm
of the test portion.
8 Procedure
8.1 Temperature
The compliance test for leaching shall be carried out at room temperature: (22 ± 3) °C.
For material that is very sensitive to biological degradation, performance of the test at reduced
temperature (e.g. 4 °C) and preventing direct exposure to light will limit biological activity significantly.
A reduced temperature may result in slower/lower release of organic substances and hence lower
concentrations of these compounds in the leachates. If the test is modified in this way, this deviation
shall be reported in the test report.
8.2 Description of the procedure
8.2.1 Preparation of the eluent
Prepare a solution made to 0,001 M CaCl by dissolving 0,147 g CaCl in water and dilute to 1 000 ml.
2 2
In special cases (i.e. measurement of Ca and/or chloride in the eluate are of interest or the sample
exhibits an own salt load), water without addition of CaCl can also be used. The leachant type used
shall be recorded in the test report.
NOTE 1 The application of demineralized water as leachant can induce higher turbidity and lower ionic
strength in the eluate for some types of soils (e.g. high content of organic matter) and can cause increased
concentrations of analytes adsorbed to colloids.
NOTE 2 For eluates that are not to be used for ecotoxicological testing, sodium azide (NaN ) can be added
to a resulting concentration of 0,1 % in order to reduce microbial degradation of organic substances. However,
the addition of NaN is known to only minimize biodegradation if a very high but in turn extremely poisonous
concentration in the eluent is applied. Therefore, other appropriate measures can be considered to prevent/
reduce biodegradation in the sample or collected eluate (e.g. application of γ-radiation to the sample, dark and
air-conditioned room, shorter eluate collection periods, etc). If only inorganic compounds are measured, the
addition of NaN is not appropriate.
8.2.2 Leaching step
Place the test portion with the total mass m corresponding to (100 ± 5) g of dry mass m in a bottle (6.1).
D
Depending on the particle size distribution, other test portions may be applied ensuring that a
representative portion is used (see 7.1).
Add an amount of leachant (V ) using a balance (6.13) or measuring cylinder (6.14), to establish a liquid
L
to solid ratio (L/S) of (10 ± 0,2) l/kg during the extraction, following Formula (4). Care shall be taken to
obtain good mixing of solid and liquid.
Vw=−10 / ρ ×100 ×m (4)
()
LH OH OD
where
V is the volume of leachant used (l);
L
m is the dry mass of the test portion (kg);
D
is the density of water (usually taken as 1 kg/l);
ρ
HO
is the water content for the test portion (%).
w
HO
Place the capped bottle in an agitation device (6.3). Agitate for (24 ± 0,5) h.
As an alternative, instead of 24 h, 6 h can be adopted when it can be demonstrated that equilibrium or
semi-equilibrium is reached or a quick turn-around time is required for quality control purposes. In
this case, it shall be recorded that the leaching was carried out for 6 h.
Settling of solids in the bottle during agitation shall be avoided. At the end of the agitation period, the
bottle is removed from the agitation device.
8.2.3 Liquid/Solid separation step
Allow the suspended solids to settle for (15 ± 5) min.
Transfer the supernatant to centrifuge tubes (6.8). The centrifugation containers shall be chosen so as
not to adsorb (or release) analytes.
There are two options for centrifugation:
a) Centrifuge the eluate for 30 min at 20 000g to 30 000g using a high-speed centrifuge (6.8, see also
Annex C).
b) Centrifuge the eluate for 5 h at 2 000g to 3 000g in glass bottles using a lower-speed centrifuge (6.8).
Cooling shall be applied to maintain the temperature at (22 ± 3) °C (see 8.1).
NOTE 1 Based on Stoke's law, the results of both centrifugation methods are expected to be comparable. Other
alternative combinations of centrifugation acceleration and time can be applied given comparable conditions are
calculated related to the specification of the rotor (see guidance in Annex C).
Gentle braking of the centrifuge shall be applied in order to avoid resuspension. The deceleration time
shall not exceed 20 min.
NOTE 2 In case lightweight substances (e.g. coaly particles) are still floating after centrifugation, a glass fibre
filtration (6.6) can be applied to remove such particles or to reduce the turbidity.
After centrifugation, the eluate shall be transferred immediately to an appropriate container for
measurement of pH and redox potential (see also the next-to-last paragraph of 8.2.2) and stored for
subsequent chemical analysis and/or ecotoxicological testing. In general this eluate can be used for
both analyses of inorganic and organic substances.
If only inorganic substances are measured, the centrifugation step can be omitted, and the decanted
eluate can be filtered directly using the appropriate membrane filters (6.5) and a vacuum or pressure
filtration device (6.4), (see Annex B for an example). When this filtration as specified is not possible in
less than 1 h with a liquid flow rate of at least 30 ml/cm /h, a liquid-solid separation procedure, specific
8 © ISO 2019 – All rights reserved
for the considered case, shall be applied. Report the details in the test report. This specific procedure
shall not include the use of additives.
NOTE 3 For inorganic substances, it is often preferable to pre-centrifuge the eluate at 2 000 g to 3 000 g for
20 min before filtration using glass bottles with a screw cap and polytetrafluoroethylene inlay (or, if possible,
using the leaching bottle directly) prior to filtration. Higher speed or longer time can also be applied (see
Annex C).
NOTE 4 Such a specific liquid-solid separation procedure can include settling, pre-filtration on a coarser filter,
centrifugation, filtration on a large-size membrane filter, filtration at high pressure, filtration at increasing high
pressure following a first period without pressure, etc.
NOTE 5 An example of a specific liquid-solid separation procedure is given in Annex B and has been applied to
soil samples.
Determine the volume of eluate, V or record the volume of the aliquot used.
E
Measure immediately electrical conductivity (in mS/m) and pH of the eluate. Measurement of turbidity,
redox potential (E in mV) and DOC is highly recommended.
h
NOTE 6 Information on DOC concentration in the eluate is is relevant both for release of inorganic substances,
as well as for organic substances.
Under certain circumstances, particularly for alkaline eluates, it is recommended to measure the pH of
the raw eluate prior to filtration or centrifugation, since these operations may change the pH of the eluate.
8.3 Further preparation of the eluate for analysis
If necessary, divide the eluate into an appropriate number of sub-samples for different chemical
analyses and store them in accordance with the requirements in ISO 5667-3.
Since eluates for bio-assays should not contain NaN (see 8.2.1, Note 2), microbial degradation of organic
substances may occur during the test and during the period of eluate storage. Therefore, it is highly
recommended to perform bio-assays on eluates containing organic substances as soon as possible after
completion of the leaching test.
8.4 Blank test for the application of the leaching procedure
Blank tests shall be carried out at regular intervals in order to check, as far as possible, how well the
whole procedure is performed. A volume of leachant of 900 ml is submitted to the whole procedure,
starting at 8.2.1 and using no soil sample.
The eluate of this blank test shall fulfil the following minimum requirements: in the eluate of the
blank test, the concentration of each considered element shall be less than 20 % of the concentration
determined in the eluate of the tested material or less than 20 % of the concentration in the eluate of a
limit value to which the measurement result is to be compared. The elements to be considered are all
the elements which are to be determined in the eluate of the tested material.
If the above requirements are not fulfilled, it is necessary to reduce the contamination. The blank test
results shall not be deducted from the results of the material leaching test.
The above provision does not take into account the sieving step, crushing step or the splitting step. In
order to minimize the possible contamination during these three steps, it is recommended to process
a representative portion of the laboratory sample through the sieving device, the crushing device and
through the splitting device and to discard such material thereafter. This provision does not cover the
situation described in the note under 6.6.
9 Calculation
The concentrations of substances in the extraction solution are measured by appropriate analytical
methods. They give concentrations in mg/l. The final result is a mass fraction, calculated on the basis of
the extract solution volume and the mass of the test portion used, in mg/kg dry matter.
Calculate the quantity of a substance leached from the material, based on the dry mass of the original
material, from Formula (5):
AV=×ρρ//mw+×100 (5)
()
()
substL{}DH OH O
where
A is the release of a substance at a L/S = 10 (mg/kg of dry matter);
ρ is the concentration of a particular substance in the eluate (mg/l);
subst
V is the volume of leachant used (l);
L
is the water content as calculated in Formula (2);
w
HO
m is the mass of the dried test portion (kg);
D
is the density of water (usually taken as 1 kg/l).
ρ
HO
10 Test report
The test report shall include the following details:
a) a reference to this document (ISO 21268-2) ;
b) address of laboratory, name of responsible person;
c) any information necessary for the complete identification of the sample;
d) information on sample pretreatment;
e) water content;
f) type of leachant;
g) centrifugation speed/force, time and type of vessels used, temperature readings;
h) detailed description of the filtration step and results of adsorption tests on the filters applied if
hydrophobic organic compounds are reported;
i) the test results including at least pH, electrical conductivity, measured concentrations (mg/l),
released quantities (mg/kg dry matter), and limit of detection for each substance;
j) the blank test results;
k) any details that are optional or any deviations from the specifications of this document, and any
effects which may have affected the results.
10 © ISO 2019 – All rights reserved
11 Analytical determination
11.1 General
Since the analysis step is not included in the scope of this document, the analytical method applied
together with the limit of quantification shall be reported.
11.2 Blank test information
The following shall be included in the test report:
— date of the last blank test performed;
— results of the blank test, including the elements considered for the tested material and the
levels above which the results can be considered as valid, when compared with the measured
concentrations, in mg/l.
12 Performance characteristics
12.1 General
Data on robustness, repeatability and reproducibility of selected inorganic and organic substances are
[5]
available from German research studies for the validation of DIN 19529 based on soils and soil-like
materials (see Table 1 to Table 10). The test conditions are almost the same to this document except the
L/S which was 2 l/kg and the eluent which was always demineralized water. It can be assumed that the
concentrations at L/S 10 l/kg are mostly smaller in comparison to L/S 2 l/kg which may be then close
to detection limits. It has to be noted that particularly for organic substances this may have an effect on
the performance parameters of this procedure.
Membrane filtration at 0,45 μm was used for inorg
...
NORME ISO
INTERNATIONALE 21268-2
Première édition
2019-09
Qualité du sol — Modes opératoires de
lixiviation en vue d'essais chimiques
et écotoxicologiques ultérieurs des
sols et matériaux du sol —
Partie 2:
Essai en bâchée avec un rapport
liquide/solide de 10 l/kg de matière
sèche
Soil quality — Leaching procedures for subsequent chemical and
ecotoxicological testing of soil and soil-like materials —
Part 2: Batch test using a liquid to solid ratio of 10 l/kg dry matter
Numéro de référence
©
ISO 2019
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés
Sommaire Page
Avant-propos .iv
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 2
3 Termes et définitions . 2
4 Principe . 3
5 Réactifs . 4
6 Appareillage . 4
7 Prétraitement des échantillons . 6
7.1 Préparation de l’échantillon pour laboratoire et spécification de la granulométrie . 6
7.2 Préparation de l’échantillon pour essai . 6
7.3 Détermination du taux de matière sèche et du taux d’humidité . 6
7.4 Préparation de la prise d’essai . 7
8 Mode opératoire. 7
8.1 Température . 7
8.2 Description du mode opératoire . 8
8.2.1 Préparation de l’éluant . 8
8.2.2 Étape de lixiviation . 8
8.2.3 Étape de séparation liquide/solide. 8
8.3 Préparation complémentaire de l’éluat pour analyse .10
8.4 Essai à blanc de réalisation du mode opératoire de lixiviation.10
9 Calcul .10
10 Rapport d’essai .11
11 Dosage analytique .11
11.1 Généralités .11
11.2 Informations concernant l’essai à blanc .11
12 Caractéristiques de performance .11
12.1 Généralités .11
12.2 Résultats de validation obtenus pour la méthode DIN 19529 .12
12.2.1 Généralités .12
12.2.2 Résultats d’une prise d’essai contenant des substances inorganiques.12
12.2.3 Résultats de prises d’essai contenant des substances organiques .13
Annexe A (informative) Informations relatives à l’incidence sur les résultats d’essai des
paramètres influençant la lixiviation .20
Annexe B (informative) Exemple de mode opératoire de séparation liquide-solide
spécifique des échantillons de sol (applicable uniquement à la lixiviation des
substances inorganiques) .23
Annexe C (informative) Calcul de la durée de centrifugation en fonction de la vitesse de
centrifugation et des dimensions du rotor .25
Bibliographie .27
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC …, Titre, sous-comité SC …, Titre.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
Le présent document a été élaboré par le comité technique ISO/TC 190, Qualité du sol, sous-comité SC 7,
Évaluation des impacts.
Cette première édition de l'ISO 21268-2:2019 annule et remplace la premier édition
(ISO/TS 21268-2:2007), qui a fait l’objet d’une révision technique. Les principales modifications par
rapport à l’édition précédente sont les suivantes:
— modification de la granulométrie maximale de la prise d’essai, qui doit à présent être inférieure
à 2 mm, ce qui correspond à une valeur habituelle pour les sols;
— ajout de l’eau déminéralisée en tant que lixiviant possible;
— modification de la numérotation et des titres de 7.1 et 7.2, qui sont à présent intitulés
7.1 « Granulométrie » et 7.2 « Préparation des échantillons »;
— ajout de 12.1 « Généralités » et 12.2 « Résultats de validation obtenus pour la méthode DIN 19529 »;
— ajout de A.3.6 « Exigences particulières applicables aux essais en cas de présence de substances
semi-volatiles »;
— ajout d’une nouvelle Annexe C « Calcul de la durée de centrifugation en fonction de la vitesse de
centrifugation et des dimensions du rotor », informative;
iv © ISO 2019 – Tous droits réservés
— mise à jour des références de l’Article 2 et de la Bibliographie.
Une liste de toutes les parties de la série ISO 21268 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
Introduction
Dans plusieurs pays, des essais ont été mis au point pour caractériser et déterminer les substances
pouvant être relarguées à partir de matériaux. Le relargage de substances solubles au contact de
l’eau est considéré comme le principal mécanisme de relargage, qui se traduit par un risque potentiel
pour l’environnement lors de l’utilisation ou l’élimination de ces matériaux. Le but de ces essais est
d’identifier les propriétés de lixiviation des matériaux. La complexité du processus de lixiviation rend
[1]
des simplifications nécessaires .
Tous les aspects importants du comportement à la lixiviation ne peuvent être pris en compte dans une
seule norme (voir la description des facteurs influents à l’Annexe A).
Les essais permettant de caractériser le comportement des matériaux peuvent généralement être
[2] [3]
divisés en trois catégories traitées dans l’ISO 18772 et l’EN 12920. La relation entre ces essais est
résumée ci-après:
a) les essais de « caractérisation de base » sont utilisés pour obtenir des informations sur le
comportement à la lixiviation à court et à long terme, ainsi que sur les propriétés caractéristiques
des matériaux. Le rapport liquide/solide (L/S), la composition du lixiviant, les facteurs contrôlant la
lixiviabilité, tels que le pH, le potentiel redox, la complexation, le rôle du carbone organique dissous
(COD), le vieillissement des matériaux et les paramètres physiques, sont repris dans ces essais;
b) les essais de « conformité » sont utilisés pour déterminer si le matériau est conforme à un
comportement ou à des valeurs de référence spécifiques. Les essais portent plus particulièrement
sur des variables clés et sur le comportement à la lixiviation préalablement identifié par des essais
de caractérisation de base;
c) les essais de « vérification sur site » sont utilisés comme un contrôle rapide pour confirmer que le
matériau est le même que celui qui a été soumis à un ou plusieurs essais de conformité. Les essais
de vérification sur site ne sont pas nécessairement des essais de lixiviation.
Le mode opératoire de l’essai décrit dans la présente méthode appartient à la catégorie b): essais de
conformité.
[4]
La présente norme a été élaborée dans un premier temps sur la base de l’EN 12457-2:2004. Elle a
ensuite été modifiée notamment pour tenir compte des exigences relatives aux essais écotoxicologiques
et à l’analyse ultérieurs des substances organiques. De plus, les résultats de validation obtenus pour la
[5]
méthode DIN 19529 ont été intégrés.
vi © ISO 2019 – Tous droits réservés
NORME INTERNATIONALE ISO 21268-2:2019(F)
Qualité du sol — Modes opératoires de lixiviation en vue
d'essais chimiques et écotoxicologiques ultérieurs des sols
et matériaux du sol —
Partie 2:
Essai en bâchée avec un rapport liquide/solide de 10 l/kg
de matière sèche
1 Domaine d’application
Le présent document spécifie un essai fournissant des informations sur la lixiviation des sols et des
matériaux du sol dans les conditions expérimentales spécifiées ci-après, et notamment un rapport
liquide/solide égal à 10 l/kg de matière sèche.
Le présent document a été conçu pour étudier le relargage de substances organiques et inorganiques
à partir du sol et des matériaux analogues au sol et produire des éluats destinés aux essais
[6]
écotoxicologiques. Pour en savoir plus sur les essais écotoxicologiques, voir l’ISO 15799 et
[7]
l’ISO 17616 .
NOTE 1 Les substances organiques volatiles comprennent les substances à faible masse moléculaire contenues
dans des mélanges tels que les huiles minérales.
NOTE 2 Il n’est pas toujours possible d’optimiser les conditions d’essai à la fois pour les substances organiques
et les substances inorganiques. Les conditions d’essai optimales peuvent également varier entre les différents
groupes de substances organiques. Les exigences d’essai pour les substances organiques sont généralement plus
strictes que celles applicables aux substances inorganiques. En règle générale, les conditions d’essai appropriées
à la mesure du relargage des substances organiques s’appliquent également aux substances inorganiques.
NOTE 3 Au sein de la catégorie des substances organiques, une différence de comportement notable existe
entre les composés les plus polaires, relativement solubles dans l’eau et les composés organiques hydrophobes
(COH), apolaires. Concernant ces derniers, les mécanismes de relargage (par exemple liés à des particules ou
liés au carbone organique dissous) peuvent avoir plus d’importance, de même que les pertes dues à la sorption
de COH solubles sur différents matériaux avec lesquels ils entrent en contact (par exemple flacons, filtres). Il
convient d’utiliser les essais et les résultats pour la lixiviation des substances organiques, uniquement en ayant
une connaissance approfondie des propriétés spécifiques des substances en question et des problèmes potentiels
qui y sont associés.
NOTE 4 Pour les essais d’écotoxicité, des éluats avec à la fois des substances inorganiques et organiques sont
nécessaires. Dans le présent document, les essais d’écotoxicité englobent les essais de génotoxicité.
Cette méthode d’essai produit des éluats qui peuvent ensuite être caractérisés par des méthodes
physiques, chimiques et écotoxicologiques selon des méthodes normalisées existantes. L’essai n’est pas
adapté aux substances qui sont volatiles dans des conditions ambiantes.
Ce mode opératoire ne s’applique pas aux matériaux ayant un taux de matière sèche inférieur à 33 %.
Cet essai est principalement destiné à être utilisé à des fins de vérification de routine et de contrôle,
et il ne peut pas, à lui seul, être utilisé pour déterminer toutes les propriétés de lixiviation d’un sol.
D’autres essais sont nécessaires pour atteindre cet objectif plus large. Le présent document ne traite
pas des questions liées à la santé et à la sécurité. Il permet uniquement de déterminer les propriétés de
lixiviation telles que décrites dans l’Article 4.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s’applique (y compris les
éventuels amendements).
ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
ISO 5667-3, Qualité de l'eau — Échantillonnage — Partie 3: Conservation et manipulation des
échantillons d'eau
ISO 7027-1, Qualité de l’eau — Détermination de la turbidité — Partie 1: Méthodes quantitatives
ISO 10523, Qualité de l'eau — Détermination du pH
ISO 11465, Qualité du sol — Détermination de la teneur pondérale en matière sèche et en eau — Méthode
gravimétrique
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https: //www .iso .org/obp;
— IEC Electropedia: disponible à l’adresse http: //www .electropedia .org/.
3.1
essai de lixiviation
essai au cours duquel un matériau est mis en contact avec un lixiviant (3.2) dans des conditions
strictement définies et durant lequel certaines des substances du matériau sont extraites
3.2
lixiviant
liquide utilisé lors d’un essai de lixiviation (3.1)
Note 1 à l'article: Pour les besoins du présent document, le lixiviant est spécifié en 5.1.
3.3
éluat
solution obtenue après un essai de lixiviation (3.1)
Note 1 à l'article: L’éluat est également appelé « lixiviat ».
3.4
rapport liquide/solide
rapport L/S
rapport entre le volume total de liquide (L, en litres), qui est en contact avec le matériau du sol au cours
de cette extraction, et la masse sèche de l’échantillon (S, en kg de matière sèche)
Note 1 à l'article: Le rapport L/S est exprimé en l/kg.
3.5
taux de matière sèche
teneur en matière sèche
w
ms
rapport, exprimé en pourcentage, de la masse du résidu sec, déterminée conformément à l’ISO 11465,
sur la masse brute correspondante
2 © ISO 2019 – Tous droits réservés
3.6
taux d’humidité
teneur en eau
w
HO
rapport, exprimé en pourcentage, de la masse d’eau contenue dans le matériau tel qu’il est reçu sur la
masse sèche correspondante du matériau
Note 1 à l'article: Le calcul du taux d’humidité repose, dans le présent document, sur la masse du résidu sec,
comme spécifié dans l’ISO 11465 (pour la détermination de la teneur en eau du sol).
3.7
échantillon pour laboratoire
échantillon ou sous-échantillon(s) envoyé(s) au laboratoire ou reçu(s) par celui-ci
3.8
échantillon pour essai
échantillon préparé à partir de l’échantillon pour laboratoire (3.7) et duquel des prises d’essai (3.9) sont
prélevées pour essai ou analyse
3.9
prise d’essai
quantité de matériau de dimension appropriée pour la mesure de la concentration ou d’autres propriétés
pertinentes, prélevée sur l’échantillon pour essai (3.8)
Note 1 à l'article: La prise d’essai peut être prélevée directement sur l’échantillon pour laboratoire (3.7) si aucune
préparation de l’échantillon n’est requise, mais elle est généralement prélevée à partir de l’échantillon pour essai
préparé.
Note 2 à l'article: Une unité ou un incrément d’homogénéité, de dimension et de finesse appropriées, ne nécessitant
aucune préparation supplémentaire, peut constituer une prise d’essai.
3.10
matériau analogue au sol
ensemble des terres excavées, des matériaux de dragage, des sols artificiels, des sols traités et des
[7]
matériaux de remblai
4 Principe
La prise d’essai qui, soit d’origine, soit après un prétraitement, a une granulométrie inférieure ou égale
à 2 mm, est mise en contact avec une eau à faible concentration en chlorure de calcium (0,001 mol/l)
ou avec de l’eau déminéralisée (5.1), dans des conditions spécifiées. La présente méthode repose sur
l’hypothèse que l’équilibre ou le quasi-équilibre est atteint entre les phases liquide et solide pendant
la durée de l’essai. Le résidu solide est ensuite séparé du liquide. Le mode opératoire de séparation
peut fortement influencer les résultats d’essai et il doit être particulièrement strict pour les substances
organiques. Les propriétés des éluats sont mesurées au moyen de méthodes conçues pour l’analyse de
l’eau et adaptées afin de satisfaire aux critères d’analyse des éluats. L’éluat peut également être utilisé
lors d’essais d’écotoxicité ultérieurs.
Après l’essai, les conditions de lixiviation imposées par le matériau en termes de pH, de conductivité
électrique et, éventuellement, de COD, de potentiel redox ou de turbidité, doivent être enregistrées.
NOTE 1 Le comportement à la lixiviation du sol et des matériaux analogues au sol est souvent fonction de ces
paramètres. Ces derniers jouent donc un rôle important dans l’évaluation des résultats d’essai. En particulier, le
COD est important dans le sol et les matériaux analogues au sol pour bon nombre de substances inorganiques et
organiques.
NOTE 2 Le lixiviant est à 0,001 mol/l de CaCl pour réduire la mobilisation du COD due à une trop faible force
ionique du lixiviant.
Le mode opératoire décrit dans le présent document est fondé sur les exigences d’essai les plus strictes
pour déterminer le relargage des substances organiques et pour les essais d’écotoxicité ultérieurs.
Lorsque la mesure ne porte que sur le relargage des substances inorganiques, des exigences moins
strictes peuvent être adoptées pour certaines étapes du mode opératoire.
5 Réactifs
5.1 Eau déminéralisée, eau déionisée ou eau d’une pureté équivalente (5 < pH < 7,5), avec une
conductivité < 0,5 mS/m conformément à la qualité 3 spécifiée dans l’ISO 3696, amenée à 0,001 mol/l
de CaCl .
5.2 Chlorure de calcium (CaCl · 2 H O), de qualité analytique.
2 2
5.3 Azoture de sodium (NaN ), de qualité analytique.
5.4 Acide nitrique (HNO ), de qualité analytique, appliqué en solution de rinçage à 0,1 mol/l.
5.5 Solvant organique (acétone, de qualité analytique) pour le rinçage et le nettoyage
6 Appareillage
6.1 Verre borosilicaté, d’une grande pureté conformément à l’ISO 5667-3, possédant un volume
nominal de 1 l, les flacons en verre étant munis de bouchons en matériau inerte, par exemple en
PTFE (polytétrafluoroéthylène). Le rinçage est impératif et il convient de s’assurer que les flacons
précédemment utilisés ne présentent aucun niveau de fond d’analytes.
NOTE 1 Si seuls des paramètres inorganiques sont analysés, d’autres matériaux peuvent être utilisés pour les
flacons, comme le PEHD/PP, excepté pour les échantillons non préservés servant à l’analyse du mercure.
NOTE 2 Pour empêcher la dégradation des composés organiques sous l’effet de la lumière, conserver le
produit à l’abri de la lumière, utiliser un flacon en verre ambré, ou entourer le matériel de lixiviation d’une feuille
d’aluminium.
S’il est nécessaire d’analyser le bore, n’importe quel flacon en plastique, par exemple en PTFE
(polytétrafluoroéthylène), peut être employé.
Le volume de 1 l est choisi en fonction de la masse m de 100 g, comme spécifié en 7.4, afin de réduire
S
au minimum l’espace libre dans le flacon à un rapport L/S de 10 l/kg de matière sèche. Dans le cas des
matériaux de faible densité, il peut s’avérer nécessaire de s’écarter de cette exigence tout en essayant de
réduire au minimum l’espace libre. Cet écart doit être mentionné.
NOTE 3 Un verre de haute qualité est jugé adéquat pour les substances métalliques et organiques, en
particulier du fait que la plage de pH normalement couverte durant l’essai du sol n’atteint pas les conditions
(pH > 10 et pH < 3) dans lesquelles le verre lui-même est attaqué. Pour les essais d’écotoxicité, des éluats avec à la
fois des substances inorganiques et organiques sont nécessaires, ce qui renforce le besoin de générer des éluats
intégrés.
NOTE 4 Un traitement thermique à 550 °C de la verrerie utilisée peut être appliqué pour éliminer les traces
d’analytes. Ce traitement a cependant montré qu’il favorise l’augmentation de l’adsorption des substances
organiques de l’air.
6.2 Flacon en verre, de grande qualité (conforme aux exigences de 6.1), possédant un volume
nominal de 5 l par exemple, à utiliser lorsque les échantillons de réplicats d’essais sont recombinés après
centrifugation pour analyse ou essais ultérieurs.
4 © ISO 2019 – Tous droits réservés
6.3 Agitateur à retournements (5 r/min à 10 r/min) ou table à rouleaux effectuant environ 10 r/min.
D’autres dispositifs d’agitation peuvent être utilisés, s’il est prouvé qu’ils peuvent fournir des résultats
équivalents. Les dispositifs d’agitation ci-dessus sont préconisés car il convient d’éviter toute abrasion
excessive risquant de réduire de manière significative la taille des particules.
6.4 Appareil de filtration, soit un dispositif de filtration sous vide (entre 2,5 kPa et 4,0 kPa), soit un
appareil de filtration sous pression (<0,5 MPa). Le rinçage est impératif. Lorsque des substances semi-
volatiles sont analysées, un appareil de filtration sous vide ne doit pas être utilisé.
6.5 Filtres à membrane, de 0,45 µm, pré-rincés ou nettoyés de manière similaire [par exemple,
rincés avec du HNO (5.2) à 0,1 mol/l puis à l’eau (5.1)] (uniquement pour l’analyse de substances
inorganiques).
Les filtres doivent être choisis de sorte qu’ils n’adsorbent (ou ne relarguent) pas les substances d’intérêt.
NOTE Cela peut faire l’objet d’un essai lors d’expérimentations préliminaires.
6.6 Filtres en fibres de verre, ayant un degré de séparation de 0,7 µm.
Les filtres doivent être choisis de sorte qu’ils n’adsorbent (ou ne relarguent) pas les substances d’intérêt.
NOTE Cela peut faire l’objet d’un essai lors d’expérimentations préliminaires.
6.7 Matériel de tamisage avec des tamis à mailles nominales de 2 mm.
NOTE En raison du tamisage, il peut se produire une contamination de l’échantillon atteignant un tel niveau
qu’elle modifie la lixiviation de certaines substances d’intérêt, par exemple le chrome, le nickel et le molybdène
des équipements en acier inoxydable ou les plastifiants des tamis en plastique.
6.8 Centrifugeuse fonctionnant de 20 000 g à 30 000 g, comportant des tubes à centrifuger en PFA
(perfluoroalcoxy), en FEP (éthylènepropylène fluoré), ou des tubes constitués d’un autre matériau, inerte
[8]
vis-à-vis des composés inorganiques et organiques et adapté à une centrifugation à grande vitesse .
NOTE L’éventuelle sorption de substances organiques hydrophobes sur les tubes à centrifuger peut faire
l’objet d’un essai lors d’expérimentations préliminaires.
En variante, si une centrifugeuse à grande vitesse n’est pas disponible, une centrifugeuse fonctionnant
de 2 000 g à 3 000 g et comportant des flacons en verre peut être utilisée en augmentant la durée de
centrifugation. Un refroidissement doit être appliqué pour maintenir la température souhaitée.
6.9 Dispositif de mesure de la conductivité électrique
6.10 pH-mètre, conforme à l’ISO 10523, d’une précision d’au moins ± 0,05 unités pH.
6.11 Thermomètre, pour mesurer la température de l’air.
6.12 Potentiomètre redox (facultatif).
6.13 Balance, d’une précision d’au moins 0,1 g.
6.14 Éprouvettes graduées, pour le dosage volumétrique, d’une précision de 1 %.
6.15 Diviseur d’échantillon, pour le quartage des échantillons pour laboratoire (facultatif).
6.16 Turbidimètre, comme spécifié dans l’ISO 7027-1.
6.17 Équipement de fragmentation, concasseur à mâchoires.
NOTE En raison du fractionnement granulométrique, il peut se produire une contamination de l’échantillon
atteignant un tel niveau qu’elle modifie la lixiviation de certaines substances d’intérêt, par exemple le chrome, le
nickel et le molybdène des équipements en acier inoxydable.
7 Prétraitement des échantillons
7.1 Préparation de l’échantillon pour laboratoire et spécification de la granulométrie
Un échantillon pour laboratoire représentatif d’au moins 2 kg (de matière sèche) est prélevé (par
[10-13]
exemple, comme indiqué dans l'ISO 18400-101, ISO 18400-104, ISO 18400-105, ISO 18400-202 et
[14]
dans l’ISO 23909 ) et doit être conservé à basse température (4 °C) dans des emballages scellés, afin
[12]
d’éviter toute altération indésirable du matériau (voir par exemple l’ISO 18400-105 ).
L’essai doit être réalisé sur un sol ou un matériau analogue au sol de granulométrie < 2 mm obtenu par
[9]
tamisage (par exemple, comme indiqué dans l’ISO 11464 ). Les matériaux de fraction granulométrique
supérieure d’origine naturelle dans l’échantillon doivent être triés et éliminés. Le type ainsi que
la quantité des matériaux écartés doivent être enregistrés. En présence de matériaux de fraction
granulométrique supérieure d’origine anthropique, et si ceux-ci sont présumés contenir des substances
d’intérêt, cette partie peut faire l’objet d’autres formes de préparation d’échantillon et d’essai.
Si l’échantillon pour laboratoire ne peut pas être homogénéisé ou tamisé en raison de son taux
[9]
d’humidité, il est permis, dans ce cas uniquement, de le sécher (conformément à l’ISO 11464 ). La
température de séchage ne doit pas dépasser 30 °C.
NOTE 1 Le tamisage et le séchage à une température de plus de 30 °C, ainsi que le concassage, peuvent
engendrer des pertes de certaines substances semi-volatiles (inorganiques et organiques) et altérer les
caractéristiques de lixiviation (se reporter à A.3.6).
NOTE 2 En raison du tamisage, il peut se produire une contamination de l’échantillon atteignant un tel
niveau qu’elle modifie la lixiviation de certaines substances intéressantes, par exemple le chrome, le nickel et le
molybdène des équipements en acier inoxydable ou les plastifiants des tamis en plastique.
NOTE 3 En raison du tamisage, il peut se produire une contamination de l’échantillon atteignant un tel
niveau qu’elle modifie la lixiviation de certaines substances intéressantes, par exemple le chrome, le nickel et le
molybdène des équipements en acier inoxydable ou les plastifiants des tamis en plastique.
7.2 Préparation de l’échantillon pour essai
Utiliser un diviseur d’échantillon (6.15) ou recourir au quartage pour diviser l’échantillon pour
laboratoire et obtenir un échantillon pour essai. La taille de l’échantillon pour essai requise est fonction
du volume d’éluat nécessaire à l’objectif spécifique visé et de l’analyse chimique et/ou des essais
écotoxicologiques ultérieurs à réaliser sur l’éluat.
NOTE 1 Des volumes plus importants d’éluat peuvent être produits en associant les éluats de réplicats
d’essais après centrifugation (ou filtration), si cela se révèle nécessaire pour l’analyse chimique ou les essais
écotoxicologiques. En variante, des volumes plus importants d’éluat peuvent également être produits en un seul
essai, sous réserve de conserver les rapports en termes de L/S et d’espace libre minimal.
NOTE 2 La quantité requise des échantillons pour essai est fonction de la distribution granulométrique du
[14]
sol à analyser (voir l’ISO 23909 ). La quantité d’échantillon spécifiée sera généralement appropriée. Pour
des cas spécifiques, une quantité d’échantillon plus petite peut être acceptée si, par exemple, pour des raisons
spécifiques une quantité inférieure de matériau est disponible, dans la mesure où la réalisation de l’essai peut se
dérouler comme spécifié en 7.2 à 7.4.
7.3 Détermination du taux de matière sèche et du taux d’humidité
L’ensemble de l’échantillon pour essai, en conformité avec le critère de taille du 7.1, ne doit plus être
séché. Le taux d’humidité de l’échantillon pour essai doit être déterminé sur une prise d’essai séparée,
6 © ISO 2019 – Tous droits réservés
à une température de (105 ± 5) °C. Si, avant les essais, l’échantillon de sol est séché à l’air, le taux de
matière sèche w de l’échantillon séché à l’air doit également être déterminé. Il doit être pris en
ms
compte lors de l’ajustement du rapport L/S. La masse sèche de l’échantillon doit être déterminée à une
température de (105 ± 5) °C conformément à l’ISO 11465 et le taux de matière sèche est calculé suivant
la Formule (1):
wm=×100 /m (1)
ms SH
où
w est le taux de matière sèche, exprimé en pourcentage (%);
ms
m est la masse de l’échantillon séché, exprimée en kilogrammes (kg);
S
m est la masse de l’échantillon non séché, exprimée en kilogrammes (kg).
H
Le taux d’humidité ( w en %) est calculé conformément à la Formule (2):
HO
wm=×100 −mm/ (2)
()
HO HS S
NOTE Si des composés volatils ou instables sont présents dans l’échantillon de sol, cette méthode
gravimétrique ne peut pas être utilisée pour la détermination précise du taux d’humidité.
Si, pour les raisons exposées en 7.1, le matériau a été (partiellement) séché avant la division de
l’échantillon, la perte de masse totale doit être prise en considération.
7.4 Préparation de la prise d’essai
À partir de l’échantillon pour essai, préparer une prise d’essai d’une masse totale m de
(100 ± 5) g(mesurée avec une précision de 0,1 g (6.13) de matière sèche (m ) selon la Formule (3):
S
mm=×100 /w (3)
Sms
Utiliser un diviseur d’échantillon (6.15) ou recourir au quartage pour diviser l’échantillon.
NOTE La division ou le quartage d’échantillon peut donner lieu à une perte des substances semi-volatiles
(inorganiques et organiques).
Compte tenu des exigences minimales relatives au volume d’éluat pour les analyses, il peut se révéler
nécessaire d’utiliser une prise d’essai plus importante et, par conséquent, un volume de lixiviant plus
important. Cet écart par rapport au présent document doit être spécifié dans le rapport d’essai.
Dans le cas d’un échantillon séché à l’air, utiliser w à la place de w pour déterminer la masse de
ms,SA ms
l’échantillon de la prise d’essai.
8 Mode opératoire
8.1 Température
L’essai de conformité pour la lixiviation doit être réalisé à une température ambiante de (22 ± 3) °C.
Pour les matériaux très sensibles à la dégradation biologique, la réalisation des essais à une faible
température (par exemple 4 °C) et en évitant toute exposition directe à la lumière, réduira de manière
significative l’activité biologique. La baisse de la température peut entraîner un relargage plus faible/
plus lent des substances organiques, et ainsi des concentrations plus faibles de ces composés dans les
lixiviats. Si l’essai est modifié de cette manière, cet écart doit être signalé dans le rapport d’essai.
8.2 Description du mode opératoire
8.2.1 Préparation de l’éluant
Préparer une solution de CaCl 0,001 M en dissolvant 0,147 g de CaCl dans de l’eau puis en complétant
2 2
à 1 000 ml.
Dans certains cas particuliers (à savoir, quantification du Ca et/ou des chlorures dans l’éluat ou
échantillon de salinité élevée), il est également possible d’utiliser de l’eau sans ajout de CaCl . Le type de
lixiviant utilisé doit être mentionné dans le rapport d’essai.
NOTE 1 Pour certains types de sols (notamment ceux présentant une forte teneur en matière organique),
l’emploi d’eau déminéralisée comme lixiviant peut aboutir à un éluat de plus forte turbidité et de plus faible force
ionique et engendrer une plus forte adsorption des analytes sur les colloïdes.
NOTE 2 Pour les éluats qui ne sont pas utilisés pour les essais d’écotoxicité, de l’azoture de sodium (NaN )
peut être ajouté à une concentration résultante de 0,1 % afin de limiter la dégradation microbienne des
substances organiques. Toutefois, l’ajout de NaN ne permet de réduire la biodégradation que s’il est ajouté en
très grande quantité dans le lixiviant, mais cette forte concentration du lixiviant en NaN est hautement toxique.
En conséquence, d’autres mesures appropriées peuvent être envisagées pour éviter/limiter la biodégradation de
l’échantillon ou de l’éluat recueilli (par exemple, exposition de l’échantillon à un rayonnement γ, stockage dans un
local climatisé et sombre, raccourcissement de la durée de recueil de l’éluat, etc.). Lorsque la mesure ne porte que
sur des composés inorganiques, il n’est pas approprié d’ajouter du NaN .
8.2.2 Étape de lixiviation
Placer la prise d’essai d’une masse totale m de (100 ± 5) g de matière sèche m dans un flacon (6.1).
S
Selon la distribution granulométrique, il est possible d’employer une prise d’essai de masse plus
importante pour garantir la représentativité de cette prise d’essai (voir 7.1).
Au moyen d’une balance (6.13) ou d’une éprouvette graduée (6.14), ajouter une quantité de lixiviant (V )
L
permettant d’obtenir un rapport liquide/solide (L/S) de (10 ± 0,2) l/kg au cours de l’extraction, selon la
Formule (4). Il faut veiller à ce que le solide et le liquide se mélangent bien:
Vw=−10 / ρ ×100 ×m (4)
()
LH OH OS
où
V est le volume de lixiviant utilisé (l);
L
m est la masse sèche de la prise d’essai (en kg);
S
est la masse volumique de l’eau (généralement prise égale à 1 kg/l);
ρ
HO
est le taux d’humidité de la prise d’essai (en %).
w
HO
Placer le flacon fermé dans un dispositif d’agitation (6.3). Agiter pendant (24 ± 0,5) h.
En option, il est possible d’adopter un temps d’agitation de 6 h au lieu de 24 h lorsqu’il peut être démontré
que l’équilibre ou le quasi-équilibre est atteint ou lorsque, à des fins de contrôle qualité, un temps de
retour rapide est requis. Dans ce cas, le rapport doit mentionner que la lixiviation a été réalisée en 6 h.
La décantation des solides dans le flacon au cours de l’agitation doit être évitée. À la fin de la période
d’agitation, le flacon est retiré du dispositif d’agitation.
8.2.3 Étape de séparation liquide/solide
Laisser les solides en suspension décanter pendant (15 ± 5) min.
8 © ISO 2019 – Tous droits réservés
Transférer le liquide surnageant dans les tubes à centrifuger (6.8). Le récipient de centrifugation doit
être choisi de façon qu’il n’adsorbe pas (et ne relargue pas) les analytes.
Il existe deux options pour la centrifugation:
a) centrifuger l’éluat pendant 30 min de 20 000 g à 30 000 g au moyen d’une centrifugeuse à grande
vitesse (6.8, voir également l’Annexe C);
b) centrifuger l’éluat pendant 5 h de 2 000 g à 3 000 g dans des flacons en verre au moyen d’une
centrifugeuse à faible vitesse (6.8).
Un refroidissement doit être appliqué pour maintenir la température à (22 ± 3) °C (voir 8.1).
NOTE 1 Selon la loi de Stoke, les résultats des deux méthodes de centrifugation sont censés être comparables.
Il est possible d’appliquer d’autres combinaisons de vitesse et de durée de centrifugation qui aboutiront à
des conditions de centrifugation comparables, sous réserve qu’elles soient définies par calcul à partir des
caractéristiques techniques du rotor (voir les recommandations de l’Annexe C).
Le ralentissement de la centrifugeuse doit être réalisé progressivement afin d’éviter toute remise en
suspension. La durée de décélération ne doit pas excéder 20 min.
NOTE 2 Si, après la centrifugation, des matières sont toujours en suspension du fait de leur légèreté (cas des
particules carbonifères, par exemple), il est possible de réaliser une filtration sur fibres de verre (6.6) pour
éliminer ces particules ou réduire la turbidité.
Après la centrifugation, l’éluat doit être immédiatement transféré dans un récipient approprié pour
mesure du pH et du potentiel redox (voir également l’avant-dernier alinéa en 8.2.2), puis conservé pour
analyse chimique et/ou essais écotoxicologiques ultérieurs. En général, cet éluat peut aussi bien être
utilisé pour l’analyse des substances inorganiques que pour l’analyse des substances organiques.
Lorsque la mesure ne porte que sur les substances inorganiques, l’étape de la centrifugation peut être
omise, et l’éluat obtenu après décantation peut être directement filtré au moyen des filtres à membrane
appropriés (6.5) et d’un dispositif de filtration sous vide ou sous pression (6.4), (voir l’Annexe B pour
consulter un exemple). Lorsque la filtration comme spécifié est impossible à réaliser avec un débit
du liquide d’au moins 30 ml/cm /h en moins de 1 h, un mode opératoire de séparation liquide/solide,
spécifique à ce cas, doit être appliqué et consigné de manière détaillée dans le rapport d’essai. Ce mode
opératoire spécifique doit exclure l’utilisation d’additifs.
NOTE 3 Pour les substances inorganiques, il est souvent préférable de procéder, avant la filtration, à une
centrifugation préalable de l’éluat de 2 000 g à 3 000 g pendant 20 min au moyen de flacons en verre munis de
bouchons à vis et d’un revêtement interne en polytétrafluoroéthylène (ou, si possible, en utilisant directement
des flacons de lixiviation). Il est également possible d’utiliser une vitesse de centrifugation plus élevée ou une
durée de centrifugation plus importante (voir l’Annexe C).
NOTE 4 Un tel mode opératoire de séparation liquide/solide spécifique peut inclure la décantation, la
préfiltration avec un filtre plus grossier, la centrifugation, la filtration avec un filtre possédant une taille de
membrane importante, la filtration sous
...