ISO 12468-1:2013
(Main)External exposure of roofs to fire - Part 1: Test method
External exposure of roofs to fire - Part 1: Test method
ISO 12468-1:2013 specifies a test method to determine the resistance of roofs to external exposure to fire. This method evaluates the behaviour of the roof when exposed to three types of burning brands combined with wind and with or without heat radiation, concerning the fire spread across the external surface of the roof, the fire spread within the roof, the fire penetration, and the production of flaming droplets or debris falling through the roof, from the underside of the roof, or from the exposed surface.
Exposition des toitures à un feu extérieur — Partie 1: Méthode d'essais
General Information
- Status
- Published
- Publication Date
- 15-Oct-2013
- Technical Committee
- ISO/TC 92/SC 2 - Fire containment
- Drafting Committee
- ISO/TC 92/SC 2 - Fire containment
- Current Stage
- 9060 - Close of review
- Completion Date
- 04-Mar-2030
Relations
- Effective Date
- 06-Jun-2022
- Effective Date
- 19-Jun-2011
Overview
ISO 12468-1:2013 - External exposure of roofs to fire: Part 1: Test method defines a standardized laboratory method to assess how roof systems behave when exposed to external fires. The test simulates burning brands (embers) combined with wind and, for the most severe exposure, additional radiant heat. It measures external fire spread, fire spread within the roof, fire penetration, and the production of flaming droplets or debris.
Keywords: ISO 12468-1:2013, external exposure of roofs to fire, roof fire testing, burning brands, fire penetration
Key technical topics and requirements
- Exposure levels: Three fire exposure levels are defined:
- Level A - large burning brand from adjacent building; considers wind and additional radiant heat.
- Level B - medium burning brand from neighbourhood fire; considers wind only.
- Level C - small burning brand transported by wind from remote fire; considers wind only.
- Measured outcomes:
- External fire spread across the exposed surface
- Fire spread within the roof layers
- Fire penetration (openings, sustained underside flaming, or flaming debris)
- Production of flaming droplets or debris that continue to burn for ≥5 s
- Specimen requirements:
- Representative roof sections required; two specimens per exposure level.
- Standard specimen size: 1 200 mm ± 10 mm (width) × 2 000 mm ± 10 mm (length) for each test pitch (larger specimens allowed if necessary).
- Pitch selection rules: <5° test at 0°; 5°–20° test at 15°; >20° test at 30°.
- Test apparatus and controls: Includes burning-brand sources, wind generation, optional radiant panel, calibration elements, specimen holder and timing devices. The standard specifies conditioning, edge protection, ignition procedure, timing and post-test examination.
- Safety: The document highlights the hazards of fire testing (toxic smoke, operational risks) and requires risk assessment, written safety instructions, and trained personnel.
Practical applications and users
ISO 12468-1:2013 is used to:
- Certify and classify roof coverings and roof systems for resistance to ember attack and external fires.
- Inform design decisions for fire-safe roofing materials and assemblies.
- Support regulatory compliance, product standards, and building code references.
- Provide test data for manufacturers, fire test laboratories, fire safety engineers, building inspectors, specifiers, insurers and risk assessors.
Keywords: roof fire resistance testing, ember attack, roof system classification
Related standards
- ISO 12468-2: Classification of roofs (companion document)
- ISO 12468-3: Commentary (guidance)
- ISO 13943: Fire safety - Vocabulary (referenced terminology)
This standard provides a reproducible, laboratory-based method to evaluate how roofs respond to external fire exposures and produces test evidence used in product development, certification and regulatory assessment.
Frequently Asked Questions
ISO 12468-1:2013 is a standard published by the International Organization for Standardization (ISO). Its full title is "External exposure of roofs to fire - Part 1: Test method". This standard covers: ISO 12468-1:2013 specifies a test method to determine the resistance of roofs to external exposure to fire. This method evaluates the behaviour of the roof when exposed to three types of burning brands combined with wind and with or without heat radiation, concerning the fire spread across the external surface of the roof, the fire spread within the roof, the fire penetration, and the production of flaming droplets or debris falling through the roof, from the underside of the roof, or from the exposed surface.
ISO 12468-1:2013 specifies a test method to determine the resistance of roofs to external exposure to fire. This method evaluates the behaviour of the roof when exposed to three types of burning brands combined with wind and with or without heat radiation, concerning the fire spread across the external surface of the roof, the fire spread within the roof, the fire penetration, and the production of flaming droplets or debris falling through the roof, from the underside of the roof, or from the exposed surface.
ISO 12468-1:2013 is classified under the following ICS (International Classification for Standards) categories: 13.220.50 - Fire-resistance of building materials and elements; 91.060.20 - Roofs. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 12468-1:2013 has the following relationships with other standards: It is inter standard links to ISO 21268-2:2019, ISO 12468-1:2003. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase ISO 12468-1:2013 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 12468-1
Second edition
2013-11-01
External exposure of roofs to fire —
Part 1:
Test method
Exposition des toitures à un feu extérieur —
Partie 1: Méthode d’essais
Reference number
©
ISO 2013
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 3
5 Selection of test specimen pitch . 3
6 Test specimens. 3
6.1 General requirements . 3
6.2 Selection of standard supporting elements . 5
6.3 Positioning of joints . 6
6.4 Edge detailing . 7
7 Test equipment. 7
7.1 Exposure levels . 7
7.2 Brands . 8
7.3 Wind .10
7.4 Radiation .11
7.5 Timing device .11
7.6 Calibration element.11
7.7 Specimen holder .11
7.8 Gas burner . .15
7.9 Stand .17
8 Test conditions .17
8.1 Test environment .17
8.2 Calibration procedure .18
9 Conditioning and test preparation .18
9.1 Conditioning .18
9.2 Protection of the edges .19
10 Test procedure .19
10.1 General .19
10.2 Commencement of the test .19
10.3 Ignition and positioning of the brands .20
10.4 End of the test .21
10.5 Post-test examination .21
11 Observations and measurements .21
11.1 General .21
11.2 External fire spread .21
11.3 Fire penetration .21
11.4 Opening .21
11.5 Damage .22
12 Expression of test results.22
13 Test report .22
Annex A (normative) Direct field of application .24
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical Barriers
to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 92, Fire Safety, Subcommittee SC 2, Fire Containment.
This second edition cancels and replaces the first edition (ISO 12468–1:2003), of which it constitutes a
minor revision.
ISO 12468 consists of the following parts, under the general title External exposure of roofs to fire:
— Part 1: Test method
— Part 2: Classification of roofs
— Part 3: Commentary
iv © ISO 2013 – All rights reserved
Introduction
This part of ISO 12468 specifies a test method that relates to the effects of fires on roofs. The test method
described in this part of ISO 12468 represents the effect of three levels of fire exposure.
— Level A: A large burning brand coming from an adjacent building and falling onto the roof. Level A
considers the effects of wind and additional radiant heat.
— Level B: A medium burning brand coming from a fire in a neighbourhood and falling onto the roof.
Level B considers the effect of wind but without additional radiant heat.
— Level C: A small burning brand transported by the wind from a remote fire and falling onto the roof.
Level C considers the effect of wind but without additional radiant heat.
INTERNATIONAL STANDARD ISO 12468-1:2013(E)
External exposure of roofs to fire —
Part 1:
Test method
1 Scope
CAUTION — The attention of all persons concerned with managing and carrying out this fire test
is drawn to the fact that fire testing may be hazardous and that there is a possibility that toxic
and/or harmful smoke and gases may be evolved during the test. Mechanical and operational
hazards may also arise during the construction of the test elements or structures, their testing,
and disposal of test residues. An assessment of all potential hazards and risks to health shall be
made and safety precautions shall be identified and provided. Written safety instructions shall
be issued. Appropriate training shall be given to relevant personnel. Laboratory personnel shall
ensure that they follow written safety instructions at all times.
This part of ISO 12468 specifies a test method to determine the resistance of roofs to external exposure
to fire. This method evaluates the behaviour of the roof when exposed to three types of burning brands
combined with wind and with or without heat radiation, concerning
a) the fire spread across the external surface of the roof,
b) the fire spread within the roof,
c) the fire penetration, and
d) the production of flaming droplets or debris falling through the roof, from the underside of the roof,
or from the exposed surface.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 13943, Fire safety — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 13943 and the following apply.
3.1
assembly
fabrication of materials and/or composites
EXAMPLE Sandwich panels.
3.2
burned material
material that has been destroyed by combustion or pyrolysis
3.3
composite
combination of materials which are generally recognized in building construction as discrete entities
EXAMPLE Coated or laminated product such as roofing felt.
3.4
continuous deck
deck supporting the roof covering in which the gap between adjacent elements is not greater than
0,5 mm (5,0 mm in the case of wooden planks with plain edges)
3.5
damaged material
material that has been burned, melted, or otherwise visually changed by heat but does not include
discoloration and soot deposits
3.6
exposed surface
external surface of the calibration element or of the specimen which is subject to the heat conditions
3.7
external fire spread
progression and extent of sustained flaming across the exposed surface of the specimen
3.8
fire penetration
any opening, sustained flaming, or glowing due to combustion on the underside that appears during the test
and/or the occurrence of any flaming droplets or debris falling through the specimen or from the underside
Note 1 to entry: Charring or discoloration is not to be regarded as fire penetration.
3.9
fire spread within the roof
extent of burned material in each functional layer inside the specimen
3.10
flaming droplets or debris
burning material falling from or through the specimen that continues to burn on the floor for at least 5 s
3.11
internal damage
extent of damaged material in each functional layer inside the specimen
3.12
material
basic single substance or a uniformly dispersed mixture of substances
EXAMPLE Metal, stone, wood, bitumen, concrete, or mineral wool.
3.13
measuring zone
area of the specimen within which measurements are made
3.14
opening
any hole greater than 10 mm × 10 mm that appears during the test which penetrates completely
through the specimen
3.15
product
material (3.12), composite (3.3), or assembly (3.1) about which information is required
2 © ISO 2013 – All rights reserved
3.16
profile pitch
repeating length between sections of a uniformly corrugated or undulating roof deck
3.17
roof system
covering and sealing systems including any insulating layers or vapour barriers with their supporting
elements and roof lights or other closures for roof apertures that are intended to provide a
weatherproof surface
Note 1 to entry: Elements with a slope greater than 70° are not considered as roofs in this part of ISO 12468.
3.18
roof covering
material (3.12) attached to the deck
3.19
specimen
representative section of the roof system prepared for the purpose of test
3.20
sustained flaming
flaming arising from an observed location, which persists for 5 s or longer
3.21
underside
bottom surface of the specimen
4 Symbols
Symbol Description Unit
v , v , v , v , v , v v Velocity of the air at the measuring points metres per second (m/s)
1 2 3 4 5 6, 7
α Pitch (slope) degrees (°)
5 Selection of test specimen pitch
Roof systems designed for only one pitch shall be tested at the actual design pitch.
Roof systems designed for more than one pitch shall be tested as follows:
a) for pitch (α) less than 5°, test at zero pitch;
b) for pitch (α) from 5° to 20°, test at 15°;
c) for pitch (α) greater than 20°, test at 30°.
6 Test specimens
6.1 General requirements
For each level of fire exposure, two specimens shall be tested with dimensions measuring
1 200 mm ± 10 mm in width × 2 000 mm ± 10 mm in length for each test pitch. (See Figures 1 and 2.)
When this is not possible due to the size of the roof light or other closure, a larger specimen shall be used.
NOTE Roof lights cause difficulties due to their size, shape, composition, and fire behaviour. Further guidance
on the testing of roof lights will be presented in the next revision of this part of ISO 12468.
The specimens shall be representative in all details of the roof in practice.
Dimensions in millimetres with tolerances of ±10 mm
Key
1 radiant panel position
2 A brands
3 measuring zone
Figure 1 — Measuring zone and position of brands for Level A
4 © ISO 2013 – All rights reserved
Key
1 measuring zone
2 B brands or C brands
Figure 2 — Measuring zone and position of the brands for Level B or Level C
6.2 Selection of standard supporting elements
6.2.1 For continuous decks
6.2.1.1 General
The test deck shall be selected in accordance with the following:
a) In the case of roof coverings intended to be installed over a continuous deck other than a profiled
metal deck, a roof deck in accordance with 6.2.1.2 or 6.2.1.4 shall be used;
b) If the materials will only be laid over a profiled metal deck, then a trapezoidal profiled metal deck,
in accordance with 6.2.1.3, shall be used as the deck.
6.2.1.2 Wood particleboard decks
6.2.1.2.1 The wood particleboard shall consist of wood particles bonded with polymer adhesive (e.g.
3 3
urea formaldehyde). This particleboard shall have a density of 680 kg/m ± 50 kg/m and shall not be
treated with fire retardants.
6.2.1.2.2 A wood particleboard deck shall be constructed from planks 250 mm wide × 13 mm ± 1 mm
thick running parallel to the eaves with plain edges and tightly butt jointed so that the gaps between
planks do not exceed 0,5 mm.
6.2.1.2.3 If it is intended also to cover the case of decks made from wooden planks with plain edges,
then these gaps shall be 5 mm ± 0,5 mm.
6.2.1.3 Metal decks
The trapezoidal profiled metal deck shall be made of aluminium or steel (subject to the expected field of
application) and have the width of the crown approximately equal to 50 % of the profile pitch and a trough
depth of approximately 100 mm. The corrugations shall run parallel to the eaves and be open at the ends.
6.2.1.4 Other non-combustible decks
If roofing materials are intended to be laid only on continuous, non-combustible decks with a minimum
thickness of 10 mm, then the test roof deck shall consist of 12 mm ± 2 mm thick reinforced calcium
3 3
silicate board (oven dry density 900 kg/m ± 100 kg/m ).
6.2.2 For non-continuous decks
The spacing of roof supports of any type shall be in accordance with the maximum permissible spans
proposed by the manufacturer for the particular application but not exceeding the minimum dimensions
specified for the specimen in 6.1.
6.3 Positioning of joints
6.3.1 General
The joints shall be representative of practical application. In the case of overlapping layers, the position
of the joints shall be considered to be the edge of the upper layer.
6.3.2 Description of specimen types with respect to joints
Where the dimensions of the elements of any of the layers are such that it requires more than four pieces
to cover the specimen, or if any of the layers are without joints, then the specimens shall be fabricated
such that those layers are representative of actual field practice (see Figures 3 and 4).
Specimens are categorized by the following types:
— Type 1: Single central vertical joint in the top layer. Single horizontal joint in the top layer under
position of the left brand. Single vertical joint in layer next to top layer under position of the right
brand. Single vertical joint in insulation under position of the left brand [see Figure 4 a), Type 1];
— Type 2: Single vertical joint in the top layer under position of the right brand. Single vertical joint in
layer next to insulation under position of the left brand [see Figure 4 b), Type 2];
6 © ISO 2013 – All rights reserved
— Type 3: One cross joint of the top layer under position of the right brand and, where possible
according to the design of the product, a vertical joint in layer under top under the left brand [see
Figure 4 c), Type 3];
— Type 4: Centre of one element of the top layer and, where possible according to the design of the
product, a vertical joint of supporting deck, under position of the right brand and in insulation under
the left brand [see Figure 4 d), Type 4].
6.3.3 Selection of the specimen types
Either specimen types, Types 1 and 2 or Types 3 and 4, shall be used for each test pitch and for each level
of fire exposure.
6.4 Edge detailing
No special measures shall be taken by the sponsor to protect the edges of the specimen.
Key
1 vertical joint in top layer 6 vertical joint in supporting deck
2 horizontal joint in top layer 7 weathering layer
3 joint in layer next to insulation 8 insulation
4 joint in layer next to top layer 9 roof deck
5 joint in insulation
Figure 3 — Identification of joints in a multilayer roof
7 Test equipment
7.1 Exposure levels
Three levels are defined:
a) Level A consists of Brand A combined with wind and additional radiant heat;
b) Level B consists of Brand B combined with wind and without any additional radiant heat;
c) Level C consists of Brand C combined with wind and without any additional radiant heat.
The wind is identical for the Levels A, B, and C. The measuring zone, position of the brands, and position
of the radiant panel are shown in Figures 1 and 2.
a) Type 1 b) Type 2
c) Type 3 d) Type 4
Key
1 vertical joint in top layer 4 joint in layer next to top layer
2 horizontal joint in top layer 5 joint in insulation
3 joint in layer next to insulation 6 vertical joint in supporting deck
Figure 4 — Position of joints and types of specimens
7.2 Brands
7.2.1 General
Two brands are utilized for each specimen. The test brands shall be constructed from Beech (Fagus
3 3
salvatica or Fagus grandifolia) having an ove
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...