Plastics piping systems for pressure and non-pressure drainage and sewerage — Glass-reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin — Amendment 1

Systèmes de canalisation en matières plastiques pour les branchements et les collecteurs d'assainissement avec ou sans pression — Systèmes en plastiques thermodurcissables renforcés de verre (PRV) à base de résine de polyester non saturé (UP) — Amendement 1

General Information

Status
Withdrawn
Publication Date
01-Mar-2012
Withdrawal Date
01-Mar-2012
Current Stage
9599 - Withdrawal of International Standard
Completion Date
17-May-2018
Ref Project

Relations

Buy Standard

Standard
ISO 10467:2004/Amd 1:2012
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 10467
First edition
2004-02-01
AMENDMENT 1
2012-03-01
Plastics piping systems for pressure and
non-pressure drainage and sewerage —
Glass-reinforced thermosetting plastics
(GRP) systems based on unsaturated
polyester (UP) resin
AMENDMENT 1
Systèmes de canalisation en matières plastiques pour les
branchements et les collecteurs d’assainissement avec ou sans
pression — Systèmes en plastiques thermodurcissables renforcés de
verre (PRV) à base de résine de polyester non saturé (UP)
AMENDEMENT 1
Reference number
ISO 10467:2004/Amd.1:2012(E)
©
ISO 2012

---------------------- Page: 1 ----------------------
ISO 10467:2004/Amd.1:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 10467:2004/Amd.1:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
Amendment 1 to ISO 10467:2004 was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and
valves for the transport of fluids, Subcommittee SC 6, Reinforced plastics pipes and fittings for all applications.
© ISO 2012 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 10467:2004/Amd.1:2012(E)
Plastics piping systems for pressure and non-pressure drainage
and sewerage — Glass-reinforced thermosetting plastics (GRP)
systems based on unsaturated polyester (UP) resin
AMENDMENT 1
Page 1, Scope
Add the following Note after the first paragraph:
NOTE 1 For the purpose of this International Standard, the term polyester resin also includes vinyl-ester resins.
Page 1, Scope
Add 2 to the Note following the second paragraph:
NOTE 2 Piping systems conforming to this International Standard can also be used for non-buried applications
provided the influence of the environment and the supports are considered in the design of the pipes, fittings and joints.
Page 2, Normative references
Correct the following normative references from dated to undated normative references:
ISO 75-2, Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite
ISO 7432, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Test methods to prove the
design of locked socket-and-spigot joints, including double-socket joints, with elastomeric seals
ISO 7511, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes and fittings —
Test methods to prove the leaktightness of the wall under short-term internal pressure
ISO 8483, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Test methods to prove the
design of bolted flange joints
ISO 8513, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes — Determination
of longitudinal tensile properties
ISO 8521, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes — Test methods
for the determination of the apparent initial circumferential tensile strength
ISO 8533, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Test methods to prove the
design of cemented or wrapped joints
ISO 8639, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Test methods for
leaktightness of flexible joints
ISO 10928, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes and fittings —
Methods for regression analysis and their use
Page 17, 4.5.1
Add the following new sentence to the end of the first paragraph:
For routine quality control testing, any measurements shall be taken at the prevailing temperature or, if the
manufacturer requires, at the temperature specified in this clause.
© ISO 2012 – All rights reserved 1

---------------------- Page: 4 ----------------------
ISO 10467:2004/Amd.1:2012(E)
Page 20, Table 4
Replace Table 4, in which some of the range of declared pipe internal diameters have been corrected, with
the following:
Table 4 — Series A — Specified pipe internal diameters and tolerances
Dimensions in millimetres
Column 1 Column 2 Column 3 Column 4
Permissible deviations from declared
Nominal size
Range of declared pipe internal diameters
internal diameter
DN
minimum maximum ± mm
100 97 103 1,5
110 107 113 1,5
125 122 128 1,5
150 147 153 1,5
200 196 204 1,5
225 221 229 1,5
250 246 255 1,5
300 296 306 1,8
350 346 357 2,1
400 396 408 2,4
450 446 459 2,7
500 496 510 3,0
600 595 612 3,6
700 695 714 4,2
800 795 816 4,2
900 895 918 4,2
1 000 995 1 020 5,0
1 200 1 195 1 220 5,0
1 400 1 395 1 420 5,0
1 600 1 595 1 620 5,0
1 800 1 795 1 820 5,0
2 000 1 995 2 020 5,0
2 200 2 195 2 220 5,0
2 400 2 395 2 420 6,0
2 600 2 595 2 620 6,0
2 800 2 795 2 820 6,0
3 000 2 995 3 020 6,0
3 200 3 195 3 220 6,0
3 400 3 395 3 420 6,0
3 600 3 595 3 620 6,0
3 800 3 795 3 820 7,0
4 000 3 995 4 020 7,0
NOTE 1 When a non-preferred size is selected from Table 3, the range of diameters and the permissible deviations shall be
interpolated between th
...