ISO 5167-1:1991/Cor 1:1997
(Corrigendum)Measurement of fluid flow by means of pressure differential devices — Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full — Technical Corrigendum 1: (Applies to French version only)
Measurement of fluid flow by means of pressure differential devices — Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full — Technical Corrigendum 1: (Applies to French version only)
Mesure de débit des fluides au moyen d'appareils déprimogènes — Partie 1: Diaphragmes, tuyères et tubes de Venturi insérés dans des conduites en charge de section circulaire — Rectificatif technique 1
General Information
- Status
- Withdrawn
- Publication Date
- 29-Jan-1997
- Withdrawal Date
- 29-Jan-1997
- Technical Committee
- ISO/TC 30/SC 2 - Pressure differential devices
- Drafting Committee
- ISO/TC 30/SC 2 - Pressure differential devices
- Current Stage
- 9599 - Withdrawal of International Standard
- Start Date
- 24-Feb-2003
- Completion Date
- 12-Feb-2026
Relations
- Effective Date
- 06-Jun-2022
- Effective Date
- 16-Oct-2025
- Effective Date
- 12-May-2008
- Effective Date
- 15-Apr-2008
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
ISO 5167-1:1991/Cor 1:1997 is a standard published by the International Organization for Standardization (ISO). Its full title is "Measurement of fluid flow by means of pressure differential devices — Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full — Technical Corrigendum 1: (Applies to French version only)". This standard covers: Measurement of fluid flow by means of pressure differential devices — Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full — Technical Corrigendum 1: (Applies to French version only)
Measurement of fluid flow by means of pressure differential devices — Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full — Technical Corrigendum 1: (Applies to French version only)
ISO 5167-1:1991/Cor 1:1997 is classified under the following ICS (International Classification for Standards) categories: 17.120.10 - Flow in closed conduits. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 5167-1:1991/Cor 1:1997 has the following relationships with other standards: It is inter standard links to ISO 5167-1:1991, ISO 5167-1:2003; is excused to SIST ISO 5167-1:1996, ISO 5167-1:1991. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 5167-1:1991/Cor 1:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME INTERNATIONALE ISO 51679I:l991
RECTIFICATIF TECHNIQUE 1
Publi6 1997-02-I 5
INTERNATIONAL ORGANIZATION FOR STANDARUZAnON. MDKjJYHAPO~HAFI OPMM3AlJHR fl0 CTAHAAPTH3AuHH* ORGANISATION INlEftNATIONALE DE NORMALISATION
Mesure de débit des fluides au moyen d’appareils
déprimogènes -
Partie 1:
Diaphragmes, tuyères et tubes de Venturi insérés dans des
conduites en charge de section circulaire
RECTIFICATIF TECHNIQUE 1
Measurement of fluid flow by means of pressure differential devices -
Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full
TECHNICAL CORRIGENDUM I
Le Rectif
...
NORME INTERNATIONALE ISO 51679I:l991
RECTIFICATIF TECHNIQUE 1
Publi6 1997-02-I 5
INTERNATIONAL ORGANIZATION FOR STANDARUZAnON. MDKjJYHAPO~HAFI OPMM3AlJHR fl0 CTAHAAPTH3AuHH* ORGANISATION INlEftNATIONALE DE NORMALISATION
Mesure de débit des fluides au moyen d’appareils
déprimogènes -
Partie 1:
Diaphragmes, tuyères et tubes de Venturi insérés dans des
conduites en charge de section circulaire
RECTIFICATIF TECHNIQUE 1
Measurement of fluid flow by means of pressure differential devices -
Part 1: Orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full
TECHNICAL CORRIGENDUM I
Le Rectif
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...