ISO/DTR 25700
(Main)Electrically propelled road vehicles — Specification items for electric propulsion components
- Status
- Not Published
- Technical Committee
- ISO/TC 22/SC 37 - Electrically propelled vehicles
- Current Stage
- 5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
- Start Date
- 13-Nov-2026
- Due Date
- 13-Nov-2026
- Completion Date
- 13-Nov-2026
Buy Documents
ISO/DTR 25700 - Electrically propelled road vehicles — Specification items for electric propulsion components
REDLINE ISO/DTR 25700 - Electrically propelled road vehicles — Specification items for electric propulsion components
ISO/DTR 25700 is an ISO draft technical report on specification items for electric propulsion components in electrically propelled road vehicles. It is aimed at suppliers and customers who exchange requirement specifications for voltage class B electric-propulsion systems and components, and it lists typical items to specify together with the standards to use when a test method is already defined.
What does ISO/DTR 25700 specify?
ISO/DTR 25700 specifies a common set of specification items for electric-propulsion system/component of voltage class B. Its purpose is to give customers and suppliers a shared list of items so they can compare proposals using the same language and the same reference methods.
| Clause | Content |
|---|---|
| 1 | Scope for voltage class B electric-propulsion system/component specification items |
| 2 | Normative references |
| 3 | Terms and definition |
| 4 | Abbreviated terms |
| 5 | Specification items |
| Bibliography | Supporting standards and regulations cited in the document |
Clause 5 is the main technical part. It organizes the items by category and points to the relevant standards where an existing method is already available.
What are the key requirements of ISO/DTR 25700?
ISO/DTR 25700 does not set a test program of its own. Instead, it tells users what to specify for an electric propulsion component and where to find the method or definition when one already exists.
System and environment items
Table 1 starts with operating environment and cooling-related items: temperature, humidity, barometric pressure, cooling method, coolant temperature, coolant flow rate and pressure loss. In practice, these define the conditions the component must tolerate and the thermal interface the buyer and supplier must agree on.
The same table also covers motor characteristics such as motor type, number of pole pairs, back EMF, rotation sensor, rotation direction and temperature sensor. These items matter because they fix the motor architecture, sensing arrangement and installation orientation.
Electrical performance items
For electrical input, Table 1 separates voltage class A and voltage class B items. It includes maximum current, inrush current and quiescent current for one side of the interface, and working voltage range, unlimited operating capability voltage range, rated voltage and overvoltage limit for voltage class B items. The table also points to voltage ripple and current ripple where relevant. In practice, this is the set of values that defines the usable electrical envelope and the operating limits of the component.
For output and drive behavior, Table 1 lists maximum power for duration of t0, maximum torque for duration of t0, maximum current for duration of t0, maximum speed, electrical frequency, rated speed and cogging torque. It also includes torque characteristic, torque accuracy, torque response, torque ripple, switching frequency, modulation method, modulation index and system loss/efficiency. These are the core figures used to compare candidate components and to check whether the motor or inverter will meet the intended vehicle use.
Environmental, function and safety items
Table 1 adds degrees of protection, insulation resistance, EMC, ESD and NVH. These items matter because they cover ingress protection, electrical isolation, electromagnetic behavior and noise and vibration.
The function section covers communication type, number of channels, state machine, wake-up condition, control mode, inverter input voltage, derating control, passive discharge and active discharge. It then extends to ASIL, functional safety, fail safe, emergency power supply, cybersecurity, immobilizer authentication, UDS and service tool. In practice, this is the checklist for how the component communicates, protects itself, behaves under fault or stress, and supports diagnosis and service.
What terms does ISO/DTR 25700 define?
- Voltage range - A general term covering voltage sub-class, working voltages and deviations from working voltages.
- Working voltage range - The DC voltage range that can occur in an electric system under normal operating conditions.
- Unlimited operating capability voltage range - The voltage operating ranges of OS1.
- Rated voltage - The central value of OS1.
- Torque response - The time until the measured torque reaches the requested torque.
- ASIL - Automotive safety integrity level, used when discussing functional safety targets.
- UDS - Unified diagnostic service, used for diagnostic communication between on-board controllers and service tools.
- Cybersecurity - Road vehicle cybersecurity, meaning protection of vehicle assets against threat scenarios affecting the vehicle, its functions and its electrical or electronic components.
Who uses ISO/DTR 25700?
ISO/DTR 25700 is used by suppliers and customers of electric propulsion systems and components when they exchange requirement specifications. It is also useful to powertrain engineers, test teams, quality managers and buyers who need a shared checklist for defining, comparing and reviewing voltage class B electric propulsion items.
Which standards are used with ISO/DTR 25700?
| Standard | What it contributes |
|---|---|
| ISO 21498-1 | Voltage sub-classes and characteristics for voltage class B systems and components |
| ISO 21498-2 | Electrical tests for components, including voltage ripple-related items |
| ISO 21782-1, ISO 21782-2, ISO 21782-3, ISO 21782-5, ISO 21782-6 | General test conditions, performance testing and operating load testing for the motor system, motor and inverter |
| ISO 16750-2 | Electrical loads for road-vehicle electrical and electronic equipment |
| ISO 20653 | Degrees of protection (IP code) |
| IEC 61000-4-5 | Surge immunity test |
| IEC 60050-551-20 | Vocabulary for fundamental frequency |
| ISO 26262-1 to ISO 26262-12, GB/T 34590 | Functional safety framework and related guidance |
| ISO/SAE 21434, UN Regulation No. 155, UN Regulation No. 156 | Cybersecurity and software update management context |
| ISO 14229-1 to ISO 14229-8 | Unified diagnostic services (UDS) and its transport and network implementations |
What does the ISO/DTR 25700 document contain?
ISO/DTR 25700 contains a terms section, an abbreviation list, and a main specification-item table. Table 1 is the core of the document: it groups items by system environment, motor characteristics, performance, environmental performance and function, and it links many of them to companion standards.
Clause 3 provides definitions for technical terms used in the table, including voltage ranges, torque and current behavior, discharge methods, functional safety and cybersecurity. Clause 4 expands the abbreviations used throughout the document, such as AC, DC, CAN, CAN-FD, EMC, NVH, ASIL and UDS.
Figure 1 defines rotation direction using side and front views of the output shaft side. The bibliography identifies the external standards and regulations that support the specification items, test methods and diagnostic references used in the table.
Buy Documents
ISO/DTR 25700 - Electrically propelled road vehicles — Specification items for electric propulsion components
REDLINE ISO/DTR 25700 - Electrically propelled road vehicles — Specification items for electric propulsion components
Get Certified
Connect with accredited certification bodies for this standard

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DEKRA Certification Inc.
DEKRA US certification services.
Sponsored listings
Frequently Asked Questions
ISO/DTR 25700 is a draft published by the International Organization for Standardization (ISO). Its full title is "Electrically propelled road vehicles — Specification items for electric propulsion components". This standard covers: Electrically propelled road vehicles — Specification items for electric propulsion components
Electrically propelled road vehicles — Specification items for electric propulsion components
ISO/DTR 25700 is classified under the following ICS (International Classification for Standards) categories: 43.120 - Electric road vehicles. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/DTR 25700 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definition
- 3.1 barometric pressure, noun
- 3.2 coolant temperature, noun
- 3.3 coolant flow rate, noun
- 3.4 pressure loss, noun
- 3.5 number of pole pairs, noun
- 3.6 back EMF, noun
- 3.7 rotation sensor, noun
- 3.8 rotation direction, noun
- 3.9 temperature sensor, noun
- 3.10 voltage range, noun
- 3.11 working voltage range, noun
- 3.12 inrush current, noun
- 3.13 quiescent current, noun
- 3.14 unlimited operating capability voltage range, noun
- 3.15 rated voltage, noun
- 3.16 overvoltage limit, noun
- 3.17 surge voltage, noun
- 3.18 voltage ripple, noun
- 3.19 current ripple, noun
- 3.20 maximum power for duration of t , noun
- 3.21 maximum torque for duration of t , noun
- 3.22 maximum current for duration of t , noun
- 3.23 maximum speed, noun
- 3.24 maximum electrical frequency, noun
- 3.25 fundamental frequency, noun
- 3.26 rated speed, noun
- 3.27 cogging torque, noun
- 3.28 torque characteristic, noun
- 3.29 torque accuracy, noun
- 3.30 torque response, noun
- 3.31 torque ripple, noun
- 3.32 switching frequency, noun
- 3.33 modulation method, noun
- 3.34 modulation index, noun
- 3.35 system loss/efficiency, noun
- 3.36 insulation resistance, noun
- 3.37 communication type, noun
- 3.38 derating control, noun
- 3.39 passive discharge, noun
- 3.40 active discharge, noun
- 3.41 functional safety, noun
- 3.42 fail safe, noun
- 3.43 active short circuit, noun
- 3.44 emergency power supply, noun
- 3.45 cybersecurity, noun
- 3.46 immobilizer authentication, noun
- 4 Abbreviated terms
- 5 Specification items
- 2 ISO 14229-3 ISO
- Bibliography
Introduction
The commercial flow of electric propulsion system/component is increased by the popularization of the electric-propulsion vehicle. However, when a customer and a supplier exchange a requirement specification, a great deal of effort is required to confirm whether the proposal matches the requirement by “dissimilar terms” and “uneven items” and to align the specification. Therefore, by defining and sharing the list of specification items, the recognition deviation at the specification matching can be reduced and efficiency can be improved. As a result, it can contribute to the revitalization of the market.
FINAL DRAFT Technical Report ISO/DTR 25700:2026(en) Electrically propelled road vehicles — Specification items for electric propulsion components
1 Scope
This document lists typical specification items of the electric-propulsion system/component of voltage class B. The specification items are used in exchanging requirement specification between suppliers and customers. If the test method of specification item has already been defined in anInternational Standard, the number of the International Standard is included.
2 Normative references
There are no normative references in this document.
3 Terms and definition
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 barometric pressure, noun
force per unit area exerted by the weight of the atmosphere
3.2 coolant temperature, noun
temperature of coolant at the inlet of the component
3.3 coolant flow rate, noun
amount of fluid moved
3.4 pressure loss, noun
pressure difference between the inlet and the outlet of coolant
3.5 number of pole pairs, noun
number of pairs of N pole and S pole of motor
3.6 back EMF, noun
voltage induced by the rotating magnetic force of a motor
3.7 rotation sensor, noun
sensor for detecting rotation angle or rotor speed
ISO/DTR 25700:2026(en)
3.8 rotation direction, noun
direction defined as seen from the output shaft side a) Side view b) Front view Key 1 electric machine housing 2 output shaft 3 front view direction 4 clockwise 5 counterclockwise Figure 1 — Definition of rotation direction
3.9 temperature sensor, noun
sensor detecting temperature of e.g. power semiconductor, motor stator, coolant and transmission fluid
3.10 voltage range, noun
general term covering voltage sub-class, working voltages and deviations from working voltages [1] [SOURCE: ISO 21498-1:2021 , 3.14]
3.11 working voltage range, noun
DC voltage range (3.10) that can occur in an electric system under normal operating conditions
3.12 inrush current, noun
large current that flows temporarily when the component is turned on
3.13 quiescent current, noun
current consumed by the component when it is in the sleep state
3.14 unlimited operating capability voltage range, noun
voltage operating ranges of OS1 [2] Note 1 to entry: See ISO 21498-1 about OS1.
3.15 rated voltage, noun
central value of OS1 [2] Note 1 to entry: See ISO 21498-1 about OS1.
ISO/DTR 25700:2026(en)
3.16 overvoltage limit, noun
maximum voltage that can occur under abnormal operating conditions
3.17 surge voltage, noun
transient wave of electrical current, voltage or power propagating along a line or a circuit and characterized by a rapid increase followed by a slower decrease [3] [SOURCE: I EC 610 0 0 - 4 -5:2014/A M D1: 2017 , 3.1.20]
3.18 voltage ripple, noun
overlay of an AC voltage on the DC voltage
3.19 current ripple, noun
overlay of an AC current on the DC current
3.20 maximum power for duration of t , noun
P t=t0 maximum power defined for the time frame t which can be constantly achieved for t seconds starting 0 0 from the steady state condition of RT and the nominal cooling conditions until the motor and inverter reach the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 , 3.10]
3.21 maximum torque for duration of t , noun
M t=t0 highest torque defined for the time frame t which can be constantly achieved for t seconds until the power 0 0 limitation at higher speed starting from the steady state condition of RT and the nominal cooling conditions until the motor reach the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 ; 3.13]
3.22 maximum current for duration of t , noun
I , noun t=t0 maximum current defined for the time frame t which can be constantly achieved for t seconds starting 0 0 from the steady state condition of room temperature (RT) and the nominal cooling conditions until the inverter, chopper reaches the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 ; 3.8]
3.23 maximum speed, noun
highest defined speed that can maintain maximum power Note 1 to entry: Maximum speed can be limited by a control software or the supplier's definitions.
3.24 maximum electrical frequency, noun
inverter fundamental frequency (3.25) at maximum speed (3.23)
3.25 fundamental frequency, noun
frequency of the fundamental component [5] [SOURCE: IEC 60050-551-20:2001 , 03]
ISO/DTR 25700:2026(en)
3.26 rated speed, noun
intersection of the maximum torque for duration of t (3.22) and iso-power line
[4] [SOURCE: ISO 21782-1:2023 , 3.22]
3.27 cogging torque, noun
cyclic torque in an unenergized permanent magnet motor resulting from the tendency of the rotor and stator to align themselves in position of minimum magnetic reluctance
3.28 torque characteristic, noun
motor output speed and torque
3.29 torque accuracy, noun
difference between the indicated torque and the measured torque
3.30 torque response, noun
response time until the measured torque reaches the requested torque
3.31 torque ripple, noun
pulsation torque with energised motor caused by either the structural distortion of motor construction or by the effect of current control, or both
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definition
- 3.1 barometric pressure, noun
- 3.2 coolant temperature, noun
- 3.3 coolant flow rate, noun
- 3.4 pressure loss, noun
- 3.5 number of pole pairs, noun
- 3.6 back EMF, noun
- 3.7 rotation sensor, noun
- 3.8 rotation direction, noun
- 3.9 temperature sensor, noun
- 3.10 voltage range, noun
- 3.11 working voltage range, noun
- 3.12 inrush current, noun
- 3.13 quiescent current, noun
- 3.14 unlimited operating capability voltage range, noun
- 3.15 rated voltage, noun
- 3.16 overvoltage limit, noun
- 3.17 surge voltage, noun
- 3.18 voltage ripple, noun
- 3.19 current ripple, noun
- 3.20 maximum power for duration of t , noun
- 3.21 maximum torque for duration of t , noun
- 3.22 maximum current for duration of t , noun
- 3.23 maximum speed, noun
- 3.24 maximum electrical frequency, noun
- 3.25 fundamental frequency, noun
- 3.26 rated speed, noun
- 3.27 cogging torque, noun
- 3.28 torque characteristic, noun
- 3.29 torque accuracy, noun
- 3.30 torque response, noun
- 3.31 torque ripple, noun
- 3.32 switching frequency, noun
- 3.33 modulation method, noun
- 3.34 modulation index, noun
- 3.35 system loss/efficiency, noun
- 3.36 insulation resistance, noun
- 3.37 communication type, noun
- 3.38 derating control, noun
- 3.39 passive discharge, noun
- 3.40 active discharge, noun
- 3.41 functional safety, noun
- 3.42 fail safe, noun
- 3.43 active short circuit, noun
- 3.44 emergency power supply, noun
- 3.45 cybersecurity, noun
- 3.46 immobilizer authentication, noun
- 4 Abbreviated terms
- 5 Specification items
- 2 ISO 26262-3 ISO
- 5 ISO 26262-6 ISO
- 8 ISO 26262-9 ISO
- 3 ISO 14229-4 ISO
- 6 ISO 14229-7 ISO
- Bibliography
Introduction
The commercial flow of electric propulsion system/component is increased by the popularization of the electric-propulsion vehicle. However, when a customer and a supplier exchange a requirement specification, a great deal of effort is required to confirm whether the proposal matches the requirement by “dissimilar terms” and “uneven items” and to align the specification. Therefore, by defining and sharing the list of specification items, the recognition deviation at the specification matching can be reduced and efficiency can be improved. As a result, it can contribute to the revitalization of the market.
ISO/DTR 25700:2026(en) Electrically propelled road vehicles — Specification items for electric propulsion components
1 Scope
This document lists typical specification items of the electric-propulsion system/component of voltage class B. The specification items are used in exchanging requirement specification between suppliers and customers. If the test method of specification item has already been defined in anInternational Standard, the number of the International Standard is included.
2 Normative references
There are no normative references in this document.
3 Terms and definition
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
3.1 barometric pressure, noun
force per unit area exerted by the weight of the atmosphere
3.2 coolant temperature, noun
temperature of coolant at the inlet of the component
3.3 coolant flow rate, noun
amount of fluid moved
3.4 pressure loss, noun
pressure difference between the inlet and the outlet of coolant
3.5 number of pole pairs, noun
number of pairs of N pole and S pole of motor
3.6 back EMF, noun
voltage induced by the rotating magnetic force of a motor
3.7 rotation sensor, noun
sensor for detecting rotation angle or rotor speed
ISO/DTR 25700:2026(en)
3.8 rotation direction, noun
direction defined as seen from the output shaft side
a) Side view b) Front view Key 1 electric machine housing 2 output shaft 3 front view direction 4 clockwise 5 counterclockwise Figure 1 — Definition of rotation direction
3.9 temperature sensor, noun
sensor detecting temperature of e.g. power semiconductor, motor stator, coolant and transmission fluid
3.10 voltage range, noun
general term covering voltage sub-class, working voltages and deviations from working voltages [1] [SOURCE: ISO 21498-1:2021 , 3.14]
3.11 working voltage range, noun
DC voltage range (3.10) that can occur in an electric system under normal operating conditions
3.12 inrush current, noun
large current that flows temporarily when the component is turned on
3.13 quiescent current, noun
current consumed by the component when it is in the sleep state
3.14 unlimited operating capability voltage range, noun
voltage operating ranges of OS1 [2] Note 1 to entry: See ISO 21498-1 about OS1.
ISO/DTR 25700:2026(en)
3.15 rated voltage, noun
central value of OS1 [2] Note 1 to entry: See ISO 21498-1 about OS1.
3.16 overvoltage limit, noun
maximum voltage that can occur under abnormal operating conditions
3.17 surge voltage, noun
transient wave of electrical current, voltage or power propagating along a line or a circuit and characterized by a rapid increase followed by a slower decrease [3] [SOURCE: IEC 61000-4-5:2014/AMD1 , 3.1.20]
3.18 voltage ripple, noun
overlay of an AC voltage on the DC voltage
3.19 current ripple, noun
overlay of an AC current on the DC current
3.20 maximum power for duration of t , noun
P t=t0 maximum power defined for the time frame t which can be constantly achieved for t seconds starting from 0 0 the steady state condition of RT and the nominal cooling conditions until the motor and inverter reach the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 , 3.10]
3.21 maximum torque for duration of t , noun
M t=t0 highest torque defined for the time frame t which can be constantly achieved for t seconds until the power 0 0 limitation at higher speed starting from the steady state condition of RT and the nominal cooling conditions until the motor reach the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 ; 3.13]
3.22 maximum current for duration of t , noun
I , noun t=t0 maximum current defined for the time frame t which can be constantly achieved for t seconds starting from 0 0 the steady state condition of room temperature (RT) and the nominal cooling conditions until the inverter, chopper reaches the defined maximum temperature limit [4] [SOURCE: ISO 21782-1:2023 ; 3.8]
3.23 maximum speed, noun
highest defined speed that can maintain maximum power
ISO/DTR 25700:2026(en) Note 1 to entry: Maximum speed can be limited by a control software or the supplier's definitions.
3.24 maximum electrical frequency, noun
inverter fundamental frequency (3.25) at maximum speed (3.23)
3.25 fundamental frequency, noun
frequency of the fundamental component [5] [SOURCE: IEC 60050-551-20:2001 , 03]
3.26 rated speed, noun
intersection of the maximum torque for duration of t (3.22) and iso-power line
[4] [SOURCE: ISO 21782-1:2023 , 3.22]
3.27 cogging torque, noun
cyclic torque in an unenergized permanent magnet motor resulting from the tendency of the rotor and stator to align themselves in position of minimum magnetic reluctance
3.28 torque characteristic, noun
motor output speed and torque
3.29 torque accuracy, noun
difference between the indicated torque and the measured torque
3.30 torque response, noun
response time until the measured torque reaches the requested torque
3.31 torque ripple, noun
pulsation torque with energised motor caused by either the structural distortion of motor construction or by the effect of current control, or both
...