ISO 16075-2:2015
(Main)Guidelines for treated wastewater use for irrigation projects — Part 2: Development of the project
Guidelines for treated wastewater use for irrigation projects — Part 2: Development of the project
ISO 16075-2:2015 covers the following issues: criteria for the design of treated wastewater (herinafter: TWW) irrigation projects intended to prevent public health risks within the population that has been in direct or indirect contact with the TWW or with any product that has come in contact with the TWW; specifications of the following: the quality of the TWW that can be used for irrigation; the types of crops that can be irrigated with TWW; the combination of the qualities of the irrigated TWW and the types of crops that can be irrigated; the strategy of using barriers that can reduce the risks that arise from TWW irrigation; the correlation between the quality of the TWW, the irrigated crops, and the types of barriers that can be used; the distance required between the TWW irrigation areas and residential areas.
Lignes directrices pour l'utilisation des eaux usées traitées en irrigation — Partie 2: Développement du projet
L'ISO 16075-2:2015 traite des points suivants: les critères d'élaboration de projets d'irrigation utilisant des eaux usées traitées (abrégées en EUT), qui visent à prévenir les risques sanitaires pour la population qui a été en contact direct ou indirect avec les EUT ou avec tout produit qui s'est trouvé en contact avec les EUT; la spécification des paramètres suivants: la qualité des EUT pouvant être utilisées en irrigation; les types de cultures pouvant être irrigués par des EUT; la combinaison entre les niveaux de qualité des EUT utilisées en irrigation et les types de cultures qui peuvent être irriguées; la stratégie d'utilisation de barrières qui peuvent réduire les risques liés à l'irrigation par des EUT; la corrélation entre la qualité des EUT, les cultures irriguées et les types de barrières qui peuvent être utilisés; la distance requise entre les aires irriguées par des EUT et les zones résidentielles.
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 16075-2
First edition
2015-08-15
Guidelines for treated wastewater use
for irrigation projects —
Part 2:
Development of the project
Lignes directrices pour l’utilisation des eaux usées traitées en
irrigation —
Partie 2: Développement du projet
Reference number
ISO 16075-2:2015(E)
©
ISO 2015
---------------------- Page: 1 ----------------------
ISO 16075-2:2015(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2015, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 16075-2:2015(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions, and abbreviated terms . 1
3.1 General . 1
3.2 Use of treated wastewater (TWW) . 3
3.3 Wastewater quality . 4
3.4 Irrigation systems . 5
3.5 Wastewater system related components . 7
3.6 Abbreviated terms . 8
4 Public health and water quality parameters to take into consideration in TWW irrigation 9
4.1 Suggested treated wastewater quality levels . 9
4.2 TWW quality needed for irrigation use .13
4.2.1 Agricultural use .13
4.2.2 Urban use .13
4.3 Barriers concept .13
4.3.1 Types of barriers .14
4.3.2 Crops that can be irrigated without barriers .14
4.3.3 Barriers in the irrigation of public gardens .14
4.3.4 Barriers in the irrigation of fodder crops .14
4.3.5 Possible barriers .14
4.3.6 Barriers needed for irrigation with TWW according to their quality .16
4.3.7 Examples for calculating the numbers and types of barriers .16
5 Public health aspects of flood and furrow irrigation with TWW .17
6 Public health risks for surrounding residents .17
Annex A (informative) Adjustment of the TWW quality used for irrigation and the barriers
that can be used to the types of crops that can be irrigated with the TWW .18
Bibliography .24
© ISO 2015 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 16075-2:2015(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 282, Water reuse, Subcommittee SC 1, Treated
wastewater use for irrigation.
ISO 16075 consists of the following parts, under the general title Guidelines for treated wastewater use
for irrigation projects:
— Part 1: The basis of a reuse project for irrigation
— Part 2: Development of the project
— Part 3: Components of a reuse project for irrigation
The following parts are under preparation:
— Part 4: Monitoring
iv © ISO 2015 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 16075-2:2015(E)
Introduction
The increasing water scarcity and water pollution control efforts in many countries have made treated
municipal and industrial wastewater a suitable economic means of augmenting the existing water
supply especially when compared to expensive alternatives such as desalination or the development
of new water sources involving dams and reservoirs. Water reuse makes it possible to close the water
cycle at a point closer to cities by producing “new water” from municipal wastewater and reducing
wastewater discharge to the environment.
An important new concept in water reuse is the “fit-to-purpose” approach, which entails the production
of reclaimed water quality that meets the needs of the intended end-users. In the situation of reclaimed
water for irrigation, the reclaimed water quality can induce an adaptation of the type of plant grown.
Thus, the intended water reuse applications are to govern the degree of wastewater treatment required
and inversely, the reliability of wastewater reclamation processes and operation.
Treated wastewater can be used for various non-potable purposes. The dominant applications for the
use of treated wastewater (also referred to as reclaimed water or recycled water) include agricultural
irrigation, landscape irrigation, industrial reuse, and groundwater recharge. More recent and rapidly
growing applications are for various urban uses, recreational and environmental uses, and indirect and
direct potable reuse.
Agricultural irrigation was, is, and will likely remain the largest reuse water consumer with recognized
benefits and contribution to food security. Urban water recycling, landscape irrigation in particular,
is characterized by fast development and will play a crucial role for the sustainability of cities in the
future including energy footprint reduction, human well-being, and environmental restoration.
It is worth noting again that the suitability of treated wastewater for a given type of reuse depends
on the compatibility between the wastewater availability (volume) and water irrigation demand
throughout the year, as well as on the water quality and the specific use requirements. Water reuse
for irrigation can convey some risks for health and environment, depending on the water quality, the
irrigation water application method, the soil characteristics, the climate conditions, and the agronomic
practices. Consequently, the public health and potential agronomic and environmental adverse impacts
are to be considered as priority elements in the successful development of water reuse projects for
irrigation. To prevent such potential adverse impacts, the development and application of international
guidelines for the reuse of treated wastewater is essential.
The main water quality factors that determine the suitability of treated wastewater for irrigation
are pathogen content, salinity, sodicity, specific ion toxicity, other chemical elements, and nutrients.
Local health authorities are responsible for establishing water quality threshold values depending on
authorized uses and they are also responsible for defining practices to ensure health and environmental
protection taking into account local specificities.
From an agronomic point of view, the main limitation in using treated wastewater for irrigation arises
from its quality. Treated wastewater, unlike water supplied for domestic and industrial purposes,
contains higher concentrations of inorganic suspended and dissolved materials (total soluble salts,
sodium, chloride, boron, and heavy metals), which can damage the soil and irrigated crops. Dissolved
salts are not removed by conventional wastewater treatment technologies and appropriate good
management, agronomic, and irrigation practices should be used to avoid or minimize potential
negative impacts.
The presence of nutrients (nitrogen, phosphorus, and potassium) can become an advantage due to
possible saving in fertilizers. However, the amount of nutrients provided by treated wastewater along
the irrigation period is not necessarily synchronized with crop requirements and the availability of
nutrients depends on the chemical forms.
This guideline provides guidance for healthy, hydrological, environmental and good operation,
monitoring, and maintenance of water reuse projects for unrestricted and restricted irrigation of
agricultural crops, gardens, and landscape areas using treated wastewater. The quality of supplied
treated wastewater has to reflect the possible uses according to crop sensitivity (health-wise and
© ISO 2015 – All rights reserved v
---------------------- Page: 5 ----------------------
ISO 16075-2:2015(E)
agronomy-wise), water sources (the hydrologic sensitivity of the project area), the soil, and climate
conditions.
This guideline refers to factors involved in water reuse projects for irrigation regardless of size,
location, and complexity. It is applicable to intended uses of treated wastewater in a given project even
if such uses will change during the project’s lifetime as a result of the changes in the project itself or in
the applicable legislation.
The key factors in assuring the health, environmental, and safety of water reuse projects in irrigation
are the following:
— meticulous monitoring of treated wastewater quality to ensure the system functions as planned
and designed;
— design and maintenance instructions of the irrigation systems to ensure their proper long-term
operation;
— compatibility between the treated wastewater quality, the distribution method, and the intended
soil and crops to ensure a viable use of the soil and undamaged crop growth;
— compatibility between the treated wastewater quality and its use to prevent or minimize possible
contamination of groundwater or surface water sources.
vi © ISO 2015 – All rights reserved
---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 16075-2:2015(E)
Guidelines for treated wastewater use for irrigation
projects —
Part 2:
Development of the project
1 Scope
This part of ISO 16075 covers the following issues:
— criteria for the design of treated wastewater (herinafter: TWW) irrigation projects intended to
prevent public health risks within the population that has been in direct or indirect contact with the
TWW or with any product that has come in contact with the TWW;
— specifications of the following:
i) the quality of the TWW that can be used for irrigation;
ii) the types of crops that can be irrigated with TWW;
iii) the combination of the qualities of the irrigated TWW and the types of crops that can be
irrigated;
iv) the strategy of using barriers that can reduce the risks that arise from TWW irrigation;
v) the correlation between the quality of the TWW, the irrigated crops, and the types of barriers
that can be used;
vi) the distance required between the TWW irrigation areas and residential areas.
vii) none of the parts of this part of ISO 16075 are intended to be used for certification purposes.
2 Normative references
There are no normative references.
3 Terms, definitions, and abbreviated terms
3.1 General
3.1.1
aquifer
underground layer of water-bearing permeable rock or unconsolidated materials (gravel, sand, or silt)
from which groundwater can be extracted
3.1.2
background water
freshwater (3.1.10) supplied for domestic, institutional, commercial, and industrial use from which
wastewater (3.1.22) is created
© ISO 2015 – All rights reserved 1
---------------------- Page: 7 ----------------------
ISO 16075-2:2015(E)
3.1.3
barrier
any means that reduces or prevents the risk of human infection by preventing contact between the
TWW and the ingested produce or other means that, for example, reduces the concentration of
microorganisms in the TWW or prevents their survival on the ingested produce
3.1.4
environment
surroundings in which an organization (3.1.13) operates including air, water, land, natural resources,
flora, fauna, humans, and their interrelation
3.1.5
environmental aspect
element of an organization’s (3.1.13) activities, projects, or products that can interact with the
environment (3.1.4)
3.1.6
environmental impact
any change to environmental quality whether adverse or beneficial or wholly or partly resulting from
an organization’s (3.1.13) activities, projects, or products (3.1.15)
3.1.7
environmental parameter
quantifiable attribute of an environmental aspect (3.1.5)
3.1.8
fodder crops
crops not for human consumption such as pastures and forage, fiber, ornamental, seed, forest, and turf
crops
3.1.9
food crops
crops which are intended for human consumption often further classified as to whether the food crop is
to be cooked, processed, or consumed raw
3.1.10
freshwater
naturally occurring water on the Earth’s surface (in ice, lakes, rivers, and streams) and underground as
groundwater in aquifers (3.1.1)
Note 1 to entry: Freshwater includes desalinated seawater and desalinated brackish water, but excludes seawater
and brackish water.
3.1.11
irrigation project
design, development, construction, selection of equipment, operation, and monitoring of works to
provide suitable TWW irrigation
3.1.12
non-potable water
NPW
water that is not of drinking water quality
Note 1 to entry: It generally refers to wastewater (3.1.22) or TWW, but can also include other waters of non-
drinking quality.
3.1.13
organization
group of people and facilities with an arrangement of responsibilities, authorities, and relationships
2 © ISO 2015 – All rights reserved
---------------------- Page: 8 ----------------------
ISO 16075-2:2015(E)
3.1.14
process
set of interrelated or interacting activities which transform inputs into outputs
Note 1 to entry: Inputs to a process are generally outputs of other processes.
Note 2 to entry: Processes in an organization (3.1.13) are generally planned and carried out under controlled
conditions to add value.
3.1.15
product
any goods or services
Note 1 to entry: This includes interconnected and/or interrelated goods or services.
3.1.16
public health aspect
element of an organization’s (3.1.13) activities, projects, or products (3.1.15) that can interact with the
public health
3.1.17
public health impact
any change to public health, whether adverse or beneficial, wholly or partly resulting from an
organization’s (3.1.13) activities, projects, or products (3.1.15)
3.1.18
public health parameter
quantifiable attribute of a public health aspect (3.1.17)
3.1.19
soil
layer of unconsolidated material consisting of weathered material particles, dead and living organic
matter, air space, and the soil solution (3.1.20)
3.1.20
soil solution
liquid phase of the soil (3.1.19) and its solutes
3.1.21
stakeholder
individual, group, or organization (3.1.13) that has an interest in an organization or activity
Note 1 to entry: Usually, a stakeholder can affect or is affected by the organization or the activity.
3.1.22
wastewater
wastewater collected principally by municipalities that can include spent or used water from domestic,
institutional, commercial, or industrial sources and can include storm water
3.1.23
water reuse
use of treated wastewater for beneficial use
Note 1 to entry: Synonymous also to water reclamation and water recycling.
3.2 Use of treated wastewater (TWW)
3.2.1
agriculture
science or practice of farming including cultivation of the soil (3.1.19) for the growing of crops and the
rearing of animals to provide food or other products (3.1.15)
© ISO 2015 – All rights reserved 3
---------------------- Page: 9 ----------------------
ISO 16075-2:2015(E)
3.2.2
landscape
all the visible features of an area of land often considered in terms of their aesthetic appeal such as
public and private gardens, parks, and road vegetation including lawns and turfed recreational areas
3.2.3
restricted irrigation
use of TWW for non-potable applications in settings where public access is controlled or restricted by
physical or institutional barriers
3.2.4
restricted urban irrigation
irrigation of areas in which public access during irrigation can be controlled such as some golf courses,
cemeteries, and highway medians
3.2.5
unrestricted irrigation
use of TWW for non-potable applications in settings where public access is not restricted
3.2.6
unrestricted urban irrigation
irrigation of areas in which public access during irrigation is not restricted, such as some gardens and
playgrounds
3.3 Wastewater quality
3.3.1
category A: very high quality TWW
raw wastewater (3.3.6) which has undergone physical and biological treatment, filtration (3.5.3) and
disinfection (3.5.2), and its quality is according to the description in row A of Table 1
3.3.2
category B: high quality TWW
raw wastewater (3.3.6) which has undergone physical and biological treatment, filtration (3.5.3) and
disinfection (3.5.2), and its quality is according to the description in row B of Table 1
3.3.3
category C: good quality TWW
raw wastewater (3.3.6) which has undergone physical and biological treatment and its quality is
according to the description in row C of Table 1
3.3.4
category D: medium quality TWW
raw wastewater (3.3.6) which has undergone physical and biological treatment and its quality is
according to the description in row D of Table 1
3.3.5
category E: extensively TWW
raw wastewater (3.3.6) which has undergone natural biological treatment process with long (minimum
10 d to 15 d) retention time and its quality is accordingly to the description in row E of Table 1
3.3.6
raw wastewater
wastewater (3.1.22) which has not undergone any treatment
4 © ISO 2015 – All rights reserved
---------------------- Page: 10 ----------------------
ISO 16075-2:2015(E)
3.3.7
thermo-tolerant coliforms
group of bacteria whose presence in the environment (3.1.4) usually indicates faecal contamination
(previously called faecal coliforms)
Note 1 to entry: In order to determine the quality of TWW, one can test for Escherichia coli (E. coli) or for faecal
coliforms since the difference in values is not significant.
3.4 Irrigation systems
3.4.1
boom sprinkler
mobile sprinkling machine (3.4.11) composed by two symmetrical pipes (booms) with sprinkler nozzles
distributed in one of the pipes and with the sprinkler action complemented by a gun sprinkler placed
at each end of both pipes; the nozzles work through a reaction effect (similar to a hydraulic tourniquet)
which drives the boom rotation at a desired speed
3.4.2
center-pivot and moving lateral irrigation machines
automated irrigation machine consisting of a number of self-propelled towers supporting a pipeline
rotating around a pivot point and through which water supplied at the pivot point flows radially
outward for distribution by sprayers or sprinklers (3.4.24) located along the pipeline
3.4.3
emitter
emitting pipe
dripper
device fitted to an irrigation lateral and intended to discharge water in the form of drops or continuous
flow at flow rates not exceeding 15 l/h, except during flushing
3.4.4
gravity flow irrigation systems
irrigation systems (3.4.8) where water is applied directly to the soil (3.1.19) surface and is not under
pressure
3.4.5
in-line emitter
emitter (3.4.3) intended for installation between two lengths of pipe in an irrigation lateral
3.4.6
irrigation gun
large discharge device being either a part circle or full circle sprinkler
3.4.7
irrigation sprayer
device which discharges water in the form of fine jets or in a fan shape without rotational movement of
its parts
3.4.8
irrigation system
assembly of pipes, components, and devices installed in the field for the purpose of irrigating a specific
area
3.4.9
micro-irrigation system
system capable of delivering water drops, tiny-streams, or minispray to the plants
Note 1 to entry: Surface and sub-surface drip irrigation and micro-spray irrigation (3.4.10) are the main types of
this system.
© ISO 2015 – All rights reserved 5
---------------------- Page: 11 ----------------------
ISO 16075-2:2015(E)
3.4.10
micro-spray irrigation systems
this system is characterized by water point sources similar to sprinkler’s (3.4.24) miniatures (micro-
sprinklers) which are placed along the laterals with a flow rate between 30 l/h and 150 l/h at pressure
heads of 15 m to 25 m and the corresponding wetted area between 2 m and 6 m
3.4.11
mobile sprinkling machine
sprinkling unit which is automatically moved across the soil (3.1.19) surface during the water application
3.4.12
on-line emitter
emitter (3.4.3) intended for installation in the wall of an irrigation lateral either directly or indirectly
by means such as tubing
3.4.13
perforating pipe system
emitting pipe (emitter/emitting pipe), continuous pipe, hose or tubing including collapsible hose with
perforations intended to discharge water in the form of drops or continuous flow at emission rates not
exceeding 15 l/h for each emitting unit
3.4.14
permanent system
stationary fixed-grid irrigation system (sprinklers) (3.4.24) for which sprinkler set positions are rigidly
fixed by semi-permanent or permanently installed irrigation laterals, for example, portable solid-set
irrigation system, buried irrigation system
3.4.15
portable system
system for which all or part of the network elements can be removed
3.4.16
pressurized irrigation systems
piped network systems under pressure
3.4.17
rotating sprinkler
device which, by its rotating motion around it’s vertical axis, distributes water over a circular area or
part of a circular area
3.4.18
self-moved system
unit where a lateral is mounted through the centre of a series of wheels and is moved as a whole
Note 1 to entry: Rotating sprinklers (3.4.17)/sprayers are placed on the lateral (also called wheel move).
3.4.19
self-propelled gun traveler
gun sprinkler on a cart or sled attached to the end of flexible pipe/hose
3.4.20
semi-permanent system
similar to the semi-portable system (3.4.21), but with portable laterals and permanent pumping plant,
main lines, and sub-mains
3.4.21
semi-portable system
similar to the portable system (3.4.15) except that the water source and the pumping plant are fixed
6 © ISO 2015 – All rights reserved
---------------------- Page: 12 ----------------------
ISO 16075-2:2015(E)
3.4.22
solid-set system
temporary fixed network where the laterals are positioned in the field throughout the irrigation season
3.4.23
spray
release of water from a sprinkler (3.4.24)
3.4.24
sprinkler
water distribution device of a variety of sizes and types, for example, impact sprinkler, fixed nozzle,
sprayer, and irrigation gun (3.4.6)
3.4.25
sprinkler irrigation systems
irrigation systems (3.4.8) composed of sprinklers (3.4.24)
3.4.26
stationary sprinkler systems
network of fixed sprinklers (3.4.24)
3.4.27
traveler irrigation machine
irrigation machine designed to irrigate a field sequentially strip by strip, while moving across the field
3.5 Wastewater system related components
3.5.1
additional disinfection
disinfection (3.5.2) of TWW in a water reuse (3.1.23) project intended to raise the quality of the TWW
before irrigation
3.5.2
disinfection
process (3.1.14) that destroys, inactivates, or removes microorganisms
3.5.3
filtration
process (3.1.14) or device for removing solid or colloidal material from wastewater (3.1.22) by physically
trapping the particles and removing them
3.5.4
membrane filtration
filtration (3.5.3) by membrane with pore size equal to or less than 0,45 μm
Note 1 to entry: Membrane filtration can also be considered as disinfection (3.5.2) according to the log units of
pathogen reduction that it achieves.
3.5.5
reservoir
system to store temporarily unused TWW depending on the demand for water irrigation and the
treatment plant discharge
Note 1 to entry: There are different types of reservoirs that can be used.
a) Open reservoirs which are commonly used for short-term storage with hydraulic residence times from one
day to two weeks.
b) Closed reservoirs for short-term storage to limit bacterial regrowth and external contamination common
with hydraulic residence time of 0,5 day to a week.
© ISO 2015 – All rights reserved 7
---------------------- Page: 13 ----------------------
ISO 16075-2:2015(E)
c) Surface reservoirs for long-term or seasonal storage of TWW to accumulate water during periods of
treatment plant discharge higher than irrigation demand and to satisfy irrigation requirements when the
demand is higher than the treatment plant discharge. The hydraulic residence time changes according to the
seasons.
d) Aquifer storage and recovery for long-term storage which is commonly combined with soil aquifer treatment
(by means of infiltration basins). The residence time is also a variable that is affected by the TWW discharge
and irrigation demand. This aquifer storage should not contribute to the aquifer recharge for potential
potable water use.
3.5.6
storage
retained temporary unused TWW for short- or long-term before their release for use in irrigation
systems (3.4.8)
3.5.7
TWW pumping stations and transport systems
system of pipelines and pumps transporting the TWW from the WWTP to storage (3.5.6) reservoirs
and to the use site
3.5.8
wastewater treatment plant
WWTP
fac
...
NORME ISO
INTERNATIONALE 16075-2
Première édition
2015-08-15
Lignes directrices pour l’utilisation
des eaux usées traitées en irrigation —
Partie 2:
Développement du projet
Guidelines for treated wastewater use for irrigation projects —
Part 2: Development of the project
Numéro de référence
ISO 16075-2:2015(F)
©
ISO 2015
---------------------- Page: 1 ----------------------
ISO 16075-2:2015(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2015, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 16075-2:2015(F)
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et abréviations . 1
3.1 Généralités . 1
3.2 Utilisation des eaux usées traitées (EUT) . 4
3.3 Qualité des eaux usées. 4
3.4 Systèmes d’irrigation . 5
3.5 Éléments associés aux stations d’épuration des eaux usées . 7
3.6 Abréviations . 9
4 Paramètres de santé publique et de qualité de l’eau à prendre en compte pour
l’irrigation par des eaux usées traitées . 9
4.1 Niveaux suggérés de qualité des eaux usées traitées . 9
4.2 Qualité requise des EUT pour leur utilisation en irrigation .12
4.2.1 Utilisation agricole .12
4.2.2 Utilisation urbaine .12
4.3 Concept de barrières .12
4.3.1 Types de barrières .13
4.3.2 Cultures pouvant être irriguées sans barrière .13
4.3.3 Barrières pour l’irrigation des jardins publics.13
4.3.4 Barrières pour l’irrigation des cultures fourragères .13
4.3.5 Barrières possibles .13
4.3.6 Barrières requises pour l’irrigation par des EUT en fonction de la qualité
de ces dernières .15
4.3.7 Exemples de détermination du nombre et des types de barrières .15
5 Aspects de santé publique liés à l’irrigation par inondation et à l’irrigation en
sillons utilisant des EUT .16
6 Risques de santé publique pour les riverains .16
Annexe A (informative) Adaptation de la qualité des EUT utilisées en irrigation et des
barrières qu’il est possible d’utiliser vis-à-vis des types de cultures pouvant être
irrigués par les EUT .17
Bibliographie .23
© ISO 2015 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 16075-2:2015(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1 Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer
un engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 282, Recyclage des eaux, sous-
comité SC 1, Recyclage des eaux usées traitées à des fins d’irrigation.
L’ISO 16075 comprend les parties suivantes, présentées sous le titre général Lignes directrices pour
l’utilisation des eaux usées traitées en irrigation:
— Partie 1: Les bases d’un projet de réutilisation en irrigation
— Partie 2: Développement du projet
— Partie 3: Éléments d’un projet de réutilisation en irrigation
Les parties suivantes sont en cours de préparation:
— Partie 4: Surveillance
iv © ISO 2015 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 16075-2:2015(F)
Introduction
Avec les efforts croissants déployés par de nombreux pays pour pallier la rareté et la pollution de
leurs ressources en eau, les eaux usées municipales et industrielles traitées sont devenues un moyen
économique judicieux pour augmenter les quantités disponibles, en particulier si on les compare à
des alternatives coûteuses telles que le dessalement ou le développement de nouvelles sources d’eau
impliquant la construction de barrages et de réservoirs. La réutilisation de l’eau permet de fermer le
cycle de l’eau plus près des villes, en produisant une «eau neuve» à partir des eaux usées municipales et
en réduisant les rejets d’eaux usées dans l’environnement.
Un nouveau concept, important, en matière de réutilisation des eaux usées est l’approche «adaptée
aux besoins», qui implique la production d’eau réutilisée d’une qualité répondant aux besoins des
utilisateurs finaux prévus. Dans le cas de l’eau réutilisée destinée à l’irrigation, la qualité de l’eau peut
conduire à adapter les types de végétaux cultivés. Les applications prévues de réutilisation de l’eau
doivent donc dicter le degré de traitement requis pour les eaux usées, et réciproquement, de même que
la fiabilité et l’entretien des systèmes de réutilisation des eaux usées.
Les eaux usées traitées peuvent être utilisées à différentes fins, comme eau non potable. Les principales
applications utilisant les eaux usées traitées (dont on parle également en termes d’eaux réutilisées
ou d’eaux recyclées) comprennent l’irrigation des terres agricoles, l’irrigation des espaces verts, la
réutilisation industrielle et la recharge de nappe. Des applications plus récentes, qui se développent
rapidement, ciblent différents usages: urbain, récréatif, environnemental, ainsi que la réutilisation
directe et indirecte pour la production d’eau potable.
L’irrigation des terres agricoles a toujours été et restera probablement le secteur qui consomme le
plus d’eaux recyclées, les avantages de cette pratique et sa contribution à la sécurité alimentaire étant
reconnus. Le recyclage de l’eau pour des applications urbaines, et notamment l’irrigation des espaces
verts, se caractérise par un essor rapide et jouera un rôle décisif pour le développement durable des
villes dans le futur, y compris du point de vue de la réduction de l’empreinte énergétique, du bien-être
de la population et de la restauration de l’environnement.
Il est utile de rappeler que l’adéquation des eaux usées traitées à un type de réutilisation donné
dépend de la correspondance entre la disponibilité des eaux usées (leur volume) et la demande en
eau d’irrigation tout au long de l’année, ainsi que de la qualité de l’eau et des exigences spécifiques
d’utilisation. La réutilisation de l’eau pour l’irrigation peut comporter certains risques pour la santé
et l’environnement, en fonction de la qualité de l’eau, de la méthode d’application de l’eau d’irrigation,
des caractéristiques du sol, des conditions climatiques et des pratiques agronomiques. Par conséquent,
la santé publique et les impacts négatifs potentiels sur l’agriculture et l’environnement doivent être
considérés comme des aspects prioritaires pour le développement de projets de réutilisation de l’eau
pour l’irrigation qui donnent des résultats probants. Pour prévenir de tels impacts négatifs potentiels,
l’élaboration et l’application de lignes directrices internationales pour la réutilisation des eaux usées
traitées sont essentielles.
Les principaux facteurs déterminant, sur le plan qualitatif, l’adéquation des eaux usées traitées pour
l’irrigation, sont la teneur en agents pathogènes, la salinité, la sodicité, la toxicité d’ions spécifiques, les
autres éléments chimiques et les nutriments. Il incombe aux autorités sanitaires locales d’établir des
valeurs seuils de qualité de l’eau en fonction des utilisations autorisées et de définir des pratiques pour
garantir la protection sanitaire et environnementale en tenant compte des spécificités locales.
D’un point de vue agronomique, la principale limitation à l’utilisation des eaux usées traitées en irrigation
est liée à leur qualité. Les eaux usées traitées, contrairement à l’eau destinée à des usages domestiques
et industriels, contiennent de plus fortes concentrations de matières inorganiques en suspension
et dissoutes (sels totaux solubles, sodium, chlorure, bore et métaux lourds), qui peuvent nuire au sol
et aux cultures irriguées. Les sels dissous ne sont pas éliminés par les techniques conventionnelles
de traitement des eaux usées et il convient d’adopter de bonnes pratiques en matière de gestion,
d’agronomie et d’irrigation pour éviter ou réduire le plus possible les impacts négatifs potentiels.
La présence de nutriments (azote, phosphore et potassium) peut s’avérer avantageuse du fait des
économies d’engrais qu’il est possible de réaliser. Cependant, la quantité de nutriments fournie par les
© ISO 2015 – Tous droits réservés v
---------------------- Page: 5 ----------------------
ISO 16075-2:2015(F)
eaux usées traitées tout au long de la période d’irrigation ne coïncide pas forcément avec les quantités
requises par les cultures et la disponibilité des nutriments dépend de leur forme chimique.
Les présentes lignes directrices fournissent des préconisations pour assurer le déroulement, la
surveillance et la maintenance dans de bonnes conditions, sur les plans sanitaire, hydrologique et
environnemental, des projets de réutilisation de l’eau pour l’irrigation non restreinte et restreinte de
cultures agricoles, de jardins et d’espaces verts avec des eaux usées traitées. La qualité des eaux usées
traitées fournies doit correspondre aux utilisations possibles en fonction de la sensibilité des cultures
(sur le plan sanitaire et sur le plan agronomique), des sources d’eau (sensibilité hydrologique de la zone
concernée par le projet), du sol et des conditions climatiques.
Les présentes lignes directrices concernent les facteurs pris en compte dans les projets de réutilisation
de l’eau pour l’irrigation, indépendamment de leur taille, de leur complexité et de leur situation
géographique. Elles sont applicables aux utilisations des eaux usées traitées prévues dans un projet
donné, même si ces utilisations sont amenées à changer pendant la durée de vie du projet, du fait de
modifications apportées au projet lui-même ou à la législation en vigueur.
Les principaux facteurs entrant en ligne de compte pour assurer la sécurité, en matière de santé et
d’environnement, des projets de réutilisation de l’eau pour l’irrigation sont les suivants:
— un contrôle méticuleux de la qualité des eaux usées traitées pour garantir le fonctionnement du
système conformément aux prévisions et à la conception;
— des instructions de conception et de maintenance des systèmes d’irrigation pour garantir leur bon
fonctionnement à long terme;
— la compatibilité entre la qualité des eaux usées traitées, la méthode de distribution et le type de
sol et de cultures à irriguer pour garantir une exploitation viable du sol et une croissance normale
des cultures;
— l’adéquation entre la qualité des eaux usées traitées et leur utilisation pour empêcher ou réduire
au minimum une éventuelle contamination des ressources naturelles d’eaux souterraines ou
d’eaux de surface.
vi © ISO 2015 – Tous droits réservés
---------------------- Page: 6 ----------------------
NORME INTERNATIONALE ISO 16075-2:2015(F)
Lignes directrices pour l’utilisation des eaux usées traitées
en irrigation —
Partie 2:
Développement du projet
1 Domaine d’application
La présente partie de l’ISO 16075 traite des points suivants:
— les critères d’élaboration de projets d’irrigation utilisant des eaux usées traitées (abrégées en EUT),
qui visent à prévenir les risques sanitaires pour la population qui a été en contact direct ou indirect
avec les EUT ou avec tout produit qui s’est trouvé en contact avec les EUT;
— la spécification des paramètres suivants:
i) la qualité des EUT pouvant être utilisées en irrigation;
ii) les types de cultures pouvant être irrigués par des EUT;
iii) la combinaison entre les niveaux de qualité des EUT utilisées en irrigation et les types de
cultures qui peuvent être irriguées;
iv) la stratégie d’utilisation de barrières qui peuvent réduire les risques liés à l’irrigation par des EUT;
v) la corrélation entre la qualité des EUT, les cultures irriguées et les types de barrières qui
peuvent être utilisés;
vi) la distance requise entre les aires irriguées par des EUT et les zones résidentielles;
vii) aucune partie de la présente partie de l’ISO 16075 n’est destinée à être utilisée à des fins de
certification.
2 Références normatives
Il n’y a pas de références normatives.
3 Termes, définitions et abréviations
3.1 Généralités
3.1.1
aquifère
couche souterraine de roche perméable ou de matériaux non consolidés (gravier, sable ou limon)
contenant de l’eau, dont on peut extraire de l’eau souterraine
3.1.2
eau fraîche initiale
eau douce (3.1.10) à usages domestique, institutionnel, commercial et industriel, à partir de laquelle les
eaux usées (3.1.22) sont produites
© ISO 2015 – Tous droits réservés 1
---------------------- Page: 7 ----------------------
ISO 16075-2:2015(F)
3.1.3
barrière
tout moyen réduisant ou prévenant le risque d’infection humaine en empêchant le contact entre
les EUT et les produits agricoles ingérés, ou autre moyen réduisant par exemple la concentration de
microorganismes dans les EUT ou empêchant leur survie sur les produits ingérés
3.1.4
environnement
cadre de fonctionnement d’une organisation (3.1.13), incluant l’air, l’eau, la terre, les ressources
naturelles, la flore, la faune, les êtres humains et leurs relations
3.1.5
aspect environnemental
élément des activités, projets ou produits d’une organisation (3.1.13) pouvant interagir avec
l’environnement (3.1.4)
3.1.6
impact environnemental
tout changement qualitatif, négatif ou positif, intervenant dans l’environnement, résultant en totalité
ou en partie des activités, projets ou produits (3.1.15) d’une organisation (3.1.13)
3.1.7
paramètre environnemental
attribut quantifiable d’un aspect environnemental (3.1.5)
3.1.8
cultures fourragères
cultures non destinées à la consommation humaine, telles que les cultures pastorales, ornementales,
forestières, les cultures pour la production de fourrage et de plantes à fibres, les cultures de
semences et de gazon
3.1.9
cultures vivrières
cultures destinées à la consommation humaine, souvent réparties en sous-catégories selon que les
produits sont destinés à être cuits, transformés ou consommés crus
3.1.10
eau douce
eau naturellement présente à la surface de la terre (dans la glace, les lacs, les rivières et les ruisseaux) et
sous terre sous forme d’eau souterraine dans les aquifères (3.1.1)
Note 1 à l’article: L’eau douce inclut l’eau de mer et l’eau saumâtre après leur dessalement, mais exclut l’eau de mer
et l’eau saumâtre.
3.1.11
projet d’irrigation
conception, développement, construction, sélection de matériels, exploitation et contrôle des travaux
pour fournir une irrigation appropriée par des EUT
3.1.12
eau non potable
ENP
eau ne présentant pas la qualité d’une eau destinée à la consommation
Note 1 à l’article: Ce terme se réfère généralement à des eaux usées (3.1.22) ou des EUT, mais peut inclure
également d’autres eaux de qualité non potable.
3.1.13
organisation
groupe de personnes et d’installations où les responsabilités, les autorités et les relations sont organisées
2 © ISO 2015 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO 16075-2:2015(F)
3.1.14
processus
ensemble d’activités interreliées ou présentant entre elles des interactions, qui transforment des
intrants en extrants
Note 1 à l’article: Les intrants d’un processus sont généralement les extrants d’autres processus.
Note 2 à l’article: Les processus d’une organisation (3.1.13) sont généralement planifiés et exécutés dans des
conditions contrôlées pour fournir une valeur ajoutée.
3.1.15
produit
n’importe quel type de bien ou de service
Note 1 à l’article: Ceci inclut les biens ou services interconnectés et/ou interreliés.
3.1.16
aspect lié à la santé publique
élément des activités, projets ou produits (3.1.15) d’une organisation (3.1.13) pouvant interagir avec la
santé publique
3.1.17
impact sur la santé publique
tout changement, négatif ou positif, intervenant dans le domaine de la santé publique, résultant en
totalité ou en partie des activités, projets ou produits (3.1.15) d’une organisation (3.1.13)
3.1.18
paramètre de santé publique
attribut quantifiable d’un aspect lié à la santé publique (3.1.17)
3.1.19
sol
couche de matériau non consolidé composée de particules de matériaux altérés, de matière organique
morte et vivante, d’interstices remplis d’air et de la solution du sol (3.1.20)
3.1.20
solution du sol
phase liquide du sol (3.1.19) avec ses éléments dissous
3.1.21
partie prenante
individu, groupe ou organisation (3.1.13) ayant un intérêt dans une organisation ou une activité
Note 1 à l’article: Habituellement, une partie prenante peut influencer ou être influencée par l’organisation
ou l’activité.
3.1.22
eaux usées
eaux collectées principalement par les municipalités; elles peuvent inclure des eaux résiduaires
d’origine domestique, institutionnelle, commerciale ou industrielle, ainsi que des eaux de pluie
3.1.23
réutilisation de l’eau
utilisation des eaux usées traitées à des fins utiles
Note 1 à l’article: Ce terme est également synonyme de récupération de l’eau et de recyclage de l’eau.
© ISO 2015 – Tous droits réservés 3
---------------------- Page: 9 ----------------------
ISO 16075-2:2015(F)
3.2 Utilisation des eaux usées traitées (EUT)
3.2.1
agriculture
science ou pratique d’exploitation de la terre, incluant le travail du sol (3.1.19) pour la culture de produits
et l’élevage d’animaux afin de fournir de la nourriture ou d’autres produits (3.1.15)
3.2.2
espaces verts
tous les éléments visibles d’une parcelle de terrain, souvent considérés du point de vue de leur intérêt
esthétique, tels les jardins publics et privés, les parcs et la végétation des routes, y compris les pelouses
et aires récréatives gazonnées
3.2.3
irrigation restreinte
utilisation d’EUT pour des applications non potables dans des lieux dont l’accès au public est contrôlé ou
restreint par des barrières physiques ou institutionnelles
3.2.4
irrigation urbaine restreinte
irrigation d’aires dont l’accès au public pendant l’irrigation peut être contrôlé (par exemple, certains
terrains de golf, cimetières et terre-pleins centraux d’autoroutes)
3.2.5
irrigation non restreinte
utilisation d’EUT pour des applications non potables dans des lieux dont l’accès au public n’est pas restreint
3.2.6
irrigation urbaine non restreinte
irrigation d’aires dont l’accès au public pendant l’irrigation n’est pas restreint (par exemple, certains
jardins et aires de jeux)
3.3 Qualité des eaux usées
3.3.1
classe A: EUT de très haute qualité
eaux usées brutes (3.3.6) ayant subi un traitement physique et biologique, une filtration (3.5.3) et une
désinfection (3.5.2), et dont la qualité répond à la description de la ligne A du Tableau 1
3.3.2
classe B: EUT de haute qualité
eaux usées brutes (3.3.6) ayant subi un traitement physique et biologique, une filtration (3.5.3) et une
désinfection (3.5.2), et dont la qualité répond à la description de la ligne B du Tableau 1
3.3.3
classe C: EUT de bonne qualité
eaux usées brutes (3.3.6) ayant subi un traitement physique et biologique, et dont la qualité répond à la
description de la ligne C du Tableau 1
3.3.4
classe D: EUT de qualité moyenne
eaux usées brutes (3.3.6) ayant subi un traitement physique et biologique, et dont la qualité répond à la
description de la ligne D du Tableau 1
3.3.5
classe E: eaux usées après traitement extensif
eaux usées brutes (3.3.6) ayant subi un processus de traitement biologique naturel avec un long temps
de séjour (10 j à 15 j au minimum), et dont la qualité répond à la description de la ligne E du Tableau 1
4 © ISO 2015 – Tous droits réservés
---------------------- Page: 10 ----------------------
ISO 16075-2:2015(F)
3.3.6
eaux usées brutes
eaux usées (3.1.22) n’ayant été soumises à aucun traitement
3.3.7
coliformes thermotolérants
groupe de bactéries dont la présence dans l’environnement (3.1.4) indique généralement une
contamination fécale (auparavant nommés coliformes fécaux)
Note 1 à l’article: Pour déterminer la qualité des EUT, on peut rechercher Escherichia coli (E. coli) ou les coliformes
fécaux car l’écart entre les valeurs n’est pas significatif.
3.4 Systèmes d’irrigation
3.4.1
rampe d’arrosage
machine d’arrosage mobile (3.4.11) composée de deux tuyaux (bras) symétriques et de buses d’arrosage
réparties sur l’un des tuyaux, l’action d’arrosage étant complétée par un canon d’arrosage placé à chaque
extrémité des deux tuyaux; l’action des buses produit un effet de réaction (similaire à un tourniquet
hydraulique) qui entraîne la rotation des bras à une vitesse voulue
3.4.2
machine d’irrigation à pivot central et déplacement latéral
machine d’irrigation automatique constituée d’un certain nombre de tours automotrices supportant
un tuyau qui tourne autour d’un pivot et par le biais duquel de l’eau fournie au niveau du pivot s’écoule
radialement vers l’extérieur pour être distribuée par des asperseurs ou des arroseurs (3.4.24) situés le
long du tuyau
3.4.3
émetteur
tuyau émetteur
goutteur
dispositif monté sur une conduite latérale d’irrigation et destiné à distribuer l’eau par goutte-à-goutte
ou en flux continu à un débit ne dépassant pas 15 l/h, excepté pendant la purge
3.4.4
système d’irrigation à écoulement gravitaire
système d’irrigation (3.4.8) où l’eau est appliquée directement sur la surface du sol (3.1.19) et n’est pas
sous pression
3.4.5
émetteur intercalé
émetteur (3.4.3) destiné à être installé entre deux longueurs de tuyau dans une conduite latérale
d’irrigation
3.4.6
canon d’irrigation
dispositif de distribution sur une longue portée, qui est soit un arroseur secteur de cercle, soit un
arroseur plein cercle
3.4.7
asperseur d’irrigation
dispositif distribuant l’eau sous forme de jets fins ou en éventail sans mouvement rotatif des parties qui
le constituent
3.4.8
système d’irrigation
assemblage de tuyaux, composants et dispositifs installés dans le champ dans le but d’irriguer une
zone spécifique
© ISO 2015 – Tous droits réservés 5
---------------------- Page: 11 ----------------------
ISO 16075-2:2015(F)
3.4.9
système de micro-irrigation
système pouvant délivrer de l’eau aux végétaux sous forme de gouttes, de micro-ruissellements ou de
micro-aspersion
Note 1 à l’article: L’irrigation par goutte-à-goutte en surface et sous la surface et l’irrigation par micro-
aspersion (3.4.10) sont les deux principaux systèmes de ce type.
3.4.10
système d’irrigation par micro-aspersion
système caractérisé par des sources d’eau ponctuelles ressemblant à des arroseurs (3.4.24) miniatures
(micro-arroseurs), qui sont placées le long des conduites latérales, délivrent un débit compris entre
30 l/h et 150 l/h avec des hauteurs manométriques (pressions de refoulement) allant de 15 m à 25 m et
arrosent sur une longueur comprise entre 2 m et 6 m
3.4.11
machine d’arrosage mobile
unité d’arrosage qui est déplacée automatiquement sur toute la surface du sol (3.1.19) pendant
l’application de l’eau
3.4.12
émetteur intégré
émetteur (3.4.3) destiné à être installé dans la paroi d’une conduite latérale d’irrigation, soit directement,
soit indirectement au moyen d’un tube par exemple
3.4.13
système de tuyau perforé
émetteur (émetteur/tuyau émetteur), tuyau, tuyau flexible ou tube continu, y compris tuyau flexible
pliable, pourvu de perforations destinées à distribuer l’eau par goutte-à-goutte ou en flux continu à un
débit d’émission ne dépassant pas 15 l/h pour chaque unité émettrice
3.4.14
système permanent
système d’irrigation (arroseurs) (3.4.24) statique à réseau fixe, pour lequel les positions des arroseurs
sont fixées de manière rigide sur des conduites latérales d’irrigation semi-permanentes ou permanentes,
par exemple,
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.