General Information

Abstract

Deals with the definitions, determinations and indication of characteristics of mammographic anti-scatter grids used in diagnostic X-ray imaging equipment, in order to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern.

Status
Replaced
Publication Date
23-Jun-1997
Drafting Committee
WG 19 - TC 62/SC 62B/WG 19
Current Stage
DELPUB - Deleted Publication
Start Date
29-Aug-2001
Completion Date
28-Aug-2026

Buy Documents

Standard

IEC 61953:1997 - Diagnostic X-ray imaging equipment - Characteristics of mammographic anti-scatter grids Released:6/24/1997

ISBN:2-8318-3878-9
English and French language (41 pages)
sale 15% off
Preview
sale 15% off
Preview

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61953:1997 - Diagnostic X-ray imaging equipment - Characteristics of mammographic anti-scatter grids Released:6/24/1997

ISBN:2-8318-3878-9
English and French language (41 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 61953:1997 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Diagnostic X-ray imaging equipment - Characteristics of mammographic anti-scatter grids". This standard covers: Deals with the definitions, determinations and indication of characteristics of mammographic anti-scatter grids used in diagnostic X-ray imaging equipment, in order to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern.

Deals with the definitions, determinations and indication of characteristics of mammographic anti-scatter grids used in diagnostic X-ray imaging equipment, in order to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern.

IEC 61953:1997 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61953:1997 has the following relationships with other standards: It is inter standard links to IEC 60627:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61953:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1997-06
Appareils d'imagerie de diagnostic
à rayonnement X –
Caractéristiques des grilles antidiffusantes
pour la mammographie
Diagnostic X-ray imaging equipment –
Characteristics of mammographic
anti-scatter grids
Numéro de référence
Reference number
CEI/IEC 61953: 1997
Validité de la présente publication Validity of this publication

Le contenu technique des publications de la CEI est The technical content of IEC publications is kept under

constamment revu par la CEI afin qu'il reflète l'état constant review by the IEC, thus ensuring that the

actuel de la technique. content reflects current technology.

Des renseignements relatifs à la date de Information relating to the date of the reconfirmation

reconfirmation de la publication sont disponibles of the publication is available from the IEC Central
auprès du Bureau Central de la CEI. Office.

Les renseignements relatifs à ces révisions, à Information on the revision work, the issue of revised

l'établissement des éditions révisées et aux editions and amendments may be obtained from IEC

amendements peuvent être obtenus auprès des National Committees and from the following IEC

Comités nationaux de la CEI et dans les documents sources:
ci-dessous:
• Bulletin de la CEI • IEC Bulletin
• Annuaire de la CEI • IEC Yearbook
Publié annuellement Published yearly
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
Terminologie Terminology
En ce qui concerne la terminologie générale, le lecteur For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire IEC 60050: International Electrotechnical Vocabulary
Electrotechnique International (VEI), qui se présente (IEV), which is issued in the form of separate chapters
sous forme de chapitres séparés traitant chacun d'un each dealing with a specific field. Full details of the
sujet défini. Des détails complets sur le VEI peuvent IEV will be supplied on request. See also the IEC
être obtenus sur demande. Voir également le Multilingual Dictionary.
dictionnaire multilingue de la CEI.
Les termes et définitions figurant dans la présente The terms and definitions contained in the present
publication ont été soit tirés du VEI, soit publi-cation have either been taken from the IEV or
spécifiquement approuvés aux fins de cette have been specifically approved for the purpose of this
publication. publication.
Symboles graphiques et littéraux Graphical and letter symbols
Pour les symboles graphiques, les symboles littéraux For graphical symbols, and letter symbols and signs
et les signes d'usage général approuvés par la CEI, le approved by the IEC for general use, readers are
lecteur consultera: referred to publications:
– IEC 60027: Letter symbols to be used in electrical
– la CEI 60027: Symboles littéraux à utiliser en
technology;
électrotechnique;
– IEC 60417: Graphical symbols for use on
– la CEI 60417: Symboles graphiques utilisables sur
equipment. Index, survey and compilation of the
le matériel. Index, relevé et compilation des feuilles
individuelles; single sheets;
Symboles graphiques pour schémas; – IEC 60617: Graphical symbols for diagrams;
– la CEI 60617:
and for medical electrical equipment,
et pour les appareils électromédicaux,
– IEC 60878: Graphical symbols for electromedical
– la CEI 60878: Symboles graphiques pour
equipment in medical practice.
équipements électriques en pratique médicale.
Les symboles et signes contenus dans la présente The symbols and signs contained in the present
publication ont été soit tirés de la CEI 60027, de la publication have either been taken from IEC 60027,
IEC 60417, IEC 60617 and/or IEC 60878, or have
CEI 60417, de la CEI 60617 et/ou de la CEI 60878,
been specifically approved for the purpose of this
soit spécifiquement approuvés aux fins de cette
publication.
publication.
Publications de la CEI établies par le IEC publications prepared by the same
même comité d'études technical committee
The attention of readers is drawn to the end pages of
L'attention du lecteur est attirée sur les listes figurant
this publication which list the IEC publications issued
à la fin de cette publication, qui énumèrent les
by the technical committee which has prepared the
publications de la CEI préparées par le comité
present publication.
d'études qui a établi la présente publication.

NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1997-06
Appareils d'imagerie de diagnostic
à rayonnement X –
Caractéristiques des grilles antidiffusantes
pour la mammographie
Diagnostic X-ray imaging equipment –
Characteristics of mammographic
anti-scatter grids
 IEC 1997 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
S
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61953 © CEI:1997
SOMMAIRE
Pages
AVANT-PROPOS. 4

INTRODUCTION. 6

Articles
1 Domaine d'application et objet . 8

2 Références normatives. 8
3 Terminologie. 10
3.1 Degré des prescriptions . 10
3.2 Utilisation des termes. 10
3.3 Termes définis. 10
4 Constitution des GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE. 14
5 Mesure et détermination des caractéristiques physiques . 14
5.1 Méthode et montage de mesure . 14
5.2 Caractéristiques physiques. 18
6 Prescriptions pour les GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE. 22
6.1 Tolérances de fabrication. 22
6.2 Détermination des LIMITES D'EMPLOI. 22
6.3 Exactitude des caractéristiques . 22
6.4 Marquages et DOCUMENTS D'ACCOMPAGNEMENT. 22
6.5 Déclaration de conformité . 24
Figures
1 Constitution des GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE . 26
ÉTECTEUR DE RAYONNEMENT
2D . 28
3 Disposition de mesure pour GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE
en CONDITIONS DE FAISCEAU ÉTROIT . 30
4 Disposition de mesure pour GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE
en CONDITIONS DE FAISCEAU LARGE . 32

Annexes
A Calcul des LIMITES D'EMPLOI . 34
B Terminologie – Index des termes définis . 36
C Bibliographie . 40

61953 © IEC:1997 – 3 –
CONTENTS
Page
FOREWORD . 5

INTRODUCTION. 7

Clause
1 Scope and object. 9

2 Normative references. 9
3 Terminology. 11
3.1 Degree of requirements . 11
3.2 Use of terms. 11
3.3 Defined terms. 11
4 Structure of MAMMOGRAPHIC ANTI-SCATTER GRIDS. 15
5 Measurement and determination of physical characteristics . 15
5.1 Method and arrangement for measurement . 15
5.2 Physical characteristics.19
6 Requirements for MAMMOGRAPHIC ANTI-SCATTER GRIDS. 23
6.1 Manufacturing tolerances. 23
6.2 Determination of the APPLICATION LIMITS . 23
6.3 Accuracy of characteristics . 23
6.4 Marking and ACCOMPANYING DOCUMENTS. 23
6.5 Statement of compliance . 25
Figures
1 Structure of MAMMOGRAPHIC ANTI-SCATTER GRIDS. 27
2RADIATION DETECTOR . 29
3 Measurement arrangement for MAMMOGRAPHIC ANTI-SCATTER GRIDS with
NARROW BEAM CONDITION
.......................................................................................................... 31
4 Measurement arrangement for MAMMOGRAPHIC ANTI-SCATTER GRIDS with

BROAD BEAM CONDITION. 33
Annexes
A Calculation of the APPLICATION LIMITS . 35
B Terminology – Index of defined terms. 37
C Bibliography. 41

– 4 – 61953 © CEI:1997
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

_________
APPAREILS D'IMAGERIE DE DIAGNOSTIC À RAYONNEMENT X –

Caractéristiques des grilles antidiffusantes pour la mammographie

AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes Internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61953 a été établie par le sous-comité 62B: Appareils d'imagerie
de diagnostic, du comité d'études 62 de la CEI: Equipements électriques dans la pratique
médicale.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
62B/297/FDIS 62B/320/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Les annexes A et B font partie intégrante de cette norme.
L'annexe C est donnée uniquement à titre d'information.
Dans la présente norme, les caractères d'imprimerie suivants sont utilisés:
– prescriptions dont la conformité peut être vérifiée par un essai et définitions: caractères romains;
– explications, conseils, notes, énoncés de portée générale, exceptions et références: petits caractères
romains;
– modalités d'essais et titres des paragraphes: caractères italiques;
– TERMES DÉFINIS DANS LA CEI 60601-1, LA CEI 60788, DANS L'ARTICLE 3 DE LA PRÉSENTE NORME
OU DANS D’AUTRES NORMES RÉFÉRENCÉES À L’ANNEXE B: PETITES CAPITALES.

61953 © IEC:1997 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
DIAGNOSTIC X-RAY IMAGING EQUIPMENT –

Characteristics of mammographic anti-scatter grids

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61953 has been prepared by subcommittee 62B: Diagnostic
imaging equipment, of IEC technical committee 62: Electrical equipment in medical practice.
The text of this standard is based on the following documents:
FDIS Report on voting
62B/297/FDIS 62B/320/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annexes A and B form an integral part of this standard.
Annex C is for information only.
In this standard, the following print types are used:
– requirements, compliance with which can be tested, and definitions: roman type;
– explanations, advice, notes, general statements, exceptions and references: smaller type;
– test specifications and headings of subclauses: italic type;
– TERMS DEFINED IN IEC 60601-1, IN IEC 60788, IN CLAUSE 3 OF THIS STANDARD OR IN OTHER IEC
STANDARDS REFERENCED IN ANNEX B: SMALL CAPITALS.

– 6 – 61953 © CEI:1997
INTRODUCTION
La mammographie à rayonnement X est un examen techniquement exigeant, dans la mesure

où il est nécessaire d'obtenir un contraste et une résolution élevés tout en limitant la dose

absorbée par le sein. Pour atteindre ces objectifs, il est nécessaire d'utiliser des rayons X de
faible énergie, un dispositif de compression, et une géométrie spécifique. En conséquence, il

est recommandé d’utiliser uniquement des ÉQUIPEMENTS À RAYONNEMENT X spécialisés. Alors

que la plupart de ces équipements comprennent une GRILLE ANTIDIFFUSANTE, les GRILLES

ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE à utiliser ne sont pas traitées dans la CEI 60627.

Les GRILLES ANTIDIFFUSANTES utilisées en radiologie générale sont traitées par la CEI 60627 et
la présente norme suit le même canevas. Lors de la rédaction de la présente norme, la
nécessité d'une révision de la CEI 60627 est apparue clairement et ce travail a débuté. Il est
prévu de fusionner ultérieurement les deux normes traitant des GRILLES ANTIDIFFUSANTES. Pour
faciliter ce travail, certains paragraphes ne sont pas utilisés dans la présente norme et des
paragraphes nouveaux ont été introduits.
Quelques-unes des différences entre la CEI 60627 et la présente norme sont indiquées ci-dessous.
– Le concept de grille de référence n'est pas retenu. On a jugé que de telles grilles
n'étaient que peu utilisées. Il devrait être suffisant de définir sans ambiguïté le DÉTECTEUR
DE RAYONNEMENT et la procédure à suivre.
– La géométrie utilisée ici simule un examen mammographique typique.
– Un seul FANT ME TRANSMISSION DU RAYONNEMENT
ô est utilisé dans les mesures de
PRIMAIRE et TRANSMISSION DU RAYONNEMENT DIFFUSÉ.
–L'ÉCRAN FLUORESCENT employé pour les mesures utilise un phosphore plus fin au tungstate
de calcium. Ce phosphore n'est pas d'usage courant en mammographie mais ce matériau est
bien défini et fournit une meilleure constance de performance entre écrans différents.
– Les LIMITES D'EMPLOI ont dû être réduites pour la mammographie.
– Les tolérances de production ont été restreintes par rapport à celles applicables aux grilles
utilisées en radiologie générale, de manière à obtenir des caractéristiques significatives et
permettant de faire la différence entre les divers types de grilles utilisées en mammo-
graphie. En conséquence, les tolérances sur les mesures ont également été restreintes.
Pour réaliser les mesures décrites, il est nécessaire de disposer de matériel de laboratoire
spécifique et de conditions de mesures soigneusement maîtrisées.

61953 © IEC:1997 – 7 –
INTRODUCTION
X-ray mammography is an examination which is technically demanding because of the need to
achieve high contrast and excellent resolution whilst limiting the absorbed dose to the female
breast. Low energy X-rays, compression and a special geometry are needed to achieve these

objectives. Therefore, only dedicated X-RAY EQUIPMENT should be used. While most of such

equipment incorporates an ANTI-SCATTER GRID, the MAMMOGRAPHIC ANTI-SCATTER GRIDS used

are not covered by IEC 60627.
ANTI-SCATTER GRIDS used in general radiology are covered by IEC 60627, and this standard

follows the same outline. During the writing of this standard, it became clear that a revision of
IEC 60627 was necessary, and work on this has started. It is intended that the two standards
covering ANTI-SCATTER GRIDS will be merged together. To facilitate this, some subclauses are
not used here and extra subclauses have been introduced.
Some of the differences between IEC 60627 and this standard are outlined below.
– The concept of a reference grid is now omitted. It was found that such grids were little
used. It should be sufficient to unambiguously define the RADIATION DETECTOR and
procedure.
– The geometry used here simulates a typical mammography examination.
– Only one PHANTOM is used for measurements of TRANSMISSION OF PRIMARY RADIATION and
TRANSMISSION OF SCATTERED RADIATION.
– The FLUORESCENT SCREEN used for the measurements employs a thinner calcium
tungstate phosphor. This is not a standard mammography phosphor, but this material is well
defined, resulting in better uniformity of performance between different screens.
– The APPLICATION LIMITS needed to be reduced for mammography.
– The production tolerances have been narrowed, compared to the grids used in general
radiology, in order to have meaningful characteristic data which allow the distinction
between different grid types used in mammography. Consequently, the measuring
tolerances have also been narrowed.
Special laboratory equipment and carefully controlled test conditions are needed for the
measurements described here.
– 8 – 61953 © CEI:1997
APPAREILS D'IMAGERIE DE DIAGNOSTIC À RAYONNEMENT X –

Caractéristiques des grilles antidiffusantes pour la mammographie

1 Domaine d'application et objet

La présente Norme internationale concerne les définitions, la détermination et l'indication des
caractéristiques des GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE destinées aux équipements
de radiodiagnostic afin de réduire l'influence sur la SURFACE RÉCEPTRICE DE L'IMAGE du RAYONNEMENT

DIFFUSÉ produit en particulier dans le corps du PATIENT, et d'améliorer ainsi le contraste de

l'IMAGE RADIOLOGIQUE POTENTIELLE.
Actuellement, seules les GRILLES ANTIDIFFUSANTES focalisées sont utilisées pour la mammo-
graphie. Le domaine d'application de la présente norme se limite donc aux GRILLES FOCALISÉES.
La présente norme ne s’applique pas aux ESSAIS D'ACCEPTATION.
La présente norme ne traite pas de l'homogénéité de performance des grilles d'un point à
l'autre de leur surface.
La présente norme n’est pas destinée à être appliquée à la détermination des caractéristiques
des GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE dans des conditions pouvant apparaître
normalement dans les installations comprenant des ÉQUIPEMENTS À RAYONNEMENT X sur le site
de l'UTILISATEUR.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de référence qui
y est faite, constituent des dispositions valables pour la présente Norme internationale. Au
moment de la publication, les éditions indiquées étaient en vigueur. Tout document normatif
est sujet à révision et les parties prenantes aux accords fondés sur la présente Norme inter-
nationale sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes des
documents normatifs indiqués ci-après. Les membres de la CEI et de l'ISO possèdent le
registre des Normes internationales en vigueur.
CEI 60417: 1973, Symboles graphiques utilisables sur le matériel. Index, relevé et compilation
des feuilles individuelles
CEI 60417N: (1995), Treizième complément
CEI 60601-1: 1988, Appareils électromédicaux – Partie 1: Règles générales de sécurité
Amendement 1 (1991)
Amendement 2 (1995)
CEI 60627: 1978, Caractéristiques des grilles antidiffusantes utilisées dans les équipements à
rayons X
CEI 60788: 1984, Radiologie médicale – Terminologie
CEI 61223-1: 1993, Essais d'évaluation et de routine dans les services d'imagerie médicale –
Partie 1: Aspects généraux
CEI 61267: 1994, Equipement de diagnostic médical à rayonnement X – Conditions de
rayonnement pour utilisation dans la détermination des caractéristiques

61953 © IEC:1997 – 9 –
DIAGNOSTIC X-RAY IMAGING EQUIPMENT –

Characteristics of mammographic anti-scatter grids

1 Scope and object
This International Standard deals with the definitions, determinations and indication of
characteristics of MAMMOGRAPHIC ANTI-SCATTER grids used in diagnostic X-ray imaging
equipment, in order to reduce the incidence of SCATTERED RADIATION, produced particularly in

the body of the PATIENT, upon the IMAGE RECEPTION area and thus to improve the contrast of

the X-RAY PATTERN.
At present only focused ANTI-SCATTER grids are used in mammography. The scope of this
standard is therefore restricted to FOCUSED GRIDS.
This standard is not intended to be applied for ACCEPTANCE TESTS.
This standard does not cover the homogeneity of performance over the area of a grid.
This standard is not intended to be applied for the determination of the characteristics of
MAMMOGRAPHIC ANTI-SCATTER GRIDS under conditions which can normally be found in
installations of X-RAY EQUIPMENT at the USER's site.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. At the time of publication, the editions
indicated were valid. All normative documents are subject to revision, and parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents listed below. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 60417: 1973, Graphical symbols for use on equipment. Index, survey and compilation of
the single sheets
IEC 60417N: (1995), Thirteenth supplement
IEC 60601-1: 1988, Medical electrical equipment – Part 1: General requirements for safety
Amendment 1 (1991)
Amendment 2 (1995)
IEC 60627: 1978, Characteristics of anti-scatter grids used in X-ray equipment
IEC 60788: 1984, Medical radiology – Terminology
IEC 61223-1: 1993, Evaluation and routine testing in medical imaging departments – Part 1:
General aspects
IEC 61267: 1994, Medical diagnostic X-ray equipment – Radiation conditions for use in the
determination of characteristics

– 10 – 61953 © CEI:1997
3 Terminologie
3.1 Degré des prescriptions
Dans la présente norme, certains termes, qui ne sont pas imprimés en PETITES MAJUSCULES,
ont un sens particulier:
– *doit+ indique que l'application d'une prescription est obligatoire pour être en

conformité avec la présente norme;

– *il convient de+ indique que l'application d'une prescription est fortement recommandée

mais n'est pas obligatoire pour être en conformité avec la présente norme;

– *peut+ indique une certaine manière de se conformer à une prescription ou
d'éviter la nécessité de s'y conformer;
– *spécifique+ est utilisé pour signaler des informations précises indiquées dans la
présente norme ou citées en référence dans d'autres normes, se rapportant
généralement à des conditions particulières de fonctionnement, des
dispositions d'essai ou des valeurs en liaison avec la conformité;
– *spécifié+ est utilisé pour signaler des informations précises données par le
CONSTRUCTEUR dans les DOCUMENTS D'ACCOMPAGNEMENT ou dans la
documentation relative à l'équipement considéré, concernant généralement
les buts recherchés ou les paramètres et les conditions associés à son
utilisation ou aux essais pour déterminer la conformité.
3.2 Utilisation des termes
Dans la présente norme, les termes imprimés en PETITES CAPITALES sont utilisés selon le sens
défini dans la CEI 60601-1, dans la CEI 60788, dans l'article 3 de la présente norme ou dans
d’autres normes référencées à l’annexe B.
3.3 Termes définis
Pour les besoins de la présente Norme internationale, les définitions suivantes s'appliquent.
NOTE – Certains des termes définis, indiqués dans la présente norme, s'écartent des termes indiqués dans
l'édition actuelle (1984) de la CEI 60788.
3.3.1 GRILLE ANTIDIFFUSANTE: Dispositif comportant une disposition périodique fixe de
matériaux ayant des propriétés différentes d'ATTÉNUATION du rayonnement X, destiné à être
placé avant la SURFACE RÉCEPTRICE DE L'IMAGE afin de réduire l'influence du RAYONNEMENT
DIFFUSÉ sur cette surface et d'augmenter ainsi le contraste sur l'IMAGE RADIOLOGIQUE POTENTIELLE.
3.3.2 GRILLE LINÉAIRE: GRILLE ANTIDIFFUSANTE composée de lames très absorbantes séparées

par des espaces très transparents et dont les axes longitudinaux sont parallèles.
3.3.3 Non utilisé.
RILLE FOCALISÉE
3.3.4 G : GRILLE LINÉAIRE telle que les plans des lames absorbantes
convergent sur une ligne droite à la DISTANCE DE FOCALISATION.
3.3.5 Non utilisé.
3.3.6 Non utilisé.
3.3.7 GRILLE FIXE: GRILLE ANTIDIFFUSANTE utilisée de telle façon qu'elle ne se déplace pas par
rapport au FAISCEAU DE RAYONNEMENT qui la traverse.

61953 © IEC:1997 – 11 –
3 Terminology
3.1 Degree of requirements
In this standard, certain terms which are not printed in SMALL CAPITALS have particular
meanings, as follows:
– "shall" indicates a requirement that is mandatory for compliance;

– "should" indicates a strong recommendation that is not mandatory for compliance;

– "may" indicates a permitted manner of complying with a requirement or of avoiding
the need to comply;
– "specific" is used to indicate definitive information stated in this standard or referenced
in other standards, usually concerning particular operating conditions, test
arrangements or values connected with compliance;
– "specified" is used to indicate definitive information stated by the MANUFACTURER in
ACCOMPANYING DOCUMENTS or in other documentation relating to the
equipment under consideration, usually concerning its intended purposes, or
the parameters or conditions associated with its use or with testing to
determine compliance.
3.2 Use of terms
In this standard, terms printed in SMALL CAPITALS are used as defined in IEC 60601-1, in
IEC 60788, in clause 3 of this standard or in other standards referenced in annex B.
3.3 Defined terms
For the purpose of this International Standard, the following definitions apply.
NOTE – Some of the defined terms given in this standard deviate from those given in the current edition (1984)
of IEC 60788.
3.3.1 ANTI-SCATTER GRID: Device with a fixed periodic arrangement of materials with different
X-ray ATTENUATION properties to be placed in front of the IMAGE RECEPTION AREA in order to
reduce the incidence of SCATTERED RADIATION
upon that area and thus increase the contrast in
the X-RAY PATTERN.
INEAR GRID
3.3.2 L : ANTI-SCATTER GRID composed of highly absorbing strips and highly
transmitting interspaces which are parallel in their longitudinal direction.

3.3.3 Not used.
3.3.4 FOCUSED GRID: LINEAR GRID in which the planes of the absorbing strips converge to a
straight line at the FOCUSING DISTANCE.
3.3.5 Not used.
3.3.6 Not used.
3.3.7 STATIONARY GRID: ANTI-SCATTER GRID used in such a way that it does not move in
relation to the RADIATION BEAM.

– 12 – 61953 © CEI:1997
3.3.8 GRILLE MOBILE: GRILLE ANTIDIFFUSANTE utilisée dans un ACCESSOIRE qui permet le
déplacement de la GRILLE ANTIDIFFUSANTE pendant l'irradiation par un FAISCEAU DE

RAYONNEMENT, de manière à éviter la formation d'une image des lames absorbantes et la perte

d'information qui en résulte.
3.3.9 GRILLE ANTIDIFFUSANTE POUR LA MAMMOGRAPHIE: GRILLE FOCALISÉE spécialement conçue

pour la mammographie.
3.3.10 Caractéristiques géométriques

–1
3.3.10.1 FRÉQUENCE DES LAMES: Symbole: N, unité: cm . Nombre de lames absorbantes par

unité de longueur d'une GRILLE LINÉAIRE.
NOTE – Ce terme remplace l'ancien terme «NOMBRE DE LAMES PAR CENTIMÈTRE».
3.3.10.2 RAPPORT DE GRILLE: Symbole: r. Rapport entre la hauteur des lames absorbantes et
la distance qui les sépare au centre d'une GRILLE LINÉAIRE.
3.3.10.3 DISTANCE DE FOCALISATION: Symbole: f , unité: cm. Distance entre la face incidente d'une
GRILLE FOCALISÉE et la ligne de convergence des plans des lames absorbantes de la grille.
NOTE – Bien noter la différence entre *DISTANCE DE FOCALISATION+, *distance entre FOYER et grille+ et *distance
entre FOYER et film+.
3.3.10.4 LIMITES D'EMPLOI: Symboles: f , f unité: cm. Limite inférieure f et limite supérieure
1 2 1
f de la distance du FOYER à la face incidente d'une GRILLE FOCALISÉE entre lesquelles on peut
généralement s'attendre à obtenir une information radiologique de qualité acceptable.
3.3.10.5 LIGNE CENTRALE VRAIE: Projection normale sur la face incidente d'une GRILLE
FOCALISÉE de la ligne de convergence des plans des lames absorbantes.
NDICATION DE LA LIGNE CENTRALE
3.3.10.6 I : Sur la face incidente d'une GRILLE FOCALISÉE,
marquage destiné à indiquer la position et l'orientation de la LIGNE CENTRALE VRAIE.
NOTE – Dans la plupart des cas ce marquage coïncide avec la ligne géométrique de la surface incidente de la grille.
3.3.11 Caractéristiques physiques
3.3.11.1 TRANSMISSION DU RAYONNEMENT PRIMAIRE: Symbole: T . Caractéristique d'un objet,
p
évaluée en tant que rapport entre la VALEUR MESURÉE de la quantité ou du débit de RAYONNEMENT
PRIMAIRE, l’objet étant interposé dans un FAISCEAU DE RAYONNEMENT, et la valeur correspondante
sans objet interposé dans le faisceau, dans des conditions spécifiques de mesurage.

3.3.11.2 TRANSMISSION DU RAYONNEMENT DIFFUSÉ: Symbole: T . Caractéristique d'un objet,
s
évaluée en tant que rapport entre la VALEUR MESURÉE de la quantité ou du débit de RAYONNEMENT
DIFFUSÉ, l’objet étant interposé dans un FAISCEAU DE RAYONNEMENT, et la valeur correspondante
sans objet interposé dans le faisceau, dans des conditions spécifiques de mesurage.
RANSMISSION DU RAYONNEMENT TOTAL
3.3.11.3 T : Symbole: T . Caractéristique d'un objet, évaluée
t
en tant que rapport entre la VALEUR MESURÉE de la quantité ou du débit de RAYONNEMENT total,
l’objet étant interposé dans un FAISCEAU DE RAYONNEMENT, et la valeur correspondante sans objet
interposé dans le faisceau, dans des conditions spécifiques de mesurage.
3.3.11.4 SÉLECTIVITÉ DE GRILLE: Symbole: ∑. Caractéristique d'une GRILLE ANTIDIFFUSANTE, évaluée
en tant que rapport de la TRANSMISSION DU RAYONNEMENT PRIMAIRE à la TRANSMISSION DU
RAYONNEMENT DIFFUSÉ.
61953 © IEC:1997 – 13 –
3.3.8 MOVING GRID: ANTI-SCATTER GRID used in an ACCESSORY that enables the ANTI-SCATTER
GRID to be moved, when irradiated by a RADIATION BEAM, in order to avoid the imaging of the

absorbing strips and the consequent loss of information.

3.3.9 MAMMOGRAPHIC ANTI-SCATTER GRID: FOCUSED GRID specially designed for

mammography.
3.3.10 Geometric characteristics

–1
3.3.10.1 STRIP FREQUENCY: Letter symbol: N, unit: cm . Number of absorbing strips per unit

length of a LINEAR GRID.
NOTE – This term replaces the previous term "STRIPS PER CENTIMETRE".
3.3.10.2 GRID RATIO: Letter symbol: r. Ratio between the height of the absorbing strips and
the distance between the absorbing strips in the centre of a LINEAR GRID.
3.3.10.3 FOCUSING DISTANCE: Letter symbol: f , unit: cm. Distance between the incident face
of a FOCUSED GRID and the line into which the planes of the absorbing strips of the grid
converge.
NOTE – Attention is drawn to the differences between "FOCUSING DISTANCE", "FOCAL SPOT to grid distance" and
"FOCAL SPOT to film distance".
3.3.10.4 APPLICATION LIMITS: Letter symbols: f , f , unit: cm. Lower, f , and upper, f , limits of
1 2 1 2
the distance from the FOCAL SPOT to the incident face of a FOCUSED GRID between which the
obtained radiological information can generally be expected to be acceptable.
3.3.10.5 TRUE CENTRAL LINE: Perpendicular projection onto the incident face of a FOCUSED
GRID of the line into which the planes of the absorbing strips converge.
3.3.10.6 CENTRAL LINE INDICATION: On the incident face of a FOCUSED GRID, marking which is
intended to indicate the position and direction of the TRUE CENTRAL LINE.
NOTE – In most cases, this marking coincides with the geometric centre line of the grid's incident face.
3.3.11 Physical characteristics
3.3.11.1 TRANSMISSION OF PRIMARY RADIATION: Letter symbol: T . Characteristic of an object,
p
evaluated as the ratio of the MEASURED VALUE of the quantity or rate of PRIMARY RADIATION with
the object placed in a RADIATION BEAM to that with the object removed from the beam, under
specific measuring conditions.

3.3.11.2 TRANSMISSION OF SCATTERED RADIATION: Letter symbol: T . Characteristic of an
s
object, evaluated as the ratio of the MEASURED VALUE of the quantity or rate of SCATTERED
RADIATION with the object placed in a RADIATION BEAM to that with the object removed from the
beam, under specific measuring conditions.
3.3.11.3 TRANSMISSION OF TOTAL RADIATION: Letter symbol: T . Characteristic of an object,
t
evaluated as the ratio of the MEASURED VALUE of the quantity or rate of total RADIATION with the
object placed in a RADIATION BEAM to that with the object removed from the beam, under
specific measuring conditions.
3.3.11.4 GRID SELECTIVITY: Letter symbol: ∑. Characteristic of an ANTI-SCATTER GRID, evaluated
as the ratio of the TRANSMISSION OF PRIMARY RADIATION to the TRANSMISSION OF SCATTERED
RADIATION.
– 14 – 61953 © CEI:1997
3.3.11.5 FACTEUR D'AMÉLIORATION DE CONTRASTE: Symbole: K. Caractéristique d'une GRILLE
ANTIDIFFUSANTE, évaluée en tant que rapport de la TRANSMISSION DU RAYONNEMENT PRIMAIRE à

la TRANSMISSION DU RAYONNEMENT TOTAL.

3.3.11.6 FACTEUR D'EXPOSITION DE GRILLE: Symbole: B. Caractéristique d'une GRILLE ANTI-

DIFFUSANTE, évaluée en tant que rapport entre la VALEUR MESURÉE de la quantité ou du débit de

RAYONNEMENT total en l'absence de GRILLE ANTIDIFFUSANTE dans un FAISCEAU DE RAYONNEMENT

et la valeur correspondante avec une GRILLE ANTIDIFFUSANTE interposée dans le faisceau, dans

des conditions spécifiques de mesurage.

3.3.12 Autres termes
ÉCENTRAGE D UNE GRILLE FOCALISÉE FOYER TUBE RADIOGÈNE
3.3.12.1 D ' : Distance entre le d'un
et le plan passant par la LIGNE CENTRALE VRAIE d'une GRILLE FOCALISÉE et perpendiculaire à la
face incidente de la grille.
3.3.12.2 DÉFOCALISATION D'UNE GRILLE FOCALISÉE: Ecart entre la distance du FOYER d'un TUBE
RADIOGÈNE et la face incidente d'une GRILLE FOCALISÉE, et la DISTANCE DE FOCALISATION de
cette grille.
4 Constitution des GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE
Les GRILLES ANTIDIFFUSANTES POUR LA MAMMOGRAPHIE doivent être des GRILLES FOCALISÉES.
Elles sont constituées de lames en matériau à haut pouvoir absorbant, d'épaisseur d et de
hauteur h, espacées à une distance régulière D les unes des autres; voir figure 1.
Habituellement, les espaces entre les lames sont remplis par un matériau à haut pouvoir de
transmission. La grille peut posséder un cadre et des enveloppes la protégeant des dommages
mécaniques, et assurant la rigidité indispensable du dispositif.
La FRÉQUENCE DES LAMES est donnée par
N =
()d + D
Le RAPPORT DE GRILLE est donné par
h
r =
D
5 Mesure et détermination des caractéristiques physiques

5.1 Méthode et montage de mesure
5.1.1 Détermination des caractéristiques physiques
Pour l'application de la présente norme, les valeurs de TRANSMISSION du RAYONNEMENT X
doivent être déterminées comme étant le rapport des deux VALEURS MESURÉES obtenues avec
le dispositif décrit en 5.1.2.
5.1.2 Dispositif de mesure
On doit utiliser un DÉTECTEUR DE RAYONNEMENT à ÉCRAN FLUORESCENT et photodétecteur;
voir figure 2. L'ÉCRAN FLUORESCENT doit être constitué de phosphore au tungstate de calcium
–2 –2
(32 mg cm ± 2 mg cm ) de préférence sans pigment.
Le diamètre du champ de mesure doit être de 6,0 mm ± 0,5 mm.

61953 © IEC:1997 – 15 –
3.3.11.5 CONTRAST IMPROVEMENT RATIO: Letter symbol: K. Characteristic of an ANTI-SCATTER
GRID, evaluated as the ratio of the TRANSMISSION OF PRIMARY RADIATION to the TRANSMISSION OF

TOTAL RADIATION.
3.3.11.6 GRID EXPOSURE FACTOR: Letter symbol: B. Characteristic of an ANTI-SCATTER GRID,

evaluated as the ratio of the MEASURED VALUE of the quantity or rate of total RADIATION without

the ANTI-SCATTER GRID in a RADIATION BEAM to that with the ANTI-SCATTER GRID placed in the

beam, under specific measuring conditions.

3.3.12 Other terms
3.3.12.1 DECENTRING OF A FOCUSED GRID: Distance from the FOCAL SPOT of an X-RAY TUBE to
the plane through the TRUE CENTRAL LINE of a FOCUSED GRID and perpendicular to the incident
face of the grid.
3.3.12.2 DEFOCUSING OF A FOCUSED GRID: Difference between the distance from the FOCAL
SPOT of an X-RAY TUBE to the incident face of a FOCUSED GRID and the FOCUSING DISTANCE of
that grid.
4 Structure of MAMMOGRAPHIC ANTI-SCATTER GRIDS
MAMMOGRAPHIC ANTI-SCATTER GRIDS shall be FOCUSED GRIDS. They consist of strips of highly
absorbing material, of thickness d and height h, arranged at a regular distance D from each
other; see figure 1.
The interspaces between the strips are usually filled with highly transmitting material. The grid
may have a frame and covers to protect against mechanical damage, and to ensure the rigidity
of the device.
The STRIP FREQUENCY is
N =
()d + D
The GRID RATIO is
h
r =
D
5 Measurement and determination of physical characteristics

5.1 Method and arrangement for measurement
5.1.1 Determinati
...