Amendment 1 - Classification of environmental conditions - Part 4-1: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Storage

Amendement 1 - Classification des conditions d'environnement - Partie 4-1: Guide pour la corrélation et la transformation des classes de conditions d'environnement de la CEI 60721-3 en essais d'environnement de la CEI 60068 - Stockage

General Information

Status
Withdrawn
Publication Date
22-May-2003
Withdrawal Date
15-Jun-2023
Current Stage
WPUB - Publication withdrawn
Completion Date
16-Jun-2023
Ref Project

Relations

Buy Standard

Technical report
IEC TR 60721-4-1:2001/AMD1:2003 - Amendment 1 - Classification of environmental conditions - Part 4-1: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Storage Released:5/23/2003 Isbn:2831869293
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview
Technical report
IEC TR 60721-4-1:2001/AMD1:2003 - Amendment 1 - Classification of environmental conditions - Part 4-1: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Storage
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


RAPPORT CEI
TECHNIQUE
IEC
TR 60721-4-1
TECHNICAL
REPORT
AMENDEMENT 1
AMENDMENT 1
2003-05
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Amendement 1
Classification des conditions d’environnement –
Partie 4-1:
Guide pour la corrélation et la transformation
des classes de conditions d’environnement
de la CEI 60721-3 en essais d’environnement
de la CEI 60068 –
Stockage
Amendment 1
Classification of environmental conditions –
Part 4-1:
Guidance for the correlation and transformation
of environmental condition classes of IEC 60721-3
to the environmental tests of IEC 60068 –

Storage
CODE PRIX
U
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – TR 60721-4-1 Amend. 1  CEI:2003

AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 104 de la CEI: Conditions,

classification et essais d'environnement.

Le texte de cet amendement est issu des documents suivants:

Projet d’enquête Rapport de vote

104/194/DTR 104/255A/RVC
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2006. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
SOMMAIRE
Ajouter le titre de la nouvelle annexe A suivante:
Annexe A Transport – Conditions climatiques
Remplacer la liste existante des tableaux par la nouvelle liste suivante:
Tableau 1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K2
Tableau 2 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K3
Tableau 3 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K4
Tableau 4 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K8
Tableau 5 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M1

Tableau 6 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M2
Tableau 7 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M3
Tableau 8 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M4
Tableau A.1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K1
Tableau A.2 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K5
Tableau A.3 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K6
Tableau A.4 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K7
Tableau A.5 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K9
Tableau A.6 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K10
Tableau A.7 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K11

TR 60721-4-1 Amend. 1  IEC:2003      – 3 –

FOREWORD
This amendment has been prepared by IEC technical committee 104: Environmental

conditions, classification and methods of test.

The text of this amendment is based on the following documents:

Enquiry draft Report on voting

104/194/DTR 104/255A/RVC
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Add the title of the following Annex A:
Annex A Transportation – Climatic conditions
Replace the existing list of tables by the following new list:
Table 1 – Recommended tests for IEC 600721-3-1 – Class 1K2
Table 2 – Recommended tests for IEC 600721-3-1 – Class 1K3
Table 3 – Recommended tests for IEC 600721-3-1 – Class 1K4
Table 4 – Recommended tests for IEC 600721-3-1 – Class 1K8

Table 5 – Recommended tests for IEC 600721-3-1 – Class 1M1
Table 6 – Recommended tests for IEC 600721-3-1 – Class 1M2
Table 7 – Recommended tests for IEC 600721-3-1 – Class 1M3
Table 8 – Recommended tests for IEC 600721-3-1 – Class 1M4
Table A.1 – Recommended tests for IEC 60721-3-1 – Class 1K1
Table A.2 – Recommended tests for IEC 60721-3-1 – Class 1K5
Table A.3 – Recommended tests for IEC 60721-3-1 – Class 1K6
Table A.4 – Recommended tests for IEC 60721-3-1 – Class 1K7
Table A.5 – Recommended tests for IEC 60721-3-1 – Class 1K9
Table A.6 – Recommended tests for IEC 60721-3-1 – Class 1K10
Table A.7 – Recommended tests for IEC 60721-3-1 – Class 1K11

– 4 – TR 60721-4-1 Amend. 1  CEI:2003

Cette page est laissée intentionnellement vierge.

TR 60721-4-1 Amend. 1  IEC:2003      – 5 –

This page is intentionally blank

– 6 – TR 60721-4-1 Amend. 1  CEI:2003

Page 38
Ajouter après le Tableau 8, la nouvelle annexe A suivante:

TR 60721-4-1 Amend. 1  IEC:2003      – 7 –

Page 39
Add after Table 8, the following new Annex A:

– 8 –     TR 60721-4-1 Amend. 1  CEI:2003

Annexe A
Transport – Conditions climatiques
Tableau A.1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K1
(stockage entièrement en air conditionné)
CEI 60721-3-1 – Conditions climatiques CEI 60068-2 – Essais climatiques
Classe Essai de la CEI 60068-2 le plus approchant Essai recommandé Note
Agent d'environnement
o
1K1 Méthode d'essai Sévérité Méthode d'essai Sévérité n
x) Chaleur sèche Aucune 1), 2)
50 60068-2-2: Bb/Bd
y) Froid Aucune 1), 2)
Chaleur sèche
Chaleur humide
60068-2-1: Ab/Ad
Température 20 15
Humidité
z) Chaleur humide Aucune 1), 2)
°C
10 absolue
60068-2-56: Cb
g/m
Froid 4
-10
-20
0 20 40 60 80 100
Humidité relative  % RH
Figure A.1 – Climatogramme – Catégorie 1K1
a) Basse température de l’air +20 °C Selon l’essai recommandé Voir ci-dessus
b) Haute température de l’air +25 °C Selon l’essai recommandé Voir ci-dessus
c) Faible humidité relative 20 % Selon l’essai recommandé Voir ci-dessus
d) Forte humidité relative 75 % Selon l’essai recommandé Voir ci-dessus
e) Faible humidité absolue 4 g/m Selon l’essai recommandé Voir ci-dessus
f) Forte humidité absolue 15 g/m Selon l’essai recommandé Voir ci-dessus
g) Variation rapide de la température 0,1 °C/min 60068-2-14: Nb +5 °C jusqu’à température Essai normalement non requis - Voir note 3) 3)
ambiante, 2 cycles
1 °C/min t = 3 h
h) Basse pression atmosphérique 70 kPa 60068-2-13: M 70 kPa, 30 min Essai normalement non requis - Voir note 4) 4)
i) Haute pression atmosphérique 106 kPa Pas d’essai de la CEI 60068-2 Essai normalement non requis - Voir note 5) 5)
j) Rayonnement solaire 500 W/m² 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Essai normalement non requis - Voir note 6) 6)
Procédure C
a
k) Rayonnement de chaleur Non
l) Mouvement de l’air environnant 0,5 m/s Pas d’essai de la CEI 60068-2 Essai normalement non requis - Voir note 7) 7)
a
m) Condensation Non
a
n) Précipitations (pluie, neige, grêle, etc.) Non
a
o) Intensité de la pluie Non
a
p) Basse température de la pluie Non
a
q) Eau d’autre origine que la pluie Non
a
r) Formation de glace ou de gelées Non
a
«Non» dans la colonne catégorie signifie qu’il n’y a pas de condition spécifiée dans la CEI 60721-3-1.

TR 60721-4-1 Amend. 1  CEI:2003       – 9 –

Notes explicatives pour le Tableau A.1 – Catégorie 1K1
1) Un climatogramme est donné pour information, uniquement pour décrire les 5) Il n’y a pas de méthode d’essai dans la CEI 60068-2 pour cette
conditions climatiques et le choix d’essais associé. La CEI 60721-3-1 ne contient pas condition qui est comprise dans la gamme standard des conditions
un tel climatogramme. Pour l’essai de matériels quant aux conditions du atmosphériques telles qu’elles sont définies dans la CEI 60068-1, et
climatogramme, seuls trois essais sont normalement utilisés: par conséquent cette condition est considérée comme peu
contraignante pour la plupart des matériels. Il n'est pas recommandé
− Essai de chaleur sèche pour lequel l’humidité relative ne doit pas dépasser 50
d'essai.
% mais n’est pas particulièrement contrôlée.
6) La procédure d’essai C de la CEI 60068-2-5 destinée à simuler les
− Essai au froid pour lequel l’humidité n’est pas contrôlée.
effets du rayonnement solaire au niveau du sol est choisie car elle
produit un rayonnement continu permettant l’évaluation des effets de
− Essai continu de chaleur humide pour lequel à la fois la température et
photo dégradation. Même si la sévérité de cette catégorie est de
l’humidité sont contrôlées.
500 W/m , la seule condition d’essai contenue dans la CEI 60068-2-
Ces essais sont les essais x, y et z du Tableau A.1. Les autres conditions limites du
5:Sa est une valeur de 1 120 W/m pour le rayonnement solaire.
climatogramme ne sont pas requises et il n’existe pas d’essai adapté dans la CEI
Les essais d’exposition solaire ne sont pas considérés comme
60068-2.
satisfaisants car il est difficile de reproduire le rayonnement réel
2) Ces conditions de température élevée, basse et d'humidité sont contenues dans les
constaté dans la pratique. Il est recommandé que cette condition soit
conditions atmosphériques standard telles qu'elles sont décrites dans la CEI 60068-1
évaluée en augmentant la température de l’essai de chaleur sèche et
et par conséquent il n'est pas recommandé d'essai.
en évaluant les matériaux et les composants par rapport aux
réactions photochimiques. Pour plus d’informations, voir la CEI
3) Les gammes de températures dans cette catégorie sont considérées se trouver à
60721-4-0. Cependant comme la sévérité du rayonnement solaire
l'intérieur des conditions atmosphériques standard telles qu'elles sont décrites dans la
pour cette catégorie est uniquement de 500 W/m², il est recommandé
CEI 60068-1 et il n'est pas recommandé d'essai de variation de température.
de ne pas faire d'essai supplémentaire de température.
4) Pour des matériels hermétiquement fermés ou pour des matériels contenant ou
7) Il n'est pas recommandé d'essai. Il n’existe pas d’essai adapté dans
traitant des liquides, l’essai M de la CEI 60068-2-13 est recommandé. Pour des
la CEI 60068-2 et la condition est considérée comme peu
applications normales dans lesquelles l’effet de la pression atmosphérique est évalué
contraignante pour la plupart des matériels.
au niveau du composant, il n'est pas recommandé d'essai.

– 10 –     TR 60721-4-1 Amend. 1  IEC:2003

Annex A
Transportation – Climatic conditions
Table A.1 – Recommended tests for IEC 60721-3-1 – Class 1K1
(fully air conditioned storage)
IEC 60721-3-1 – Climatic conditions IEC 60068-2 – Climatic tests
Nearest IEC 60068-2 Recommended test
Class Note
Environmental parameter
1K1 no.
Test method Severity Test method Severity
x) Dry heat None 1), 2)
60068-2-2:
40 Bb/Bd
Dry heat
Damp heat
y) Cold
None 1), 2)
Temperature 20 15
60068-2-1:
Absolute
°C
10 humidity
Ab/Ad
Cold 4
g/m
None 1), 2)
z) Damp heat
-10
60068-2-56: Cb
-20
0 20 40 60 80 100
Relative humidity  % RH
Figure A.1 – Class 1K1 – Climatogram
a) Low air temperature +20 °C As recommended test See above
b) High air temperature +25 °C As recommended test See above
c) Low relative humidity 20 % As recommended test See above
d) High relative humidity 75 % As recommended test See above
e) Low absolute humidity 4 g/m As recommended test See above
f) High absolute humidity 15 g/m As recommended test See above
g) Rate of change of temperature 0,1 °C/min 60068-2-14Nb +5 °C to ambient, 2 cycles Test normally not required -See note 3) 3)
1°C/min  t = 3 h
h) Low air pressure 70 kPa 60068-2-13: M 70 kPa, 30 min Test normally not required -See note 4) 4)
i) High air pressure 106 kPa No IEC 60068-2 test Test normally not required -See note 5) 5)
j) Solar radiation 500 W/m² 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Test normally not required -See note 6) 6)
Procedure C
a
k) Heat radiation No
l) Movement of surrounding air 0,5 m/s No IEC 60068-2 test Test normally not required -See note 7) 7)
a
m) Condensation No
a
n) Precipitation (rain, snow, hail, etc.) No
a
o) Rain intensity No
a
p) Low rain temperature No
a
q) Water from sources other than rain No
a
r) Formation of ice and frost No
a
“No” in the class column means that no IEC 60721-3-1 condition is specified.

TR 60721-4-1 Amend. 1  IEC:2003       – 11 –

Explanatory notes for Table A.1 – Class 1K1
1) A climatogram is shown for information only in order to describe the climatic 4) For sealed equipment or for equipment containing/processing liquids, test M of
conditions and associated choice of test. IEC 60721-3-1 does not contain such IEC 60068-2-13 is recommended. For normal applications where the effect of
a climatogram. For testing equipment against the conditions of the climatogram, air pressure is evaluated at the component level, no test is recommended.
only three tests are normally used:
5) There is no IEC 60068-2 test method for this condition, which is within the
standard range of atmospheric conditions as defined in IEC 60068-1 and is
− Dry heat test, where the relative humidity shall not exceed 50 % but is not
specifically controlled. therefore considered benign for most equipment. No test is recommended.
6) The IEC 60068-2-5 procedure C test for simulating the effects of solar radiation
− Cold test, where humidity is not controlled.
at ground level is chosen since it produces continuous irradiation thus allowing
− Damp heat test steady state, where both temperature and humidity are
assessment of photodegradation effects. Although the severity of this class is
controlled.
500 W/m², the only test condition contained in IEC 60068-2-5:Sa is for a solar
radiation value of 1 120 W/m²-
These are shown as tests x, y and z in Table A.1. Other boundary conditions of
the climatogram are not required to be tested and there are no suitable
Solar tests are not considered satisfactory, since it is difficult to replicate the
IEC 60068-2 tests available.
actual radiation experienced in practice. It is recommended that this condition
should be evaluated by increasing the temperature of the dry heat test and
2) These high temperature, low temperature and humidity conditions are within the
evaluating materials and components for photochemical reactions. For more
standard atmos
...


RAPPORT CEI
TECHNIQUE
IEC
TR 60721-4-1
TECHNICAL
REPORT
AMENDEMENT 1
AMENDMENT 1
2003-05
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Amendement 1
Classification des conditions d’environnement –
Partie 4-1:
Guide pour la corrélation et la transformation
des classes de conditions d’environnement
de la CEI 60721-3 en essais d’environnement
de la CEI 60068 –
Stockage
Amendment 1
Classification of environmental conditions –
Part 4-1:
Guidance for the correlation and transformation
of environmental condition classes of IEC 60721-3
to the environmental tests of IEC 60068 –
Storage
CODE PRIX
U
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – TR 60721-4-1 Amend. 1  CEI:2003
AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 104 de la CEI: Conditions,
classification et essais d'environnement.
Le texte de cet amendement est issu des documents suivants:
Projet d’enquête Rapport de vote
104/194/DTR 104/255A/RVC
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2006. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
SOMMAIRE
Ajouter le titre de la nouvelle annexe A suivante:
Annexe A Transport – Conditions climatiques
Remplacer la liste existante des tableaux par la nouvelle liste suivante:
Tableau 1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K2
Tableau 2 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K3
Tableau 3 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K4
Tableau 4 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K8
Tableau 5 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M1
Tableau 6 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M2
Tableau 7 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M3
Tableau 8 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1M4
Tableau A.1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K1
Tableau A.2 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K5
Tableau A.3 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K6
Tableau A.4 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K7
Tableau A.5 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K9
Tableau A.6 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K10
Tableau A.7 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K11

TR 60721-4-1 Amend. 1  IEC:2003      – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 104: Environmental
conditions, classification and methods of test.
The text of this amendment is based on the following documents:
Enquiry draft Report on voting
104/194/DTR 104/255A/RVC
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Add the title of the following Annex A:
Annex A Transportation – Climatic conditions
Replace the existing list of tables by the following new list:
Table 1 – Recommended tests for IEC 600721-3-1 – Class 1K2
Table 2 – Recommended tests for IEC 600721-3-1 – Class 1K3
Table 3 – Recommended tests for IEC 600721-3-1 – Class 1K4
Table 4 – Recommended tests for IEC 600721-3-1 – Class 1K8
Table 5 – Recommended tests for IEC 600721-3-1 – Class 1M1
Table 6 – Recommended tests for IEC 600721-3-1 – Class 1M2
Table 7 – Recommended tests for IEC 600721-3-1 – Class 1M3
Table 8 – Recommended tests for IEC 600721-3-1 – Class 1M4
Table A.1 – Recommended tests for IEC 60721-3-1 – Class 1K1
Table A.2 – Recommended tests for IEC 60721-3-1 – Class 1K5
Table A.3 – Recommended tests for IEC 60721-3-1 – Class 1K6
Table A.4 – Recommended tests for IEC 60721-3-1 – Class 1K7
Table A.5 – Recommended tests for IEC 60721-3-1 – Class 1K9
Table A.6 – Recommended tests for IEC 60721-3-1 – Class 1K10
Table A.7 – Recommended tests for IEC 60721-3-1 – Class 1K11

– 4 – TR 60721-4-1 Amend. 1  CEI:2003
Cette page est laissée intentionnellement vierge.

TR 60721-4-1 Amend. 1  IEC:2003      – 5 –
This page is intentionally blank

– 6 – TR 60721-4-1 Amend. 1  CEI:2003
Page 38
Ajouter après le Tableau 8, la nouvelle annexe A suivante:

TR 60721-4-1 Amend. 1  IEC:2003      – 7 –
Page 39
Add after Table 8, the following new Annex A:

– 8 –     TR 60721-4-1 Amend. 1  CEI:2003
Annexe A
Transport – Conditions climatiques
Tableau A.1 – Essais recommandés pour la CEI 60721-3-1 – Catégorie 1K1
(stockage entièrement en air conditionné)
CEI 60721-3-1 – Conditions climatiques CEI 60068-2 – Essais climatiques
Classe Essai de la CEI 60068-2 le plus approchant Essai recommandé Note
Agent d'environnement
o
1K1 Méthode d'essai Sévérité Méthode d'essai Sévérité n
x) Chaleur sèche Aucune 1), 2)
50 60068-2-2: Bb/Bd
y) Froid Aucune 1), 2)
Chaleur sèche
Chaleur humide
60068-2-1: Ab/Ad
Température 20 15
Humidité
z) Chaleur humide Aucune 1), 2)
°C
10 absolue
60068-2-56: Cb
g/m
Froid 4
-10
-20
0 20 40 60 80 100
Humidité relative  % RH
Figure A.1 – Climatogramme – Catégorie 1K1
a) Basse température de l’air +20 °C Selon l’essai recommandé Voir ci-dessus
b) Haute température de l’air +25 °C Selon l’essai recommandé Voir ci-dessus
c) Faible humidité relative 20 % Selon l’essai recommandé Voir ci-dessus
d) Forte humidité relative 75 % Selon l’essai recommandé Voir ci-dessus
e) Faible humidité absolue 4 g/m Selon l’essai recommandé Voir ci-dessus
f) Forte humidité absolue 15 g/m Selon l’essai recommandé Voir ci-dessus
g) Variation rapide de la température 0,1 °C/min 60068-2-14: Nb +5 °C jusqu’à température Essai normalement non requis - Voir note 3) 3)
ambiante, 2 cycles
1 °C/min t = 3 h
h) Basse pression atmosphérique 70 kPa 60068-2-13: M 70 kPa, 30 min Essai normalement non requis - Voir note 4) 4)
i) Haute pression atmosphérique 106 kPa Pas d’essai de la CEI 60068-2 Essai normalement non requis - Voir note 5) 5)
j) Rayonnement solaire 500 W/m² 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Essai normalement non requis - Voir note 6) 6)
Procédure C
a
k) Rayonnement de chaleur Non
l) Mouvement de l’air environnant 0,5 m/s Pas d’essai de la CEI 60068-2 Essai normalement non requis - Voir note 7) 7)
a
m) Condensation Non
a
n) Précipitations (pluie, neige, grêle, etc.) Non
a
o) Intensité de la pluie Non
a
p) Basse température de la pluie Non
a
q) Eau d’autre origine que la pluie Non
a
r) Formation de glace ou de gelées Non
a
«Non» dans la colonne catégorie signifie qu’il n’y a pas de condition spécifiée dans la CEI 60721-3-1.

TR 60721-4-1 Amend. 1  CEI:2003       – 9 –
Notes explicatives pour le Tableau A.1 – Catégorie 1K1
1) Un climatogramme est donné pour information, uniquement pour décrire les 5) Il n’y a pas de méthode d’essai dans la CEI 60068-2 pour cette
conditions climatiques et le choix d’essais associé. La CEI 60721-3-1 ne contient pas condition qui est comprise dans la gamme standard des conditions
un tel climatogramme. Pour l’essai de matériels quant aux conditions du atmosphériques telles qu’elles sont définies dans la CEI 60068-1, et
climatogramme, seuls trois essais sont normalement utilisés: par conséquent cette condition est considérée comme peu
contraignante pour la plupart des matériels. Il n'est pas recommandé
− Essai de chaleur sèche pour lequel l’humidité relative ne doit pas dépasser 50
d'essai.
% mais n’est pas particulièrement contrôlée.
6) La procédure d’essai C de la CEI 60068-2-5 destinée à simuler les
− Essai au froid pour lequel l’humidité n’est pas contrôlée.
effets du rayonnement solaire au niveau du sol est choisie car elle
produit un rayonnement continu permettant l’évaluation des effets de
− Essai continu de chaleur humide pour lequel à la fois la température et
photo dégradation. Même si la sévérité de cette catégorie est de
l’humidité sont contrôlées.
500 W/m , la seule condition d’essai contenue dans la CEI 60068-2-
Ces essais sont les essais x, y et z du Tableau A.1. Les autres conditions limites du
5:Sa est une valeur de 1 120 W/m pour le rayonnement solaire.
climatogramme ne sont pas requises et il n’existe pas d’essai adapté dans la CEI
Les essais d’exposition solaire ne sont pas considérés comme
60068-2.
satisfaisants car il est difficile de reproduire le rayonnement réel
2) Ces conditions de température élevée, basse et d'humidité sont contenues dans les
constaté dans la pratique. Il est recommandé que cette condition soit
conditions atmosphériques standard telles qu'elles sont décrites dans la CEI 60068-1
évaluée en augmentant la température de l’essai de chaleur sèche et
et par conséquent il n'est pas recommandé d'essai.
en évaluant les matériaux et les composants par rapport aux
réactions photochimiques. Pour plus d’informations, voir la CEI
3) Les gammes de températures dans cette catégorie sont considérées se trouver à
60721-4-0. Cependant comme la sévérité du rayonnement solaire
l'intérieur des conditions atmosphériques standard telles qu'elles sont décrites dans la
pour cette catégorie est uniquement de 500 W/m², il est recommandé
CEI 60068-1 et il n'est pas recommandé d'essai de variation de température.
de ne pas faire d'essai supplémentaire de température.
4) Pour des matériels hermétiquement fermés ou pour des matériels contenant ou
7) Il n'est pas recommandé d'essai. Il n’existe pas d’essai adapté dans
traitant des liquides, l’essai M de la CEI 60068-2-13 est recommandé. Pour des
la CEI 60068-2 et la condition est considérée comme peu
applications normales dans lesquelles l’effet de la pression atmosphérique est évalué
contraignante pour la plupart des matériels.
au niveau du composant, il n'est pas recommandé d'essai.

– 10 –     TR 60721-4-1 Amend. 1  IEC:2003
Annex A
Transportation – Climatic conditions
Table A.1 – Recommended tests for IEC 60721-3-1 – Class 1K1
(fully air conditioned storage)
IEC 60721-3-1 – Climatic conditions IEC 60068-2 – Climatic tests
Nearest IEC 60068-2 Recommended test
Class Note
Environmental parameter
1K1 no.
Test method Severity Test method Severity
x) Dry heat None 1), 2)
60068-2-2:
40 Bb/Bd
Dry heat
Damp heat
y) Cold
None 1), 2)
Temperature 20 15
60068-2-1:
Absolute
°C
10 humidity
Ab/Ad
Cold 4
g/m
None 1), 2)
z) Damp heat
-10
60068-2-56: Cb
-20
0 20 40 60 80 100
Relative humidity  % RH
Figure A.1 – Class 1K1 – Climatogram
a) Low air temperature +20 °C As recommended test See above
b) High air temperature +25 °C As recommended test See above
c) Low relative humidity 20 % As recommended test See above
d) High relative humidity 75 % As recommended test See above
e) Low absolute humidity 4 g/m As recommended test See above
f) High absolute humidity 15 g/m As recommended test See above
g) Rate of change of temperature 0,1 °C/min 60068-2-14Nb +5 °C to ambient, 2 cycles Test normally not required -See note 3) 3)
1°C/min  t = 3 h
h) Low air pressure 70 kPa 60068-2-13: M 70 kPa, 30 min Test normally not required -See note 4) 4)
i) High air pressure 106 kPa No IEC 60068-2 test Test normally not required -See note 5) 5)
j) Solar radiation 500 W/m² 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Test normally not required -See note 6) 6)
Procedure C
a
k) Heat radiation No
l) Movement of surrounding air 0,5 m/s No IEC 60068-2 test Test normally not required -See note 7) 7)
a
m) Condensation No
a
n) Precipitation (rain, snow, hail, etc.) No
a
o) Rain intensity No
a
p) Low rain temperature No
a
q) Water from sources other than rain No
a
r) Formation of ice and frost No
a
“No” in the class column means that no IEC 60721-3-1 condition is specified.

TR 60721-4-1 Amend. 1  IEC:2003       – 11 –
Explanatory notes for Table A.1 – Class 1K1
1) A climatogram is shown for information only in order to describe the climatic 4) For sealed equipment or for equipment containing/processing liquids, test M of
conditions and associated choice of test. IEC 60721-3-1 does not contain such IEC 60068-2-13 is recommended. For normal applications where the effect of
a climatogram. For testing equipment against the conditions of the climatogram, air pressure is evaluated at the component level, no test is recommended.
only three tests are normally used:
5) There is no IEC 60068-2 test method for this condition, which is within the
standard range of atmospheric conditions as defined in IEC 60068-1 and is
− Dry heat test, where the relative humidity shall not exceed 50 % but is not
specifically controlled. therefore considered benign for most equipment. No test is recommended.
6) The IEC 60068-2-5 procedure C test for simulating the effects of solar radiation
− Cold test, where humidity is not controlled.
at ground level is chosen since it produces continuous irradiation thus allowing
− Damp heat test steady state, where both temperature and humidity are
assessment of photodegradation effects. Although the severity of this class is
controlled.
500 W/m², the only test condition contained in IEC 60068-2-5:Sa is for a solar
radiation value of 1 120 W/m²-
These are shown as tests x, y and z in Table A.1. Other boundary conditions of
the climatogram are not required to be tested and there are no suitable
Solar tests are not considered satisfactory, since it is difficult to replicate the
IEC 60068-2 tests available.
actual radiation experienced in practice. It is recommended that this condition
should be evaluated by increasing the temperature of the dry heat test and
2) These high temperature, low temperature and humidity conditions are within the
evaluating materials and components for photochemical reactions. For more
standard atmospheric conditions as described in IEC 60068-1 and therefore no
information see IEC 60721-4-0. However since the severity of solar radiation in
test is recommended.
this class is only 500 W/m², it is recommended that no additional temperat
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.