IEC 60400:1999/AMD2:2004
(Amendment)Amendment 2 - Lampholders for tubular fluorescent lamps and starterholders
Amendment 2 - Lampholders for tubular fluorescent lamps and starterholders
Amendement 2 - Douilles pour lampes tubulaires à fluorescence et douilles pour starters
General Information
- Status
- Published
- Publication Date
- 06-Oct-2004
- Technical Committee
- SC 34B - Lamp caps and holders
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 15-Jul-2008
- Completion Date
- 26-Oct-2025
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Overview
IEC 60400:1999/AMD2:2004 is the Amendment 2 standard focused on lampholders for tubular fluorescent lamps and starterholders, issued by the International Electrotechnical Commission (IEC). This amendment updates the original IEC 60400:1999 standard to specify classifications, definitions, test methods, and requirements relevant to lampholders used in fluorescent lighting systems. It provides important enhancements to ensure reliable performance, safety, and interchangeability of fluorescent lamp components.
Key updates include defining impulse withstand categories, clarifying the scope of lampholders intended for luminaire manufacturers only, modifying creepage and clearance distances, and refining test procedures for endurance and electrical safety. The document is essential for manufacturers, testing laboratories, and product designers involved with fluorescent lighting components, ensuring compliance with international safety and performance criteria.
Key Topics
Impulse Withstand Categories
The amendment introduces and elaborates on impulse withstand categories (I, II, III, IV), which classify lampholders based on their ability to withstand transient overvoltages. This classification helps coordinate insulation across electrical installations to reduce risks of failure and enhance continuity of service:- Category I: Equipment connected to fixed building installations with external protection.
- Category II: Equipment connected to fixed installations without additional external protection.
- Category III: Equipment forming part of fixed installations requiring higher availability.
- Category IV: Equipment near the origin of electrical installations upstream of main distribution.
Definitions Clarification
New terms such as primary circuit and secondary circuit have been added to clarify power connection distinctions relevant for safety and testing purposes.Scope and Usage Restrictions
The amendment specifies that lampholders intended exclusively for luminaire manufacturers' use are not for retail sale, helping control product application and quality.Testing and Endurance Requirements
Updates are given to type testing procedures, endurance tests, and references to related IEC testing standards, reinforcing rigorous evaluation methods for product durability and safety.Creepage Distances and Clearances
Revised minimum values for creepage distances and clearances applicable to impulse withstand category II are detailed, along with guidelines on using insulation materials according to Proof Tracking Index (PTI). These ensure lampholders maintain proper insulation distances to prevent electrical tracking and surface discharge under working voltages.Marking Requirements
Lampholders must have markings indicating their rated impulse withstand category, facilitating clear catalog and user information for safe deployment.
Applications
IEC 60400:1999/AMD2:2004 applies to the design, manufacture, and testing of lampholders and starterholders for tubular fluorescent lamps used in residential, commercial, and industrial lighting fixtures. The standard is indispensable for:
- Lamp and luminaire manufacturers, ensuring parts meet international safety and performance benchmarks.
- Quality assurance and compliance testing laboratories, for conducting standardized type tests.
- Electrical installers and engineers, in selecting and verifying compatible and safe components for lighting systems.
- Product certification bodies, to assess conformity and maintain consistency in fluorescent lamp-related equipment.
By adhering to this amendment, stakeholders can ensure fluorescent lighting solutions provide reliable operation, enhanced safety against electrical faults, and compliance with global best practices on insulation coordination and overvoltage protection.
Related Standards
IEC 60061-4: Lamp Caps and Holders – Part 4: Guidelines and General Information
Provides further guidance on conformity testing during manufacturing, complementing the type tests specified in IEC 60400 amendments.IEC 60664-1: Insulation Coordination for Equipment Within Low-Voltage Systems
Used to determine insulation requirements and impulse withstand categories critical for lampholder design.IEC 60598-1: Luminaires – General Requirements and Tests
Includes provisions on creepage distances and clearances that relate to lampholder safety and performance.IEC 60112: Method for the Determination of the Proof Tracking Index (PTI)
Basis for classifying insulation materials used in lampholder construction concerning resistance to tracking.IEC 60695-2-11: Fire Hazard Testing – Glow-wire Test for Electrical Equipment
Relevant for flammability and thermal endurance testing of lampholder components.
By complying with IEC 60400:1999/AMD2:2004, manufacturers and users of tubular fluorescent lamp holders can ensure enhanced safety, robust performance under electrical stress, and meet harmonized international standards essential in the global lighting industry.
Frequently Asked Questions
IEC 60400:1999/AMD2:2004 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Amendment 2 - Lampholders for tubular fluorescent lamps and starterholders". This standard covers: Amendment 2 - Lampholders for tubular fluorescent lamps and starterholders
Amendment 2 - Lampholders for tubular fluorescent lamps and starterholders
IEC 60400:1999/AMD2:2004 is classified under the following ICS (International Classification for Standards) categories: 29.140.10 - Lamp caps and holders. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60400:1999/AMD2:2004 has the following relationships with other standards: It is inter standard links to IEC 60400:1999, IEC 60400:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC 60400:1999/AMD2:2004 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2004-10
Amendement 2
Douilles pour lampes tubulaires à fluorescence
et douilles pour starters
Amendment 2
Lampholders for tubular fluorescent lamps
and starterholders
IEC 2004 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
J
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60400 Amend.2 CEI:2004
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34B: Culots et douilles, du comité
d'études 34 de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34B/1154/FDIS 34B/1173/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
Page 10
1 Généralités
1.1 Domaine d’application
Remplacer la dernière phrase du cinquième alinéa par la suivante:
Les douilles destinées à être utilisées par les fabricants de luminaires exclusivement ne sont
pas destinées à la vente au détail.
Page 12
2 Définitions
Ajouter, après la définition 2.15, à la page 16, les nouvelles définitions suivantes:
2.16
catégorie de tenue aux chocs
chiffre définissant une condition de surtension transitoire
60400 Amend.2 IEC:2004 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 34B: Lamp caps and holders, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34B/1154/FDIS 34B/1173/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 11
1 General
1.1 Scope
Replace the last sentence of the fifth paragraph by the following:
Lampholders for use by luminaire manufacturers only are not for retail sale.
Page 13
2 Definitions
Add, after definition 2.15, on page 17, the following new definitions:
2.16
impulse withstand categorie
a numeral defining a transient overvoltage condition
– 4 – 60400 Amend.2 CEI:2004
NOTE Les catégories de tenue aux chocs I, II, III et IV sont utilisées.
a) But de la classification des catégories de tenue aux chocs
Les catégories de tenue aux chocs servent à différencier les différents degrés de validité des équipements en ce
qui concerne les attentes requises en matière de continuité de service et de tolérance des risques de défauts.
En sélectionnant les niveaux de tenue aux chocs des équipements, on peut réaliser la coordination de l’isolement
pour l’installation complète en réduisant le risque de défaut à un niveau acceptable qui servira de base dans la
maîtrise de la surtension.
Un chiffre plus élevé désignant la catégorie de tenue aux chocs indique une tenue aux chocs de l’équipement plus
élevée et permet un plus grand choix de méthodes pour la maîtrise de la surtension.
Le concept de catégorie de tenue aux chocs est utilisé pour les équipements directement alimentés par le réseau.
b) Description des catégories de tenue aux chocs
Un équipement de catégorie de tenue aux chocs I est un équipement destiné a être connecté à l’installation fixe
des bâtiments. Des moyens de protection sont pris à l’extérieur de l’équipement – soit dans l’installation fixe soit
entre l’installation fixe et l’équipement – pour limiter les surtensions transitoires à un niveau donné.
Un équipement de catégorie de tenue aux chocs II est un équipement destiné a être connecté à l’installation fixe
des bâtiments.
Un équipement de catégorie de tenue aux chocs III est un équipement qui constitue une partie de l’installation fixe
et des autres équipements dont le degré de validité attendu est plus élevé.
Un équipement de catégorie de tenue aux chocs IV est destiné à être utilisé à proximité ou dans les installations
électriques des bâtiments en amont du tableau de distribution.
2.17
circuit primaire
circuit directement connecté au réseau alternatif. Il comporte, par exemple, les moyens de
connexion au réseau alternatif, les enroulements primaires des transformateurs, moteurs et
autres dispositifs en charge
2.18
circuit secondaire
circuit qui n’a pas de connexion directe avec le circuit primaire en tirant sa puissance d’un
transformateur, convertisseur ou système d’isolation équivalent, ou d’un accumulateur
Exception: les autotransformateurs. Bien qu'ayant une connexion directe avec le circuit
primaire, leur partie connectée est également considérée comme un circuit secondaire au
sens de la présente définition.
NOTE Les régimes transitoires dans de tels circuits sont amortis par l’enroulement primaire correspondant. Les
ballasts inductifs réduisent également la valeur de la tension des régimes transitoires. En conséquence, les
composants situés après un circuit primaire ou après un ballast inductif peuvent être adaptés à une catégorie de
tenue aux chocs un niveau plus bas, c’est à dire une catégorie de tenue aux chocs II.
Page 16
4.1 Les essais mentionnés dans la présente norme sont des essais de type.
Ajouter, à la fin de la note, ce qui suit:.
1)
Pour plus amples informations, voir la CEI 60061-4 (l’insertion de lignes directrices sur les essais de conformité
en cours de fabrication est actuellement en préparation).
———————
1)
CEI 60061-4: Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et de la
sécurité – Partie 4: Guide et information générale
60400 Amend.2 IEC:2004 – 5 –
NOTE Impulse withstand categories I, II, III and IV are used.
a) Purpose of classification of impulse withstand categories
Impulse withstand categories are to distinguish different degrees of availability of equipment with regard to
required expectations on continuity of service and on an acceptable risk of failure.
By selection of impulse withstand levels of equipment, insulation co-ordination can be achieved in the whole
installation, reducing the risk of failure to an acceptable level providing a basis for overvoltage control.
A higher characteristic numeral of an impulse withstand category indicates a higher specific impulse withstand of
the equipment and offers a wider choice of methods for overvoltage control.
The concept of impulse withstand categories is used for equipment energized directly from the mains.
b) Description of impulse withstand categories
Equipment of impulse withstand category I is equipment which is intended to be connected to the fixed electrical
installations of buildings. Protective means are taken outside the equipment - either in the fixed installation or
between the fixed installation and the equipment - to limit transient overvoltages to the specific level.
Equipment of impulse withstand category II is equipment to be connected to the fixed electrical installations of
buildings.
Equipment of impulse withstand category III is equipment which is part of the fixed electrical installations and other
equipment where a higher degree of availability is expected.
Equipment of impulse withstand category IV is for use at or in the proximity of the origin of the electrical
installations of buildings upstream of the main distribution board.
2.17
primary circuit
a circuit which is directly connected to the AC mains supply. It includes, for example, the
means for connection to the AC mains supply, the primary windings of transformers, motors
and other loading devices.
2.18
secondary circuit
a circuit which has no direct connection to a primary circuit and derives its power from a
transformer, converter or equivalent isolation device, or from a battery.
Exception: autotransformers. Although having direct connection to a primary circuit, the
tapped part of them is also deemed to be a secondary circuit in the above sense.
NOTE Mains transients in such a circuit are attenuated by the corresponding primary windings. Also, inductive
ballasts reduce the mains transient voltage height. Therefore, components located after a primary circuit or after an
inductive ballast can be suited for an impulse withstand category of one step lower, i.e. for impulse withstand
category II.
Page 17
4.1 Tests according to this standard are type tests.
Add at the end of the note the following wording:
1)
For further information see IEC 60061-4 (inclusion of guidance on conformity testing during manufacture is in
preparation).
———————
1)
IEC 60061-4: Lamp caps and holders together with gauges for the control of interchangeability and safety –
Part 4: Guidelines and general information
– 6 – 60400 Amend.2 CEI:2004
Page 20
7 Marques et indications
Ajouter, à la page 22, le nouvel alinéa suivant à la fin de 7.2:
Pour les douilles selon la présente norme, les distances correspondant à la catégorie de
tenue aux chocs II sont normalement applicables. Cette information doit figurer dans le
catalogue du fabricant ou autre endroit similaire.
Page 24
8.1
Modifier, au deuxième alinéa, la référence à la figure 39 pour lire «figure 41».
Page 26
8.2
Modifier, au troisième, quatrième, cinquième et septième tirets, les références à la figure 39
pour lire «figure 41».
Page 32
10.3.1
La correction ne concerne que le texte anglais.
Page 44
13 Endurance
Remplacer, dans le quatrième alinéa, les termes «figures correspondantes 14 à 29» par les
termes «figures 6, 14 à 29, 39 et 40».
Page 54
16 Lignes de fuite et distances dans l’air
Remplacer, à la page 56, le Tableau 3a par la note et le tableau suivants:
NOTE Les tensions indiquées dans le Tableau 3a sont des tensions opérationnelles et non des tensions
d’amorçage.
60400 Amend.2 IEC:2004 – 7 –
Page 21
7 Marking
Add, on page 23, the following new paragraph at the end of 7.2:
For lampholders according to this standard, the distances for impulse withstand category II
are applicable. This information has to be indicated in the manufacturer's catalogue or the
like.
Page 25
8.1 Amend, in the second paragraph, the reference to figure 39 to read “figure 41“.
Page 27
8.2 Amend, in the third, fourth, fifth and seventh dashed items, the references to figure 39 to
read “figure 41”.
Page 33
10.3.1
Replace, in the first paragraph, the term “single gauge” by the term “single-ended gauge”.
Page 45
13 Endurance
Replace, in the the fourth paragraph, the phrase “figures 14 to 29” by the phrase “figures 6,
14 to 29, 39 and 40”.
Page 55
16 Creepage distances and clearances
Replace, on page 57, Table 3a by the following note and table:
NOTE The voltages shown in Table 3a are working voltages, not ignition voltages.
– 8 – 60400 Amend.2 CEI:2004
Table 3a – Distances minimales pour les tensions sinusoïdales (50 Hz/60 Hz) −−
−−
Catégorie de résistance aux chocs II
Tensions opérationnelles
Distances
V
mm
...