Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment

Corrigendum 1 - Essais d'évaluation et de routine dans les services d'imagerie médicale - Partie 3-5: Essais d'acceptation - Performance d'imagerie des équipements de tomodensitométrie à rayonnement X

General Information

Status
Published
Publication Date
23-Mar-2006
Current Stage
DELPUB - Deleted Publication
Start Date
16-Sep-2019
Completion Date
14-Feb-2026

Relations

Effective Date
05-Sep-2023
Effective Date
05-Sep-2023
Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61223-3-5:2004/COR1:2006 - Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment Released:3/24/2006

English and French language (10 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 61223-3-5:2004/COR1:2006 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment". This standard covers: Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment

Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment

IEC 61223-3-5:2004/COR1:2006 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61223-3-5:2004/COR1:2006 has the following relationships with other standards: It is inter standard links to IEC 61223-3-5:2004, IEC 61223-3-5:2019/COR1:2022, IEC 61223-3-5:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61223-3-5:2004/COR1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


CEI 61223-3-5 IEC 61223-3-5
(Première édition – 2004) (First edition – 2004)

Essais d'évaluation et de routine dans les Evaluation and routine testing in medical

services d'imagerie médicale – imaging departments –

Partie 3-5: Essais d'acceptation - Part 3-5: Acceptance tests – Imaging

Performance d'imagerie des équipements performance of computed tomography
de tomodensitométrie à rayonnement X X-ray equipment

CORRIGENDUM 1
Page 56 Page 57
F.4 Evaluation des données avec le F.4 Data evaluation with the alternate
DISPOSITIF D'ESSAI alternatif «mire à TEST DEVICE “bar pattern”
barres parallèles»
Remplacer l’équation existante: Replace the existing equation:
M −N M −N
M
π M pattern background
mire fond π
o
o
FTM = = ×
MTF = = ×
M CT −CT
M CT −CT
i matériau eau i 2
material water
par la nouvelle équation suivante:
with the following new equation:
2 2
2 2
M −N −
M
...

Questions, Comments and Discussion