Abstract

IEC 60747-5-18:2026 specifies the measuring methods of macro photoluminescence (PL) for red, green, and blue epitaxial wafers of micro light emitting diodes (LEDs) prior to chip fabrication processes. Wafer sizes being considered are 4 in, 6 in, and 8 in in diameter.

Status
Published
Publication Date
10-Jun-2026
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
11-Jun-2026
Due Date
10-Jul-2026
Completion Date
10-Jul-2026

Buy Documents

Standard

IEC 60747-5-18:2026 - Semiconductor devices - Part 5-18: Optoelectronic devices - Light emitting diodes - Test method of the macro photoluminescence for epitaxial wafers of micro light emitting diodes

ISBN:978-2-8327-1304-4
Release Date:11-Jun-2026
English language (17 pages)
sale 15% off
Preview
sale 15% off
Preview

IEC 60747-5-18:2026 is an International Standard from IEC for measuring macro photoluminescence (PL) on red, green, and blue epitaxial wafers of micro light emitting diodes (LEDs) before chip fabrication. It gives a test method for inspecting and screening wafer quality on 4 in, 6 in, and 8 in wafers, so process engineers, quality managers, and test labs can use a common wafer-level measurement approach.

What does IEC 60747-5-18:2026 specify?

IEC 60747-5-18:2026 specifies the measuring methods for macro PL of micro LED epitaxial wafers. The method is intended for wafer inspection before chip fabrication, and the scope is limited to the wafer sizes named in the document.

The document is organized into five clauses:

  • Clause 1 - Scope
  • Clause 2 - Normative references
  • Clause 3 - Terms, definitions and abbreviated terms
  • Clause 4 - Measuring methods
  • Clause 5 - Test

It also includes one informative annex and a bibliography.

AnnexWhat it covers
Annex AInformative test example, including sample conditions and example distributions across a blue LED wafer

What are the key requirements of IEC 60747-5-18:2026?

Measurement conditions

IEC 60747-5-18:2026 sets the default environmental conditions for the measurement. If no other conditions are specified, measurements are made at (25 ± 3) °C, in natural convection, and at 25 % RH to 75 % RH.

The standard also says the sample wafer should be fixed by vacuum or mechanical clamping, and the measurement should be done in a dark box. In practice, this means the result should reflect the wafer and not movement, heat drift, or ambient light.

Excitation source, scan and optics

IEC 60747-5-18:2026 uses an excitation radiation source, typically a laser, to pump carriers in the active region. The laser spot should be smaller than the stage step, and the chosen radiant power should give a clear PL signal without saturating the CCD detector.

The document recommends an xy-stage or an rθ-stage for mapping the wafer, with a typical scan step of 2 mm. It also gives recommended edge exclusions of 2 mm for 4 in wafers, 3 mm for 6 in wafers, and 4 mm for 8 in wafers. For the reader, that means the scan plan must balance coverage, detail, and test time.

Filtering and spectral measurement

IEC 60747-5-18:2026 requires a long-wavelength-pass filter to block scattered laser light before the spectrometer. The filter should have sufficient transmittance optical density, and the spectral PL signal should be checked to confirm that only PL, not laser scatter, is measured.

The spectrometer measures the spectral PL signal, usually with a CCD detector. Clause 4.3.2.6 says the spectral resolution used for the measurement shall be included in the test report, which matters because resolution affects peak position, width, and mapping results.

Test items and report

IEC 60747-5-18:2026 says the test should include peak PL signal, peak PL wavelength, centroid wavelength, FWHM of the PL signal, integrated PL signal, and the arithmetic mean and standard deviation of the measured quantities.

Clause 5.3 and Table 1 define the report content. The report should record the wafer maker, wafer size, edge exclusion, laser wavelength, radiant power, spot size, scanning step, spectral resolution, the PL results, and the ambient temperature and humidity. In practice, this gives enough information to compare runs and repeat the same setup later.

What terms does IEC 60747-5-18:2026 define?

  • Photoluminescence (PL) signal - the optical radiation emitted by the sample through photoluminescence.
  • Spectral PL signal - the PL signal measured per unit wavelength by a spectrometer.
  • Peak PL signal - the maximum value of the spectral PL signal.
  • Integrated PL signal - the spectral PL signal integrated over wavelength between the chosen limits.
  • Centroid wavelength - the wavelength corresponding to the mean photon energy of the spectrum.
  • Full width at half maximum (FWHM) - the wavelength range over which the selected characteristic stays above half its maximum value.
  • Edge exclusion - the distance from the wafer edge where no measurement is taken.
  • Charge-coupled device (CCD) - the detector typically used in the spectrometer to capture the spectral signal.

Who uses IEC 60747-5-18:2026?

IEC 60747-5-18:2026 is used by micro LED wafer manufacturers, process engineers, test laboratories, and quality teams that need to inspect epitaxial wafers before chip fabrication. It is also relevant to equipment suppliers setting up laser, stage, filter, and spectrometer systems for wafer mapping. Buyers can use it to compare what a test system measures and whether it matches wafer-level PL screening needs.

Which standards are used with IEC 60747-5-18:2026?

Clause 2 states that IEC 60747-5-18:2026 has no normative references. For spectral measurement details, Clause 4.3.2.6 points readers to CIE 250:2022, and the definition of FWHM cites IEC 60050-731:1991.

What does the IEC 60747-5-18:2026 document contain?

The document includes a short explanation of the PL process in semiconductors, a schematic measurement setup, and an example PL spectrum for a blue LED wafer. It also gives the measurement sequence from scan setup through data storage, result calculation, and report generation.

Annex A is an informative worked example with a blue micro LED wafer, test conditions, and wafer-wide distributions for peak PL signal, peak PL wavelength, centroid wavelength, FWHM, and integrated PL signal. Table 1 gives the report items, and Figure 4 shows the scan sequence used during testing.

Buy Documents

Standard

IEC 60747-5-18:2026 - Semiconductor devices - Part 5-18: Optoelectronic devices - Light emitting diodes - Test method of the macro photoluminescence for epitaxial wafers of micro light emitting diodes

ISBN:978-2-8327-1304-4
Release Date:11-Jun-2026
English language (17 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 60747-5-18:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Semiconductor devices - Part 5-18: Optoelectronic devices - Light emitting diodes - Test method of the macro photoluminescence for epitaxial wafers of micro light emitting diodes". This standard covers: IEC 60747-5-18:2026 specifies the measuring methods of macro photoluminescence (PL) for red, green, and blue epitaxial wafers of micro light emitting diodes (LEDs) prior to chip fabrication processes. Wafer sizes being considered are 4 in, 6 in, and 8 in in diameter.

IEC 60747-5-18:2026 specifies the measuring methods of macro photoluminescence (PL) for red, green, and blue epitaxial wafers of micro light emitting diodes (LEDs) prior to chip fabrication processes. Wafer sizes being considered are 4 in, 6 in, and 8 in in diameter.

IEC 60747-5-18:2026 is classified under the following ICS (International Classification for Standards) categories: 31.080.99 - Other semiconductor devices. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60747-5-18:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviated terms
  • 3.1 Terms and definitions
  • 3.1.1 PL signal
  • 3.1.2 spectral PL signal
  • 3.1.3 peak PL signal
  • 3.1.4 threshold
  • 3.1.5 minimum wavelength limit
  • 3.1.6 maximum wavelength limit
  • 3.1.7 peak PL wavelength
  • 3.1.8 integrated PL signal
  • 3.1.9 centroid wavelength
  • 3.1.10 full width at half maximum
  • 3.1.11 edge exclusion
  • 3.1.12 active region
  • 3.1.13 transmittance optical density
  • 3.2 Abbreviated terms
  • 4 Measuring methods
  • 4.1 General
  • 4.2 Principle
  • 4.3 Requirements
  • 4.4 Measurement setup
  • 5 Test
  • 5.1 Test items
  • 5.2 Test sequence
  • 5.3 Test report
  • Annex A
  • Bibliography

1 Scope

This part of IEC 60747-5 specifies the measuring methods of macro photoluminescence (PL) for red, green, and blue epitaxial wafers of micro light emitting diodes (LEDs) prior to chip fabrication processes. Wafer sizes being considered are 4 in, 6 in, and 8 in in diameter.

2 Normative references

There are no normative references in this document.

3 Terms, definitions and abbreviated terms

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1 Terms and definitions

3.1.1 PL signal

optical radiation emitted from the sample via photoluminescence Note 1 to entry: PL signal is proportional to the radiant power.

3.1.2 spectral PL signal

dΦλ() PL Φλ()= PL,λ dλ PL signal measured by a spectrometer per unit wavelength Note 1 to entry: The unit for the spectral PL signal is arb. unit/nm. Note 2 to entry: Spectral PL signal is proportional to the spectral radiant power.

3.1.3 peak PL signal

maximum value of the spectral PL signal

3.1.4 threshold

minimum spectral PL signal over which the integrated PL signal is evaluated

3.1.5 minimum wavelength limit

λ min lower limit of the integration in calculating the integrated PL signal

3.1.6 maximum wavelength limit

λ max upper limit of the integration in calculating the integrated PL signal

3.1.7 peak PL wavelength

λ

p wavelength at which the spectral PL signal is the maximum

3.1.8 integrated PL signal

Φ PL spectral PL signal integrated over the wavelength λ max Φ = Φ ()λdλ

PL PL,λ

λ min Note 1 to entry: The minimum and maximum wavelengths are recommended to be smaller and greater than the peak PL wavelength by 40 nm.

Note 2 to entry: A threshold value, 2 % of the peak PL signal, is recommended to remove the noise signal before the integration.

Note 3 to entry: The unit for the integrated PL signal is arb. unit.

3.1.9 centroid wavelength

λ

wavelength at which the mean photon energy of the spectrum is specified [1] λΦ ()λdλ PL,λ

λ =

Φ PL Note 1 to entry: For integration, the criteria of the upper/lower limits and the threshold value are the same as the integrated PL signal.

hc Note 2 to entry: The mean photon energy is related to the centroid wavelength as , where is the hv hv= h λ

Φ e hν= Planck constant and c is the speed of light in vacuum. The mean photon energy is defined by λ Φ dλ e,λ

hc in IEC 60747-5-8:2019, where Φ is the radiant power and Φ is the spectral distribution (spectral radiant e e,λ power). The mean photon energy has a meaning of the radiant power divided by the total number of photons emitted by the LED per unit time.

3.1.10 full width at half maximum

FWHM range of a variable over which a given characteristic is greater than 50 % of its maximum value Note 1 to entry: FWHM may be applied to characteristics such as radiation patterns, spectral linewidths, etc. and the variable may be wavelength, spatial or angular properties, etc., as appropriate. [SOURCE: IEC 60050-731:1991 [3], 731-01-57]

3.1.11 edge exclusion

distance from the edge of the wafer where no measurement is conducted

3.1.12 active region

region of the LED where LED radiation is emitted

3.1.13 transmittance optical density

D τ logarithm to base 10 of the reciprocal of the transmittance τ D =−log τ τ 10 Note 1 to entry: The transmittance optical density has unit one. Note 2 to entry: This entry was numbered 845-04-66 in IEC 60050-845:1987. [SOURCE: IEC 60050-845:2020, 845-24-072, modified – the accepted terms “optical density, transmittance density and decadic absorbance have been deleted, and “D ” has been added as τ a preferred term.]

3.2 Abbreviated terms

CCD charge-coupled device FWHM full width at half maximum LED light emitting diode PC personal computer PL photoluminescence

4 Measuring methods

4.1 General

The macro photoluminescence (PL) is a tool to check the optical characteristics of the micro LED epitaxial wafer. The measurement items from the macro PL on the LED wafer are discussed in 4.3 in more detail. By employing the macro PL on the wafer, the LED wafers can be inspected and screened before the full chip fabrication processes begin.

4.2 Principle

PL in a semiconductor occurs by the following processes:

a) optical pumping of electrons from the valence band to the conduction band; b) subsequent generation of electrons in the conduction band and holes in the valence band; c) very fast relaxations of created charge carriers in each band to the respective band edge; and d) generation of photons by radiative recombinations of electrons and holes. Figure 1 schematically illustrates the process of the PL:

1) optical pumping by an excitation radiation source such as a laser; 2) generation of an electron and hole pair; 3) relaxation to the respective band edge; and 4) generation of the PL signal by recombination of the electron and hole pair. In general, the energy of the pumping laser, hν , where h is the Planck constant and ν is the L L frequency of the pumping laser, is larger than the energy of the PL signal, hν , where ν is PL PL the frequency of the PL signal, i.e., hν >hν . Due to the distribution of charge carriers in each L PL band, the PL signal has a broad spectrum, reflecting the material and optical properties of the active region. From the PL signal and its mapping over the wafer, various test items are obtained, which can be used to quantify the quality of the micro LED wafer.

Key E minimum energy of the conduction band

E maximum energy of the valence band

Figure 1 – Schematic illustration of the PL processes in semiconductors

4.3 Requirements

4.3.1 Measuring conditions

a) Temperature If not specified, measurements shall be made at an ambient (T ) of (25 ± 3) °C in a condition a of natural convection.

b) Humidity When humidity condition is not specified, relative humidity shall be between 25 %RH and 75 %RH.

...