IEC 60068-2-6:1995
(Main)Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)
Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)
Gives a method of test which provides a standard procedure to determine the ability of components, equipment and other articles to withstand specified severities of sinusoidal vibration. Has the status of a basic safety publication in accordance with IEC Guide 104. The contents of the corrigendum of March 1995 have been included in this copy.
Essais d'environnement - Partie 2: Essais - Essai Fc: Vibrations (sinusoïdales)
Fournit une méthode d'essai qui donne des règles d'exécution normalisées pour déterminer l'aptitude des composants, matériels et autres articles, à résister à des sévérités spécifiées de vibrations sinusoïdales. A le statut d'une publication fondamentale de sécurité conformément au Guide 104. Le contenu du corrigendum de mars 1995 a été pris en considération dans cet exemplaire.
General Information
- Status
- Published
- Publication Date
- 30-Mar-1995
- Technical Committee
- TC 104 - Environmental conditions, classification and methods of test
- Drafting Committee
- MT 17 - TC 104/MT 17
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 13-Dec-2007
- Completion Date
- 13-Feb-2026
Relations
- Referred By
EN 60747-15:2004 - Discrete semiconductor devices - Part 15: Isolated power semiconductor devices - Effective Date
- 10-Feb-2026
- Effective Date
- 10-Feb-2026
- Referred By
EN 54-5:2000 - Fire detection and fire alarm systems - Part 5: Heat detectors - Point detectors - Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Referred By
EN 54-10:2002 - Fire detection and fire alarm systems - Part 10: Flame detectors - Point detectors - Effective Date
- 09-Feb-2026
- Revised
IEC 60068-2-6:2007 - Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) - Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Q Techna d.o.o.
NDT and quality assurance specialist. 30+ years experience. NDT personnel certification per ISO 9712, nuclear and thermal power plant inspections, QA/
Sponsored listings
Frequently Asked Questions
IEC 60068-2-6:1995 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)". This standard covers: Gives a method of test which provides a standard procedure to determine the ability of components, equipment and other articles to withstand specified severities of sinusoidal vibration. Has the status of a basic safety publication in accordance with IEC Guide 104. The contents of the corrigendum of March 1995 have been included in this copy.
Gives a method of test which provides a standard procedure to determine the ability of components, equipment and other articles to withstand specified severities of sinusoidal vibration. Has the status of a basic safety publication in accordance with IEC Guide 104. The contents of the corrigendum of March 1995 have been included in this copy.
IEC 60068-2-6:1995 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60068-2-6:1995 has the following relationships with other standards: It is inter standard links to EN 60747-15:2004, EN 50130-5:1998, EN 54-5:2000, EN 54-11:2001, CEN/TS 14507-1:2003, EN 1760-1:1997+A1:2009, EN 54-7:2000, EN 54-10:2002, IEC 60068-2-6:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60068-2-6:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Publication 68-2-6 de la CEI
(Sixième édition - 1995)
ESSAIS D’ENVIRONNEMENT –
Partie 2: Essais –
Essai Fc: Vibrations (sinusoïdales)
C O R R I G E N D U M 1
Page 32
Remplacer le premier alinéa de l’article 8 par les cinq nouveaux alinéas suivants:
8 Epreuve
La spécification particulière doit indiquer le nombre d’axes suivant lesquels on doit faire vibrer
le spécimen, ainsi que leurs positions respectives. En l’absence de telles précisions, on doit
faire vibrer le spécimen successivement selon trois axes perpendiculaires entre eux et qu’il
convient de choisir de telle sorte que les défaillances puissent être mises en évidence.
Le signal de pilotage doit provenir des signaux aux points de vérification et être utilisé pour
faire soit du pilotage à partir d’un seul point, soit du pilotage à partir de plusieurs points (voir
paragraphe A.4.5).
La spécification particulière doit choisir la procédure d’essai à appliquer parmi les phases
données ci-après. Un guide est donné dans l’annexe A. En général, les phases de l’essai
doivent être exécutées à la suite l’une de l’autre suivant un même axe et reprises ensuite pour
les autres axes (voir l’article A.3).
Des dispositions particulières sont à prendre quand un spécimen normalement destiné à être
utilisé avec isolateurs de vibrations, doit être essayé sans ceux-ci (voir l’article A.5).
Lorsque la spécification particulière le prescrit, on doit ajouter au contrôle de l’amplitude de
vibration spécifiée une limite maximale de la force de pilotage appliquée à la table vibrante. La
méthode de limitation de la force doit être précisée dans la spécification particulière (voir
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...