EN 50122-2:1998
(Main)Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems
Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems
This standard specifies requirements for protective provisions against the effects of stray currents which result from the operation of d.c. traction systems. As experience for several decades has not shown evident corrosion effects from a.c. traction systems and actual investigations are not completed, this standard only deals with stray currents flowing from a d.c. traction system. This standard applies to all metallic fixed installations which form part of the traction system, and also to any other unrelated metallic components located in any position in the earth, which may carry stray currents resulting from the operation of the railway system. This standard applies to all new electrification of a d.c. railway system. The principles may also be applied to existing electrified systems where it is necessary to consider the effects of stray currents. 94
Bahnanwendungen - Ortsfeste Anlagen - Teil 2: Schutzmaßnahmen gegen die Auswirkungen von Streuströmen, verursacht durch Gleichstrombahnen
Applications ferroviaires - Installations fixes - Partie 2: Mesures de protection contre les effets des courants vagabonds issus de la traction électrique à courant continu
Železniške naprave – Stabilne naprave električne vleke – 2. del: Zaščitni ukrepi proti učinkom blodečih tokov, ki jih povzročajo enosmerni vlečni sistemi
General Information
- Status
- Withdrawn
- Publication Date
- 06-May-1998
- Withdrawal Date
- 28-Feb-1999
- Technical Committee
- CLC/TC 9X - Electrical and electronic applications for railways
- Drafting Committee
- CLC/SC 9XC - Electric supply and earthing systems for public transport equipment and ancillary apparatus (fixed i
- Parallel Committee
- IEC/TC 9 - IEC_TC_9
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Oct-2013
- Completion Date
- 01-Oct-2013
Relations
- Effective Date
- 07-Jun-2022
- Effective Date
- 29-Jan-2023
- Effective Date
- 08-Oct-2013
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.

Bureau Veritas Railway Certification
Railway and transportation certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
Sponsored listings
Frequently Asked Questions
EN 50122-2:1998 is a standard published by CLC. Its full title is "Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems". This standard covers: This standard specifies requirements for protective provisions against the effects of stray currents which result from the operation of d.c. traction systems. As experience for several decades has not shown evident corrosion effects from a.c. traction systems and actual investigations are not completed, this standard only deals with stray currents flowing from a d.c. traction system. This standard applies to all metallic fixed installations which form part of the traction system, and also to any other unrelated metallic components located in any position in the earth, which may carry stray currents resulting from the operation of the railway system. This standard applies to all new electrification of a d.c. railway system. The principles may also be applied to existing electrified systems where it is necessary to consider the effects of stray currents. 94
This standard specifies requirements for protective provisions against the effects of stray currents which result from the operation of d.c. traction systems. As experience for several decades has not shown evident corrosion effects from a.c. traction systems and actual investigations are not completed, this standard only deals with stray currents flowing from a d.c. traction system. This standard applies to all metallic fixed installations which form part of the traction system, and also to any other unrelated metallic components located in any position in the earth, which may carry stray currents resulting from the operation of the railway system. This standard applies to all new electrification of a d.c. railway system. The principles may also be applied to existing electrified systems where it is necessary to consider the effects of stray currents. 94
EN 50122-2:1998 is classified under the following ICS (International Classification for Standards) categories: 29.120.50 - Fuses and other overcurrent protection devices; 45.020 - Railway engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50122-2:1998 has the following relationships with other standards: It is inter standard links to EN 50122-2:2010, EN 50122-2:1998/A1:2002, EN 50122-2:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50122-2:1998 is associated with the following European legislation: Standardization Mandates: M/024. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 50122-2:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VLVWHPLBahnanwendungen - Ortsfeste Anlagen -- Teil 2: Schutzmaßnahmen gegen die Auswirkungen von Streuströmen, verursacht durch GleichstrombahnenApplications ferroviaires - Installations fixes -- Partie 2: Mesures de protection contre les effets des courants vagabonds issus de la traction électrique à courant continuRailway applications - Fixed installations -- Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems29.280Electric traction equipment13.260Protection against electric shock. Live workingICS:Ta slovenski standard je istoveten z:EN 50122
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...