EN 60702-1:2002
(Main)Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
Applies to mineral insulated general wiring cables with copper or copper alloy sheath and copper conductors and with rated voltages of 500 V and 750 V. Provision is made for a corrosion-resistant extruded outer covering over the copper sheath, when required. This outer covering is not specified for the purpose of electrical insulation of the metal sheath. Requirements for terminations for use with these cables are specified in EN 60702-2. The purpose of this standard is to specify mineral insulated cables that are safe and reliable when properly used, to state the manufacturing requirements and characteristics to achieve this, and to specify methods for checking conformity with those requirements.
Mineralisolierte Leitungen mit einer Nennspannung bis 750 V - Teil 1: Leitungen
Câbles à isolant minéral et leurs terminaisons de tension assignée ne dépassant pas 750 V - Partie 1: Câbles
S'applique aux câbles à isolant minéral pour usage général, ayant une gaine en cuivre ou en alliage de cuivre et des âmes conductrices en cuivre, de tensions assignées 500 V et 750 V. Elle précise les dispositions qui s'appliquent au revêtement externe en matériau extrudé résistant à la corrosion recouvrant la gaine en cuivre, lorsque cela est exigé. Ce revêtement externe n'est pas destiné à assurer l'isolation électrique de la gaine métallique. Les exigences pour les terminaisons à utiliser avec ces câbles sont spécifiées dans la EN 60702-2. L'objet de la présente norme est de déterminer les règles auxquelles doivent répondre les câbles à isolant minéral afin qu'ils soient sûrs et fiables lorsqu'ils sont correctement utilisés, de fixer dans ce but leurs caractéristiques et les prescriptions relatives à leur fabrication, et de préciser les méthodes pour la vérification de la conformité à ces prescriptions.
Kabli z mineralno izolacijo in njihovi priključki z naznačeno napetostjo, ki ne presega 750 V - 1. del: Kabli
General Information
- Status
- Published
- Publication Date
- 07-Mar-2002
- Withdrawal Date
- 28-Feb-2005
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- IEC/TC 20 - IEC_TC_20
- Parallel Committee
- IEC/TC 20 - IEC_TC_20
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 08-Mar-2002
- Completion Date
- 08-Mar-2002
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Overview
EN 60702-1:2002 is the CLC/CENELEC European adoption of IEC 60702-1:2002 for mineral insulated cables used in general wiring with rated voltages up to 750 V. The standard applies specifically to mineral insulated cables with copper or copper-alloy sheaths and copper conductors, covering rated voltages of 500 V and 750 V. Its purpose is to define manufacturing requirements, performance characteristics and conformity checking methods so that these cables are safe and reliable in normal use. (Cable terminations are addressed in EN 60702-2.)
Key topics and requirements
- Scope and construction: Requirements for mineral insulated general wiring cables with copper conductors and copper/copper-alloy sheaths; provision for an optional corrosion-resistant extruded outer covering over the copper sheath (not intended as electrical insulation).
- Voltage ratings: Covers designs for 500 V and 750 V applications (rated voltage not exceeding 750 V).
- Manufacturing and characteristics: Specifies production criteria and key characteristics that ensure mechanical, electrical and environmental performance (materials, conductor dimensions, sheath integrity).
- Conformity assessment: Defines methods for testing and checking conformity with the specified manufacturing and performance requirements to confirm safety and reliability.
- Referenced test areas: Normative references in the standard link to established tests for conductor dimensions and materials, fire performance and circuit integrity, smoke density, and gas corrosivity, reflecting concerns for fire behaviour and material properties in installation environments.
Applications and who uses it
EN 60702-1 targets professionals involved in design, manufacture, testing and procurement of mineral insulated wiring:
- Cable manufacturers producing mineral insulated general wiring cables with copper sheaths and conductors.
- Electrical designers and specification engineers selecting cables for building services, industrial plants and safety-critical installations where mineral insulation properties are required.
- Installers and contractors who need to verify that supplied cables conform to European requirements.
- Testing laboratories and conformity assessors performing the tests and verifications referenced in the standard.
- Fire safety and maintenance engineers concerned with cable behaviour under fire conditions, smoke emission and gas corrosivity.
Related standards
- EN 60702-2:2002 - Terminations for use with these mineral insulated cables.
- Referenced IEC/EN documents cover conductor standards, cable fire tests (circuit integrity, single cable flame tests), smoke and gas corrosivity tests and common material test methods (see normative references in EN 60702-1).
This standard is essential when specifying or validating mineral insulated cables for low-voltage wiring up to 750 V, ensuring consistent manufacturing practice and verified performance for safe installations.
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
CESI Beijing Certification (Saisi)
Subsidiary of China Electronics Standardization Institute (CESI), established 1963.
Sponsored listings
Frequently Asked Questions
EN 60702-1:2002 is a standard published by CLC. Its full title is "Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables". This standard covers: Applies to mineral insulated general wiring cables with copper or copper alloy sheath and copper conductors and with rated voltages of 500 V and 750 V. Provision is made for a corrosion-resistant extruded outer covering over the copper sheath, when required. This outer covering is not specified for the purpose of electrical insulation of the metal sheath. Requirements for terminations for use with these cables are specified in EN 60702-2. The purpose of this standard is to specify mineral insulated cables that are safe and reliable when properly used, to state the manufacturing requirements and characteristics to achieve this, and to specify methods for checking conformity with those requirements.
Applies to mineral insulated general wiring cables with copper or copper alloy sheath and copper conductors and with rated voltages of 500 V and 750 V. Provision is made for a corrosion-resistant extruded outer covering over the copper sheath, when required. This outer covering is not specified for the purpose of electrical insulation of the metal sheath. Requirements for terminations for use with these cables are specified in EN 60702-2. The purpose of this standard is to specify mineral insulated cables that are safe and reliable when properly used, to state the manufacturing requirements and characteristics to achieve this, and to specify methods for checking conformity with those requirements.
EN 60702-1:2002 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60702-1:2002 has the following relationships with other standards: It is inter standard links to HD 586.1 S1:1994, EN 60702-1:2002/A1:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60702-1:2002 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 2014/53/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 60702-1:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2002
1DGRPHãþD
SIST HD 586.1 S1:1998
.DEOL]PLQHUDOQRL]RODFLMRLQQMLKRYLSULNOMXþNL]QD]QDþHQRQDSHWRVWMRNLQH
SUHVHJD9GHO.DEOL
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V
- Part 1: Cables
Mineralisolierte Leitungen mit einer Bemessungsspannung bis 750 V - Teil 1: Leitungen
Câbles à isolant minéral et leurs terminaisons de tension assignée ne dépassant pas
750 V - Partie 1: Câbles
Ta slovenski standard je istoveten z: EN 60702-1:2002
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60702-1
NORME EUROPÉENNE
EUROPÄISCHE NORM March 2002
ICS 29.060.20 Supersedes HD 586.1 S1:1994
English version
Mineral insulated cables and their terminations
with a rated voltage not exceeding 750 V
Part 1: Cables
(IEC 60702-1:2002)
Câbles à isolant minéral et leurs Mineralisolierte Leitungen mit einer
terminaisons de tension assignée Bemessungsspannung bis 750 V
ne dépassant pas 750 V Teil 1: Leitungen
Partie 1: Câbles (IEC 60702-1:2002)
(CEI 60702-1:2002)
This European Standard was approved by CENELEC on 2002-03-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60702-1:2002 E
Foreword
The text of document 20/490/FDIS, future edition 3 of IEC 60702-1, prepared by IEC TC 20, Electric
cables, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60702-1 on 2002-03-01.
This European Standard supersedes HD 586.1 S1:1994.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2005-03-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annex ZA is normative.
Annex ZA has been added by CENE
...