HD 586.1 S1:1994
(Main)Mineral insulated cables with a rated voltage not exceeding 750 V - Part 1: Cables
Mineral insulated cables with a rated voltage not exceeding 750 V - Part 1: Cables
This standard applies to mineral insulated general wiring cables with copper sheath and copper conductors with rated voltages up to 750 V. Provision is made for a corrosion resistant outer covering over the sheath, when required. This outer covering is not specified for the purposes of electrical insulation of the metal sheath.
Mineralisolierte Leitungen mit einer Nennspannung bis 750 V - Teil 1: Leitungen
Câbles à isolant minéral, de tension assignée ne dépassant pas 750 V - Partie 1: Câbles
Mineral insulated cables with a rated voltage not exceeding 750 V - Part 1: Cables
General Information
- Status
- Withdrawn
- Publication Date
- 30-Jan-1994
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- IEC/TC 20 - IEC_TC_20
- Parallel Committee
- IEC/TC 20 - IEC_TC_20
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Mar-2005
- Completion Date
- 01-Mar-2005
Relations
- Effective Date
- 29-Jan-2023
Frequently Asked Questions
HD 586.1 S1:1994 is a standardization document published by CLC. Its full title is "Mineral insulated cables with a rated voltage not exceeding 750 V - Part 1: Cables". This standard covers: This standard applies to mineral insulated general wiring cables with copper sheath and copper conductors with rated voltages up to 750 V. Provision is made for a corrosion resistant outer covering over the sheath, when required. This outer covering is not specified for the purposes of electrical insulation of the metal sheath.
This standard applies to mineral insulated general wiring cables with copper sheath and copper conductors with rated voltages up to 750 V. Provision is made for a corrosion resistant outer covering over the sheath, when required. This outer covering is not specified for the purposes of electrical insulation of the metal sheath.
HD 586.1 S1:1994 has the following relationships with other standards: It is inter standard links to EN 60702-1:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
HD 586.1 S1:1994 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
HD 586.1 S1:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-1998
Mineral insulated cables with a rated voltage not exceeding 750 V - Part 1: Cables
Mineral insulated cables with a rated voltage not exceeding 750 V -- Part 1: Cables
Mineralisolierte Leitungen mit einer Nennspannung bis 750 V -- Teil 1: Leitungen
Câbles à isolant minéral, de tension assignée ne dépassant pas 750 V -- Partie 1:
Câbles
Ta slovenski standard je istoveten z: HD 586.1 S1:1994
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
----------------
...




Questions, Comments and Discussion