EN 60336:1995
(Main)X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
Describes measuring methods and requirements for test arrangements to be applied for evaluating compliance with this standard together with the means of indicating compliance both of the specified characteristics of focal spots and the radiograms prepared in checking these characteristics.
Kennwerte von Brennflecken von Röntgenstrahlern für medizinische Diagnostik
Gaines équipées pour diagnostic médical - Caractéristiques des foyers
S'applique aux foyers des gaines équipées pour diagnostic médical, fonctionnant à des hautes tensions radiogènes inférieures ou égales à 200 kV. Décrit les méthodes de mesure et les dispositions d'essai à appliquer pour vérifier la conformité à la présente norme ainsi que la façon de présenter la conformité des caractéristiques spécifiées des foyers et des radiogrammes obtenus.
X-ray tube assemblies for medical diagnosis - Characteristics of focal spots (IEC 60336:1993)
General Information
- Status
- Withdrawn
- Publication Date
- 02-Apr-1995
- Withdrawal Date
- 14-Mar-1996
- Technical Committee
- CLC/TC 62 - Electrical equipment in medical practice
- Drafting Committee
- IEC/SC 62B - IEC_SC_62B
- Parallel Committee
- IEC/SC 62B - IEC_SC_62B
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Jun-2008
- Completion Date
- 01-Jun-2008
Relations
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
EN 60336:1995 is a standard published by CLC. Its full title is "X-ray tube assemblies for medical diagnosis - Characteristics of focal spots". This standard covers: Describes measuring methods and requirements for test arrangements to be applied for evaluating compliance with this standard together with the means of indicating compliance both of the specified characteristics of focal spots and the radiograms prepared in checking these characteristics.
Describes measuring methods and requirements for test arrangements to be applied for evaluating compliance with this standard together with the means of indicating compliance both of the specified characteristics of focal spots and the radiograms prepared in checking these characteristics.
EN 60336:1995 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60336:1995 has the following relationships with other standards: It is inter standard links to EN 60336:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60336:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-1998
X-ray tube assemblies for medical diagnosis - Characteristics of focal spots (IEC
60336:1993)
X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
Kennwerte von Brennflecken von Röntgenstrahlern für medizinische Diagnostik
Gaines équipées pour diagnostic médical - Caractéristiques des foyers
Ta slovenski standard je istoveten z: EN 60336:1995
ICS:
11.040.50 Radiografska oprema Radiographic equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
----
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...